Advertisement for orthosearch.org.uk
Results 1361 - 1380 of 4639
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 217 - 223
1 Feb 2013
Hwang CJ Lee JH Baek H Chang B Lee C

We evaluated the efficacy of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (E-BMP-2) in a mini-pig model of spinal anterior interbody fusion. A total of 14 male mini-pigs underwent three-level anterior lumbar interbody fusion using polyether etherketone (PEEK) cages containing porous hydroxyapatite (HA). Four groups of cages were prepared: 1) control (n = 10 segments); 2) 50 μg E-BMP-2 (n = 9); 3) 200 μg E-BMP-2 (n = 10); and 4) 800 μg E-BMP-2 (n = 9). At eight weeks after surgery the mini-pigs were killed and the specimens were evaluated by gross inspection and manual palpation, radiological evaluation including plain radiographs and micro-CT scans, and histological analysis. Rates of fusion within PEEK cages and overall union rates were calculated, and bone formation outside vertebrae was evaluated. One animal died post-operatively and was excluded, and one section was lost and also excluded, leaving 38 sites for assessment. This rate of fusion within cages was 30.0% (three of ten) in the control group, 44.4% (four of nine) in the 50 μg E-BMP-2 group, 60.0% (six of ten) in the 200 μg E-BMP-2 group, and 77.8% (seven of nine) in the 800 μg E-BMP-2 group. Fusion rate was significantly increased by the addition of E-BMP-2 and with increasing E-BMP-2 dose (p = 0.046). In a mini-pig spinal anterior interbody fusion model using porous HA as a carrier, the implantation of E-BMP-2-loaded PEEK cages improved the fusion rate compared with PEEK cages alone, an effect that was significantly increased with increasing E-BMP-2 dosage. Cite this article: Bone Joint J 2013;95-B:217–23


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 966 - 970
1 Nov 1990
Maloney W Jasty M Rosenberg A Harris W

We have reviewed 25 cases of focal femoral osteolysis in radiographically stable, cemented femoral implants. In three hips retrieved at post-mortem from two patients, we have been able to make a detailed biomechanical and histological analysis. The interval between arthroplasty and the appearance of focal osteolysis on clinical radiographs ranged from 40 to 168 months, and in over 70% of the cases this did not appear until after five or more years. Few had significant pain and there was no relation to age, sex or original diagnosis. The most common site for osteolysis were Gruen zones 2 and 3 on the anteroposterior radiograph and zones 5 and 6 on the lateral radiograph. In 15 cases (60%), the area of osteolysis corresponded to either a defect in the cement mantle or an area of very thin cement. The rate of progression of these lesions was variable, but to date only one has progressed to gross loosening of the femoral component. The back-scatter scanning electron microscopic examination of serial sections and biomechanical testing of the post-mortem specimens demonstrated focal cement fracture around implants that were otherwise rigidly fixed. In eight cases from which tissue was available, histology showed a histiocytic reaction with evidence of particulate polymethylmethacrylate. We consider that this local fragmentation was the stimulus for local osteolysis in an otherwise stable cemented femoral component


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 186 - 190
1 Feb 2020
Puri A Hegde P Gulia A Parikh M

Aims

The aim of this study was to analyze the complications and outcomes of treatment in a series of previously untreated patients with a primary aneurysmal bone cyst (ABC) who had been treated by percutaneous sclerosant therapy using polidocanol.

Methods

Between January 2010 and December 2016, 56 patients were treated primarily with serial intralesional sclerosant injections. Their mean age was 20 years (1 to 54). The sites involved were clavicle (n = 3), humeri (n = 11), radius (n = 1), ulna (n = 3), hand (n = 2), pelvis (n = 12), femur (n = 7), tibia (n = 13), fibula (n = 3), and foot (n = 1). After histopathological confirmation of the diagnosis, 3% polidocanol (hydroxypolyaethoxydodecan) was injected into the lesion under image intensifier guidance. Patients were evaluated clinically and radiologically every six to eight weeks. In the absence of clinical and/or radiological response, a repeat sclerosant injection was given after eight to 12 weeks and repeated at similar intervals if necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved. We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap


Bone & Joint Research
Vol. 1, Issue 8 | Pages 180 - 191
1 Aug 2012
Stilling M Kold S de Raedt S Andersen NT Rahbek O Søballe K

Objectives. The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear. Methods. A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed. Results. The precision for 2D wear measures was 0.078 mm, 0.102 mm, and 0.076 mm for EGS-RSA, MB-RSA, and PolyWare, respectively. For the 3D wear measures the precision was 0.185 mm, 0.189 mm, and 0.244 mm for EGS-RSA, MB-RSA, and PolyWare respectively. Repeatability was similar for all methods within the same dimension, when compared between 2D and 3D (all p > 0.28). For the 2D RSA methods, accuracy was below 0.055 mm and at least 0.335 mm for PolyWare. For 3D measurements, accuracy was 0.1 mm, 0.2 mm, and 0.3 mm for EGS-RSA, MB-RSA and PolyWare respectively. PolyWare was less accurate compared with RSA methods (p = 0.036). No difference was observed between the RSA methods (p = 0.10). Conclusions. For all methods, precision and accuracy were better in 2D, with RSA methods being superior in accuracy. Although less accurate and precise, 3D RSA defines the clinically relevant wear pattern (multidirectional). PolyWare is a good and low-cost alternative to RSA, despite being less accurate and requiring a larger sample size


