We performed a systematic review and meta-analysis
to compare the efficacy of intermittent mechanical compression combined
with pharmacological thromboprophylaxis, against either mechanical
compression or pharmacological prophylaxis in preventing deep-vein
thrombosis (DVT) and pulmonary embolism in patients undergoing hip
or knee replacement. A total of six randomised controlled trials,
evaluating a total of 1399 patients, were identified. In knee arthroplasty,
the rate of DVT was reduced from 18.7% with anticoagulation alone
to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03;
number needed to treat: seven). There was moderate, albeit non-significant,
heterogeneity (I2 = 42%). In hip replacement, there was
a non-significant reduction in DVT from 8.7% with mechanical compression
alone to 7.2% with additional pharmacological prophylaxis (RR 0.84)
and a significant reduction in DVT from 9.7% with anticoagulation
alone to 0.9% with additional mechanical compression (RR 0.17, p
<
0.001; number needed to treat: 12), with no heterogeneity (I2 =
0%). The included studies had insufficient power to demonstrate
an effect on pulmonary embolism. We conclude that the addition of intermittent mechanical leg
compression augments the efficacy of anticoagulation in preventing
DVT in patients undergoing both knee and hip replacement. Further
research on the role of combined modalities in thromboprophylaxis
in joint replacement and in other high-risk situations, such as fracture
of the hip, is warranted.
The purpose of this study was to investigate
whether a gender-specific high-flexion posterior-stabilised (PS)
total knee replacement (TKR) would offer advantages over a high-flex
PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain
and satisfaction, as well as during activity. A total of 24 female
patients with bilateral osteoarthritis entered this prospective,
blind randomised trial in which they received a high-flex PS TKR
in one knee and a gender-specific high-flexion PS TKR in the other
knee. At follow-up, patients were assessed clinically measuring
ROM, and questioned about pain, satisfaction and daily ‘feel’ of
each knee. Patients underwent gait analysis pre-operatively and
at one year, which yielded kinematic, kinetic and temporospatial
parameters indicative of knee function during gait. At final follow-up
we found no statistically significant differences in ROM (p = 0.82).
The median pain score was 0 (0 to 8) in both groups (p = 0.95).
The median satisfaction score was 9 (4 to 10) in the high-flex group
and 8 (0 to 10) in the gender-specific group (p = 0.98). The median
‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to
10) in the gender-specific group (p = 0.66). Gait analysis showed
no statistically significant differences between the two prosthetic
designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with
The June 2012 Knee Roundup360 looks at: ACI and mosaicplasty; ACI after microfracture; exercise therapy and the degenerate medial meniscal tear; intra-articular bupivacaine or ropivacaine at knee arthroscopy; lateral trochlear inclination and patellofemoral osteoarthritis; bone loss and ACL reconstruction; assessing stability using the contralateral knee; tranexamic acid and a useful review of knee replacement.
Dislocation of the shoulder may occur during
seizures in epileptics and other patients who have convulsions. Following
the initial injury, recurrent instability is common owing to a tendency
to develop large bony abnormalities of the humeral head and glenoid
and a susceptibility to further seizures. Assessment is difficult
and diagnosis may be missed, resulting in chronic locked dislocations
with protracted morbidity. Many patients have medical comorbidities,
and successful treatment requires a multidisciplinary approach addressing
the underlying seizure disorder in addition to the shoulder pathology.
The use of bony augmentation procedures may have improved the outcomes
after surgical intervention, but currently there is no evidence-based
consensus to guide treatment. This review outlines the epidemiology
and pathoanatomy of seizure-related instability, summarising the
currently-favoured options for treatment, and their results.
Peri-articular soft-tissue masses or ‘pseudotumours’
can occur after large-diameter metal-on-metal (MoM) resurfacing
of the hip and conventional total hip replacement (THR). Our aim
was to assess the incidence of pseudotumour formation and to identify
risk factors for their formation in a prospective cohort study. A total of 119 patients who underwent 120 MoM THRs with large-diameter
femoral heads between January 2005 and November 2007 were included
in the study. Outcome scores, serum metal ion levels, radiographs
and CT scans were obtained. Patients with symptoms or an identified
pseudotumour were offered MRI and an ultrasound-guided biopsy. There were 108 patients (109 hips) eligible for evaluation by
CT scan at a mean follow-up of 3.6 years (2.5 to 4.5); 42 patients
(39%) were diagnosed with a pseudotumour. The hips of 13 patients
(12%) were revised to a polyethylene acetabular component with small-diameter
metal head. Patients with elevated serum metal ion levels had a
four times increased risk of developing a pseudotumour. This study shows a substantially higher incidence of pseudotumour
formation and subsequent revisions in patients with MoM THRs than
previously reported. Because most revision cases were identified
only after an intensive screening protocol, we recommend close monitoring
of patients with MoM THR.
The open blast fracture of the pelvis is considered
to be the most severe injury within the spectrum of battlefield trauma.
We report our experience of 29 consecutive patients who had sustained
this injury in Afghanistan between 2008 and 2010. Their median new
injury severity score (NISS) was 41 (8 to 75), and mean blood requirement
in the first 24 hours was 60.3 units (0 to 224). In addition to
their orthopaedic injury, six had an associated vascular injury, seven
had a bowel injury, 11 had a genital injury and seven had a bladder
injury. In all, eight fractures were managed definitively with external
fixation and seven required internal fixation. Of those patients
who underwent internal fixation, four required removal of metalwork
for infection. Faecal diversion was performed in nine cases. The
median length of hospital stay following emergency repatriation
to the United Kingdom was 70.5 days (5 to 357) and the mean total
operating time was 29.6 hours (5 to 187). At a mean follow-up of
20.3 months (13.2 to 29.9), 24 patients (82.8%) were able to walk
and 26 (89.7%) had clinical and radiological evidence of stability
of the pelvic ring. As a result of the increase in terrorism, injuries that were
previously confined exclusively to warfare can now occur anywhere,
with civilian surgeons who are involved in trauma care potentially
required to manage similar injuries. Our study demonstrates that
the management of this injury pattern demands huge resources and significant
multidisciplinary input. Given the nature of the soft-tissue injury,
we would advocate external fixation as the preferred management
of these fractures. With the advent of emerging wound and faecal
management techniques, we do not believe that faecal diversion is
necessary in all cases.
The Bologna–Oxford (BOX) total ankle replacement
(TAR) was developed with the aim of achieving satisfactory pain-free
movement of the ankle. To date, only one single multicentre study
has reported its clinical results. The aim of this study was to
conduct an independent review of its mid-term results. We retrospectively reviewed a total of 60 prospectively followed
patients in whom 62 BOX TARs had been implanted between 2004 and
2008. We used the American Orthopedic Foot and Ankle Society (AOFAS)
score to assess the clinical results. Standardised radiographs taken
at the time of final follow-up were analysed by two observers. The
overall survival was 91.9% at a mean follow-up of 42.5 months (24
to 71). The mean AOFAS score had improved from 35.1 points (
Diabetes mellitus is recognised as a risk factor
for carpal tunnel syndrome. The response to treatment is unclear,
and may be poorer than in non-diabetic patients. Previous randomised
studies of interventions for carpal tunnel syndrome have specifically
excluded diabetic patients. The aim of this study was to investigate
the epidemiology of carpal tunnel syndrome in diabetic patients,
and compare the outcome of carpal tunnel decompression with non-diabetic
patients. The primary endpoint was improvement in the QuickDASH
score. The prevalence of diabetes mellitus was 11.3% (176 of 1564).
Diabetic patients were more likely to have severe neurophysiological
findings at presentation. Patients with diabetes had poorer QuickDASH
scores at one year post-operatively (p = 0.028), although the mean
difference was lower than the minimal clinically important difference
for this score. After controlling for underlying differences in
age and gender, there was no difference between groups in the magnitude of
improvement after decompression (p = 0.481). Patients with diabetes
mellitus can therefore be expected to enjoy a similar improvement
in function.
There have been few reports regarding the efficacy
of posterior instrumentation alone as surgical treatment for patients
with pyogenic spondylitis, thus avoiding the morbidity of anterior
surgery. We report the clinical outcomes of six patients with pyogenic
spondylitis treated effectively with a single-stage posterior fusion
without anterior debridement at a mean follow-up of 2.8 years (2
to 5). Haematological data, including white cell count and level
of C-reactive protein, returned to normal in all patients at a mean
of 8.2 weeks (7 to 9) after the posterior fusion. Rigid bony fusion
between the infected vertebrae was observed in five patients at
a mean of 6.3 months (4.5 to 8) post-operatively, with the remaining
patient having partial union. Severe back pain was immediately reduced
following surgery and the activities of daily living showed a marked
improvement. Methicillin-resistant Single-stage posterior fusion may be effective in patients with
pyogenic spondylitis who have relatively minor bony destruction.
