Advertisement for orthosearch.org.uk
Results 101 - 120 of 155
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1381 - 1388
1 Oct 2017
Wong YW Samartzis D Cheung KMC Luk K

Aims

To address the natural history of severe post-tuberculous (TB) kyphosis, with focus upon the long-term neurological outcome, occurrence of restrictive lung disease, and the effect on life expectancy.

Patients and Methods

This is a retrospective clinical review of prospectively collected imaging data based at a single institute. A total of 24 patients of Southern Chinese origin who presented with spinal TB with a mean of 113° of kyphosis (65° to 159°) who fulfilled inclusion criteria were reviewed. Plain radiographs were used to assess the degree of spinal deformity. Myelography, CT and MRI were used when available to assess the integrity of the spinal cord and canal. Patient demographics, age of onset of spinal TB and interventions, types of surgical procedure, intra- and post-operative complications, and neurological status were assessed.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1289 - 1296
1 Oct 2018
Berliner JL Esposito CI Miller TT Padgett DE Mayman DJ Jerabek SA

Aims

The aims of this study were to measure sagittal standing and sitting lumbar-pelvic-femoral alignment in patients before and following total hip arthroplasty (THA), and to consider what preoperative factors may influence a change in postoperative pelvic position.

Patients and Methods

A total of 161 patients were considered for inclusion. Patients had a mean age of the remaining 61 years (sd 11) with a mean body mass index (BMI) of 28 kg/m2 (sd 6). Of the 161 patients, 82 were male (51%). We excluded 17 patients (11%) with spinal conditions known to affect lumbar mobility as well as the rotational axis of the spine. Standing and sitting spine-to-lower-limb radiographs were taken of the remaining 144 patients before and one year following THA. Spinopelvic alignment measurements, including sacral slope, lumbar lordosis, and pelvic incidence, were measured. These angles were used to calculate lumbar spine flexion and femoroacetabular hip flexion from a standing to sitting position. A radiographic scoring system was used to identify those patients in the series who had lumbar degenerative disc disease (DDD) and compare spinopelvic parameters between those patients with DDD (n = 38) and those who did not (n = 106).


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach.

We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis.

Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps.

Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (sd) 5.5), 0.3° valgus (sd 2.7), and 0.7° extension (sd 3.2) for the humeral component, and 9.3° pronation (sd 9.7), 0.3° valgus (sd 4.0), and 8.6° extension (sd 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs.

The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results.

Cite this article: 2015;97-B:1096–1101.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 544 - 553
1 Apr 2017
Nandra RS Wu F Gaffey A Bache CE

Aims

Following the introduction of national standards in 2009, most major paediatric trauma is now triaged to specialist units offering combined orthopaedic and plastic surgical expertise. We investigated the management of open tibia fractures at a paediatric trauma centre, primarily reporting the risk of infection and rate of union.

Patients and Methods

A retrospective review was performed on 61 children who between 2007 and 2015 presented with an open tibia fracture. Their mean age was nine years (2 to 16) and the median follow-up was ten months (interquartile range 5 to 18). Management involved IV antibiotics, early debridement and combined treatment of the skeletal and soft-tissue injuries in line with standards proposed by the British Orthopaedic Association.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1234 - 1239
1 Sep 2016
Yu HM Malhotra K Butler JS Patel A Sewell MD Li YZ Molloy S

Aims

Patients with multiple myeloma (MM) develop deposits in the spine which may lead to vertebral compression fractures (VCFs). Our aim was to establish which spinopelvic parameters are associated with the greatest disability in patients with spinal myeloma and VCFs.

Patients and Methods

We performed a retrospective cross-sectional review of 148 consecutive patients (87 male, 61 female) with spinal myeloma and analysed correlations between spinopelvic parameters and patient-reported outcome scores. The mean age of the patients was 65.5 years (37 to 91) and the mean number of vertebrae involved was 3.7 (1 to 15).


