Advertisement for orthosearch.org.uk
Results 1241 - 1260 of 3046
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 576 - 582
1 Jul 1997
Haddad FS Jones DHA Vellodi A Kane N Pitt MC

Children with a mucopolysaccharidosis or mucolipidosis suffer progressive disability of the hands, particularly in relation to dysfunction of the median nerve. This is an increasing problem because bone-marrow transplantation has dramatically improved survival without apparently changing the musculoskeletal manifestations. We have reviewed 48 children with these syndromes who required carpal tunnel decompression, recording symptoms, signs, radiological, electrophysiological and operative findings, histology and upper-limb function. In these children the carpal tunnel syndrome differs from that seen in adults. Symptoms are rare but signs such as decreased sweating, pulp atrophy, thenar wasting and manual clumsiness are much more common. At operation, the flexor retinaculum was thickened and a mass of white tenosynovium engulfed the flexor tendons. Most patients had some definite nerve constriction with a thickened epineurium. Functional improvement was seen after early decompression, with some benefit from simultaneous tendon release. Regular physiotherapy helped to maintain increased hand movement. We describe our assessment protocol, the physiotherapy and operative regime and the standard functional review which helps to maximise function in the hands and upper limbs of these children


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 3 - 9
1 Jan 2019
Alamanda VK Springer BD

Aims

Prosthetic joint infection (PJI) remains a serious complication that is associated with high morbidity and costs. The aim of this study was to prepare a systematic review to examine patient-related and perioperative risk factors that can be modified in an attempt to reduce the rate of PJI.

Materials and Methods

A search of PubMed and MEDLINE was conducted for articles published between January 1990 and February 2018 with a combination of search terms to identify studies that dealt with modifiable risk factors for reducing the rate of PJI. An evidence-based review was performed on 12 specific risk factors: glycaemic control, obesity, malnutrition, smoking, vitamin D levels, preoperative Staphylococcus aureus screening, the management of anti-rheumatic medication, perioperative antibiotic prophylaxis, presurgical skin preparation, the operating room environment, irrigant options, and anticoagulation.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1019 - 1024
1 Aug 2007
Hing CB Young DA Dalziel RE Bailey M Back DL Shimmin AJ

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing. There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5° (80° to 160°). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60). We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation


Bone & Joint 360
Vol. 7, Issue 5 | Pages 13 - 16
1 Oct 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 389 - 392
1 Apr 2003
Misra AN Hussain MRA Fiddian NJ Newton G

We randomised 129 knees which were to be replaced using a standard posterior-cruciate-ligament (PCL)-retaining cemented total knee replacement into two groups. In one the PCL was retained in the normal way and in the other it was resected. They were well matched, with a predominance of women, and a mean age of 67 years. There was no statistically significant difference in the Hospital for Special Surgery scores at a mean of 57 months (56 to 60) between the two groups although 21 patients (24 knees) were lost to follow-up. Relief from pain, correction of deformity, range of movement, stability and strength were comparable in both. Radiological assessment showed femoral rollback in approximately 20% of knees with a slightly higher incidence in the PCL-resected group. There was no significant loosening detected in either group at review at two years. At five years, one knee in the PCL-retained group had been revised because of infection and one patient in each group was awaiting revision for loosening. Our findings have shown no significant difference in the five-year results for a PCL-retaining total knee replacement if the PCL is excised or preserved. This suggests two important points. First, the PCL is not functional in most patients with a total knee replacement even when retained. Secondly, patients with an excised PCL show a good result with a PCL-retaining implant, thereby questioning the need for a posterior stabilised design in such a situation


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 620 - 624
1 Jul 1996
Williams CRP O’Flynn E Clarke NMP Morris RJ

We report a series of 15 children, six male and nine female, of average age 20 months, seen at a paediatric orthopaedic clinic with torticollis. Orthopaedic examination revealed a normal range of neck movement in all cases but in seven there was palpable tightness in the absence of true shortening or contracture of the sternomastoid muscle. The patients were prospectively referred for ocular examination. In five of the 15 an ocular cause for the torticollis was detected with underaction of the superior oblique muscle in three, paresis of the lateral rectus muscle in one and nystagmus in one. Another two patients were found to have an abnormal ocular examination which was thought to be unrelated to their torticollis. Three of the patients with ocular torticollis required extra-ocular muscle surgery to abolish the head tilt and one of these had a tight sternomastoid muscle. Two of the non-ocular group had surgical release of the sternomastoid muscle; in the rest, the condition either resolved with physiotherapy or required no active treatment. We recommend that all patients with torticollis and no clear orthopaedic cause are referred for ocular assessment since it is not possible clinically to distinguish ocular from non-ocular causes


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 15 - 21
1 Jan 2019
Kelly MJ Holton AE Cassar-Gheiti AJ Hanna SA Quinlan JF Molony DC

Aims

The glenohumeral joint is the most frequently dislocated articulation, but possibly due to the lower prevalence of posterior shoulder dislocations, approximately 50% to 79% of posterior glenohumeral dislocations are missed at initial presentation. The aim of this study was to systematically evaluate the most recent evidence involving the aetiology of posterior glenohumeral dislocations, as well as the diagnosis and treatment.

Materials and Methods

A systematic search was conducted using PubMed (MEDLINE), Web of Science, Embase, and Cochrane (January 1997 to September 2017), with references from articles also evaluated. Studies reporting patients who experienced an acute posterior glenohumeral joint subluxation and/or dislocation, as well as the aetiology of posterior glenohumeral dislocations, were included.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 41 - 46
1 Jan 2019
Clement ND Howard TA Immelman RJ MacDonald D Patton JT Lawson GM Burnett R

Aims

The primary aim of this study was to compare the knee-specific functional outcome of patellofemoral arthroplasty with total knee arthroplasty (TKA) in the management of patients with patellofemoral osteoarthritis.

Patients and Methods

A total of 54 consecutive Avon patellofemoral arthroplasties were identified and propensity-score-matched to a group of 54 patients undergoing a TKA with patellar resurfacing for patellofemoral osteoarthritis. The Oxford Knee Score (OKS), the 12-Item Short-Form Health Survey (SF-12), and patient satisfaction were collected at a mean follow up of 9.2 years (8 to 15). Survival was defined by revision or intention to revise.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 544 - 547
1 Jul 1994
Benjamin B Khan M

We reviewed 190 children with brucellosis admitted over a 7.8-year period. Seventy of these had articular involvement (36%) and the most common site was the hip (18%). All but one patient had unilateral infection. The hip was the only joint infected in 20 patients (57%). The next most common articular site was the knee. All patients had painful limitation of movement and this was the only articular sign in 28 (80%). Extra-articular signs included fever and hepatosplenomegaly. Brucella infection should be considered in every child from an endemic area who presents with fever and joint symptoms. The insidious onset and a normal or low leucocyte count help the differentiation from acute septic arthritis. Children with hip involvement had a slower response to treatment, longer hospital stays and a higher incidence of complications and relapse than those without. Complications included dislocation (n = 4) and avascular necrosis of the femoral head (n = 1). Treatment by combination chemotherapy for 6 to 12 weeks usually achieves cure and prevents relapse. A multidisciplinary team approach to management is recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1155 - 1160
1 Nov 2003
Yang KH Byun YS

Comminuted and displaced fractures of the inferior pole of the patella are not easy to reduce and it is difficult to fix the fragments soundly enough to allow early movement of the knee. We have evaluated the clinical effectiveness of the separate vertical wiring technique in acute comminuted fractures of the inferior pole of the patella. A biomechanical study was also performed using ten pairs of embalmed cadaver knees. A four-part fracture was made on the inferior pole of the patella and fixed by two separate vertical wires on one side and two pull-out sutures after partial patellectomy on the other. The ultimate load to failure in the first group was significantly higher than in the second (250.1± 109.7 N v 69.7 ± 18.9 N, p< 0.002), as was the stiffness (279.9 ± 76.4 N/mm v 23.2 ± 11.4 N/mm, p< 0.001). The separate wire technique was used in 25 patients with comminuted fractures of the inferior pole of the patella who were followed up for a mean period of 22 months (10 to 50). All the fractures healed at a mean of seven weeks (6 to 10). No breakage of a wire or infection occurred. The mean grading at the final follow-up was 29.5 points (27 to 30) using the Böstman method. This technique preserved the length of the patella, fixed the comminuted fragments of the inferior pole and avoided long-term immobilisation of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1067 - 1072
1 Nov 1998
Hall RM Siney P Wroblewski BM Unsworth A

The direction of wear in the acetabular socket has implications for the amount of debris that is generated during movement, for the magnitude of eccentric loading and for the incidence of impingement of the neck. We observed the direction of penetration with respect to a global co-ordinate system in 84 acetabular components retrieved at reoperation. The mean direction of wear relative to the open face of the sockets was found to be 37° with a range from 0° to 87°. For those values determined using the inclination of the socket on the prerevision radiograph, the mean direction of penetration in the coronal plane had a lateral, rather than a medial, component. The mean angle was 84° (SD 17°) with respect to the horizontal. The angle of penetration was found to correlate significantly with the depth, in that the lateral component became larger as the wear progressed. There was also a significant correlation between the rate of penetration and the direction of wear. Despite the theoretical advantage of penetration in the superolateral direction, i.e., along the margin of the socket, in reducing the probability of impingement of the neck, no significant correlation was seen between the angle of penetration and the period of use in vivo. This may suggest that impingement of the femoral neck on the rim of the socket may not be the dominant factor in loosening of the socket but can still be important in a few cases


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1070 - 1074
1 Sep 2002
Dumont CE Thalmann R Macy JC

We have assessed the influence of isolated and combined rotational malunion of the radius and ulna on the rotation of the forearm. Osteotomies were made in both the radius and the ulna at the mid-diaphyseal level of five cadaver forearms and stabilised with intramedullary metal implants. Malunion about the axis of the respective forearm bone was produced at intervals of 10°. The ranges of pronation and supination were recorded by a potentiometer under computer control. We examined rotational malunions of 10° to 80° of either the radius or ulna alone and combined rotational malunions of 20° to 60° of both the radius and ulna. Malunion of the ulna in supination had little effect on rotation of the forearm. Malunion of either the radius or of the ulna in pronation gave a moderate reduction of rotation of the forearm. By contrast, malunion of the radius in supination markedly reduced rotation of the forearm, especially with malunion greater than 60°. Combined rotational malunion produced contrasting results. A combination of rotational malunion of the radius and ulna in the same direction had an effect similar to that of an isolated malunion of the radius. A combination in the opposite direction gave the largest limitation of the range of movement. Clinically, rotational malunion may be isolated or part of a complex angular/rotational deformity and rotational malunion may lead to marked impairment of rotation of the forearm. A reproducible method for assessing rotational malunion is therefore needed


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1264 - 1269
1 Oct 2018
Thomas AM Simmons MJ

Deep infection was identified as a serious complication in the earliest days of total hip arthroplasty. It was identified that airborne contamination in conventional operating theatres was the major contributing factor. As progress was made in improving the engineering of operating theatres, airborne contamination was reduced. Detailed studies were carried out relating airborne contamination to deep infection rates.

In a trial conducted by the United Kingdom Medical Research Council (MRC), it was found that the use of ultra-clean air (UCA) operating theatres was associated with a significant reduction in deep infection rates. Deep infection rates were further reduced by the use of a body exhaust system. The MRC trial also included a detailed microbiology study, which confirmed the relationship between airborne contamination and deep infection rates.

Recent observational evidence from joint registries has shown that in contemporary practice, infection rates remain a problem, and may be getting worse. Registry observations have also called into question the value of “laminar flow” operating theatres.

Observational evidence from joint registries provides very limited evidence on the efficacy of UCA operating theatres. Although there have been some changes in surgical practice in recent years, the conclusions of the MRC trial remain valid, and the use of UCA is essential in preventing deep infection.

There is evidence that if UCA operating theatres are not used correctly, they may have poor microbiological performance. Current UCA operating theatres have limitations, and further research is required to update them and improve their microbiological performance in contemporary practice.

Cite this article: Bone Joint J 2018;100-B:1264–9.


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives

The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction.

Materials and Methods

This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (sd 5.2) vs 67.5 years (sd 5.8) (p = 0.25); body mass index (27.4 kg/m2 (sd 2.1) vs 26.9 kg/m2 (sd 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs.


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 46 - 52
1 Jan 2019
León SA Mei XY Safir OA Gross AE Kuzyk PR

Aims

The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function.

Patients and Methods

We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 402 - 405
1 May 1991
Zuckerman J Leblanc J Choueka J Kummer F

A cadaver study was performed to determine the effect of arm position and capsular release on rotator cuff repair. Artificial defects were made in the rotator cuff to include only the supraspinatus (small) or both supraspinatus and infraspinatus (large). The defects were repaired in a standard manner with the shoulder abducted 30 degrees at the glenohumeral joint. Strain gauges were placed on the lateral cortex of the greater tuberosity and measurements were recorded in 36 different combinations of abduction, flexion/extension, and medial/lateral rotation. Readings were obtained before and after capsular release. With small tears, tension in the repair increased significantly with movement from 30 degrees to 15 degrees of abduction (p < 0.01) but was minimally affected by changes in flexion or rotation. Capsular release significantly reduced the force (p < 0.01) at 0 degree and 15 degrees abduction. For large tears, abduction of 30 degrees or more with lateral rotation and extension consistently produced the lowest values. Capsular release resulted in 30% less force at 0 degree abduction (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 549 - 553
1 Jul 1990
Bickerstaff D Neal L Booth A Brennan P Bell M

We made a prospective study of 111 children with acute hip pain to assess whether ultrasound can replace traditional radiography. An effusion was diagnosed in 71% by ultrasound but in only 15% by radiography. This effusion persisted for a mean of nine days; symptoms lasted for five days. Two patients found to have Perthes' disease had longer-lasting effusion and symptoms. Patients without an effusion had no obvious cause for their pain, so the pressure of an effusion from a transient synovitis does not account for all patients with irritable hips. Patients with an effusion persisting for over 24 days (the mean + 2 s.d. of our series) had more symptoms, a significantly larger effusion and greater limitation of movement. They may be more at risk for avascular necrosis. We found that radiographic examination influenced the immediate management of only two patients, those with Perthes' disease. We therefore propose a protocol of management for irritable hip, using ultrasonography at the first presentation of certain categories of patients. This would reduce the number of early radiographs by 75%


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 351 - 359
1 Mar 1998
Lund T Oxland TR Jost B Cripton P Grassmann S Etter C Nolte L

We performed a biomechanical study on human cadaver spines to determine the effect of three different interbody cage designs, with and without posterior instrumentation, on the three-dimensional flexibility of the spine. Six lumbar functional spinal units for each cage type were subjected to multidirectional flexibility testing in four different configurations: intact, with interbody cages from a posterior approach, with additional posterior instrumentation, and with cross-bracing. The tests involved the application of flexion and extension, bilateral axial rotation and bilateral lateral bending pure moments. The relative movements between the vertebrae were recorded by an optoelectronic camera system. We found no significant difference in the stabilising potential of the three cage designs. The cages used alone significantly decreased the intervertebral movement in flexion and lateral bending, but no stabilisation was achieved in either extension or axial rotation. For all types of cage, the greatest stabilisation in flexion and extension and lateral bending was achieved by the addition of posterior transpedicular instrumentation. The addition of cross-bracing to the posterior instrumentation had a stabilising effect on axial rotation. The bone density of the adjacent vertebral bodies was a significant factor for stabilisation in flexion and extension and in lateral bending


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 537 - 538
1 Jul 1997
Hill JM McGuire MH Crosby LA

We evaluated 242 consecutive fractures of the clavicle in adults which had been treated conservatively. Of these, 66 (27%) were originally in the middle third of the clavicle and had been completely displaced. We reviewed 52 of these patients at a mean of 38 months after injury. Eight of the 52 fractures (15%) had developed nonunion, and 16 patients (31%) reported unsatisfactory results. Thirteen patients had mild to moderate residual pain and 15 had some evidence of brachial plexus irritation. Of the 28 who had cosmetic complaints, only 11 considered accepting corrective surgery. No patient had significant impairment of range of movement or shoulder strength as a result of the injury. We found that initial shortening at the fracture of ≥20 mm had a highly significant association with nonunion (p < 0.0001) and the chance of an unsatisfactory result. Final shortening of 20 mm or more was associated with an unsatisfactory result, but not with nonunion. No other patient variable, treatment factor, or fracture characteristic had a significant effect on outcome. We now recommend open reduction and internal fixation of severely displaced fractures of the middle third of the clavicle in adult patients


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 3 | Pages 546 - 549
1 Aug 1959
Robb WAT

1. The method of treatment of a mallet finger deformity by immobilisation in a plaster in the position of hyperextension of the distal interphalangeal joint and flexion of the proximal interphalangeal joint is, on the whole, unsatisfactory because the splint is difficult to apply, it may need to be changed frequently, and it is sometimes complicated by pressure sores. 2. In many cases the deformity is still present after six weeks of adequate immobilisation, but gradual improvement from the contraction of fibrous tissue occurs for up to six months. Therefore an assessment of the results of any method of treatment should be made only after an interval of at least six months. 3. The subjective end results at the end of six months are satisfactory whether or not there has been efficient immobilisation in hyperextension. Few patients have any disability and only rarely is this sufficient to cause interference with normal activities. A high proportion of patients show slight persistent deformity and limitation of movement, and this is seemingly uninfluenced appreciably by the type or duration of treatment. 4. The only treatment necessary for most cases of mallet finger is the application of elastic adhesive strapping or a straight spatula splint in order to relieve the initial discomfort from the injury