Peri-tendinous injection of local anaesthetic,
both alone and in combination with corticosteroids, is commonly performed
in the treatment of tendinopathies. Previous studies have shown
that local anaesthetics and corticosteroids are chondrotoxic, but
their effect on tenocytes remains unknown. We compared the effects
of lidocaine and ropivacaine, alone or combined with dexamethasone,
on the viability of cultured bovine tenocytes. Tenocytes were exposed
to ten different conditions: 1) normal saline; 2) 1% lidocaine;
3) 2% lidocaine; 4) 0.2% ropivacaine; 5) 0.5% ropivacaine; 6) dexamethasone
(dex); 7) 1% lidocaine+dex; 8) 2% lidocaine+dex; 9) 0.2% ropivacaine+dex;
and 10) 0.5% ropivacaine+dex, for 30 minutes. After a 24-hour recovery
period, the viability of the tenocytes was quantified using the
CellTiter-Glo viability assay and fluorescence-activated cell sorting
(FACS) for live/dead cell counts. A 30-minute exposure to lidocaine
alone was significantly toxic to the tenocytes in a dose-dependent
manner, but a 30-minute exposure to ropivacaine or dexamethasone
alone was not significantly toxic. Dexamethasone potentiated ropivacaine tenocyte toxicity at higher
doses of ropivacaine, but did not potentiate lidocaine tenocyte
toxicity. As seen in other cell types, lidocaine has a dose-dependent
toxicity to tenocytes but ropivacaine is not significantly toxic.
Although dexamethasone alone is not toxic, its combination with
0.5% ropivacaine significantly increased its toxicity to tenocytes.
These findings might be relevant to clinical practice and warrant
further investigation.
The June 2012 Research Roundup360 looks at: platelet-rich plasma; ageing, bone and mesenchymal stem cells; cytokines and the herniated intervertebral disc; ulcerative colitis, Crohn’s disease and anti-inflammatories; the effect of NSAIDs on bone healing; osteoporosis of the fractured hip; herbal medicine and recovery after acute muscle injury; and ultrasound and the time to fracture union.
The June 2012 Spine Roundup360 looks at: back pain; spinal fusion for tuberculosis; anatomical course of the recurrent laryngeal nerve; groin pain with normal imaging; the herniated intervertebral disc; obesity’s effect on the spine; the medicolegal risks of cauda equina syndrome; and intravenous lidocaine use and failed back surgery syndrome.
The June 2012 Shoulder &
Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.
The June 2012 Oncology Roundup360 looks at: avoiding pelvic hemipelvectomy; proximal femoral metastasis; extendible prostheses; rotationplasty; soft-tissue sarcomas; osteosarcoma of the pelvis; recurrent chondrosarcoma ; MRI and the differentiation between benign and malignant lesions; and malignant fibrous histiocytoma.
The aetiology of hallux valgus is almost certainly multifactoral.
The biomechanics of the first ray is a common factor to most. There
is very little literature examining the anatomy of the proximal
metatarsal articular surface and its relationship to hallux valgus
deformity. We examined 42 feet from 23 specimens in this anatomical dissection
study.Introduction
Methods
When transferring tissue regenerative strategies
involving skeletal stem cells to human application, consideration needs
to be given to factors that may affect the function of the cells
that are transferred. Local anaesthetics are frequently used during
surgical procedures, either administered directly into the operative
site or infiltrated subcutaneously around the wound. The aim of
this study was to investigate the effects of commonly used local anaesthetics
on the morphology, function and survival of human adult skeletal
stem cells. Cells from three patients who were undergoing elective hip replacement
were harvested and incubated for two hours with 1% lidocaine, 0.5%
levobupivacaine or 0.5% bupivacaine hydrochloride solutions. Viability
was quantified using WST-1 and DNA assays. Viability and morphology
were further characterised using CellTracker Green/Ethidium Homodimer-1
immunocytochemistry and function was assessed by an alkaline phosphatase
assay. An additional group was cultured for a further seven days
to allow potential recovery of the cells after removal of the local
anaesthetic. A statistically significant and dose dependent reduction in cell
viability and number was observed in the cell cultures exposed to
all three local anaesthetics at concentrations of 25% and 50%, and
this was maintained even following culture for a further seven days. This study indicates that certain local anaesthetic agents in
widespread clinical use are deleterious to skeletal progenitor cells
when studied
The treatment of substantial proximal femoral
bone loss in young patients with developmental dysplasia of the
hip (DDH) is challenging. We retrospectively analysed the outcome
of 28 patients (30 hips) with DDH who underwent revision total hip
replacement (THR) in the presence of a deficient proximal femur,
which was reconstructed with an allograft prosthetic composite.
The mean follow-up was 15 years (8.5 to 25.5). The mean number of
previous THRs was three (1 to 8). The mean age at primary THR and
at the index reconstruction was 41 years (18 to 61) and 58.1 years
(32 to 72), respectively. The indication for revision included mechanical
loosening in 24 hips, infection in three and peri-prosthetic fracture
in three. Six patients required removal and replacement of the allograft
prosthetic composite, five for mechanical loosening and one for
infection. The survivorship at ten, 15 and 20 years was 93% (95%
confidence interval (CI) 91 to 100), 75.5% (95% CI 60 to 95) and
75.5% (95% CI 60 to 95), respectively, with 25, eight, and four
patients at risk, respectively. Additionally, two junctional nonunions
between the allograft and host femur required bone grafting and
plating. An allograft prosthetic composite affords a good long-term outcome
in the management of proximal femoral bone loss in revision THR
in patients with DDH, while preserving distal host bone.
We reviewed 101 patients with injuries of the
terminal branches of the infraclavicular brachial plexus sustained between
1997 and 2009. Four patterns of injury were identified: 1) anterior
glenohumeral dislocation (n = 55), in which the axillary and ulnar
nerves were most commonly injured, but the axillary nerve was ruptured
in only two patients (3.6%); 2) axillary nerve injury, with or without
injury to other nerves, in the absence of dislocation of the shoulder
(n = 20): these had a similar pattern of nerve involvement to those
with a known dislocation, but the axillary nerve was ruptured in
14 patients (70%); 3) displaced proximal humeral fracture (n = 15),
in which nerve injury resulted from medial displacement of the humeral
shaft: the fracture was surgically reduced in 13 patients; and 4) hyperextension
of the arm (n = 11): these were characterised by disruption of the
musculocutaneous nerve. There was variable involvement of the median
and radial nerves with the ulnar nerve being least affected. Surgical intervention is not needed in most cases of infraclavicular
injury associated with dislocation of the shoulder. Early exploration
of the nerves should be considered in patients with an axillary
nerve palsy without dislocation of the shoulder and for musculocutaneous
nerve palsy with median and/or radial nerve palsy. Urgent operation
is needed in cases of nerve injury resulting from fracture of the
humeral neck to relieve pressure on nerves.
This systematic review of the literature summarises
the clinical experience with ceramic-on-ceramic hip bearings over
the past 40 years and discusses the concerns that exist in relation
to the bearing combination. Loosening, fracture, liner chipping
on insertion, liner canting and dissociation, edge-loading and squeaking
have all been reported, and the relationship between these issues
and implant design and surgical technique is investigated. New design
concepts are introduced and analysed with respect to previous clinical
experience.
The June 2012 Children’s orthopaedics Roundup360 looks at; open reduction for DDH; growing rod instrumentation for scoliosis; acute patellar dislocation; management of the relapsed clubfoot; clubfoot in Iran; laughing gas and fracture manipulation; vascularised periosteal fibular grafting for nonunion; slipped upper femoral epiphysis; intramedullary leg lengthening and orthopaedic imaging and defensive medicine.
We present our early experience of arthroscopic
reduction of the dislocated hip in very young infants with developmental
dysplasia of the hip (DDH). Eight dislocated hips, which had failed attempts at closed reduction,
were treated by arthroscopy of the hip in five children with a mean
age of 5.8 months (4 to 7). A two-portal technique was used, with
a medial sub-adductor portal for a 2.7 mm cannulated system with
a 70° arthroscope and an anterolateral portal for the instruments. Following
evaluation of the key intra-articular structures, the hypertrophic
ligamentum teres and acetabular pulvinar were resected, and a limited
release of the capsule was performed prior to reduction of the hip.
All hips were reduced by a single arthroscopic procedure, the reduction
being confirmed on MRI scan. None of the hips had an inverted labrum.
The greatest obstacle to reduction was a constriction of the capsule.
At a mean follow-up of 13.2 months (9 to 24), all eight hips remained
stable. Three developed avascular necrosis. The mean acetabular index
decreased from 35.5° (30° to 40°) pre-operatively to 23.3° (17°
to 28°). This study demonstrates that arthroscopic reduction is feasible
using two standardised portals. Longer follow-up studies are necessary
to evaluate the functional results.
The June 2012 Foot &
Ankle Roundup360 looks at: the Achilles tendon Total Rupture Score (ATRS); endoscopic treatment of Haglund’s syndrome; whether it is worth removing metalwork; hyaluronic acid injection; thromboembolic events after fracture fixation in the ankle; whether surgeons are as good as CT scans for OCD of the talus; proximal fractures of the fifth metatarsal; nerve blocks for hallux valgus surgery; chronic osteomyelitis in the non-diabetic patient; Charcot arthropathy.
