Advertisement for orthosearch.org.uk
Results 1181 - 1200 of 1769
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 75 - 80
1 Jan 2016
Merolla G Chin P Sasyniuk TM Paladini P Porcellini G

Aims

We evaluated clinical and radiographic outcomes of total shoulder arthroplasty (TSA) using the second-generation Trabecular Metal (TM) Glenoid component. The first generation component was withdrawn in 2005 after a series of failures were reported. Between 2009 and 2012, 40 consecutive patients with unilateral TSA using the second-generation component were enrolled in this clinical study. The mean age of the patients was 63.8 years (40 to 75) and the mean follow-up was 38 months (24 to 42).

Methods

Patients were evaluated using the Constant score (CS), the American Shoulder and Elbow Surgeons (ASES) score and routine radiographs.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 771 - 779
1 Jun 2015
te Stroet MAJ Rijnen WHC Gardeniers JWM van Kampen A Schreurs BW

We report the clinical and radiographic outcomes of 208 consecutive femoral revision arthroplasties performed in 202 patients (119 women, 83 men) between March 1991 and December 2007 using the X-change Femoral Revision System, fresh-frozen morcellised allograft and a cemented polished Exeter stem. All patients were followed prospectively. The mean age of the patients at revision was 65 years (30 to 86). At final review in December 2013 a total of 130 patients with 135 reconstructions (64.9%) were alive and had a non re-revised femoral component after a mean follow-up of 10.6 years (4.7 to 20.9). One patient was lost to follow-up at six years, and their data were included up to this point. Re-operation for any reason was performed in 33 hips (15.9%), in 13 of which the femoral component was re-revised (6.3%). The mean pre-operative Harris hip score was 52 (19 to 95) (n = 73) and improved to 80 (22 to 100) (n = 161) by the last follow-up. Kaplan–Meier survival with femoral re-revision for any reason as the endpoint was 94.9% (95% confidence intervals (CI) 90.2 to 97.4) at ten years; with femoral re-revision for aseptic loosening as the endpoint it was 99.4% (95% CI 95.7 to 99.9); with femoral re-operation for any reason as the endpoint it was 84.5% (95% CI 78.3 to 89.1); and with subsidence ≥ 5 mm it was 87.3% (95% CI 80.5 to 91.8). Femoral revision with the use of impaction allograft bone grafting and a cemented polished stem results in a satisfying survival rate at a mean of ten years’ follow-up.

Cite this article: Bone Joint J 2015; 97-B:771–9.


Bone & Joint Research
Vol. 3, Issue 8 | Pages 252 - 261
1 Aug 2014
Tilley JMR Murphy RJ Chaudhury S Czernuszka JT Carr AJ

Objectives

The effects of disease progression and common tendinopathy treatments on the tissue characteristics of human rotator cuff tendons have not previously been evaluated in detail owing to a lack of suitable sampling techniques. This study evaluated the structural characteristics of torn human supraspinatus tendons across the full disease spectrum, and the short-term effects of subacromial corticosteroid injections (SCIs) and subacromial decompression (SAD) surgery on these structural characteristics.

Methods

Samples were collected inter-operatively from supraspinatus tendons containing small, medium, large and massive full thickness tears (n = 33). Using a novel minimally invasive biopsy technique, paired samples were also collected from supraspinatus tendons containing partial thickness tears either before and seven weeks after subacromial SCI (n = 11), or before and seven weeks after SAD surgery (n = 14). Macroscopically normal subscapularis tendons of older patients (n = 5, mean age = 74.6 years) and supraspinatus tendons of younger patients (n = 16, mean age = 23.3) served as controls. Ultra- and micro-structural characteristics were assessed using atomic force microscopy and polarised light microscopy respectively.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 58 - 64
1 Jan 2016
Ahmed I Salmon LJ Waller A Watanabe H Roe JP Pinczewski LA

Aims

Oxidised zirconium was introduced as a material for femoral components in total knee arthroplasty (TKA) as an attempt to reduce polyethylene wear. However, the long-term survival of this component is not known.

Methods

We performed a retrospective review of a prospectively collected database to assess the ten year survival and clinical and radiological outcomes of an oxidised zirconium total knee arthroplasty with the Genesis II prosthesis.

The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and a patient satisfaction scale were used to assess outcome.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 39 - 40
1 Aug 2014
Das A

In a decidedly upper limb themed series of reviews this edition of Cochrane Corner summarises four new and updated reviews published by the Cochrane Bone, Joint and Muscle Trauma Group over the last few months. The tenacious reviewers at the Cochrane collaboration have turned their beady eyes to conservative treatments for shoulder dislocations and clavicle fractures along with evaluation of femoral nerve blocks in knee replacement and how to best manage entrapment injuries in children.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 27 - 29
1 Jun 2013

The June 2013 Shoulder & Elbow Roundup360 looks at: whether suture anchors are still the gold standard; infection and revision elbow arthroplasty; the variable success of elbow replacements; sliding knots; neurologic cuff pain and the suprascapular nerve; lies, damn lies and statistics; osteoarthritis; and one- or two-stage treatment for the infected shoulder revision.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 346 - 352
1 Mar 2015
Chadwick C Whitehouse SL Saxby TS

