Advertisement for orthosearch.org.uk
Results 1121 - 1140 of 1176
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 342 - 345
1 Mar 2007
Vaidya R Weir R Sethi A Meisterling S Hakeos W Wybo CD

We carried out a prospective study to determine whether the addition of a recombinant human bone morphogenetic protein (rhBMP-2) to a machined allograft spacer would improve the rate of intervertebral body fusion in the spine. We studied 77 patients who were to undergo an interbody fusion with allograft and instrumentation. The first 36 patients received allograft with adjuvant rhBMP-2 (allograft/rhBMP-2 group), and the next 41, allograft and demineralised bone matrix (allograft/demineralised bone matrix group). Each patient was assessed clinically and radiologically both pre-operatively and at each follow-up visit using standard methods. Follow-up continued for two years.

Every patient in the allograft/rhBMP-2 group had fused by six months. However, early graft lucency and significant (> 10%) subsidence were seen radiologically in 27 of 55 levels in this group. The mean graft height subsidence was 27% (13% to 42%) for anterior lumbar interbody fusion, 24% (13% to 40%) for transforaminal lumbar interbody fusion, and 53% (40% to 58%) for anterior cervical discectomy and fusion. Those who had undergone fusion using allograft and demineralised bone matrix lost only a mean of 4.6% (0% to 15%) of their graft height.

Although a high rate of fusion (100%) was achieved with rhBMP-2, significant subsidence occurred in more than half of the levels (23 of 37) in the lumbar spine and 33% (6 of 18) in the cervical spine. A 98% fusion rate (62 of 63 levels) was achieved without rhBMP-2 and without the associated graft subsidence. Consequently, we no longer use rhBMP-2 with allograft in our practice if the allograft has to provide significant structural support.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1293 - 1298
1 Oct 2007
Steffen R O’Rourke K Gill HS Murray DW

In 12 patients, we measured the oxygen concentration in the femoral head-neck junction during hip resurfacing through the anterolateral approach. This was compared with previous measurements made for the posterior approach. For the anterolateral approach, the oxygen concentration was found to be highly dependent upon the position of the leg, which was adjusted during surgery to provide exposure to the acetabulum and femoral head. Gross external rotation of the hip gave a significant decrease in oxygenation of the femoral head. Straightening the limb led to recovery in oxygen concentration, indicating that the blood supply was maintained. The oxygen concentration at the end of the procedure was not significantly different from that at the start.

The anterolateral approach appears to produce less disruption to the blood flow in the femoral head-neck junction than the posterior approach for patients undergoing hip resurfacing. This may be reflected subsequently in a lower incidence of fracture of the femoral neck and avascular necrosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1488 - 1494
1 Nov 2007
Gorodetskyi IG Gorodnichenko AI Tursin PS Reshetnyak VK Uskov ON

We undertook a trial on 60 patients with AO 31A2 fractures of the hip who were randomised after stabilisation of the fracture into two equal groups, one of which received post-operative treatment using a non-invasive interactive neurostimulation device and the other with a sham device. All other aspects of their rehabilitation were the same. The treatment was continued for ten days after operation.

Outcome measurements included the use of a visual analogue scale for pain, the brief pain inventory and Ketorolac for post-operative control of pain, and an overall assessment of outcome by the surgeon. There were significantly better results for the patients receiving treatment by active electrical stimulation (repeated measures analysis of variance, p < 0.001). The findings of this pilot trial justify a larger study to determine if these results are more generally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 588 - 588
1 Apr 2005
LANGDOWN AJ AULD J BRUCE WJM


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1019 - 1024
1 Aug 2007
Hing CB Young DA Dalziel RE Bailey M Back DL Shimmin AJ

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing.

There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5° (80° to 160°). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60).