We compared the clinical and radiological outcomes
of two cementless femoral stems in the treatment of patients with
a Garden III or IV fracture of the femoral neck. A total of 70 patients At final follow-up there were no statistically significant differences
between the short anatomical and the conventional stems with regard
to the mean Harris hip score (85.7 (66 to 100) Our study demonstrated that despite the poor bone quality in
these elderly patients with a fracture of the femoral neck, osseo-integration
was obtained in all hips in both groups. However, the incidence
of thigh pain, pulmonary microemboli and peri-prosthetic fracture
was significantly higher in the conventional stem group than in
the short stem group.
An experimental rabbit model was used to test the null hypothesis,
that there is no difference in new bone formation around uncoated
titanium discs compared with coated titanium discs when implanted
into the muscles of rabbits. A total of three titanium discs with different surface and coating
(1, porous coating; 2, porous coating + Bonemaster (Biomet); and
3, porous coating + plasma-sprayed hydroxyapatite) were implanted
in 12 female rabbits. Six animals were killed after six weeks and
the remaining six were killed after 12 weeks. The implants with
surrounding tissues were embedded in methyl methacrylate and grinded
sections were stained with Masson-Goldners trichrome and examined
by light microscopy of coded sections.Objectives
Methods
We aimed to further evaluate the biomechanical characteristics
of two locking screws Synthetic tubular bone models representing normal bone density
and osteoporotic bone density were used. Artificial fracture gaps
of 1 cm were created in each specimen before fixation with one of
two constructs: 1) two locking screws using a five-hole locking
compression plate (LCP) plate; or 2) three non-locking screws with
a seven-hole LCP plate across each side of the fracture gap. The
stiffness, maximum displacement, mode of failure and number of cycles
to failure were recorded under progressive cyclic torsional and
eccentric axial loading.Objectives
Methods
We retrospectively reviewed 101 consecutive patients
with 114 femoral tumours treated by massive bone allograft at our
institution between 1986 and 2005. There were 49 females and 52
males with a mean age of 20 years (4 to 74). At a median follow-up
of 9.3 years (2 to 19.8), 36 reconstructions (31.5%) had failed.
The allograft itself failed in 27 reconstructions (24%). Mechanical complications such as delayed union, fracture and
failure of fixation were studied. The most adverse factor on the
outcome was the use of intramedullary nails, followed by post-operative
chemotherapy, resection length >
17 cm and age >
18 years at the
time of intervention. The simultaneous use of a vascularised fibular
graft to protect the allograft from mechanical complications improved
the outcome, but the use of intramedullary cementing was not as
successful. In order to improve the strength of the reconstruction and to
advance the biology of host–graft integration, we suggest avoiding
the use of intramedullary nails and titanium plates, but instead
using stainless steel plates, as these gave better results. The
use of a supplementary vascularised fibular graft should be strongly
considered in adult patients with resection >
17 cm and in those
who require post-operative chemotherapy.
We investigated the extent to which improved
balance relative to pain relief correlates with the success of total knee
replacement (TKR). A total of 81 patients were recruited to the
study: 16 men (19.8%) and 65 women (80.2%). Of these, 62 patients
(10 men, 52 women) with a mean age of 73 (57 to 83) underwent static
and dynamic assessment of balance pre-operatively and one year post-operatively.
The parameters of balance were quantified using commercially available
and validated equipment. Motor function and self-reported outcome
were also assessed. There was a significant improvement in dynamic balance (p <
0.001) one year after TKR, and better balance correlated with improved
mobility, functional balance and increased health-related quality
of life. As it seems that balance, and not only pain relief, influences
the success of TKR, balance skills should be better addressed during
the post-operative rehabilitation of patients who undergo TKR.
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
The optimal timing of percutaneous vertebroplasty
as treatment for painful osteoporotic vertebral compression fractures
(OVCFs) is still unclear. With the position of vertebroplasty having
been challenged by recent placebo-controlled studies, appropriate
timing gains importance. We investigated the relationship between the onset of symptoms
– the time from fracture – and the efficacy of vertebroplasty in
115 patients with 216 painful subacute or chronic OVCFs (mean time
from fracture 6.0 months ( It was found that there was an immediate and sustainable improvement
in the level of back pain and HRQoL after vertebroplasty, which
was independent of the time from fracture. Greater time from fracture
was associated with neither worse pre-operative conditions nor increased
vertebral deformity, nor with the presence of an intravertebral cleft. We conclude that vertebroplasty can be safely undertaken at an
appropriate moment between two and 12 months following the onset
of symptoms of an OVCF.
The June 2012 Hip &
Pelvis Roundup360 looks at: whether metal-on-metal is really such a disaster; resurfacings with unexplained pain; large heads and high ion levels; hip arthroscopy for FAI; the inaccuracy of clinical tests for impingement; arthroscopic lengthening of iliopsoas; the OA hip; the injured hamstring – football’s most common injury; an algorithm for hip fracture surgery; and sparing piriformis at THR.
Amputation was once widely practised for primary bone tumours of the limbs. Yet this situation has changed with limb salvage surgery becoming increasingly popular in the last 30 years. Many different techniques are now available. These include allografts, autografts, endoprostheses and allograft-prosthesis composites. This article reviews these methods, concentrating on the functional outcomes and complications that have been reported.
The June 2012 Wrist &
Hand Roundup360 looks at; radial osteotomy and advanced Kienböck's disease; fixing the Bennett fracture; PEEK plates and four-corner arthrodesis,;carpal tunnel release and haemodialysis; degloved digits and the reverse radial forearm flap; occupational hand injuries; trapeziometacarpal osteoarthritis; fixing the fractured metacarpal neck and pyrocarbon implants for the destroyed PIPJ.
The June 2012 Trauma Roundup360 looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas.
In a global environment of rising costs and limited funds, robotic and computer-assisted orthopaedic technologies could provide the means to drive a necessary revolution in arthroplasty productivity. Robots have been used to operate on humans for 20 years, but the adoption of the technology has lagged behind that of the manufacturing industry. The use of robots in surgery should enable cost savings by reducing instrumentation and inventories, and improving accuracy. Despite these benefits, the orthopaedic community has been resistant to change. If the ergonomics and economics are right, robotic technology just might transform the provision of joint replacement.
Modern metal-on-metal hip resurfacing has been
widely performed in the United Kingdom for over a decade. However,
the literature reports conflicting views of the benefits: excellent
medium- to long-term results with some brands in specific subgroups,
but high failure rates and local soft-tissue reactions in others.
The National Joint Registry for England and Wales (NJR) has collected
data on all hip resurfacings performed since 2003. This retrospective
cohort study recorded survival time to revision from a resurfacing
procedure, exploring risk factors independently associated with
failure. All patients with a primary diagnosis of osteoarthritis
who underwent resurfacing between 2003 and 2010 were included in
the analyses. Cox’s proportional hazard models were used to analyse
the extent to which the risk of revision was related to patient,
surgeon and implant covariates. A total of 27 971 hip resurfacings were performed during the
study period, of which 1003 (3.59%) underwent revision surgery.
In the final adjusted model, we found that women were at greater
risk of revision than men (hazard ratio (HR) = 1.30, p = 0.007),
but the risk of revision was independent of age. Of the implant-specific
predictors, five brands had a significantly greater risk of revision
than the Birmingham Hip Resurfacing (BHR) (ASR: HR = 2.82, p <
0.001,
Conserve: HR = 2.03, p <
0.001, Cormet: HR = 1.43, p = 0.001,
Durom: HR = 1.67, p <
0.001, Recap: HR = 1.58, p = 0.007). Smaller
femoral head components were also significantly more likely to require
revision (≤ 44 mm: HR = 2.14, p <
0.001, 45 to 47 mm: HR = 1.48,
p = 0.001) than medium or large heads, as were operations performed
by low-volume surgeons (HR = 1.36, p <
0.001). Once these influences
had been removed, in 4873 male patients <
60 years old undergoing
resurfacing with a BHR, the five-year estimated risk of revision
was 1.59%. In summary, after adjustment for a range of covariates we found
that there were significant differences in the rate of failure between
brands and component sizes. Younger male patients had good five-year
implant survival when the BHR was used.
In this prospective study a total of 80 consecutive
Chinese patients with Crowe type I or II developmental dysplasia of
the hip were randomly assigned for hip resurfacing arthroplasty
(HRA) or total hip replacement (THR). Three patients assigned to HRA were converted to THR, and three
HRA patients and two THR patients were lost to follow-up. This left
a total of 34 patients (37 hips) who underwent HRA and 38 (39 hips)
who underwent THR. The mean follow-up was 59.4 months (52 to 70)
in the HRA group and 60.6 months (50 to 72) in the THR group. There was
no failure of the prosthesis in either group. Flexion of the hip
was significantly better after HRA, but there was no difference
in the mean post-operative Harris hip scores between the groups.
