The anterior cruciate ligament was replaced in rabbits, using implants of carbon or polyester filaments with known mechanical properties. The biocompatibility of the implants was assessed in detail using light microscopy, and scanning and transmission electron microscopy. Mechanical tests were made of
We have reviewed 42 of 52 consecutive patients at an average of 14 years after a tenodesis based on Evans' operation performed for chronic lateral instability of the ankle. Only 21 patients (50%) had satisfactory long-term functional results, and 12 patients with satisfactory early results had deteriorated after three to six years. Stress radiographs were used to measure anterior talar translation and talar tilt, and a good correlation was found between function and mechanical
The role of atmospheric pressure in providing static
Eleven patients with metastases in the cervical spine had operations for severe pain due to a pathological fracture which, in eight of the cases, was unstable. Conservative treatment had either failed or was unsuitable. In the first five patients internal fixation with tension band wires and bone grafts was supported by a halo-brace. The method has evolved to the use of posterior instrumentation with laminar wires from two levels above the lesion to two levels below.
We treated 120 children between the ages of 12 and 31 months with 137 developmental dislocations of the hip and reviewed them at a mean follow-up of 14 years. We had used two-directional arthrography of all hips before reduction to evaluate the anterior, superior, and posterior portions of the limbus. Of the 137 hips, 64 had no interposed limbus in the AP view of the arthrogram, but 45 of these had an interposed anterior or posterior portion of the limbus. The hips with good
1. The results have been reviewed of forty-two traumatic dislocations of the knee in forty-one patients, twenty-six of which were treated conservatively. 2. Primary operative repair was carried out in only three cases, although a further ten had operative intervention for various complications. 3. It was not possible to compare the results of operation with those of conservative treatment, because the operative procedures were so diverse in nature. 4. The conservative treatment of twenty-six dislocations yielded surprisingly good results with regard to
1. A concept and design of polycentric knee arthroplasty based on the biomechanics of normal knee movement is presented. The diseased articular surfaces of the femoral condyles and tibial plateaus are replaced separately by prosthetic implants secured with cement. The collateral and cruciate ligaments are retained to maintain joint
1. Grafts of joint cartilage from immature lambs were used to repair articular cartilage defects in other lambs and in adult sheep. 2.
1. Twenty-two dislocations of the hip occurring in patients paralysed from an early age have been studied. All showed abnormal coxa valga. The coxa valga, which may gradually reach 180 degrees, precedes dislocation and makes it inevitable. The presence of unbalanced adductor power may hasten dislocation, but the latter can occur in complete flaccid paralysis. 2. The combination of structural instability of the hip joint and muscular weakness may make independent walking impossible, but restoration of
The classical longitudinal incision used for the direct anterior
approach (DAA) to the hip does not follow the tension lines of the
skin and can lead to impaired wound healing and poor cosmesis. The
purpose of this retrospective study was to determine the satisfaction
with the scar, and functional and radiographic outcomes comparing
the classic longitudinal incision with a modified skin crease ‘bikini’
when the DAA is used for total hip arthroplasty (THA). A total of 964 patients (51% female; 59% longitudinal, 41% ‘bikini’)
completed a follow-up questionnaire between two and four years postoperatively,
including the Oxford Hip Score (OHS), the University of North Carolina
‘4P’ scar scale (UNC4P) and two items for assessing the aesthetic
appearance of the scar and symptoms of numbness. The positioning
of the components, rates of heterotopic ossification (HO) and rates
of revision were assessed.Aims
Patients and Methods
The Norway elbow prosthesis is a non-constrained cemented total replacement. It depends on intact collateral ligaments for
