The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty. The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, Objectives
Methods
Peri-acetabular tumour resections and their subsequent
reconstruction are among the most challenging procedures in orthopaedic
oncology. Despite the fact that a number of different pelvic endoprostheses
have been introduced, rates of complication remain high and long-term
results are mostly lacking. In this retrospective study, we aimed to evaluate the outcome
of reconstructing a peri-acetabular defect with a pedestal cup endoprosthesis
after a type 2 or type 2/3 internal hemipelvectomy. A total of 19 patients (11M:8F) with a mean age of 48 years (14
to 72) were included, most of whom had been treated for a primary
bone tumour (n = 16) between 2003 and 2009. After a mean follow-up
of 39 months (28 days to 8.7 years) seven patients had died. After
a mean follow-up of 7.9 years (4.3 to 10.5), 12 patients were alive,
of whom 11 were disease-free. Complications occurred in 15 patients.
Three had recurrent dislocations and three experienced aseptic loosening.
There were no mechanical failures. Infection occurred in nine patients,
six of whom required removal of the prosthesis. Two patients underwent
hindquarter amputation for local recurrence. The implant survival rate at five years was 50% for all reasons,
and 61% for non-oncological reasons. The mean Musculoskeletal Tumor
Society score at final follow-up was 49% (13 to 87). Based on these poor results, we advise caution if using the pedestal
cup for reconstruction of a peri-acetabular tumour resection. Cite this article:
A total of 20 patients with a depressed fracture
of the lateral tibial plateau (Schatzker II or III) who would undergo open
reduction and internal fixation were randomised to have the metaphyseal
void in the bone filled with either porous titanium granules or
autograft bone. Radiographs were undertaken within one week, after
six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint
surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower
(p <
0.001) and the operating time less (p <
0.002) when titanium
granules were used. The indication is that it is therefore beneficial to use porous
titanium granules than autograft bone to fill the void created by
reducing a depressed fracture of the lateral tibial plateau. There
is no donor site morbidity, the operating time is shorter and the
risk of recurrent depression of the articular surface is less. Cite this article:
Atypical cartilaginous tumours are usually treated
by curettage. The purpose of this study was to show that radiofrequency
ablation was an effective alternative treatment. We enrolled 20 patients (two male, 18 female, mean age 56 years
(36 to 72) in a proof-of-principle study. After inclusion, biopsy
and radiofrequency ablation were performed, followed three months
later by curettage and adjuvant phenolisation. The primary endpoint
was the proportional necrosis in the retrieved material. Secondary endpoints
were correlation with the findings on gadolinium enhanced MRI, functional
outcome and complications. Our results show that 95% to 100% necrosis was obtained in 14
of the 20 patients. MRI had a 91% sensitivity and 67% specificity
for detecting residual tumour after curettage. The mean functional
outcome (MSTS) score six weeks after radiofrequency ablation was
27.1 (23 to 30) compared with 18.1 (12 to 25) after curettage (p
<
0.001). No complications occurred after ablation, while two
patients developed a pathological fracture after curettage. We have shown that radiofrequency ablation is capable of completely
eradicating cartilaginous tumour cells in selective cases. MRI has
a 91% sensitivity for detecting any residual tumour. Radiofrequency
ablation can be performed on an outpatient basis allowing a rapid
return to normal activities. If it can be made more effective, it
has the potential to provide better local control, while improving
functional outcome. Cite this article:
The August 2015 Spine Roundup360 looks at: Steroids may be useful in avoiding dysphagia in anterior cervical discectomy and fusion (ACDF); Perhaps X-Stop ought to stop?; Is cervical plexus block in ACDF the gateway to day case spinal surgery?; Epidural past its heyday?; Steroids in lumbar back pain; Lumbar disc replacement improving; Post-discectomy arthritis
The August 2015 Hip &
Pelvis Roundup360 looks at: The well-fixed acetabular revision; Predicting complications in revision arthroplasty; Is infection associated with fixation?; Front or back? An enduring question in hip surgery; Muscle-sparing approaches?; Gabapentin as a post-operative analgesic adjunct; An Indian take on AVN of the hip; Weight loss and arthroplasty
The August 2014 Trauma Roundup360 looks at: On-table CT for calcaneal fractures; timing of femoral fracture surgery and outcomes; salvage arthroplasty for failed internal fixation of the femoral neck; screw insertion in osteoporotic bone; fibular intramedullary nailing on the ascendant; posterior wall acetabular fractures not all that innocent; bugs, plating and resistance and improving outcomes in olecranon tension band wiring.
Total wrist arthrodesis (TWA) produces a spectrum of outcomes.