The mean size of the acetabular component in the HRA group was significantly
larger than in the THR group (49.5 mm vs 46.1 mm, p = 0.001). There was
no difference in the mean abduction angle of the acetabular component
between the two groups. Although the patients in this series had risk factors for failure
after HRA, such as low body weight, small femoral heads and dysplasia,
the clinical results of resurfacing in those with Crowe type I or
II hip dysplasia were satisfactory. Patients in the HRA group had
a better range of movement, although neck-cup impingement was observed.
However, more acetabular bone was sacrificed in HRA patients, and
it is unclear whether this will have an adverse effect in the long
term.
To investigate the differences of open reduction and internal
fixation (ORIF) of complex AO Type C distal radius fractures between
two different models of a single implant type. A total of 136 patients who received either a 2.4 mm (n = 61)
or 3.5 mm (n = 75) distal radius locking compression plate (LCP
DR) using a volar approach were followed over two years. The main
outcome measurements included motion, grip strength, pain, and the
scores of Gartland and Werley, the Short-Form 36 (SF-36) and the
Disabilities of the Arm, Shoulder, and Hand (DASH). Differences
between the treatment groups were evaluated using regression analysis
and the likelihood ratio test with significance based on the Bonferroni
corrected p-value of <
0.003.Objectives
Methods
The use of two implants to manage concomitant ipsilateral femoral
shaft and proximal femoral fractures has been indicated, but no
studies address the relationship of dynamic hip screw (DHS) side
plate screws and the intramedullary nail where failure might occur
after union. This study compares different implant configurations
in order to investigate bridging the gap between the distal DHS
and tip of the intramedullary nail. A total of 29 left synthetic femora were tested in three groups:
1) gapped short nail (GSN); 2) unicortical short nail (USN), differing
from GSN by the use of two unicortical bridging screws; and 3) bicortical
long nail (BLN), with two angled bicortical and one unicortical bridging
screws. With these findings, five matched-pairs of cadaveric femora
were tested in two groups: 1) unicortical long nail (ULN), with
a longer nail than USN and three bridging unicortical screws; and
2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally
rotated 90°/sec until failure.Objectives
Methods
The aim of this study was to examine the rates
and potential risk factors for 28-day re-admission following a fracture
of the hip at a high-volume tertiary care hospital. We retrospectively
reviewed 467 consecutive patients with a fracture of the hip treated
in the course of one year. Causes and risk factors for unplanned
28-day re-admissions were examined using univariate and multivariate
analysis, including the difference in one-year mortality. A total
of 55 patients (11.8%) were re-admitted within 28 days of discharge.
The most common causes were pneumonia in 15 patients (27.3%), dehydration
and renal dysfunction in ten (18.2%) and deteriorating mobility
in ten (18.2%). A moderate correlation was found between chest infection
during the initial admission and subsequent re-admission with pneumonia
(r = 0.44, p <
0.001). A significantly higher mortality rate
at one year was seen in the re-admission group (41.8% (23 of 55)
The outcome of an anatomical shoulder replacement
depends on an intact rotator cuff. In 1981 Grammont designed a novel
large-head reverse shoulder replacement for patients with cuff deficiency.
Such has been the success of this replacement that it has led to
a rapid expansion of the indications. We performed a systematic
review of the literature to evaluate the functional outcome of each
indication for the reverse shoulder replacement. Secondary outcome
measures of range of movement, pain scores and complication rates
are also presented.
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
The purpose of this prospective study was to
evaluate the long-term clinical and radiological outcomes of revision of
the femoral component of a total hip replacement using impaction
bone grafting. Femoral revision with an impacted allograft was performed
on 29 patients (31 hips). In all, 21 hips (68%) had grade III or
IV femoral defects according to the Endo-Klinik classification.
A total of 11 patients (12 hips) died before the ten-year follow-up
period. Of the remaining patients, 18 patients (19 hips) were followed
for 10 to 15 years; three further patients died during this time.
None of the 31 stems underwent further revision of their stem. However,
four stems showed extensive subsidence (>
15 mm). One of these patients
had a femoral fracture that required fixation. Three other patients
had a femoral fracture, two of which required fixation and the other
was treated conservatively. Patients with a femoral fracture and/or
severe subsidence had significantly more grade IV defects (six of
seven hips; p = 0.004). One patient needed a closed reduction for
dislocation. Impaction allografting in revision hip surgery gives good long-term
results for femora with grades I, II and III Endo-Klinik-classified
defects. Extensive subsidence and femoral fractures were seen mainly
in patients with grade IV damaged femora.
We conducted a prospective follow-up MRI study
of originally asymptomatic healthy subjects to clarify the development
of Modic changes in the cervical spine over a ten-year period and
to identify related factors. Previously, 497 asymptomatic healthy
volunteers with no history of cervical trauma or surgery underwent
MRI. Of these, 223 underwent a second MRI at a mean follow-up of
11.6 years (10 to 12.7). These 223 subjects comprised 133 men and 100
women with a mean age at second MRI of 50.5 years (23 to 83). Modic
changes were classified as not present and types 1 to 3. Changes
in Modic types over time and relationships between Modic changes
and progression of degeneration of the disc or clinical symptoms
were evaluated. A total of 31 subjects (13.9%) showed Modic changes at
follow-up: type 1 in nine, type 2 in 18, type 3 in two, and types In the cervical spine over a ten-year period
The ideal form of fixation for displaced, extra-articular
fractures of the distal tibia remains controversial. In the UK, open
reduction and internal fixation with locking-plates and intramedullary
nailing are the two most common forms of treatment. Both techniques
provide reliable fixation but both are associated with specific
complications. There is little information regarding the functional
recovery following either procedure. We performed a randomised pilot trial to determine the functional
outcome of 24 adult patients treated with either a locking-plate
(n = 12) or an intramedullary nailing (n = 12). At six months, there
was an adjusted difference of 13 points in the Disability Rating
Index in favour of the intramedullary nail. However, this was not
statistically significant in this pilot trial (p = 0.498). A total
of seven patients required further surgery in the locking-plate
group and one in the intramedullary nail group. This study suggests that there may be clinically relevant, functional
differences in patients treated with nail
We aimed to obtain anthropometric data on Korean
knees and to compare these with data on commonly available total
knee arthroplasties (TKAs). The dimensions of the femora and tibiae
of 1168 knees were measured intra-operatively. The femoral components
were found to show a tendency toward mediolateral (ML) under-coverage
in small femurs and ML overhang in the large femurs. The ML under-coverage
was most prominent for the small prostheses. The ML/anteroposterior
(ML/AP) ratio of Korean tibiae was greater than that of tibial components. This study shows that, for different reasons, current TKAs do
not provide a reasonable fit for small or large Korean knees, and
that the ‘gender-specific’ and ‘stature-specific’ components help
for large Korean femurs but offer less satisfactory fits for small
femurs. Specific modifications of prostheses are needed for Asian
knees.
This study compared the outcome of total knee
replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses
during the first post-operative year and at five years’ follow-up,
using gait parameters as a new objective measure. This double-blind
randomised controlled clinical trial included 55 patients with mobile-bearing (n
= 26) and fixed-bearing (n = 29) prostheses of the same design,
evaluated pre-operatively and post-operatively at six weeks, three
months, six months, one year and five years. Each participant undertook
two walking trials of 30 m and completed the EuroQol questionnaire,
Western Ontario and McMaster Universities osteoarthritis index,
Knee Society score, and visual analogue scales for pain and stiffness.
Gait analysis was performed using five miniature angular rate sensors
mounted on the trunk (sacrum), each thigh and calf. The study population
was divided into two groups according to age (≤ 70 years Improvements in most gait parameters at five years’ follow-up
were greater for fixed-bearing TKRs in older patients (>
70 years),
and greater for mobile-bearing TKRs in younger patients (≤ 70 years).
These findings should be confirmed by an extended age controlled
study, as the ideal choice of prosthesis might depend on the age
of the patient at the time of surgery.
Revision arthroplasty of the hip is expensive
owing to the increased cost of pre-operative investigations, surgical implants
and instrumentation, protracted hospital stay and drugs. We compared
the costs of performing this surgery for aseptic loosening, dislocation,
deep infection and peri-prosthetic fracture. Clinical, demographic
and economic data were obtained for 305 consecutive revision total
hip replacements in 286 patients performed at a tertiary referral
centre between 1999 and 2008. The mean total costs for revision
surgery in aseptic cases (n = 194) were £11 897 (
To study the vascularity and bone metabolism of the femoral head/neck
following hip resurfacing arthroplasty, and to use these results
to compare the posterior and the trochanteric-flip approaches. In our previous work, we reported changes to intra-operative
blood flow during hip resurfacing arthroplasty comparing two surgical
approaches. In this study, we report the vascularity and the metabolic
bone function in the proximal femur in these same patients at one
year after the surgery. Vascularity and bone function was assessed
using scintigraphic techniques. Of the 13 patients who agreed to
take part, eight had their arthroplasty through a posterior approach
and five through a trochanteric-flip approach.Objectives
Methods
To assess the sensitivity and specificity of self-reported osteoporosis
compared with dual energy X-ray absorptiometry (DXA) defined osteoporosis,
and to describe medication use among participants with the condition. Data were obtained from a population-based longitudinal study
and assessed for the prevalence of osteoporosis, falls, fractures
and medication use. DXA scans were also undertaken.Objectives
Methods
A delay in the diagnosis of paediatric acute
and subacute haematogenous osteomyelitis can lead to potentially devastating
morbidity. There are no definitive guidelines for diagnosis, and
recommendations in the literature are generally based on expert
opinions, case series and cohort studies. All articles in the English literature on paediatric osteomyelitis
were searched using MEDLINE, CINAHL, EMBASE, Google Scholar, the
Cochrane Library and reference lists. A total of 1854 papers were
identified, 132 of which were examined in detail. All aspects of
osteomyelitis were investigated in order to formulate recommendations. On admission 40% of children are afebrile. The tibia and femur
are the most commonly affected long bones. Clinical examination,
blood and radiological tests are only reliable for diagnosis in
combination. Most studies were retrospective and there is a need for large,
multicentre, randomised, controlled trials to define protocols for
diagnosis and treatment. Meanwhile, evidence-based algorithms are
suggested for accurate and early diagnosis and effective treatment.
