The Kinematic Stabilizer is a posterior-cruciate-substituting design of total knee replacement. We have reviewed 109 primary total knee replacements in 95 patients at a mean follow-up time of 12.7 years (10 to 14). We used survival
We have reviewed 368 osteotomies carried out for osteoarthritis of the hip at the Nuffield Orthopaedic Centre. Survivorship
The Capital Hip implant was a Charnley-based system which included a flanged and a roundback stem, both of which were available in stainless steel and titanium. The system was withdrawn from the market because of its inferior performance. However, all four of the designs did not produce poor rates of survival. Using a simulated-based, finite-element
We reviewed 230 patients an average of 34 months after they had undergone partial or total meniscectomy by surgeons of different experience in a busy unit. Open and arthroscopic meniscectomies were compared. Arthroscopic partial meniscectomy resulted in a significant reduction of inpatient stay and earlier return to work and sport.
The Oxford hip and knee scores (OHS and OKS)
are validated patient-reported outcome measures used in patients undergoing
total hip replacement (THR), hip resurfacing (HR), total knee replacement
(TKR) and unicompartmental knee replacement (UKR). We analysed the
absolute OHS and OKS and change in scores following THR, HR, TKR,
and UKR performed at one specialist centre. All patients undergoing
and completing at least one Oxford score were eligible for inclusion
in the study which included 27 950 OHS and 19 750 OKS in 13 682
patients. Data were analysed using non-linear quantile regression.
The median absolute Oxford scores for THR, HR, TKR and UKR were
pre-operative 68.8% (15.0/48), 58.3% (20.0/48), 66.7% (16.0/48),
60.4% (19.0/48) respectively: and post-operative asymptote was 14.6%
(41.0/48), 5.8% (45.2/48), 31.2% (33.0/48), 29.2% (34.0/48). The
median asymptotic change from the pre-operative score for THR, HR,
TKR and UKR were 47.9% (23.0/48), 47.9% (23.0/48), 33.3% (16.0/48)
and 32.4% (15.5/48), respectively. The median time at which no further
appreciable change in score was achieved post-operatively was 0.7
years for THR, 1.1 years for HR, 0.9 years for TKR and 1.1 years
for UKR. The curves produced from this
Aims. The primary aim of this study was to analyse the position of
the acetabular and femoral components in total hip arthroplasty
undertaken using an anterior surgical approach. . Patients and Methods. In a prospective, single centre study, we used the EOS imaging
system to analyse the position of components following THA performed
via the anterior approach in 102 patients (103 hips) with a mean
age of 64.7 years (. sd. 12.6). Images were taken with patients
in the standing position, allowing measurement of both anatomical
and functional anteversion of the acetabular component. . Results. The mean inclination of the acetabular component was 39° (standard
deviation (. sd). 6), the mean anatomical anteversion was
30° (. sd. 10), and the mean functional anteversion was 31°
(. sd. 8) five days after surgery. The mean anteversion of
the femoral component was 20° (. sd. 11). Anatomical and functional
anteversion of the acetabular component differed by >
10° in 23
(22%) cases. Pelvic tilt was the only pre-operative predictive factor
of this difference. Conclusion. Our study showed that anteversion of the acetabular component
following THA using the anterior approach was greater than the recommended
target value, and that substantial differences were observed in
some patients when measured using two different measurement planes.
If these results are confirmed by further studies, and considering
that the anterior approach is intended to limit the incidence of
dislocation, a new correlation study for each reference plane (anatomical
and functional) will be necessary to define a ‘safe zone’ for use
with the anterior approach. Take home message: EOS imaging system is helpful in the pre-operative
and post-operative radiological
A consecutive series of 150 patients with clavicular fractures is presented. In 81% detailed information regarding the mechanism of the injury was available and, of these, 94% had fractured their clavicle from a direct blow on the shoulder; only 6% had fallen on the outstretched hand. This finding, at variance with commonly held views regarding the mechanism of this injury, was further investigated by biomechanical
We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the rotator cuff and to identify structural differences among anatomically distinct tears. Such information may help to identify biomarkers of tears and to provide insight into the rates of healing of different sizes of tear. The infrared spectra of 81 partial, small, medium, large and massive tears were measured using FTIR and compared with 11 uninjured control tendons. All the spectra were classified using standard techniques of multivariate
We undertook a radiological
Using a modern cementing technique, we implanted 22 stereolithographic polymeric replicas of the Charnley-Kerboul stem in 11 pairs of human cadaver femora. On one side, the replicas were cemented line-to-line with the largest broach. On the other, one-size undersized replicas were used (radial difference, 0.89 mm . sd. 0.13). CT
Components from 73 failed knee replacements (TKRs) consisting of rotating-platform, mobile-bearing and fixed-bearing implants were examined to assess the patterns of wear. The patterns were divided into low-grade (burnishing, abrasion and cold flow) and high-grade (scratching, pitting/metal embedding and delamination) to assess the severity of the wear of polyethylene. The rotating-platform group had a higher incidence of low-grade wear on the upper surface compared with the fixed-bearing group. By contrast, high-grade wear comprising scratching, pitting and third-body embedding was seen on the lower surface. Linear regression
We studied 50 patients before and after unilateral total hip replacement, and compared them, using gait
Osteolysis is due to particulate wear debris and is responsible for the long-term failure of total hip replacements. It has stimulated the development of alternative joint surfaces such as metal-on-metal or ceramic-on-ceramic implants. Since 1988 the second-generation metal-on-metal implant Metasul has been used in over 60 000 hips.
It has been shown by mechanical
The gait pattern of five amputees was recorded by visual observation and also by a quantitative measurement system. The results were compared with the gait pattern predicted from biomechanical
To investigate whether elective joint arthroplasty performed
at the weekend is associated with a different 30-day mortality We examined the 30-day cumulative mortality rate (Kaplan-Meier)
for all elective hip and knee arthroplasties performed in England
and Wales between 1st April 2003 and 31st December 2014, comprising
118 096 episodes undertaken at the weekend and 1 233 882 episodes
performed on a weekday. We used Cox proportional-hazards regression
models to assess for time-dependent variation and adjusted for identified
risk factors for mortality.Aims
Patients and Methods
Resurfacing of the humeral head is commonly used
within the UK to treat osteoarthritis (OA) of the shoulder. We present
the results of a small prospective randomised study of this procedure
using the Global CAP prosthesis with two different coatings, Porocoat
and DuoFix hydroxyapatite (HA). We followed two groups of ten patients
with OA of the shoulder for two years after insertion of the prosthesis
with tantalum marker beads, recording pain, Constant–Murley and
American Shoulder and Elbow Surgeons (ASES) outcome scores, and
using radiostereometric analysis to assess migration. The outcomes
were similar to those of other series, with significant reductions
in pain (p = 0.003) and an improvement in the Constant (p = 0.001)
and ASES scores (p = 0.006). The mean migration of the prosthesis
three months post-operatively was 0.78 mm (0.51 to 1.69) and 0.72
mm (0.33 to 1.45) for the Porocoat and DuoFix groups, respectively.
Analysis of variance indicated that the rate of migration reached
a plateau after three months post-operatively in both groups. At
follow-up of two years the mean migration was 1 mm ( The addition of a coating of HA to the sintered surface does
not improve fixation of this prosthesis. Cite this article:
The tibial components in 143 patients with total knee replacements performed before 1988 were assessed for micromotion using roentgen stereophotogrammetric
The retrospective
Survivorship