Advertisement for orthosearch.org.uk
Results 1221 - 1240 of 2553
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 518 - 522
1 Aug 1984
Fidler M Goedhart Z

A new technique for the transthoracic removal of a prolapsed intervertebral disc in the mid or lower thoracic spine is described. Investigations before operation include thoracic myelography, selective spinal angiography and CT scanning. Image intensification is used at operation to check the level of the prolapse. A tunnel in the coronal plane (vertebrotomy) is made through the posterolateral part of the disc and the adjacent vertebral bodies, to reach the spinal canal at the site of the prolapse. This gives good exposure and enables gentle removal of the disc prolapse and any associated osteophytes, under direct vision without need for retraction or pressure on the dura or spinal cord. Spinal stability is not compromised, and the blood supply of the cord is not disturbed. Five consecutive patients are reported, including one in whom the disc prolapse was calcified and had herniated into the spinal cord. All were treated successfully


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 330 - 335
1 Aug 1981
Getty C Johnson Kirwan E Sullivan M

Seventy-eight patients who had been operated on for bony entrapment of lumbar nerve roots were studied in an attempt to define the clinical syndrome, and to assess the results of a new technique of decompression which preserves spinal stability. The mean age of the patients was 45 years and 28 of them had previously undergone spinal operations. Pain in the leg was the predominant symptom, with evidence of motor involvement in half of the patients. Signs of nerve root tension were found in only one-third of the patients. The principal factor in the aetiology was degenerative change in the posterior facet joints. Decompression was achieved by a partial undercutting facetectomy. Fifty-nine per cent of the patients obtained a "good" result and 85 per cent were satisfied with the result of their operation. Successful partial facetectomy for bony entrapment of lumbar nerve roots produced rapid and lasting relief of pain


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 193 - 196
1 May 1975
Lunseth PA Chapman KW Frankel VH

The costo-clavicular ligament is always ruptured in dislocation at the sterno-clavicular joint. Anterior, superior or posterior displacement of the medial end of the clavicle may occur. Acute dislocation usually responds to conservative treatment and operation is seldom required. Chronic, or recurrent, dislocation may cause pain and disability on strenuous activity and necessitate surgical treatment. The operation of tenodesis of the subclavius tendon with capsulorrhaphy described by Burrows (1951) has been adopted. The intraarticular meniscus is often damaged and displaced, and may block reduction; its removal is then necessary. In addition, a threaded Steinmann pin transfixing the joint has been found useful to maintain the stability of reduction. The operation has been performed on five patients, four of whom had excellent results. The fifth patient disrupted the repair in a drinking bout shortly after the operation


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 1 | Pages 53 - 58
1 Feb 1975
Parker B Walker G

Seventy-two posterior psoas transfer operations performed in forty-four children with lumbar myelomeningocele were reviewed one to eight years after operation in an attempt to assess its value. Muscle charting, an objective recording of the child's walking ability, and radiographic examination of the hips were done. Hip stability was improved: 49 per cent were stable at the time of psoas transfer and 94 per cent at review. Functional results depended mainly on the level of neurological activity present: 57 per cent of the children had an acceptable functional result. Usually, posterior psoas transfer should be done as soon after the age of nine months as the child's condition will allow. Over the age of two years it should be restricted to children with activity in the third and fourth segments of the lumbar cord


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 31 - 43
1 Feb 1968
Cornish BL

1. The clinical experience of fourteen cases of traumatic spondylolisthesis of the axis is described. 2. Evidence is presented which suggests that vertical compression and extension forces are frequently involved. 3. Treatment is based on recognition of the deforming force and its extent. 4. Primary treatment of unstable lesions by the coronally placed bone dowel of Barbour allows early stabilisation and long-term security. 5. The increased antero-posterior diameter of the axis explains the low incidence of spinal cord damage. 6. Skull traction is considered illogical in that it runs parallel in effect to the most deadly form of judicial hanging. 7. Secondary stability following injury may allow continuing force to fracture the spine at other levels. 8. The paradox of an extension injury between the second and third cervical vertebrae and a "flexion" injury at a lower level is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 2 | Pages 211 - 228
1 May 1967
Insall JN

1. The technique of the intra-articular surgery employed by the late Mr K. H. Pridie for osteoarthritis of the knee is described. 2. The results of sixty-two operations in sixty patients are analysed. The results in forty-eight knees (77 per cent) were pleasing to the patient. Forty knees (64 per cent) were rated as good at review. 3. The operation is most suitable for relatively active healthy people whose disability warrants a comparatively painful operation and lengthy rehabilitation. 4. The operation was most successful for relieving pain and improving stability. Functional improvement was less. 5. Results were remarkably permanent. The knees showed little tendency towards further deterioration. 6. Most of the bad results were associated with removal of the patella. A possible technical reason for this has been discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 4 | Pages 682 - 692
1 Nov 1966
Eyre-Brook AL