Bone & Joint Research
Vol. 5, Issue 11 | Pages 544 - 551
1 Nov 2016
Kim Y Bok DH Chang H Kim SW Park MS Oh JK Kim J Kim T

Objectives

Although vertebroplasty is very effective for relieving acute pain from an osteoporotic vertebral compression fracture, not all patients who undergo vertebroplasty receive the same degree of benefit from the procedure. In order to identify the ideal candidate for vertebroplasty, pre-operative prognostic demographic or clinico-radiological factors need to be identified. The objective of this study was to identify the pre-operative prognostic factors related to the effect of vertebroplasty on acute pain control using a cohort of surgically and non-surgically managed patients.

Patients and Methods

Patients with single-level acute osteoporotic vertebral compression fracture at thoracolumbar junction (T10 to L2) were followed. If the patients were not satisfied with acute pain reduction after a three-week conservative treatment, vertebroplasty was recommended. Pain assessment was carried out at the time of diagnosis, as well as three, four, six, and 12 weeks after the diagnosis. The effect of vertebroplasty, compared with conservative treatment, on back pain (visual analogue score, VAS) was analysed with the use of analysis-of-covariance models that adjusted for pre-operative VAS scores.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 387 - 392
1 Sep 2016
Morris WZ Fowers CA Yuh RT Gebhart JJ Salata MJ Liu RW

Objectives

The spinopelvic relationship (including pelvic incidence) has been shown to influence pelvic orientation, but its potential association with femoroacetabular impingement has not been thoroughly explored. The purpose of this study was to prove the hypothesis that decreasing pelvic incidence is associated with increased risk of cam morphology.

Methods

Two matching cohorts were created from a collection of cadaveric specimens with known pelvic incidences: 50 subjects with the highest pelvic incidence (all subjects > 60°) and 50 subjects with the lowest pelvic incidence (all subjects < 35°). Femoral version, acetabular version, and alpha angles were directly measured from each specimen bilaterally. Cam morphology was defined as alpha angle > 55°. Differences between the two cohorts were analysed with a Student’s t-test and the difference in incidence of cam morphology was assessed using a chi-squared test. The significance level for all tests was set at p < 0.05.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1410 - 1417
1 Oct 2016
Sinikumpu J Victorzon S Pokka T Lindholm E Peljo T Serlo W

Aims

We present the clinical and radiographic outcome of 81 children with Gartland type I to III supracondylar humeral fractures at a minimum follow-up of ten years (mean 12.1 years; 10.3 to 16.1) following injury.

Patients and Methods

The clinical and functional outcomes are compared with normal age- and gender-matched individuals. The population-based study setting was first identified from the institutional registries; the rate of participation was 76%. Controls were randomly selected from Finnish National Population Registry.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component.


Bone & Joint 360
Vol. 2, Issue 5 | Pages 29 - 31
1 Oct 2013

The October 2013 Spine Roundup360 looks at: Standing straighter may reduce falls; Operative management of congenital kyphosis; Athletic discectomy; Lumbar spine stenosis worsens with time; Flexible stabilisation?: spinal stenosis revisited; Do epidural steroids cause spinal fractures?; Who does well with cervical myelopathy?; Secretly adverse to BMP-2?