Flexor digitorum longus transfer and medial displacement calcaneal osteotomy is a well-recognised form of treatment for stage II posterior tibial tendon dysfunction. Although excellent short- and medium-term results have been reported, the long-term outcome is unknown. We reviewed the clinical outcome of 31 patients with a symptomatic flexible flat-foot deformity who underwent this procedure between 1994 and 1996. There were 21 women and ten men with a mean age of 54.3 years (42 to 70). The mean follow-up was 15.2 years (11.4 to 16.5). All scores improved significantly (p < 0.001). The mean American Orthopedic Foot and Ankle Society (AOFAS) score improved from 48.4 pre-operatively to 90.3 (54 to 100) at the final follow-up. The mean pain component improved from 12.3 to 35.2 (20 to 40). The mean function score improved from 35.2 to 45.6 (30 to 50). The mean visual analogue score for pain improved from 7.3 to 1.3 (0 to 6). The mean Short Form-36 physical component score was 40.6 (sd 8.9), and this showed a significant correlation with the mean AOFAS score (r = 0.68, p = 0.005). A total of 27 patients (87%) were pain free and functioning well at the final follow-up. We believe that flexor digitorum longus transfer and calcaneal osteotomy provides long-term pain relief and satisfactory function in the treatment of stage II posterior tibial tendon dysfunction.

Cite this article: Bone Joint J 2015;97-B:346–52.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results.

In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy).

The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection.

The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61.

On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching.

The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising.

Cite this article: Bone Joint J 2015;97-B:1662–7.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 17 - 19
1 Aug 2014

The August 2014 Foot & Ankle Roundup360 looks at: calcaneotibial nail in ankle fractures; reamer irrigator aspirator for ankle fusion; periprosthetic bone infection; infection in ankle fixation; cheap and cheerful OK in MTP fusion plates; sliding fibular graft for peroneal tendon pathology and fusion for failed ankle replacement.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 15 - 16
1 Oct 2015

The October 2015 Foot & Ankle Roundup360 looks at: TightRope in Weber C fractures; A second look at the TightRope; Incisional VAC comes of age?; Platelet-derived growth factor and ankle fusions; Achilles tendon rehab in the longer term following surgery; Telemedicine for diabetic foot ulcer


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1533 - 1538
1 Nov 2015
Zhang X Shao X Huang W Zhu H Yu Y

We report a new surgical technique for the treatment of traumatic dislocation of the carpometacarpal (CMC) joint of the thumb. This is a tenodesis which uses part of the flexor carpi radialis.

Between January 2010 and August 2013, 13 patients with traumatic instability of the CMC joint of the thumb were treated using this technique. The mean time interval between injury and ligament reconstruction was 13 days (0 to 42). The mean age of the patients at surgery was 38 years: all were male.

At a mean final follow-up of 26 months (24 to 29), no patient experienced any residual instability. The mean total palmar abduction of the CMC joint of the thumb was 61° and the mean radial abduction 65° The mean measurements for the uninjured hand were 66° (60° to 73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained a mean score of 85 (75 to 95), which included four excellent, seven good, and two fair results.

Our technique offers an alternative method of treating traumatic dislocation of the CMC joint of the thumb: it produces a stable joint and acceptable hand function.

Cite this article: Bone Joint J 2015;97-B:1533–8.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 2 - 8
1 Dec 2013
Jones R Wood D

This article provides an overview of the role of genomics in sarcomas and describes how new methods of analysis and comparative screening have provided the potential to progress understanding and treatment of sarcoma. This article reviews genomic techniques, the evolution of the use of genomics in cancer, the current state of genomic analysis, and also provides an overview of the medical, social and economic implications of recent genomic advances.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1525 - 1529
1 Nov 2014
Thangarajah T Alexander S Bayley I Lambert SM

We report our experience with glenohumeral arthrodesis as a salvage procedure for epilepsy-related recurrent shoulder instability. A total of six patients with epilepsy underwent shoulder fusion for recurrent instability and were followed up for a mean of 39 months (12 to 79). The mean age at the time of surgery was 31 years (22 to 38). Arthrodesis was performed after a mean of four previous stabilisation attempts (0 to 11) in all but one patient in whom the procedure was used as a primary treatment. All patients achieved bony union, with a mean time to fusion of 2.8 months (2 to 7). There were no cases of re-dislocation. One revision was undertaken for loosening of the metalwork, and then healed satisfactorily. An increase was noted in the mean subjective shoulder value, which improved from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively although it decreased in two patients. The mean Oxford shoulder instability score improved from 13 pre-operatively (7 to 21) to 24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis eliminated recurrent instability and improved functional outcome. Fusion surgery should therefore be considered in this patient population. However, since the majority of patients are young and active, they should be comprehensively counselled pre-operatively given the functional deficit that results from the procedure.