We retrospectively reviewed the records of 1150
computer-assisted total knee replacements and analysed the clinical
and radiological outcomes of 45 knees that had arthritis with a
pre-operative recurvatum deformity. The mean pre-operative hyperextension
deformity of 11° (6° to 15°), as measured by navigation at the start
of the operation, improved to a mean flexion deformity of 3.1° (0°
to 7°) post-operatively. A total of 41 knees (91%) were managed
using inserts ≤ 12.5 mm thick, and none had mediolateral laxity
>
2 mm from a mechanical axis of 0° at the end of the surgery. At
a mean follow-up of 26.4 months (13 to 48) there was significant
improvement in the mean Knee Society, Oxford knee and Western Ontario
and McMaster Universities Osteoarthritis Index scores compared with
the pre-operative values. The mean knee flexion improved from 105°
(80° to 125°) pre-operatively to 131° (120° to 145°), and none of
the limbs had recurrent recurvatum. These early results show that total knee replacement using computer
navigation and an algorithmic approach for arthritic knees with
a recurvatum deformity can give excellent radiological and functional
outcomes without recurrent deformity.
Elastic stable intramedullary nailing (ESIN)
is generally acknowledged to be the treatment of choice for displaced diaphyseal
femoral fractures in children over the age of three years, although
complication rates of up to 50% are described. Pre-bending the nails
is recommended, but there are no published data to support this.
Using synthetic bones and a standardised simulated fracture, we
performed biomechanical testing to determine the influence on the
stability of the fracture of pre-bending the nails before implantation.
Standard ESIN was performed on 24 synthetic femoral models with
a spiral fracture. In eight cases the nails were inserted without
any pre-bending, in a further eight cases they were pre-bent to
30° and in the last group of eight cases they were pre-bent to 60°. Mechanical
testing revealed that pre-bending to 60° produced a significant
increase in the stiffness or stability of the fracture. Pre-bending
to 60° showed a significant positive influence on the stiffness
compared with unbent nails. Pre-bending to 30° improved stiffness
only slightly. These findings validate the recommendations for pre-bending,
but the degree of pre-bend should exceed 30°. Adopting higher degrees
of pre-bending should improve stability in spiral fractures and
reduce the complications of varus deformity and shortening.
We present our experience with a double-mobility
acetabular component in 155 consecutive revision total hip replacements
in 149 patients undertaken between 2005 and 2009, with particular
emphasis on the incidence of further dislocation. The mean age of
the patients was 77 years (42 to 89) with 59 males and 90 females.
In all, five patients died and seven were lost to follow-up. Indications
for revision were aseptic loosening in 113 hips, recurrent instability
in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean
follow-up was 42 months (18 to 68). Three hips (2%) in three patients
dislocated within six weeks of surgery; one of these dislocated
again after one year. All three were managed successfully with closed
reduction. Two of the three dislocations occurred in patients who
had undergone revision for recurrent dislocation. All three were
found at revision to have abductor deficiency. There were no dislocations
in those revised for either aseptic loosening or sepsis. These results demonstrate a good mid-term outcome for this component.
In the 29 patients revised for instability, only two had a further
dislocation, both of which were managed by closed reduction.
The aim of this study was to determine the accuracy
of registration and the precision of the resection volume in navigated
hip arthroscopy for cam-type femoroacetabular impingement, using
imageless and image-based registration. A virtual cam lesion was
defined in 12 paired cadaver hips and randomly assigned to either
imageless or image-based (three-dimensional (3D) fluoroscopy) navigated
arthroscopic head–neck osteochondroplasty. The accuracy of patient–image
registration for both protocols was evaluated and post-operative
imaging was performed to evaluate the accuracy of the surgical resection.
We found that the estimated accuracy of imageless registration in the
arthroscopic setting was poor, with a mean error of 5.6 mm (standard
deviation ( In conclusion, given the limited femoral surface that can be
reached and digitised during arthroscopy of the hip, imageless registration
is inaccurate and does not allow for reliable surgical navigation.
However, image-based registration does acceptably allow for guided
femoral osteochondroplasty in the arthroscopic management of femoroacetabular
impingement.
We reviewed 31 consecutive patients with Friedreich’s
ataxia and scoliosis. There were 24 males and seven females with
a mean age at presentation of 15.5 years (8.6 to 30.8) and a mean
curve of 51° (13° to 140°). A total of 12 patients had thoracic
curvatures, 11 had thoracolumbar and eight had double thoracic/lumbar.
Two patients had long thoracolumbar collapsing scoliosis with pelvic
obliquity and four had hyperkyphosis. Left-sided thoracic curves in
nine patients (45%) and increased thoracic kyphosis differentiated
these deformities from adolescent idiopathic scoliosis. There were
17 patients who underwent a posterior instrumented spinal fusion
at mean age of 13.35 years, which achieved and maintained good correction
of the deformity. Post-operative complications included one death due
to cardiorespiratory failure, one revision to address nonunion and
four patients with proximal junctional kyphosis who did not need
extension of the fusion. There were no neurological complications
and no wound infections. The rate of progression of the scoliosis
in children kept under simple observation and those treated with bracing
was less for lumbar curves during bracing and similar for thoracic
curves. The scoliosis progressed in seven of nine children initially
treated with a brace who later required surgery. Two patients presented
after skeletal maturity with balanced curves not requiring correction.
Three patients with severe deformities who would benefit from corrective
surgery had significant cardiac co-morbidities.
Cadaveric models of the shoulder evaluate discrete motion segments
using the glenohumeral joint in isolation over a defined trajectory.
The aim of this study was to design, manufacture and validate a
robotic system to accurately create three-dimensional movement of
the upper body and capture it using high-speed motion cameras. In particular, we intended to use the robotic system to simulate
the normal throwing motion in an intact cadaver. The robotic system
consists of a lower frame (to move the torso) and an upper frame
(to move an arm) using seven actuators. The actuators accurately
reproduced planned trajectories. The marker setup used for motion
capture was able to determine the six degrees of freedom of all
involved joints during the planned motion of the end effector.Objectives
Methods
The outcome of 56 children (61 shoulders) treated
surgically at the Rizzoli Institute between April 1975 and June 2010
for congenital elevation of the scapula is reported. There were
31 girls and 25 boys with a mean age at surgery of 6.4 years (2
to 15). The deformity involved the right shoulder in 20 cases, the
left in 31 and was bilateral in five. The degree of the deformity
was graded clinically and radiologically according to the classifications
of Cavendish and Rigault, respectively. All patients underwent a
modified Green procedure combined, in selected cases, with resection
of the superomedial portion of the scapula and excision of any omovertebral
connection. After a mean follow-up of 10.9 years (1 to 29.3), there
was cosmetic improvement by at least one Cavendish grade in 54 shoulders (88.5%).
The mean abduction of the shoulder improved from 92° (50° to 155°)
to 112° (90° to 170°) and the mean flexion improved from 121° (80°
to 160°) to 155° (120° to 175°). The unsatisfactory cosmetic result
in seven shoulders was due to coexistent scoliosis in two cases
and insufficient reduction of the scapular elevation in the other
five. An incomplete upper brachial plexus palsy occurred post-operatively
in three patients but resolved within seven months. We suggest that a modified Green procedure combined with resection
of the superomedial portion of the scapula provides good cosmetic
and functional results in patients with Sprengel’s shoulder.
The FRCS (Tr &
Orth) examination has three components: MCQs, Vivas and Clinical Examination. The Vivas are further divided into four sections comprising Basic Science, Adult Pathology, Hands and Children’s Orthopaedics and Trauma. The Clinical Examination section is divided into Upper and Lower limb cases. The aim of this section in the Journal is to focus specifically on the trainees preparing for the exam and to cater to all the sections of the exam. The vision is to complete the cycle of all relevant exam topics (as per the syllabus) in four years.