1. A small personal consecutive series of children with congenital dislocation or subluxation of the hip who came for treatment at the age of over three years has been reviewed. The children have been kept under review up to the age of ten years or more. 2. A number of late results are illustrated. They lead to the conclusion that open operation is indicated in all these cases and that acetabuloplasty will effectively provide stability in most, particularly when combined with osteotomy of the femur with adduction angulation and lateral rotation. 3. It is still too early to assess the value of pelvic osteotomy of the Salter (1961) or Chiari (1955) type. 4. Capsular arthroplasty appears from Trevor's (1960) considerable experience to have a valuable place in patients over six years old


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 236 - 244
1 May 1966
Heywood-Waddington MB

1. The early results of thirty Austin Moore arthroplasty operations with acetabular reaming in twenty-five patients with advanced osteoarthritis of the hip have been investigated. 2. The radiological changes after insertion of a prosthesis have been studied. 3. There was a variable degree of improvement in all patients. There was a worth-while improvement in function and relief of pain. Stability, however, was disappointing in more than half (and in all the bilateral cases). An average of three-quarters of an inch of shortening was found in the unilateral cases. 4. In such advanced cases the results of Austin Moore arthroplasty are probably of the same order as for cup arthroplasty, and in many cases they show no more than marginal improvement over pseudarthrosis. 5. It is concluded that at the present stage of progress in the development of arthroplasty the use of the Austin Moore prosthesis with acetabular reaming has very limited indications


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 494 - 496
1 May 1997
Petrie S Collins J Solomonow M Wink C Chuinard R

Three palmar wrist ligaments from fresh human cadavers were dissected from the proximal to the distal insertions and stained to identify the mechanoreceptors. Golgi organs, Pacinian corpuscles, Ruffini endings and free nerve endings were present in all three ligaments. In the radial collateral and radiolunate ligaments they were found in increased density towards the proximal and distal insertions. A more uniform distribution was found in the radioscaphocapitate ligament which has attachments to three bones. The palmar wrist ligaments may have a significant sensory role in maintaining the stability of the wrist and in controlling its movement. Although technically difficult, the surgical repair of traumatic wrist defects should attempt to preserve the innervation of the ligaments, shown to be mainly near bony attachments. This may allow improvement in postoperative outcomes by preserving some proprioception. In some painful post-traumatic or degenerative conditions, however, denervation may be advantageous


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 484 - 489
1 May 1995
Won C Hearn T Tile M

Adult human cadaver pelves were tested to determine micromotion at the prosthesis-bone interface in cementless hemispherical acetabular components during simulated single-limb stance. The micromotion of non-press-fit components with screw fixation in response to cyclic loads to a maximum of 1500N was compressive (interface closing) at the superior iliac rim and distractive (interface opening) at the inferior ischial rim; that of press-fit components was compressive all around the acetabular rim regardless of screw fixation. Adding screws to the component decreased the micromotion at the site of the screw, but sometimes increased it at the opposite side. Two dome screws with the press-fit component decreased the micromotion at the superior iliac rim but at the inferior ischial rim there was either no change or increased movement. A press-fit cup shows less micromotion than a non-press-fit cup with screw fixation. The addition of screws to a press-fit cup does not necessarily increase the initial stability


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 266 - 272
1 Mar 1999
Biedermann R Krismer M Stöckl B Mayrhofer P Ornstein E Franzén H

Several methods of measuring the migration of the femoral component after total hip replacement have been described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible. We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Röntgen-Analyse) to determine its accuracy using three independent assessments, including a direct comparison with the results of roentgen stereophotogrammetric analysis (RSA). The accuracy of EBRA-FCA was better than ±1.5 mm (95% percentile) with a Cronbach’s coefficient alpha for interobserver reliability of 0.84; a very good result. The method had a specificity of 100% and a sensitivity of 78% compared with RSA for the detection of migration of over 1 mm. This is accurate enough to assess the stability of a prosthesis within a relatively limited period. The best reference line for downward migration is between the greater trochanter and the shoulder of the stem, as confirmed by two experimental analyses and a computer-assisted design


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1336 - 1344
1 Oct 2018
Powell AJ Crua E Chong BC Gordon R McAuslan A Pitto RP Clatworthy MG

Aims

This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study.

Patients and Methods

A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1280 - 1288
1 Oct 2018
Grammatopoulos G Gofton W Cochran M Dobransky J Carli A Abdelbary H Gill HS Beaulé PE

Aims

This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions.