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 78 - 80
1 Jan 2016
Lee G

Patient specific instrumentation (PSI) uses advanced imaging of the knee (CT or MRI) to generate individualised cutting blocks aimed to make the procedure of total knee arthroplasty (TKA) more accurate and efficient. However, in this era of healthcare cost consciousness, the value of new technologies needs to be critically evaluated. There have been several comparative studies looking at PSI versus standard instrumentation. Most compare PSI with conventional instrumentation in terms of alignment in the coronal plane, operative time and surgical efficiency, cost effectiveness and short-term outcomes. Several systematic reviews and meta-analyses have also been published. PSI has not been shown to be superior compared with conventional instrumentation in its ability to restore traditional mechanical alignment in primary TKA. Most studies show comparative efficacy and no decrease in the number of outliers in either group. In terms of operative time and efficiency, PSI tended towards decreasing operative time, saving a mean of five minutes per patient (0 to 20). Furthermore, while some cost savings could be realised with less operative time and reduced instrumentation per patient, these savings were overcome by the cost of the CT/MRI and the cutting blocks. Finally, there was no evidence that PSI positively affected clinical outcomes at two days, two months, or two years. Consequently, current evidence does not support routine use of PSI in routine primary TKA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):78–80.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1025 - 1031
1 Aug 2008
Mizu-uchi H Matsuda S Miura H Okazaki K Akasaki Y Iwamoto Y

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans.

The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8° (174.2° to 188.3°), 88.5° (84.0° to 91.8°) and 89.7° (86.3° to 95.1°), respectively for the conventional group and 180.8° (178.2° to 185.1°), 89.3° (85.8° to 92.0°) and 89.9° (88.0° to 93.0°), respectively for the navigated group.

The mean sagittal femoral component angle was 85.5° (80.6° to 92.8°) for the conventional group and 89.6° (85.5° to 94.0°) for the navigated group.

The mean rotational femoral and tibial component angles were −0.7° (−8.8° to 9.8°) and −3.3° (−16.8° to 5.8°) for the conventional group and −0.6° (−3.5° to 3.0°) and 0.3° (−5.3° to 7.7°) for the navigated group.

The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 857 - 862
1 Jul 2014
Abdel MP Oussedik S Parratte S Lustig S Haddad FS

Substantial healthcare resources have been devoted to computer navigation and patient-specific instrumentation systems that improve the reproducibility with which neutral mechanical alignment can be achieved following total knee replacement (TKR). This choice of alignment is based on the long-held tenet that the alignment of the limb post-operatively should be within 3° of a neutral mechanical axis. Several recent studies have demonstrated no significant difference in survivorship when comparing well aligned versus malaligned TKRs. Our aim was to review the anatomical alignment of the knee, the historical and contemporary data on a neutral mechanical axis in TKR, and the feasibility of kinematically-aligned TKRs.

Review of the literature suggests that a neutral mechanical axis remains the optimal guide to alignment.

Cite this article: Bone Joint J 2014;96-B:857–62.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 12 - 14
1 Feb 2016


Bone & Joint Research
Vol. 5, Issue 3 | Pages 80 - 86
1 Mar 2016
Scott G Imam MA Eifert A Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives

Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back – a combination of movements which equates to tibial internal/ femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements in situ/in vivo.

Methods

The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m2 (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1238 - 1244
1 Sep 2010
Nicoll D Rowley DI

This study used CT analysis to determine the rotational alignment of 39 painful and 26 painless fixed-bearing total knee replacements (TKRs) from a cohort of 740 NexGen Legacy posterior-stabilised and cruciate-retaining prostheses implanted between May 1996 and August 2003.

The mean rotation of the tibial component was 4.3° of internal rotation (25.4° internal to 13.9° external rotation) in the painful group and 2.2° of external rotation (8.5° internal to 18.2° external rotation) in the painfree group (p = 0.024). In the painful group 17 tibial components were internally rotated more than 9° compared with none in the painfree group (p < 0.001). Additionally, six femoral components in the painful group were internally rotated more than 6° compared with none in the painfree group (p = 0.017). External rotational errors were not found to be associated with pain.

Overall, 22 (56.4%) of the painful TKRs had internal rotational errors involving the femoral, the tibial or both components. It is estimated that at least 4.6% of all our TKRs have been implanted with significant internal rotational errors.