Incomplete avulsion of the proximal hamstrings
can be a severely debilitating injury that causes weakness, pain
while sitting and inability to run. The results of the surgical treatment
of 23 consecutive patients with such injuries at least two years
after surgery are described. The surgery consisted of the repair
of the hamstrings directly onto the ischial tuberosity. At review,
using a visual analogue scale (VAS, 0 to 100), pain while sitting improved
from a mean of 40 (0 to 100) to 64 (0 to 100) (p = 0.024), weakness
from a mean of 39 (0 to 90) to 76 (7 to 100) (p = 0.0001) and the
ability to run from a mean of 24 (0 to 88) to 64 (0 to 95) (p =
0.0001). According to a VAS, satisfaction was rated at a mean of
81 (0 to 100) and 20 patients (87%) would have the same procedure
again. Hamstring strength measured pre- and post-operatively had
improved significantly from a mean of 64% (0% to 95%) to 88% (50%
to 114%) compared with the normal side. Most of these patients with symptomatic incomplete hamstring
avulsions unresponsive to conservative treatment had an improved
outcome after surgical repair.
We retrospectively reviewed 30 two-stage revision
procedures in 28 patients performed for fungal peri-prosthetic joint
infection (PJI) after a primary total knee replacement. Patients were
followed for at least two years or until the infection recurred.
The mean follow-up for patients who remained free of infection was
4.3 years (2.3 to 6.1). Overall, 17 patients were assessed as American
Society of Anesthesiologists grade 3 or 4. The surgical protocol included
removal of the infected implant, vigorous debridement and insertion
of an articulating cement spacer. This was followed by at least
six weeks of antimicrobial treatment and delayed reimplantation
in all patients. The mean interval between removal of the prosthesis
and reimplantation was 9.5 weeks (6 to 24). After reimplantation,
patients took antifungal agents orally for a maximum of six months. Fungal PJIs can be treated successfully by removal of all infected
material, appropriate antimicrobial treatment and delayed reimplantation.
In the majority of patients with slipped upper
femoral epiphysis only one hip is involved at primary diagnosis. However,
the contralateral hip often becomes involved over time. There are
no reliable factors predicting a contralateral slip. Whether or
not the contralateral hip should undergo prophylactic fixation is
a matter of controversy. We present a number of essential points
that have to be considered both when choosing to fix the contralateral
hip prophylactically as well as when refraining from surgery and
instead following the patients with repeat radiographs.
The purpose of this study was to report the outcome
of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with
anatomical endoscopic reconstruction using hamstring tendon autograft
at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive
men and 100 consecutive women with ‘isolated’ ACL rupture underwent
four-strand hamstring tendon reconstruction with anteromedial portal
femoral tunnel drilling and interference screw fixation by a single
surgeon. Details were recorded pre-operatively and at one, two,
seven and 15 years post-operatively. Outcomes included clinical
examination, subjective and objective scoring systems, and radiological
assessment. At 15 years only eight of 118 patients (7%) had moderate
or severe osteo-arthritic changes (International Knee Documentation
Committee Grades C and D), and 79 of 152 patients (52%) still performed
very strenuous activities. Overall graft survival at 15 years was
83% (1.1% failure per year). Patients aged <
18 years at the
time of surgery and patients with >
2 mm of laxity at one year had
a threefold increase in the risk of suffering a rupture of the graft
(p = 0.002 and p = 0.001, respectively). There was no increase in
laxity of the graft over time. ACL reconstructive surgery in patients with an ‘isolated’ rupture
using this technique shows good results 15 years post-operatively
with respect to ligamentous stability, objective and subjective
outcomes, and does not appear to cause osteoarthritis.
We describe the results of 81 consecutive revision
total hip replacements with impaction grafting in 79 patients using
a collared polished chrome–cobalt stem, customised in length according
to the extent of distal bone loss. Our hypothesis was that the features
of this stem would reduce the rate of femoral fracture and subsidence
of the stem. The mean follow-up was 12 years (8 to 15). No intra-operative
fracture or significant subsidence occurred. Only one patient suffered
a post-operative diaphyseal fracture, which was associated with
a fall. All but one femur showed incorporation of the graft. No
revision for aseptic loosening was recorded. The rate of survival of the femoral component at 12 years, using
further femoral revision as the endpoint, was 100% (95% confidence
interval (CI) 95.9 to 100), and at nine years using re-operation
for any reason as the endpoint, was 94.6% (95% CI 92.0 to 97.2). These results suggest that a customised cemented polished stem
individually adapted to the extent of bone loss and with a collar
may reduce subsidence and the rate of fracture while maintaining
the durability of the fixation.
Controversy continues to surround the management
of patients with an open fracture of the lower limb and an associated
vascular injury (Gustilo type IIIC). This study reports our 15-year
experience with these fractures and their outcome in 18 patients
(15 male and three female). Their mean age was 30.7 years (8 to
54) and mean Mangled Extremity Severity Score (MESS) at presentation
was 6.9 (3 to 10). A total of 15 lower limbs were salvaged and three underwent
amputation (two immediate and one delayed). Four patients underwent
stabilisation of the fracture by external fixation and 12 with an
internal device. A total of 11 patients had damage to multiple arteries
and eight had a vein graft. Wound cover was achieved with a pedicled
flap in three and a free flap in six. Seven patients developed a
wound infection and four developed nonunion requiring further surgery.
At a mean follow-up of five years (4.1 to 6.6) the mean visual analogue
scale for pain was 64 (10 to 90). Depression and anxiety were common.
Activities were limited mainly because of pain, and the MESS was
a valid predictor of the functional outcome. Distal tibial fractures
had an increased rate of nonunion when associated with posterior
tibial artery damage, and seven patients (39%) were not able to
return to their previous occupation.
We describe a new surgical technique for the
treatment of lacerations of the extensor tendon in zone I, which involves
a tenodesis using a length of palmaris longus tendon one-quarter
of its width. After exposing the dorsal aspect of the distal interphalangeal
joint and harvesting the tendon, a 1.5 mm drill bit is passed through
the insertion of the extensor tendon into the distal phalanx where
it penetrates through the skin of the pulp of the digit. The palmaris
longus tendon is threaded through the drill hole from dorsal to
ventral and the ventral end is tied in a simple knot and trimmed.
The palmaris longus tendon is then sutured to the extensor tendon
close to its insertion, and also at the middle of the middle phalanx. The operation was undertaken on 67 patients: 27 with an acute
injury and 40 patients with a chronic mallet deformity. One finger
(or the thumb) was involved in each patient. At a mean follow-up
of 12 months (6 to 18), 66 patients (98.5%) received excellent or
good results according to both the American Society for Surgery
of the Hand (ASSH) classification and Miller’s classification. Tenodesis using palmaris longus tendon after complete division
of an extensor tendon in zone 1 is a reliable form of treatment
for isolated acute or chronic ruptures.
We The triple-strand technique significantly increased the tensile
strength (p = 0.0001) and gap resistance (p = 0.01) of bovine tendon
repairs, and might have advantages in human application for accelerated
post-operative rehabilitation.
We aimed first to summarise minimal clinically important differences
(MCIDs) after total hip (THR) or knee replacement (TKR) in health-related
quality of life (HRQoL), measured using the Short-Form 36 (SF-36).
Secondly, we aimed to improve the precision of MCID estimates by
means of meta-analysis. We conducted a systematic review of English and non-English articles
using MEDLINE, the Cochrane Controlled Trials Register (1960–2011),
EMBASE (1991–2011), Web of Science, Academic Search Premier and
Science Direct. Bibliographies of included studies were searched
in order to find additional studies. Search terms included MCID
or minimal clinically important change, THR or TKR and Short-Form
36. We included longitudinal studies that estimated MCID of SF-36
after THR or TKR.Objectives
Methods
This prospective study compares the outcome of
157 hydroxyapatite (HA)-coated tibial components with 164 cemented
components in the ROCC Rotating Platform total knee replacement
in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There
were two revisions for loosening: one for an HA-coated and one for
a cemented tibial component. Radiological evaluation demonstrated
no radiolucent lines with the HA-coated femoral components. A total
of three HA-coated tibial components exhibited radiolucent lines
at three months post-operatively and these disappeared after three
further months of protected weight-bearing. With HA-coated components
the operating time was shorter (p <
0.006) and the radiological
assessment of the tibial interface was more stable (p <
0.01).
Using revision for aseptic loosening of the tibial component as
the end point, the survival rates at nine years was identical for
both groups at 99.1%. Our results suggest that HA-coated components perform at least
as well as the same design with cemented components and compare
favourably with those of series describing cemented or porous-coated
knee replacements, suggesting that fixation of both components with
hydroxyapatite is a reliable option in primary total knee replacement.
With the established success of the National
Joint Registry and the emergence of a range of new national initiatives for
the capture of electronic data in the National Health Service, orthopaedic
surgery in the United Kingdom has found itself thrust to the forefront
of an information revolution. In this review we consider the benefits
and threats that this revolution poses, and how orthopaedic surgeons
should marshal their resources to ensure that this is a force for
good.