Patients and Methods

The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg–Marquardt algorithm.


Bone & Joint Research
Vol. 7, Issue 5 | Pages 325 - 326
1 May 2018
Clement ND Deehan DJ


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 845 - 851
1 Aug 2003
Liow RYL McNicholas MJ Keating JF Nutton RW

We treated 21 patients with 22 dislocations of the knee by repair or reconstruction of all injured ligaments. Eight knees were treated in the acute phase (less than two weeks after injury); the remainder were treated more than six months after injury (6 to 72). Reconstructions were carried out with a combination of autograft and allograft tendons and by direct ligament repair where possible. At a mean follow-up of 32 months (11 to 77) the mean Lysholm score was 87 (81 to 91) in the acute group and 75 (53 to 100) in the delayed group. The mean Tegner activity rating was 5 in the acute group and 4.4 in the delayed group. The International Knee Documentation Committee assessment revealed no differences between the two groups. Instrumented testing of knee stability indicated better results for anterior cruciate ligament reconstructions which had been undertaken in the acute phase, but no difference in the outcome of posterior cruciate ligament reconstructions. There was no difference in the loss of knee movement between the two groups. Although the differences were small, the outcome in terms of overall knee function, activity levels and anterior tibial translation were better in those knees which had been reconstructed within two weeks of injury


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 448 - 451
1 May 1991
Thakur A Patankar J

Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early bone grafting through a posterolateral approach. The external fixator was dynamised as soon as periosteal callus was seen on the radiograph. Bone healing times ranged from 11 to 40 weeks (mean 20). Significant ankle stiffness occurred in 10.9% and leg shortening in 2.8%. Pin track infection was seen in 45.2% but was easily controlled with standard management. The external fixation frame allowed excellent functional freedom for Oriental patients to sit cross-legged and squat. Combined with early bone grafting, external fixation is an excellent method for the management of open tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 2 - 8
1 Jan 1990
Haddad R Cook S Brinker M

We reviewed 134 primary noncemented porous-coated total hip replacements in 125 patients: 64 were DePuy AML prostheses, 20 were Howmedica PCA and 50 were Implant Technology LSF. The prostheses had been in situ for an average of 36 months, 40 months and 24 months respectively. The average pre-operative Harris hip scores were 38.2 for AML, 33.2 for PCA, and 41.0 for the LSF prostheses. The average postoperative scores were 80.7 for AML, 83.8 for the PCA, and 91.5 for LSF. Thigh or groin pain associated with the prosthesis was present in 30% of AML, 30% PCA and 8% of the LSF cases. The clinical and radiographic review showed better early results with the LSF prostheses than the others; this seemed to be related to the implant design, which provided improved initial stability and more physiological transfer of load


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 258 - 262
1 Mar 2002
O’Connor MA Palaniappan M Khan N Bruce CE

The treatment of osteochondritis dissecans (OCD) in children and adolescents is determined by the stability of the lesion and the state of the overlying cartilage. MRI has been advocated as an accurate way of assessing and staging such lesions. Our aim was to determine if MRI scans accurately predicted the subsequent arthroscopic findings in adolescents with OCD of the knee. Some authors have suggested that a high signal line behind a fragment on the T2-weighted image indicates the presence of synovial fluid and is a sign of an unstable lesion. More recent reports have suggested that this high signal line is due to the presence of vascular granulation tissue and may represent a healing reaction. We were able to improve the accuracy of MRI for staging the OCD lesion from 45% to 85% by interpreting the high signal T2 line as a predictor of instability only when it was accompanied by a breach in the cartilage on the T1-weighted image. We conclude that MRI can be used to stage OCD lesions accurately and that a high signal line behind the OCD fragment does not always indicate instability. We recommend the use of an MRI classification system which correlates with the arthroscopic findings


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 76 - 87
1 Feb 1969
Platt G Pepler C

1. Stainless steel mould arthroplasty of the knee is described and a ten-year follow-up study of sixty-two operations is reported. Fifty-four were for rheumatoid arthritis and eight for osteoarthritis. 2. Forty-nine of the sixty-two joints retained mobility, six had become ankylosed and five were later arthrodesed ; two limbs were amputated. The forty-nine mobile knees included twenty-seven which were painless at all times, and fourteen in which only an occasional twinge was felt. 3. The range of movement was increased in twenty-two joints as compared with the state before operation, diminished in twelve and unaltered in five. In ten knees measurements before operation were not available. 4. Flexion deformity, swelling, stability and function were improved in a significant number of joints. 5. Patients suffering from active rheumatoid arthritis often found that the joint operated upon no longer took part in generalised flares of the disease