We investigated the relationship between spinopelvic parameters and disc degeneration in young adult patients with spondylolytic spondylolisthesis. A total of 229 men with a mean age of 21 years (18 to 26) with spondylolytic spondylolisthesis were identified. All radiological measurements, including pelvic incidence, sacral slope, pelvic tilt, lumbar lordosis, sacral inclination, lumbosacral angle (LSA), and sacrofemoral distance, were calculated from standing lateral lumbosacral radiographs. The degree of intervertebral disc degeneration was classified using a modified Pfirrmann scale. We analysed the spinopelvic parameters according to disc level, degree of slip and disc degeneration.

There were significant positive correlations between the degree of slip and pelvic incidence (p = 0.009), sacral slope (p = 0.003) and lumbar lordosis (p = 0.010). The degree of slip and the LSA were correlated with disc degeneration (p < 0.001 and p = 0.003, respectively). There was also a significant difference between the degree of slip (p < 0.001) and LSA (p = 0.006) according to the segmental level of disc degeneration.

Cite this article: Bone Joint J 2013;95-B:1239–43.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 982 - 987
1 Jul 2015
Ganesan S Karampalis C Garrido E Tsirikos AI

Acute angulation at the thoracolumbar junction with segmental subluxation of the spine occurring at the level above an anteriorly hypoplastic vertebra in otherwise normal children is a rare condition described as infantile developmental thoracolumbar kyphosis. Three patient series with total of 18 children have been reported in the literature. We report five children who presented with thoracolumbar kyphosis and discuss the treatment algorithm. We reviewed the medical records and spinal imaging at initial clinical presentation and at minimum two-year follow-up. The mean age at presentation was eight months (two to 12). All five children had L2 anterior vertebral body hypoplasia. The kyphosis improved spontaneously in three children kept under monitoring. In contrast, the deformity was progressive in two patients who were treated with bracing. The kyphosis and segmental subluxation corrected at latest follow-up (mean age 52 months; 48 to 60) in all patients with near complete reconstitution of the anomalous vertebra. The deformity and radiological imaging on a young child can cause anxiety to both parents and treating physicians. Diagnostic workup and treatment algorithm in the management of infantile developmental thoracolumbar kyphosis is proposed. Observation is indicated for non-progressive kyphosis and bracing if there is evidence of kyphosis and segmental subluxation deterioration beyond walking age. Surgical stabilisation of the spine can be reserved for severe progressive deformities unresponsive to conservative treatment.

Cite this article: Bone Joint J 2015;97-B:982–7.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1435 - 1440
1 Oct 2015
Heidt C Hollander K Wawrzuta J Molesworth C Willoughby K Thomason P Khot A Graham HK

Pelvic obliquity is a common finding in adolescents with cerebral palsy, however, there is little agreement on its measurement or relationship with hip development at different gross motor function classification system (GMFCS) levels.

The purpose of this investigation was to study these issues in a large, population-based cohort of adolescents with cerebral palsy at transition into adult services.

The cohort were a subset of a three year birth cohort (n = 98, 65M: 33F, with a mean age of 18.8 years (14.8 to 23.63) at their last radiological review) with the common features of a migration percentage greater than 30% and a history of adductor release surgery.

Different radiological methods of measuring pelvic obliquity were investigated in 40 patients and the angle between the acetabular tear drops (ITDL) and the horizontal reference frame of the radiograph was found to be reliable, with good face validity. This was selected for further study in all 98 patients.

The median pelvic obliquity was 4° (interquartile range 2° to 8°). There was a strong correlation between hip morphology and the presence of pelvic obliquity (effect of ITDL on Sharpe’s angle in the higher hip; rho 7.20 (5% confidence interval 5.59 to 8.81, p < 0.001). This was particularly true in non-ambulant adolescents (GMFCS IV and V) with severe pelvic obliquity, but was also easily detectable and clinically relevant in ambulant adolescents with mild pelvic obliquity.

The identification of pelvic obliquity and its management deserves closer scrutiny in children and adolescents with cerebral palsy.

Cite this article: Bone Joint J 2015;97-B:1435–40.