There is no absolute method of evaluating healing
of a fracture of the tibial shaft. In this study we sought to validate a
new clinical method based on the systematic observation of gait,
first by assessing the degree of agreement between three independent
observers regarding the gait score for a given patient, and secondly
by determining how such a score might predict healing of a fracture. We used a method of evaluating gait to assess 33 patients (29
men and four women, with a mean age of 29 years (15 to 62)) who
had sustained an isolated fracture of the tibial shaft and had been
treated with a locked intramedullary nail. There were 15 closed
and 18 open fractures (three Gustilo and Anderson grade I, seven
grade II, seven grade IIIA and one grade IIIB). Assessment was carried
out three and six months post-operatively using videos taken with
a digital camera. Gait was graded on a scale ranging from 1 (extreme
difficulty) to 4 (normal gait). Bivariate analysis included analysis
of variance to determine whether the gait score statistically correlated
with previously validated and standardised scores of clinical status
and radiological evidence of union. An association was found between the pattern of gait and all
the other variables. Improvement in gait was associated with the
absence of pain on weight-bearing, reduced tenderness over the fracture,
a higher Radiographic Union Scale in Tibial Fractures score, and
improved functional status, measured using the Brazilian version
of the Short Musculoskeletal Function Assessment questionnaire (all
p <
0.001). Although further study is needed, the analysis of
gait in this way may prove to be a useful clinical tool.
The benefit of arthroscopy of the hip in the
treatment of femoroacetabular impingement (FAI) in terms of quality
of life (QoL) has not been reported. We prospectively collected
data on 612 patients (257 women (42%) and 355 men (58%)) with a
mean age at the time of surgery of 36.7 years (14 to 75) who underwent
arthroscopy of the hip for FAI under the care of a single surgeon.
The minimum follow-up was one year (mean 3.2 years (1 to 7)). The
responses to the modified Harris hip score were translated using
the Rosser Index Matrix in order to provide a QoL score. The mean
QoL score increased from 0.946 (-1.486 to 0.995) to 0.974 (0.7 to
1) at one year after surgery (p <
0.001). The mean QoL score
in men was significantly higher than in women, both before and one
year after surgery (both p <
0.001). However, the mean change
in the QoL score was not statistically different between men and
women (0.02 (-0.21 to 0.27) and 0.04 (-0.16 to 0.87), respectively;
p = 0.12). Linear regression analysis revealed that the significant predictors
of a change in QoL score were pre-operative QoL score (p <
0.001)
and gender (p = 0.04). The lower the pre-operative score, the higher
the gain in QoL post-operatively (ρ = -0.66; p <
0.001). One
year after surgery the QoL scores in the 612 patients had improved
in 469 (76.6%), remained unchanged in 88 (14.4%) and had deteriorated
in 55 (9.0%).
The painful subluxed or dislocated hip in adults
with cerebral palsy presents a challenging problem. Prosthetic dislocation
and heterotopic ossification are particular concerns. We present
the first reported series of 19 such patients (20 hips) treated
with hip resurfacing and proximal femoral osteotomy. The pre-operative
Gross Motor Function Classification System (GMFCS) was level V in
13 (68%) patients, level IV in three (16%), level III in one (5%) and
level II in two (11%). The mean age at operation was 37 years (13
to 57). The mean follow-up was 8.0 years (2.7 to 11.6), and 16 of the
18 (89%) contactable patients or their carers felt that the surgery
had been worthwhile. Pain was relieved in 16 of the 18 surviving
hips (89%) at the last follow-up, and the GMFCS level had improved
in seven (37%) patients. There were two (10%) early dislocations;
three hips (15%) required revision of femoral fixation, and two
hips (10%) required revision, for late traumatic fracture of the
femoral neck and extra-articular impingement, respectively. Hence
there were significant surgical complications in a total of seven
hips (35%). No hips required revision for instability, and there
were no cases of heterotopic ossification. We recommend hip resurfacing with proximal femoral osteotomy
for the treatment of the painful subluxed or dislocated hip in patients
with cerebral palsy.
Autologous chondrocyte implantation (ACI) and
mosaicplasty are methods of treating symptomatic articular cartilage
defects in the knee. This study represents the first long-term randomised
comparison of the two techniques in 100 patients at a minimum follow-up
of ten years. The mean age of the patients at the time of surgery was
31.3 years (16 to 49); the mean duration of symptoms pre-operatively
was 7.2 years (9 months to 20 years). The lesions were large with
the mean size for the ACI group being 440.9 mm2 (100
to 1050) and the mosaicplasty group being 399.6 mm2 (100
to 2000). Patients had a mean of 1.5 previous operations (0 to 4)
to the articular cartilage defect. Patients were assessed using
the modified Cincinnati knee score and the Stanmore-Bentley Functional Rating
system. The number of patients whose repair had failed at ten years
was ten of 58 (17%) in the ACI group and 23 of 42 (55%) in the mosaicplasty
group (p <
0.001). The functional outcome of those patients with a surviving graft
was significantly better in patients who underwent ACI compared
with mosaicplasty (p = 0.02).
The purpose of this study was to examine the effect of posterior
cruciate ligament (PCL) retention, PCL recession, and PCL excision
during cruciate-retaining total knee replacement. A total of 3018 anatomic graduated component total knee replacements
were examined; 1846 of these retained the PCL, 455 PCLs were partially
recessed, and in 717 the PCL was completely excised from the back
of the tibia.Objectives
Methods
We assessed the outcome of patients who were
lost to follow-up after arthroplasty by a single surgeon. The aim was
to validate the surgeon’s data set with the Australian Orthopaedic
Association National Joint Replacement Registry and determine the
outcome of those patients lost to follow-up. Prospective data on patient demographics, operative details and
outcomes of the surgeon’s 1192 primary unicompartmental knee arthroplasty
(UKA) procedures were analysed. There were 69 knees in patients
who were lost to follow-up, among whom the Registry identified 31
deaths and eight revisions. The cumulative percentage revision (CPR) at seven years using
the additional Registry data was 8.8% (95% confidence interval (CI)
7 to 11). Using the surgeon’s data, the CPR at seven years was 8%
(95% CI 6.3 to 10.1) for the best-case scenario where loss to follow-up
was excluded, and 16% (95% CI 13.8 to 19.4) for the worst-case scenario, where
all patients lost to follow-up were deemed to have been revised.
There was a significantly higher mortality rate in those patients
lost to follow-up. This study demonstrates that a national joint registry can be
used by individual surgeons to establish more accurate revision
rates in their arthroplasty patients. This is expected to facilitate
a more rigorous audit of surgical outcomes by surgeons and lead
to more accurate and uniform reporting of the results of arthroplasty
in general.
There have been many advances in the resuscitation
and early management of patients with severe injuries during the
last decade. These have come about as a result of the reorganisation
of civilian trauma services in countries such as Germany, Australia
and the United States, where the development of trauma systems has
allowed a concentration of expertise and research. The continuing
conflicts in the Middle East have also generated a significant increase
in expertise in the management of severe injuries, and soldiers
now survive injuries that would have been fatal in previous wars.
This military experience is being translated into civilian practice. The aim of this paper is to give orthopaedic surgeons a practical,
evidence-based guide to the current management of patients with
severe, multiple injuries. It must be emphasised that this depends
upon the expertise, experience and facilities available within the
local health-care system, and that the proposed guidelines will
inevitably have to be adapted to suit the local resources.
The April 2012 Oncology Roundup360 looks at chondrosarcoma of the cervical spine, if excision margins matter, radiation-induced sarcomas, giant cell tumours and bone cement, enchondromatosis and malignant change, axial or appendicular Ewing’s sarcoma, and diagnosing a sarcoma
The April 2012 Hip &
Pelvis Roundup360 looks at osteoporotic hip fractures, retrotrochanteric pain, fibrin adhesive and reattachment of articular cartilage, autologous bone marrow mononuclear cells and avascular necrosis, bearing surfaces, stability after THR, digital templating, pelvic tilt after THR, custom-made sockets for DDH, and dogs and THR
Pseudotumours (abnormal peri-prosthetic soft-tissue reactions)
following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have
been associated with elevated metal ion levels, suggesting that
excessive wear may occur due to edge-loading of these MoM implants.
This study aimed to quantify The duration and magnitude of edge-loading Objectives
Methods
Chris Lavy is an orthopaedic surgeon in Oxford (UK) who lived and worked in Malawi for ten years. There he helped build an orthopaedic hospital and research unit. He was also one of the founders of COSECSA, the regional college of surgeons for East and Central Africa in 1999.
