To assess the effect of high tibial and distal femoral osteotomies
(HTO and DFO) on the pressure characteristics of the ankle joint. Varus and valgus malalignment of the knee was simulated in human
cadaver full-length legs. Testing included four measurements: baseline
malalignment, 5° and 10° re-aligning osteotomy, and control baseline
malalignment. For HTO, testing was rerun with the subtalar joint
fixed. In order to represent half body weight, a 300 N force was applied
onto the femoral head. Intra-articular sensors captured ankle pressure.Aims
Materials and Methods
We conducted a study to determine whether radiological parameters
correlate with patient reported functional outcome, health-related
quality of life and physical measures of function in patients with
a fracture of the distal radius. The post-operative palmar tilt and ulnar variance at six weeks
and 12 months were correlated with the Patient Rated Wrist Evaluation,
Disabilities of the Arm, Shoulder and Hand, and EuroQol scores,
grip strength, pinch strength and range of movement at three, six
and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical
fixation, with either percutaneous pinning or reconstruction with
a volar plate, for a fracture of the distal radius.Aims
Patients and Methods
There is a paucity of information on the pre-operative coronal
imbalance in patients with degenerative lumbar scoliosis (DLS) and
its influence on surgical outcomes. A total of 284 DLS patients were recruited into this study, among
whom 69 patients were treated surgically and the remaining 215 patients
conservatively Patients were classified based on the coronal balance
distance (CBD): Type A, CBD <
3 cm; Type B, CBD >
3 cm and C7
Plumb Line (C7PL) shifted to the concave side of the curve; Type
C, CBD >
3 cm and C7PL shifted to the convex side.Aims
Patients and Methods
Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm3, 0.16 g/cm3 and 0.24 g/cm3). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°.Objectives
Methods
We studied 29 girls and one boy with adolescent idiopathic scoliosis who were at Risser grade 0 at the time of posterior spinal fusion and were followed until maturity (mean 7.8 years). We used serial radiographs to measure the ratio of disc to vertebral height in the fused segments and to detect differential anterior spinal growth and assess its effect on scoliosis, vertebral rotation, kyphosis, and rib-vertebral-angle difference (RVAD). From one year after surgery to the latest review, the percentage anterior disc height decreased by nearly one-half and the percentage posterior disc height by nearly one-third in the fused segments (p <
0.001). There was a 4 degree increase in mean Cobb
Displaced extension supracondylar fractures of the elbow 1. One hundred and ten children were treated by reduction and stabilisation by two pins inserted laterally at an
1. The results have been reported of total hip replacement by a low-friction technique using high-density polyethylene for the acetabular component in 379 primary interventions, performed between November 1962 and December 1965 and followed for between four and seven years. 2. Apart from failures due to infection, the rate of which in the era under review was 3·8 per cent, late failures from mechanical causes were unusual after total hip replacement by this technique. When the socket was cemented in position, which is now routine, the late mechanical failure from all causes was only 1·3 per cent in 210 cases. 3. As regards the quality of the results and their maintenance over the years, the results were so good (Table X) that it was unnecessary to distinguish an intermediate class of "improvement" between success and failure. 4. As regards relief of pain and ability to walk, the average final rating, on a scale numbered 1 to 6, was 5·9 for both, indicating 90 per cent of patients in Grade 6 (excellent) and only 10 per cent in Grade 5 (good). 5. The average recovery of movement was not as spectacular and was influenced considerably by the pre-operative range, but in all cases that range was improved on. Even starting with the stiffest of hips about one patient in four regained a right
To compare the outcomes for trochanteric fractures treated with
a sliding hip screw (SHS) or a cephalomedullary nail. A total of 400 patients with a trochanteric hip fracture were
randomised to receive a SHS or a cephalomedullary nail (Targon PFT).
All surviving patients were followed up to one year from injury.
