Advertisement for orthosearch.org.uk
Results 1361 - 1380 of 1927
Results per page:
Bone & Joint 360
Vol. 5, Issue 2 | Pages 33 - 35
1 Apr 2016


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 617 - 622
1 May 2015
Haddad FS Konan S Tahmassebi J

The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years.

Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14).

Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores.

No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years.

We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems.

Cite this article: Bone Joint J 2015; 97-B:617–22.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 654 - 659
1 May 2016
Garala K Taub NA Dias JJ

Aims

This study explores the epidemiology of patients with a fracture of the scaphoid presenting to a regional teaching hospital.

Patients and Methods

All patients with a confirmed fracture of the scaphoid over a retrospective period between January 2010 and May 2013 were included. Their demographics, deprivation status and when the fracture occurred was noted and assessed. There were 415 fractures in 365 males and 50 females.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 185 - 190
1 May 2016
Yuenyongviwat V Iamthanaporn K Hongnaparak T Tangtrakulwanich B

Objectives

Nylon sutures and skin staples are used commonly in total knee arthroplasty (TKA) surgical wound closure. However, there is no study that compares the wound healing efficacy and patient satisfaction scores of both techniques in the same knee.

Methods

We randomised 70 patients who underwent primary TKA into two groups. In one group of 34 patients, the skin at the upper half of the wound was closed with skin staples and the lower half of the wound was closed with simple interrupted nylon sutures. In the other group of 36 patients, the skin at the upper half of the wound was closed with nylon stitches and the lower half of the wound was closed with skin staples. We recorded the wound closure time, pain score at the time of stitch removal, wound complication rate, patient satisfaction score, and the Hollander wound evaluation score at the post-operative periods of five days, 14 days, six weeks, three months, and six months. Each half wound was analysed separately.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 641 - 646
1 May 2016
Ballas R Edouard P Philippot R Farizon F Delangle F Peyrot N

Aims

The purpose of this study was to analyse the biomechanics of walking, through the ground reaction forces (GRF) measured, after first metatarsal osteotomy or metatarsophalangeal joint (MTP) arthrodesis.

Patients and Methods

A total of 19 patients underwent a Scarf osteotomy (50.3 years, standard deviation (sd) 12.3) and 18 underwent an arthrodesis (56.2 years, sd 6.5). Clinical and radiographical data as well as the American Orthopaedic Foot and Ankle Society (AOFAS) scores were determined. GRF were measured using an instrumented treadmill. A two-way model of analysis of variance (ANOVA) was used to determine the effects of surgery on biomechanical parameters of walking, particularly propulsion.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 24 - 26
1 Aug 2015

The August 2015 Spine Roundup360 looks at: Steroids may be useful in avoiding dysphagia in anterior cervical discectomy and fusion (ACDF); Perhaps X-Stop ought to stop?; Is cervical plexus block in ACDF the gateway to day case spinal surgery?; Epidural past its heyday?; Steroids in lumbar back pain; Lumbar disc replacement improving; Post-discectomy arthritis


Bone & Joint 360
Vol. 4, Issue 4 | Pages 27 - 29
1 Aug 2015

The August 2015 Trauma Roundup360 looks at: Thromboprophylaxis not required in lower limb fractures; Subclinical thyroid dysfunction and fracture risk: moving the boundaries in fracture; Posterior wall fractures refined; Neurological injury and acetabular fracture surgery; Posterior tibial plateau fixation; Tibial plateau fractures in the longer term; Comprehensive orthogeriatric care and hip fracture; Compartment syndrome: in the eye of the beholder?


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 298 - 300
1 Mar 2016
Fullilove S Gozzard C

The results of the DRAFFT (distal radius acute fracture fixation trial) study, which compared volar plating with Kirschner (K-) wire fixation for dorsally displaced fractures of the distal radius, were published in August 2014. The use of K-wires to treat these fractures is now increasing, with a concomitant decline in the use of volar locking plates.

We provide a critical appraisal of the DRAFFT study and question whether surgeons have been unduly influenced by its headline conclusions.

Cite this article: Bone Joint J 2016;98-B:298–300.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 10 - 12
1 Dec 2014

The December 2014 Hip & Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection


Bone & Joint 360
Vol. 4, Issue 4 | Pages 2 - 7
1 Aug 2015
Nicol S Jackson M Monsell F

This review explores recent advances in fixator design and used in contemporary orthopaedic practice including the management of bone loss, complex deformity and severe isolated limb injury.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 381 - 386
1 Mar 2016
Prasad N Ali A Stanley D

Aims

We review our experience of Coonrad-Morrey total elbow arthroplasty (TEA) for fractures of the distal humerus in non-rheumatoid patients with a minimum of ten years follow-up.

Patients and Methods

TEA through a triceps splitting approach was peformed in 37 non-rheumatoid patients for a fracture of the distal humerus between 1996 and 2004. One patient could not be traced and 17 had died before the tenth anniversary of their surgery. This left 19 patients with a minimum follow-up of ten years to form the study group. Of these, 13 patients were alive at the time of final review. The other six had died, but after the tenth anniversary of their elbow arthroplasty. Their clinical and radiological data were included in the study.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims

To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries.