This study presents the long-term survivorship, risk factors for prosthesis survival, and an assessment of the long-term effects of changes in surgical technique in a large series of patients treated by metal-on-metal (MoM) hip resurfacing arthroplasty (HRA). Between November 1996 and January 2012, 1074 patients (1321 hips) underwent HRA using the Conserve Plus Hip Resurfacing System. There were 787 men (73%) and 287 women (27%) with a mean age of 51 years (14 to 83). The underlying pathology was osteoarthritis (OA) in 1003 (75.9%), developmental dysplasia of the hip (DDH) in 136 (10.3%), avascular necrosis in 98 (7.4%), and other conditions, including inflammatory arthritis, in 84 (6.4%).Aims
Patients and Methods
The rigidity of a sliding compression screw and three cannulated lag screws in the treatment of subcapital fractures was compared in five pairs of female cadaver femora. There were no significant differences between the compressive strength, bone density, cortical thickness or Singh index of the bones in each pair. A subcapital fracture was standardised using a perpendicular saw cut across the femoral neck. A uniaxial 'load test system' with force and length measurement facilities was used to mimic cyclical stressing applied in vivo at a frequency of 0.5 Hz from 0 to 3 times body-weight. There was no significant difference between the fixation afforded by the sliding compression screw and three lag screws. Bone quality was the single most important factor in the
We report the use of a free tendon graft in 70 patients to repair lesions of the capsuloligamentous complex of the metacarpophalangeal joint of the thumb. Of these 37 had a lesion of the ulnar collateral ligament, 18 of the radial collateral and 11 of the volar plate. Four patients had combined lesions. We outline our techniques and review 51 of the patients. Of those 47 (92%) were satisfied, and all but one had regained full
Sixty-three knees with chronic ligamentous instability treated with flexible carbon fibre are reviewed. Assessment was by pre-operative and postoperative grading of function in work and sport, together with a subjective evaluation of the result based on
In a series of seventeen patients with unilateral osteoarthritis of the hip a scintiscanning follow-up study was made before and after total hip replacement for the assessment of the normal course of the 87mSr-scintiscan. In another series of twenty-eight patients with total hip replacement a photoscan was made as a supplement for the diagnosis of loosening of one or both components of a total hip implant. In most of these cases it proved to be a useful method, especially when clinical and raidological examination was inconclusive. It is concluded that up to six months after operation increased osteoblastic activity exists; the scintiscan became normal after that time. 87mSr scintiscanning offers a safe and simple technique for the assessment of the success and
The results of 110 operations for the treatment of fractures through metastases in the femoral neck and intertrochanteric region have been studied. Of these, forty-four fractures were treated by internal fixation, forty-six by resection of the femoral head and neck, and twenty by prosthetic replacement. The following conclusions were reached. 1. Prosthetic replacement of the femoral head is a reliable procedure. 2. The long stem type of prosthesis has the advantages of greater
We reviewed our experience with a modified triple innominate osteotomy for hip instability and limb shortening due to poliomyelitis in 62 adolescent and adult patients, treated from 1973 to 1990. Their ages at surgery ranged from 12 years to 35 years (average 22.3). At a mean follow-up of 4 years (2 to 18) 59 of the patients (95.2%) had substantial improvement in hip
Biological fixation of cementless femoral implants requires primary
We assessed proprioception in the knee using the angle reproduction test in 20 healthy volunteers, ten patients with acute anterior instability and 20 patients with chronic anterior instability after reconstruction of the anterior cruciate ligament (ACL). In addition, the Lysholm-knee score, ligament laxity and patient satisfaction were determined. Acute trauma causes extensive damage to proprioception which is not restored by rehabilitation alone. Three months after operation, there remained a slight decrease in proprioception compared with the preoperative recordings, but six months after reconstruction, restoration of proprioception was seen near full extension and full flexion. In the mid-range position, proprioception was not restored. At follow-up, 3.7 ± 0.3 years after reconstruction, there was further improvement of proprioception in the mid-range position. There was no difference between open and arthroscopic techniques. The highest correlation was found between proprioception and patient satisfaction. After reconstruction of the ACL reduced proprioception may explain the poor functional outcome in some patients, despite restoration of mechanical