Functional outcome was assessed by a research nurse blinded to the
implant used.Aims
Patients and Methods
The objective of this five-year prospective, blinded, randomised
controlled trial (RCT) was to compare femoral head penetration into
a vitamin E diffused highly cross-linked polyethylene (HXLPE) liner
with penetration into a medium cross-linked polyethylene control
liner using radiostereometric analysis. Patients scheduled for total hip arthroplasty (THA) were randomised
to receive either the study E1 (32 patients) or the control ArComXL
polyethylene (35 patients). The median age (range) of the overall
cohort was 66 years (40 to 76).Aims
Patients and Methods
We have evaluated the use of a synthetic porous ceramic (Triosite) as a substitute for bone graft in posterior spinal fusion for idiopathic scoliosis. In a prospective, randomised study 341 patients at five hospitals in the UK and France were randomly allocated either to autograft from the iliac crest or rib segments (171) or to receive Triosite blocks (170). All patients were assessed after operation and at 3, 6, 12 and 18 months. The two groups were similar with regard to all demographic and baseline variables, but the 184 treated in France (54%) had Cotrel-Dubouset instrumentation and the 157 treated in the UK usually had Harrington-Luque implants. In the Triosite group the average Cobb
Transtrochanteric rotational osteotomy (TRO) is performed for
young patients with non-traumatic osteonecrosis of the femoral head
(ONFH) to preserve the hip. We aimed to investigate the long-term
outcomes and the risk factors for failure 15 years after this procedure. This study included 95 patients (111 hips) with a mean age of
40 years (21 to 64) who underwent TRO for ONFH. The mean follow-up
was 18.2 years (3 to 26). Kaplan–Meier survivorship analyses were
performed with conversion to total hip arthroplasty (THA) and radiological
failure due to secondary collapse of the femoral head or osteoarthritic changes
as the endpoint. Multivariate analyses were performed to assess
risk factors for each outcome.Aims
Patients and Methods
Although vertebroplasty is very effective for relieving acute pain from an osteoporotic vertebral compression fracture, not all patients who undergo vertebroplasty receive the same degree of benefit from the procedure. In order to identify the ideal candidate for vertebroplasty, pre-operative prognostic demographic or clinico-radiological factors need to be identified. The objective of this study was to identify the pre-operative prognostic factors related to the effect of vertebroplasty on acute pain control using a cohort of surgically and non-surgically managed patients. Patients with single-level acute osteoporotic vertebral compression fracture at thoracolumbar junction (T10 to L2) were followed. If the patients were not satisfied with acute pain reduction after a three-week conservative treatment, vertebroplasty was recommended. Pain assessment was carried out at the time of diagnosis, as well as three, four, six, and 12 weeks after the diagnosis. The effect of vertebroplasty, compared with conservative treatment, on back pain (visual analogue score, VAS) was analysed with the use of analysis-of-covariance models that adjusted for pre-operative VAS scores.Objectives
Patients and Methods
This paper reports a new method for expressing numerically asymmetry of the contour of the back in a forward-bending position. Information is given at three spinal levels (T8, T12 and L3) for 636 schoolchildren aged 8 to 15 years. Rib-hump and lumbar-hump scores were standardised to create trunk asymmetry scores (TASs) making comparison possible between children of different age, size and sex. Two groups of children were defined: those with clinically straight spines (585 children); and those with clinical evidence of lateral spinal curves (51 children). In the children with clinically straight spines the main findings were: about 1:4 had objectively detectable rib and lumbar humps; female-to-male ratios were 1.2:1 for the thoracic region and 1.4:1 for the lumbar region; right humps were about 10 times more common than left; TASs in the boys and girls at each spinal level had normal distributions about means to the right of zero (where zero represents perfect symmetry); at T8 and T12, a wider scatter of TASs in girls than in boys; at L3, larger TASs in girls than in boys; a relation between shortening of one lower limb and a contralateral hump on the back; and no relation to age (except at L3), stature (corrected for age) or handedness. The findings are discussed in relation to possible causes of back contour asymmetry, early diagnosis of scoliosis by screening, sexual dimorphism and significance for the pathogenesis of idiopathic scoliosis. Ten children with clinically straight spines and larger TASs, and 42 out of 51 children with clinical evidence of lateral spinal curves in the forward-bending position attended for radiographic examination. Twelve children had "scoliosis curves" of 11 degrees or more as defined by the Scoliosis Research Society. The results are reported in relation to TASs, spinal curve
1. During a fifteen-year period a clinical, radiological and in some cases a surgical study has been made of 319 patients suffering from spondylolisthesis–that is, forward slipping of one lumbar vertebra on another or forward sagging of the whole lumbar spine in relation to the sacrum. 2. The five etiological factors are described, and the cases are assigned to five groups according to the factor responsible for the slip. In every case slipping is permitted by a lesion of the apparatus which normally resists the forward thrust of the lower lumbar spine–that is, the hook of the neural arch composed of the pedicle, the pars interarticularis and the inferior articular facet engaging caudally over the superior articular facet of the vertebra below. 3. In Group I (congenital spondylolisthesis–sixty-six cases) the lesion is a congenital defect of the facets. In Group II (spondylolytic spondylolisthesis–164 cases) the lesion occurs in the region of the pars interarticularis and is either an elongation of the bone or a break in continuity. There are reasons for thinking that the lesion is caused by stress over a long period rather than by acute injury or by a congenital anomaly of ossification. In Group IV (degenerative spondylolisthesis–eighty cases) the lesion of the facets is degenerative. There are no good grounds for thinking that an abnormality of the
The aim of this study was to identify patient- and surgery-related
risk factors for sustaining an early periprosthetic fracture following
primary total hip arthroplasty (THA) performed using a double-tapered
cementless femoral component (Bi-Metric femoral stem; Biomet Inc.,
Warsaw, Indiana). A total of 1598 consecutive hips, in 1441 patients receiving
primary THA between January 2010 and June 2015, were retrospectively
identified. Level of pre-operative osteoarthritis, femoral Dorr
type and cortical index were recorded. Varus/valgus placement of
the stem and canal fill ratio were recorded post-operatively. Periprosthetic
fractures were identified and classified according to the Vancouver
classification. Regression analysis was performed to identify risk
factors for early periprosthetic fracture.Aims
Patients and Methods
The Advance Medial-Pivot total knee arthroplasty (TKA) was designed
to reflect contemporary data regarding the kinematics of the knee.
We wished to examine the long-term results obtained with this prosthesis
by extending a previous evaluation. We retrospectively evaluated prospectively collected data from
225 consecutive patients (41 men and 184 women; mean age at surgery
71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up
of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both
subjective and objective) and radiological outcome were assessed.
Pre- and post-operative clinical and radiographic data were available
at regular intervals for all patients. A total of ten patients (4.4%;
ten TKAs) were lost to follow-up.Aims
Patients and Methods