Patients and Methods

We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 21 - 22
1 Jun 2015

The June 2015 Spine Roundup360 looks at: Less is more in pyogenic vertebral osteomyelitis; Paracetamol out of favour in spinal pain but effective for osteoarthritis; Local wound irrigation to reduce infection?; Lumbar facet joint effusion: a reliable prognostic sign?; SPORT for the octogenarian; Neurological deterioration following traumatic spinal cord injury; PROMS in spinal surgery


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 307 - 312
1 Mar 2016
Maggs JL Smeatham A Whitehouse SL Charity J Timperley AJ Gie GA

Aims

We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients).

Patients and Methods

A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 420 - 424
1 Mar 2016
Wordsworth M Lawton G Nathwani D Pearse M Naique S Dodds A Donaldson H Bhattacharya R Jain A Simmons J Hettiaratchy S

Aims

The management of open lower limb fractures in the United Kingdom has evolved over the last ten years with the introduction of major trauma networks (MTNs), the publication of standards of care and the wide acceptance of a combined orthopaedic and plastic surgical approach to management. The aims of this study were to report recent changes in outcome of open tibial fractures following the implementation of these changes.

Patients and Methods

Data on all patients with an open tibial fracture presenting to a major trauma centre between 2011 and 2012 were collected prospectively. The treatment and outcomes of the 65 Gustilo Anderson Grade III B tibial fractures were compared with historical data from the same unit.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 17 - 18
1 Jun 2015

The June 2015 Wrist & Hand Roundup360 looks at: Collagenase and Dupuytren’s disease – a genuine alternative to surgery?; iPad PROMise?; Should we learn how to do endoscopic carpal tunnel release?; Two-week radiographs a relic of the past?; Bible? Aspirate or excise?; Patient expectations and trapeziometacarpal osteoarthritis; Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 60 - 63
1 Jan 2016
Ko LM Hozack WJ

Dual mobility cups have two points of articulation, one between the shell and the polyethylene (external bearing) and one between the polyethylene and the femoral head (internal bearing). Movement occurs at the inner bearing; the outer bearing only moves at extremes of movement.

Dislocation after total hip arthroplasty (THA) is a cause of much morbidity and its treatment has significant cost implications. Dual mobility cups provide an increased range of movement and a may reduce the risk of dislocation.

This paper reviews the use of these cups in THA, particularly where stability is an issue. Dual mobility cups may be of benefit in primary THA in patients at a high risk of dislocation, such as those who are older with increased comorbidities and a higher American Association of Anesthesiology grade and those with a neuromuscular disease. They may be used at revision surgery where the risk of dislocation is high, such as in patients with many prior dislocations, or those with abductor deficiency. They may also be used in THA for displaced fractures of the femoral neck, which has a notoriously high rate of dislocation.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):60–3.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 387 - 394
1 Mar 2016
Eguchi Y Oikawa Y Suzuki M Orita S Yamauchi K Suzuki M Aoki Y Watanabe A Takahashi K Ohtori S

Aims

The aim of this study was to evaluate the time course of changes in parameters of diffusion tensor imaging (DTI) such as fractional anisotropy (FA) and apparent diffusion coefficient (ADC) in patients with symptomatic lumbar disc herniation. We also investigated the correlation between the severity of neurological symptoms and these parameters.

Patients and Methods

A total of 13 patients with unilateral radiculopathy due to herniation of a lumbar disc were investigated with DTI on a 1.5T MR scanner and underwent micro discectomy. There were nine men and four women, with a median age of 55.5 years (19 to 79). The changes in the mean FA and ADC values and the correlation between these changes and the severity of the neurological symptoms were investigated before and at six months after surgery.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 395 - 401
1 Mar 2016
Helenius I Keskinen H Syvänen J Lukkarinen H Mattila M Välipakka J Pajulo O

Aims

In a multicentre, randomised study of adolescents undergoing posterior spinal fusion for idiopathic scoliosis, we investigated the effect of adding gelatine matrix with human thrombin to the standard surgical methods of controlling blood loss.

Patients and Methods

Patients in the intervention group (n = 30) were randomised to receive a minimum of two and a maximum of four units of gelatine matrix with thrombin in addition to conventional surgical methods of achieving haemostasis. Only conventional surgical methods were used in the control group (n = 30). We measured the intra-operative and total blood loss (intra-operative blood loss plus post-operative drain output).


Bone & Joint Research
Vol. 4, Issue 2 | Pages 11 - 16
1 Feb 2015
C. Wyatt M Wright T Locker J Stout K Chapple C Theis JC

Objectives

Effective analgesia after total knee arthroplasty (TKA) improves patient satisfaction, mobility and expedites discharge. This study assessed whether continuous femoral nerve infusion (CFNI) was superior to a single-shot femoral nerve block in primary TKA surgery completed under subarachnoid blockade including morphine.

Methods

We performed an adequately powered, prospective, randomised, placebo-controlled trial comparing CFNI of 0.125% bupivacaine versus normal saline following a single-shot femoral nerve block and subarachnoid anaesthesia with intrathecal morphine for primary TKA. Patients were randomised to either treatment (CFNI 0 ml to 10 ml/h 0.125% bupivacaine) or placebo (CFNI 0 ml to 10 ml/h normal saline). Both groups received a single-shot femoral nerve block (0.25% 20 ml bupivacaine) prior to placement of femoral nerve catheter and subarachnoid anaesthesia with intrathecal morphine. All patients had a standardised analgesic protocol. The primary end point was post-operative visual analogue scale (VAS) pain score over 72 hours post-surgery. Secondary outcomes were morphine equivalent dose, range of movement, side effects, and length of stay.