Bone & Joint 360
Vol. 9, Issue 1 | Pages 18 - 21
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 805 - 810
1 Jun 2012
Flinkkilä T Kaisto T Sirniö K Hyvönen P Leppilahti J

We assessed the short- to mid-term survival of metallic press-fit radial head prostheses in patients with radial head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with a mean age of 56 years (23 to 85) with acute unstable elbow injuries, including a fracture of the radial head requiring metallic replacement of the radial head, were reviewed retrospectively. Survival of the prosthesis was assessed from the radiographs of 37 patients after a mean follow-up of 50 months (12 to 107). The functional results of 31 patients were assessed using range-of-movement, Mayo elbow performance score (MEPS), Disabilities of the Arm, Shoulder and Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed, nine had been removed because of loosening, and three remained implanted but were loose. The mean time from implantation to loosening was 11 months (2 to 24). Radiolucent lines that developed around the prosthesis before removal were mild in three patients, moderate in one and severe in five. Range of movement parameters and mass grip strength were significantly lower in the affected elbow than in the unaffected side. The mean MEPS score was 86 (40 to 100) and the mean DASH score was 23 (0 to 81). According to RAND-36 scores, patients had more pain and lower physical function scores than normal population values. Loosening of press-fit radial head prostheses is common, occurs early, often leads to severe osteolysis of the proximal radius, and commonly requires removal of the prosthesis


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 220 - 226
1 Feb 2020
Clough TM Ring J

Aims

Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR.

Methods

We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 394 - 399
1 Mar 2020
Parker MJ Cawley S

Aims

A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome.

Methods

We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile).


Bone & Joint 360
Vol. 9, Issue 2 | Pages 30 - 33
1 Apr 2020


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 501 - 505
1 Apr 2020
Gnanasekaran R Beresford-Cleary N Aboelmagd T Aboelmagd K Rolton D Hughes R Seel E Blagg S

Aims

Early cases of cauda equina syndrome (CES) often present with nonspecific symptoms and signs, and it is recommended that patients undergo emergency MRI regardless of the time since presentation. This creates substantial pressure on resources, with many scans performed to rule out cauda equina rather than confirm it. We propose that compression of the cauda equina should be apparent with a limited sequence (LS) scan that takes significantly less time to perform.

Methods

In all, 188 patients with suspected CES underwent a LS lumbosacral MRI between the beginning of September 2017 and the end of July 2018. These images were read by a consultant musculoskeletal radiologist. All images took place on a 3T or 1.5T MRI scanner at Stoke Mandeville Hospital, Aylesbury, UK, and Royal Berkshire Hospital, Reading, UK.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 177 - 180
1 Feb 2013
Arthur CHC Wood AM Keenan ACM Clayton RAE Walmsley P Brenkel I

We report ten-year clinical and radiological follow-up data for the Sigma Press Fit Condylar total knee replacement system (Sigma PFC TKR). Between October 1998 and October 1999 a total of 235 consecutive PFC Sigma TKRs were carried out in 203 patients. Patients were seen at a specialist nurse-led clinic seven to ten days before admission and at six and 18 months, three, five and eight to ten years after surgery. Data were recorded prospectively at each clinic visit. Radiographs were obtained at the five- and eight- to ten-year follow-up appointments. Of the 203 patients, 147 (171 knees) were alive at ten years and 12 were lost to follow-up. A total of eight knees (3.4%) were revised, five for infection and three to change the polyethylene insert. The survival at ten years with an endpoint of revision for any reason was 95.9%, and with an endpoint of revision for aseptic failure was 98.7%. The mean American Knee Society Score (AKSS) was 79 (10 to 99) at eight to ten years, compared with 31 (2 to 62) pre-operatively. Of 109 knee with radiographs reviewed, 47 knees had radiolucent lines but none showed evidence of loosening. Cite this article: Bone Joint J 2013;95-B:177–80


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans. Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 896 - 897
1 Aug 2002
Kelly M McBirnie JM Burnett R

The new Ionising Radiation (Medical Exposure) Regulations 2000 (IR (ME)ER) were implemented in January 2001. These regulations state that “the referrer must record in the patient’s notes that a radiograph was taken and what it showed”. As a result it is now incumbent upon the orthopaedic surgeon to document formally the findings of all requested radiographs. We present a case in which a left upper bronchial carcinoma was detected initially on a radiograph of the left shoulder. It highlights the importance of careful examination of the entire radiographic image and the documenting of the findings


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1653 - 1659
1 Dec 2011
Bordei P