Cite this article: Bone Joint J 2014;96-B:1525–9.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 20 - 21
1 Dec 2013

The December 2013 Wrist & Hand Roundup360 looks at: Scapholunate instability; three-ligament tenodesis; Pronator quadratus; Proximal row carpectomy; FPL dysfunction after volar plate fixation; Locating the thenar branch of the median nerve; Metallosis CMCJ arthroplasties; and timing of flap reconstruction


Bone & Joint 360
Vol. 4, Issue 4 | Pages 27 - 29
1 Aug 2015

The August 2015 Trauma Roundup360 looks at: Thromboprophylaxis not required in lower limb fractures; Subclinical thyroid dysfunction and fracture risk: moving the boundaries in fracture; Posterior wall fractures refined; Neurological injury and acetabular fracture surgery; Posterior tibial plateau fixation; Tibial plateau fractures in the longer term; Comprehensive orthogeriatric care and hip fracture; Compartment syndrome: in the eye of the beholder?


Bone & Joint Research
Vol. 2, Issue 12 | Pages 276 - 284
1 Dec 2013
Karlakki S Brem M Giannini S Khanduja V Stannard J Martin R

Objectives

The period of post-operative treatment before surgical wounds are completely closed remains a key window, during which one can apply new technologies that can minimise complications. One such technology is the use of negative pressure wound therapy to manage and accelerate healing of the closed incisional wound (incisional NPWT).

Methods

We undertook a literature review of this emerging indication to identify evidence within orthopaedic surgery and other surgical disciplines. Literature that supports our current understanding of the mechanisms of action was also reviewed in detail.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1307 - 1311
1 Oct 2014
Benninger E Zingg PO Kamath AF Dora C

To assess the sustainability of our institutional bone bank, we calculated the final product cost of fresh-frozen femoral head allografts and compared these costs with the use of commercial alternatives. Between 2007 and 2010 all quantifiable costs associated with allograft donor screening, harvesting, storage, and administration of femoral head allografts retrieved from patients undergoing elective hip replacement were analysed.

From 290 femoral head allografts harvested and stored as full (complete) head specimens or as two halves, 101 had to be withdrawn. In total, 104 full and 75 half heads were implanted in 152 recipients. The calculated final product costs were €1367 per full head. Compared with the use of commercially available processed allografts, a saving of at least €43 119 was realised over four-years (€10 780 per year) resulting in a cost-effective intervention at our institution. Assuming a price of between €1672 and €2149 per commercially purchased allograft, breakeven analysis revealed that implanting between 34 and 63 allografts per year equated to the total cost of bone banking.

Cite this article: Bone Joint J 2014;96-B:1307–11


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 694 - 698
1 May 2013
Benedetti Valentini M Farsetti P Martinelli O Laurito A Ippolito E

Of 48 consecutive children with Gartland III supracondylar fractures, 11 (23%) had evidence of vascular injury, with an absent radial pulse. The hand was pink and warm in eight and white and cold in the other three patients. They underwent colour-coded duplex scanning (CCDS) and ultrasound velocimetry (UV) to investigate the patency of the brachial artery and arterial blood flow. In seven patients with a pink pulseless hand, CCDS showed a displaced, kinked and spastic brachial artery and a thrombosis was present in the other. In all cases UV showed reduced blood flow in the hand. In three patients with a white pulseless hand, scanning demonstrated a laceration in the brachial artery and/or thrombosis. In all cases, the fracture was reduced under general anaesthesia and fixed with Kirschner wires. Of the seven patients with a pink pulseless hand without thrombosis, the radial pulse returned after reduction in four cases. The remaining three underwent exploration, along with the patients with laceration in the brachial artery and/or thrombosis.

We believe that the traditional strategy of watchful waiting in children in whom the radial pulse remains absent in spite of good peripheral perfusion should be revisited. Vascular investigation using these non-invasive techniques that are quick and reliable is recommended in the management of these patients.

Cite this article: Bone Joint J 2013;95-B:694–98.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 31 - 32
1 Jun 2015
York P Mauffrey C


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 871 - 874
1 Jul 2015
Breakwell LM Cole AA Birch N Heywood C

The effective capture of outcome measures in the healthcare setting can be traced back to Florence Nightingale’s investigation of the in-patient mortality of soldiers wounded in the Crimean war in the 1850s.

Only relatively recently has the formalised collection of outcomes data into Registries been recognised as valuable in itself.

With the advent of surgeon league tables and a move towards value based health care, individuals are being driven to collect, store and interpret data.

Following the success of the National Joint Registry, the British Association of Spine Surgeons instituted the British Spine Registry. Since its launch in 2012, over 650 users representing the whole surgical team have registered and during this time, more than 27 000 patients have been entered onto the database.

There has been significant publicity regarding the collection of outcome measures after surgery, including patient-reported scores. Over 12 000 forms have been directly entered by patients themselves, with many more entered by the surgical teams.

Questions abound: who should have access to the data produced by the Registry and how should they use it? How should the results be reported and in what forum?

Cite this article: Bone Joint J 2015;97-B:871–4.