We investigated this by reviewing 77 consecutive TWA performed for
inflammatory and post-traumatic arthropathies, wrist instability
and as a salvage procedure. All operations were performed by a single surgeon using a specifically
designed pre-contoured dorsally applied non-locking wrist arthrodesis
plate at a single centre. Aims
Patients and Methods
Large osteochondral lesions (OCLs) of the shoulder
of the talus cannot always be treated by traditional osteochondral
autograft techniques because of their size, articular geometry and
loss of an articular buttress. We hypothesised that they could be
treated by transplantation of a vascularised corticoperiosteal graft
from the ipsilateral medial femoral condyle. Between 2004 and 2011, we carried out a prospective study of
a consecutive series of 14 patients (five women, nine men; mean
age 34.8 years, 20 to 54) who were treated for an OCL with a vascularised
bone graft. Clinical outcome was assessed using a visual analogue
scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society
(AOFAS) hindfoot score. Radiological follow-up used plain radiographs
and CT scans to assess graft incorporation and joint deterioration. At a mean follow-up of 4.1 years (2 to 7), the mean VAS for pain
had decreased from 5.8 (5 to 8) to 1.8 (0 to 4) (p = 0.001) and
the mean AOFAS hindfoot score had increased from 65 (41 to 70) to
81 (54 to 92) (p = 0.003). Radiologically, the talar contour had
been successfully reconstructed with stable incorporation of the
vascularised corticoperiosteal graft in all patients. Joint degeneration
was only seen in one ankle. Treatment of a large OCL of the shoulder of the talus with a
vascularised corticoperiosteal graft taken from the medial condyle
of the femur was found to be a safe, reliable method of restoring
the contour of the talus in the early to mid-term. Cite this article:
This pilot study reports the clinical outcomes
of a combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty in patients with rotatator cuff arthropathy. A
total of 30 patients (30 shoulders; eight men and 22 women) with
a mean age of 74 years (55 to 84) were assessed at a mean follow-up
of 31 months (24 to 60). The inclusion criteria were painful cuff
tear arthropathy with normal deltoid function and a non-degenerative subscapularis
muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles
score, the Japanese Orthopaedic Association score, and the Oxford
Shoulder Score. Radiographic measurements included the centre of
rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively.
The active flexion and external rotation improved significantly
at the most recent follow-up (p <
0.035). Although the mean centre
of rotation distance changed significantly (p <
0.001), the mean
length of the deltoid did not change significantly from the pre-operative
value (p = 0.29). The change in the length of the deltoid with <
100° flexion was significantly less than that with >
100° (p <
0.001). Progressive erosion of the glenoid was seen in four patients.
No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty effectively restored function and relieved pain
in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5.
The February 2015 Knee Roundup360 looks at: Intra-operative sensors for knee balance; Mobile bearing no advantage; Death and knee replacement: a falling phenomenon; The swings and roundabouts of unicompartmental arthroplasty; Regulation, implants and innovation; The weight of arthroplasty responsibility!; BMI in arthroplasty
The February 2015 Wrist &
Hand Roundup360 looks at: Toes, feet, hands and transfers… FCR Tendonitis after Trapeziectomy and suspension, Motion sparing surgery for SLAC/SNAC wrists under the spotlight, Instability following distal radius fractures, Bilateral wrist arthrodesis a good idea?, Sodium Hyaluronate improves hand recovery following flexor tendon repair, Ultrasound treatments for de Quervain’s, Strategies for treating metacarpal neck fractures.
We undertook a retrospective cohort study to
determine clinical outcomes following the revision of metal-on-metal (MoM)
hip replacements for adverse reaction to metal debris (ARMD), and
to identify predictors of time to revision and outcomes following
revision. Between 1998 and 2012 a total of 64 MoM hips (mean age
at revision of 57.8 years; 46 (72%) female; 46 (72%) hip resurfacings
and 18 (28%) total hip replacements) were revised for ARMD at one specialist
centre. At a mean follow-up of 4.5 years (1.0 to 14.6) from revision
for ARMD there were 13 hips (20.3%) with post-operative complications
and eight (12.5%) requiring re-revision. The Kaplan–Meier five-year survival rate for ARMD revision was
87.9% (95% confidence interval 78.9 to 98.0; 19 hips at risk). Excluding
re-revisions, the median absolute Oxford hip score (OHS) following
ARMD revision using the percentage method (0% best outcome and 100%
worst outcome) was 18.8% (interquartile range (IQR) 7.8% to 48.3%),
which is equivalent to 39/48 (IQR 24.8/48 to 44.3/48) when using
the modified OHS. Histopathological response did not affect time
to revision for ARMD (p = 0.334) or the subsequent risk of re-revision
(p = 0.879). Similarly, the presence or absence of a contralateral
MoM hip bearing did not affect time to revision for ARMD (p = 0.066)
or the subsequent risk of re-revision (p = 0.178). Patients revised to MoM bearings had higher rates of re-revision
(five of 16 MoM hips re-revised; p = 0.046), but those not requiring
re-revision had good functional results (median absolute OHS 14.6%
or 41.0/48). Short-term morbidity following revision for ARMD was
comparable with previous reports. Caution should be exercised when choosing
bearing surfaces for ARMD revisions. Cite this article:
The December 2014 Knee Roundup360 looks at: national guidance on arthroplasty thromboprophylaxis is effective; unicompartmental knee replacement has the edge in terms of short-term complications; stiff knees, timing and manipulation; neuropathic pain and total knee replacement; synovial fluid α-defensin and CRP: a new gold standard in joint infection diagnosis?; how to assess anterior knee pain?; where is the evidence? Five new implants under the spotlight; and a fresh look at ACL reconstruction