The April 2012 Knee Roundup360 looks at the torn ACL, ACL reconstruction, the risk of ACL rupture, the benefit of warm-ups before exercise, glucosamine and tibiofemoral osteoarthritis, sensitisation and sporting tendinopathy, pain relief after TKR, the long-term results of the Genesis I, the gender specific recovery times after TKR, and the accuracy of the orthopaedic eyeball
Given the growing prevalence of obesity around
the world and its association with osteoarthritis of the knee, orthopaedic
surgeons need to be familiar with the management of the obese patient
with degenerative knee pain. The precise mechanism by which obesity
leads to osteoarthritis remains unknown, but is likely to be due
to a combination of mechanical, humoral and genetic factors. Weight loss has clear medical benefits for the obese patient
and seems to be a logical way of relieving joint pain associated
with degenerative arthritis. There are a variety of ways in which
this may be done including diet and exercise, and treatment with
drugs and bariatric surgery. Whether substantial weight loss can
delay or even reverse the symptoms associated with osteoarthritis
remains to be seen. Surgery for osteoarthritis in the obese patient can be technically
more challenging and carries a risk of additional complications.
Substantial weight loss before undertaking total knee replacement
is advisable. More prospective studies that evaluate the effect
of significant weight loss on the evolution of symptomatic osteoarthritis
of the knee are needed so that orthopaedic surgeons can treat this
patient group appropriately.
Professor Mario Mercuri passed away suddenly after a complication of cancer on 7th May 2011 after dedicating his entire life to patients with tumours.
An ongoing prospective study to investigate failing metal-on-metal
hip prostheses was commenced at our centre in 2008. We report on
the results of the analysis of the first consecutive 126 failed
mated total hip prostheses from a single manufacturer. Analysis was carried out using highly accurate coordinate measuring
to calculate volumetric and linear rates of the articular bearing
surfaces and also the surfaces of the taper junctions. The relationship
between taper wear rates and a number of variables, including bearing
diameter and orientation of the acetabular component, was investigated.Objectives
Methods
As part of the national initiative to reduce
waiting times for joint replacement surgery in Wales, the Cardiff
and Vale NHS Trust referred 224 patients to the NHS Treatment Centre
in Weston-Super-Mare for total knee replacement (TKR). A total of
258 Kinemax TKRs were performed between November 2004 and August
2006. Of these, a total of 199 patients (232 TKRs, 90%) have been
followed up for five years. This cohort was compared with 258 consecutive
TKRs in 250 patients, performed at Cardiff and Vale Orthopaedic
Centre (CAVOC) over a similar time period. The five year cumulative
survival rate was 80.6% (95% confidence interval (CI) 74.0 to 86.0)
in the Weston-Super-Mare cohort and 95.0% (95% CI 90.2 to 98.2)
in the CAVOC cohort with revision for any reason as the endpoint.
The relative risk for revision at Weston-Super-Mare compared with
CAVOC was 3.88 (p <
0.001). For implants surviving five years,
the mean Oxford knee scores (OKS) and mean EuroQol (EQ-5D) scores
were similar (OKS: Weston-Super-Mare 29 (2 to 47) The results show a higher revision rate for patients operated
at Weston-Super-Mare Treatment Centre, with a reduction in functional
outcome and quality of life after revision. This further confirms
that patients moved from one area to another for joint replacement
surgery fare poorly.
The ideal bearing surface for young patients
undergoing total hip replacement (THR) remains controversial. We report
the five-year results of a randomised controlled trial comparing
the clinical and radiological outcomes of 102 THRs in 91 patients
who were <
65 years of age. These patients were randomised to
receive a cobalt–chrome on ultra-high-molecular-weight polyethylene,
cobalt–chrome on highly cross-linked polyethylene, or a ceramic-on-ceramic
bearing. In all, 97 hip replacements in 87 patients were available
for review at five years. Two hips had been revised, one for infection
and one for peri-prosthetic fracture. At the final follow-up there were no significant differences
between the groups for the mean Western Ontario and McMaster Universities
osteoarthritis index (pain, p = 0.543; function, p = 0.10; stiffness,
p = 0.99), Short Form-12 (physical component, p = 0.878; mental
component, p = 0.818) or Harris hip scores (p = 0.22). Radiological
outcomes revealed no significant wear in the ceramic group. Comparison of standard and highly cross-linked polyethylene,
however, revealed an almost threefold difference in the mean annual
linear wear rates (0.151 mm/year
Matrix-induced autologous chondrocyte implantation
(MACI) is an established technique used to treat osteochondral lesions
in the knee. For larger osteochondral lesions (>
5 cm2)
deeper than approximately 8 mm we have combined the use of two MACI
membranes with impaction grafting of the subchondral bone. We report
our results of 14 patients who underwent the ‘bilayer collagen membrane’
technique (BCMT) with a mean follow-up of 5.2 years (2 to 8). There
were 12 men and two women with a mean age of 23.6 years (16 to 40).
The mean size of the defect was 7.2 cm2 (5.2 to 12 cm2)
and were located on the medial (ten) or lateral (four) femoral condyles.
The mean modified Cincinnati knee score improved from 45.1 (22 to
70) pre-operatively to 82.8 (34 to 98) at the most recent review
(p <
0.05). The visual analogue pain score improved from 7.3
(4 to 10) to 1.7 (0 to 6) (p <
0.05). Twelve patients were considered
to have a good or excellent clinical outcome. One graft failed at
six years. The BCMT resulted in excellent functional results and durable
repair of large and deep osteochondral lesions without a high incidence
of graft-related complications.
This study evaluated the effect of limb lengthening
on longitudinal growth in patients with achondroplasia. Growth of
the lower extremity was assessed retrospectively by serial radiographs
in 35 skeletally immature patients with achondroplasia who underwent
bilateral limb lengthening (Group 1), and in 12 skeletally immature
patients with achondroplasia who did not (Group 2). In Group 1,
23 patients underwent only tibial lengthening (Group 1a) and 12 patients
underwent tibial and femoral lengthening sequentially (Group 1b). The mean lengthening in the tibia was 9.2 cm (59.5%) in Group
1a, and 9.0 cm (58.2%) in the tibia and 10.2 cm (54.3%) in the femur
in Group 1b. The mean follow-up was 9.3 years (8.6 to 10.3). The
final mean total length of lower extremity in Group 1a was 526.6
mm (501.3 to 552.9) at the time of skeletal maturity and 610.1 mm
(577.6 to 638.6) in Group 1b, compared with 457.0 mm (411.7 to 502.3)
in Group 2. However, the mean actual length, representing the length
solely grown from the physis without the length of distraction,
showed that there was a significant disturbance of growth after
limb lengthening. In Group 1a, a mean decrease of 22.4 mm (21.3
to 23.1) (4.9%) was observed in the actual limb length when compared
with Group 2, and a greater mean decrease of 38.9 mm (37.2 to 40.8)
(8.5%) was observed in Group 1b when compared with Group 2 at skeletal
maturity. In Group 1, the mean actual limb length was 16.5 mm (15.8 to
17.2) (3.6%) shorter in Group 1b when compared with Group 1a at
the time of skeletal maturity. Premature physeal closure was seen
mostly in the proximal tibia and the distal femur with relative
preservation of proximal femur and distal tibia. We suggest that significant disturbance of growth can occur after
extensive limb lengthening in patients with achondroplasia, and
therefore, this should be included in pre-operative counselling
of these patients and their parents.
The outcomes of 261 nerve injuries in 100 patients
were graded good in 173 cases (66%), fair in 70 (26.8%) and poor in
18 (6.9%) at the final review (median 28.4 months (1.3 to 64.2)).
The initial grades for the 42 sutures and graft were 11 good, 14
fair and 17 poor. After subsequent revision repairs in seven, neurolyses
in 11 and free vascularised fasciocutaneous flaps in 11, the final
grades were 15 good, 18 fair and nine poor. Pain was relieved in
30 of 36 patients by nerve repair, revision of repair or neurolysis,
and flaps when indicated. The difference in outcome between penetrating
missile wounds and those caused by explosions was not statistically
significant; in the latter group the onset of recovery from focal
conduction block was delayed (mean 4.7 months (2.5 to 10.2)
We present the clinical results and survivorship
of consecutive 100 Birmingham Hip Resurfacings in 90 patients at
a minimum follow-up of ten years. All procedures were carried out
by an independent surgeon who commenced a prospective study in 1998.
Patients were assessed clinically using the Western Ontario and
McMaster Universities osteoarthritis index, Short-Form 36, Harris
hip score and University of California, Los Angeles activity score. Radiological
analysis was performed by an independent observer and blood metal
ion levels concentrations were measured at ten years post-operatively
in 62 patients. The median acetabular component inclination was
46.2° (34° to 59°) and anteversion 11.0° (0° to 30°). The median
chromium concentration in the unilateral group was 1.74 (0.41 to
15.23) and for the bilateral group was 2.98 (1.57 to 18.01). The
equivalent values for cobalt were 1.67 (0.54 to 20.4) and 1.88 (1.38
to 19.32). In total there were eight failures giving an overall survival
at ten years of 92% (95% confidence interval (CI) 86.7 to 97.3).
BHR in male patients had an improved survivorship of 94.6% (95%
CI 89.4 to 100) compared with females at 84.6% (95% CI 70.7 to 98.5),
but this did not reach statistical significance (p = 0.119). Four
of the nine BHRs with a bearing diameter of 42 mm failed. The overall results were consistent with data produced from other
centres in that the clinical outcome of large male patients was
extremely encouraging, whereas the survival of the smaller joints
was less satisfactory.