Platelet-derived growth factor (PDGF) is known to stimulate osteoblast or osteoprogenitor cell activity. We investigated the effect of locally applied PDGF from poly-. d. ,l-lactide (PDLLA)-coated implants on fracture healing in a rat model. A closed fracture of the right tibia of four-month-old Sprague-Dawley rats (n = 40) was stabilised with implants coated with a biodegradable PDLLA versus implants coated with PDLLA and PDGF. Radiographs were taken throughout the study, and a marker of DNA activity, bromodeoxyuridine (BrdU), was injected before the rats were killed at three, seven and ten days. The radiographs showed consolidation of the callus in the PDGF-treated group compared with the control group at all three time points. In the PDGF-treated group, immunohistochemical staining of BrdU showed that the distribution of proliferating cells in all cellular events was higher after ten days compared with that at three and seven days. These results indicate that local application of PDGF from biodegradable PDLLA-coated implants significantly accelerates fracture healing in experimental animals. Further development may help fracture healing in the clinical situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 269 - 272
1 Feb 2011
Wansbrough G Boyne N Pollard CW

We present a patient who underwent delayed sub-periosteal hemipelvectomy for control of infection and to enable soft-tissue cover after trauma. At four months after amputation, clinical examination and radiographs demonstrated almost complete re-ossification of the hemipelvis. This has allowed the patient to regain sitting balance and to use a walking prosthesis designed for patients following disarticulation of the hip. After 14 months from injury, no perineal hernia has developed, and no dysfunction of pelvic organs is attributable to heterotopic bone formation or adhesions. The patient’s mobility with a prosthesis is similar to that expected of a through-hip amputee


Aims

Methicillin-resistant Staphylococcus aureus (MRSA) can cause wound infections via a ‘Trojan Horse’ mechanism, in which neutrophils engulf intestinal MRSA and travel to the wound, releasing MRSA after apoptosis. The possible role of intestinal MRSA in prosthetic joint infection (PJI) is unknown.

Methods

Rats underwent intestinal colonization with green fluorescent protein (GFP)-tagged MRSA by gavage and an intra-articular wire was then surgically implanted. After ten days, the presence of PJI was determined by bacterial cultures of the distal femur, joint capsule, and implant. We excluded several other possibilities for PJI development. Intraoperative contamination was excluded by culturing the specimen obtained from surgical site. Extracellular bacteraemia-associated PJI was excluded by comparing with the infection rate after intravenous injection of MRSA or MRSA-carrying neutrophils. To further support this theory, we tested the efficacy of prophylactic membrane-permeable and non-membrane-permeable antibiotics in this model.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 268 - 272
1 Feb 2020
Diarbakerli E Savvides P Wihlborg A Abbott A Bergström I Gerdhem P

Aims

Idiopathic scoliosis is the most common spinal deformity in adolescents and children. The aetiology of the disease remains unknown. Previous studies have shown a lower bone mineral density in individuals with idiopathic scoliosis, which may contribute to the causation. The aim of the present study was to compare bone health in adolescents with idiopathic scoliosis with controls.

Methods

We included 78 adolescents with idiopathic scoliosis (57 female patients) at a mean age of 13.7 years (8.5 to 19.6) and 52 age- and sex-matched healthy controls (39 female patients) at a mean age of 13.8 years (9.1 to 17.6). Mean skeletal age, estimated according to the Tanner-Whitehouse 3 system (TW3), was 13.4 years (7.4 to 17.8) for those with idiopathic scoliosis, and 13.1 years (7.4 to 16.5) for the controls. Mean Cobb angle for those with idiopathic scoliosis was 29° (SD 11°). All individuals were scanned with dual energy x-ray absorptiometry (DXA) and peripheral quantitative CT (pQCT) of the left radius and tibia to assess bone density. Statistical analyses were performed with independent-samples t-test, the Mann-Whitney U test, and the chi-squared test.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1314 - 1319
1 Oct 2011
Zhang CQ Sun Y Chen SB Jin DX Sheng JG Cheng XG Xu J Zeng BF

Free vascularised fibular grafting has been reported to be successful for adult patients with osteonecrosis of the femoral head (ONFH). However, its benefit in teenage patients with post-traumatic ONFH has not been determined. We evaluated the effectiveness of free vascularised fibular grafting in the treatment of this condition in children and adolescents. We retrospectively analysed 28 hips in 28 patients in whom an osteonecrotic femoral head had been treated with free vascularised fibular grafting between 2002 and 2008. Their mean age was 16.3 years (13 to 19). The stage of the disease at time of surgery, and results of treatment including pre- and post-operative Harris hip scores, were studied. We defined clinical failure as conversion to total hip replacement. All patients were followed up for a mean of four years (2 to 7). The mean Harris hip score improved from 60.4 (37 to 84) pre-operatively to 94.2 (87 to 100) at final follow-up. At the latest follow-up we found improved or unchanged radiographs in all four initially stage II hips and in 23 of 24 stage III or IV hips. Only one hip (stage V) deteriorated. No patient underwent total hip replacement. Free vascularised fibular grafting is indicated for the treatment of post-traumatic ONFH in teenage patients


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims

Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees.

Methods

A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed.