A new technique for the transthoracic removal of a prolapsed intervertebral disc in the mid or lower thoracic spine is described. Investigations before operation include thoracic myelography, selective spinal angiography and CT scanning. Image intensification is used at operation to check the level of the prolapse. A tunnel in the coronal plane (vertebrotomy) is made through the posterolateral part of the disc and the adjacent vertebral bodies, to reach the spinal canal at the site of the prolapse. This gives good exposure and enables gentle removal of the disc prolapse and any associated osteophytes, under direct vision without need for retraction or pressure on the dura or spinal cord. Spinal
Seventy-eight patients who had been operated on for bony entrapment of lumbar nerve roots were studied in an attempt to define the clinical syndrome, and to assess the results of a new technique of decompression which preserves spinal
The costo-clavicular ligament is always ruptured in dislocation at the sterno-clavicular joint. Anterior, superior or posterior displacement of the medial end of the clavicle may occur. Acute dislocation usually responds to conservative treatment and operation is seldom required. Chronic, or recurrent, dislocation may cause pain and disability on strenuous activity and necessitate surgical treatment. The operation of tenodesis of the subclavius tendon with capsulorrhaphy described by Burrows (1951) has been adopted. The intraarticular meniscus is often damaged and displaced, and may block reduction; its removal is then necessary. In addition, a threaded Steinmann pin transfixing the joint has been found useful to maintain the
Seventy-two posterior psoas transfer operations performed in forty-four children with lumbar myelomeningocele were reviewed one to eight years after operation in an attempt to assess its value. Muscle charting, an objective recording of the child's walking ability, and radiographic examination of the hips were done. Hip
1. The clinical experience of fourteen cases of traumatic spondylolisthesis of the axis is described. 2. Evidence is presented which suggests that vertical compression and extension forces are frequently involved. 3. Treatment is based on recognition of the deforming force and its extent. 4. Primary treatment of unstable lesions by the coronally placed bone dowel of Barbour allows early stabilisation and long-term security. 5. The increased antero-posterior diameter of the axis explains the low incidence of spinal cord damage. 6. Skull traction is considered illogical in that it runs parallel in effect to the most deadly form of judicial hanging. 7. Secondary
1. The technique of the intra-articular surgery employed by the late Mr K. H. Pridie for osteoarthritis of the knee is described. 2. The results of sixty-two operations in sixty patients are analysed. The results in forty-eight knees (77 per cent) were pleasing to the patient. Forty knees (64 per cent) were rated as good at review. 3. The operation is most suitable for relatively active healthy people whose disability warrants a comparatively painful operation and lengthy rehabilitation. 4. The operation was most successful for relieving pain and improving
1. A small personal consecutive series of children with congenital dislocation or subluxation of the hip who came for treatment at the age of over three years has been reviewed. The children have been kept under review up to the age of ten years or more. 2. A number of late results are illustrated. They lead to the conclusion that open operation is indicated in all these cases and that acetabuloplasty will effectively provide
1. The early results of thirty Austin Moore arthroplasty operations with acetabular reaming in twenty-five patients with advanced osteoarthritis of the hip have been investigated. 2. The radiological changes after insertion of a prosthesis have been studied. 3. There was a variable degree of improvement in all patients. There was a worth-while improvement in function and relief of pain.
Three palmar wrist ligaments from fresh human cadavers were dissected from the proximal to the distal insertions and stained to identify the mechanoreceptors. Golgi organs, Pacinian corpuscles, Ruffini endings and free nerve endings were present in all three ligaments. In the radial collateral and radiolunate ligaments they were found in increased density towards the proximal and distal insertions. A more uniform distribution was found in the radioscaphocapitate ligament which has attachments to three bones. The palmar wrist ligaments may have a significant sensory role in maintaining the
Adult human cadaver pelves were tested to determine micromotion at the prosthesis-bone interface in cementless hemispherical acetabular components during simulated single-limb stance. The micromotion of non-press-fit components with screw fixation in response to cyclic loads to a maximum of 1500N was compressive (interface closing) at the superior iliac rim and distractive (interface opening) at the inferior ischial rim; that of press-fit components was compressive all around the acetabular rim regardless of screw fixation. Adding screws to the component decreased the micromotion at the site of the screw, but sometimes increased it at the opposite side. Two dome screws with the press-fit component decreased the micromotion at the superior iliac rim but at the inferior ischial rim there was either no change or increased movement. A press-fit cup shows less micromotion than a non-press-fit cup with screw fixation. The addition of screws to a press-fit cup does not necessarily increase the initial
This study reviews the use of a titanium mesh cage (TMC) as an
adjunct to intramedullary nail or plate reconstruction of an extra-articular
segmental long bone defect. A total of 17 patients (aged 17 to 61 years) treated for a segmental
long bone defect by nail or plate fixation and an adjunctive TMC
were included. The bone defects treated were in the tibia (nine),
femur (six), radius (one), and humerus (one). The mean length of
the segmental bone defect was 8.4 cm (2.2 to 13); the mean length
of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and
radiological records of the patients were analyzed retrospectively.Aims
Patients and Methods
Several methods of measuring the migration of the femoral component after total hip replacement have been described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible. We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Röntgen-Analyse) to determine its accuracy using three independent assessments, including a direct comparison with the results of roentgen stereophotogrammetric analysis (RSA). The accuracy of EBRA-FCA was better than ±1.5 mm (95% percentile) with a Cronbach’s coefficient alpha for interobserver reliability of 0.84; a very good result. The method had a specificity of 100% and a sensitivity of 78% compared with RSA for the detection of migration of over 1 mm. This is accurate enough to assess the
This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.Aims
Patients and Methods
This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg–Marquardt algorithm.Aims
Patients and Methods
We treated 21 patients with 22 dislocations of the knee by repair or reconstruction of all injured ligaments. Eight knees were treated in the acute phase (less than two weeks after injury); the remainder were treated more than six months after injury (6 to 72). Reconstructions were carried out with a combination of autograft and allograft tendons and by direct ligament repair where possible. At a mean follow-up of 32 months (11 to 77) the mean Lysholm score was 87 (81 to 91) in the acute group and 75 (53 to 100) in the delayed group. The mean Tegner activity rating was 5 in the acute group and 4.4 in the delayed group. The International Knee Documentation Committee assessment revealed no differences between the two groups. Instrumented testing of knee
Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent
We reviewed 134 primary noncemented porous-coated total hip replacements in 125 patients: 64 were DePuy AML prostheses, 20 were Howmedica PCA and 50 were Implant Technology LSF. The prostheses had been in situ for an average of 36 months, 40 months and 24 months respectively. The average pre-operative Harris hip scores were 38.2 for AML, 33.2 for PCA, and 41.0 for the LSF prostheses. The average postoperative scores were 80.7 for AML, 83.8 for the PCA, and 91.5 for LSF. Thigh or groin pain associated with the prosthesis was present in 30% of AML, 30% PCA and 8% of the LSF cases. The clinical and radiographic review showed better early results with the LSF prostheses than the others; this seemed to be related to the implant design, which provided improved initial
The treatment of osteochondritis dissecans (OCD) in children and adolescents is determined by the
1. Stainless steel mould arthroplasty of the knee is described and a ten-year follow-up study of sixty-two operations is reported. Fifty-four were for rheumatoid arthritis and eight for osteoarthritis. 2. Forty-nine of the sixty-two joints retained mobility, six had become ankylosed and five were later arthrodesed ; two limbs were amputated. The forty-nine mobile knees included twenty-seven which were painless at all times, and fourteen in which only an occasional twinge was felt. 3. The range of movement was increased in twenty-two joints as compared with the state before operation, diminished in twelve and unaltered in five. In ten knees measurements before operation were not available. 4. Flexion deformity, swelling,