We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 377 - 379
1 Mar 2006
Barker SL Lavy CBD

Achilles tenotomy is a recognised step in the Ponseti technique for the correction of idiopathic congenital talipes equinovarus in most percutaneous cases. Its use has been limited in part by concern that the subsequent natural history of the tendon is unknown. In a study of 11 tendons in eight infants, eight tendons were shown to be clinically intact and ten had ultrasonographic evidence of continuity three weeks after tenotomy. At six weeks after tenotomy all tendons had both clinical and ultrasonographic evidence of continuity.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 1 - 4
1 Jan 2007
Robertsson O

This article considers the establishment, purpose and conduct of knee arthroplasty registers using the Swedish register as an example. The methods of collection of appropriate data, the cost, and the ways in which this information may be used are considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1178 - 1182
1 Sep 2006
Stanley JK Penn DS Wasseem M

Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human cadavers. An osteotomy of the supinator tuberosity was performed and reflected as a single unit with the attached annular ligament. Excellent exposure of the head of the radius was achieved, replacement of the head was undertaken and the osteotomy site repaired. The elbows were stable and had a full range of movement. The approach was then carried out on 13 patients for elective replacement of the head and was found to be safe and reproducible. In the patient group all osteotomies united, the elbows were stable and had an improved range of supination and pronation. There was no change in flexion and extension of the elbow. Complications included a haematoma and a reflex sympathetic dystrophy.

The modified posterior approach provides excellent access to the head and neck of the radius, gives good stability of the elbow and allows early mobilisation of the joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 580 - 585
1 May 2007
Crowley DJ Kanakaris NK Giannoudis PV

Modern principles for the treatment of open fractures include stabilisation of the bone and management of the soft tissues. Wound debridement and irrigation is thought to be the mainstay in reducing the incidence of infection. Although numerous studies on animals and humans have focused on the type of irrigation performed, little is known of the factors which influence irrigation. This paper evaluates the evidence, particularly with regard to additives and the mode of delivery of irrigation fluid.

Normal saline should be used and although many antiseptics and antibiotics have been employed, no consensus has been reached as to the ideal additive. Despite the advocates of high-pressure methods highlighting the improved dilutional ability of such techniques, the results are inconclusive and these irrigation systems are not without complications.

New systems for debridement are currently being investigated, and an ideal method has yet to be determined.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 408 - 412
1 Mar 2007
Ma H Lu Y Kwok T Ho F Huang C Huang C

One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines.

The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58°; 0.14° to 29.9°) and with its own patellar component (mean 11.36°; 0.55° to 39.19°). In the other four prostheses, the conformity was better (mean 2.25°; 0.02° to 10.52°) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51°; 0.07° to 9.89°) than the Miller-Galante II prosthesis (mean 11.20°; 5.80° to 16.72°) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57°; 1.40° to 4.56°) or high angles of flexion (mean 4.54°; 0.91° to 9.39°), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39°; 0.04° to 4.56°). There was no significant difference (p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion.

The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1102 - 1104
1 Aug 2006
Wenke JC Owens BD Svoboda SJ Brooks DE

The aim of this study was to determine the effectiveness of antibiotic-impregnated implants in the prevention of bone infection. We used a model of contaminated fracture in goats to evaluate four treatment groups: no treatment, hand-made tobramycin-impregnated polymethylmethacrylate beads, commercially-available tobramycin-impregnated calcium sulphate pellets and commercially-available tobramycin-impregnated polymethylmethacrylate beads. Three weeks after intraosseous inoculation with streptomycin-resistant Staphylococcus aureus tissue cultures showed no evidence of infection in any of the antibiotic-treated groups. All of the cultures were positive in the untreated group. These results show that effective local antibiotic delivery can be obtained with both commercially-available products and with hand-made polymethylmethacrylate beads. The calcium sulphate pellets have the advantage of being bioabsorbable, thereby obviating the need for a second procedure to remove them.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1448 - 1448
1 Oct 2005


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1620 - 1626
1 Dec 2007
Toma CD Machacek P Bitzan P Assadian O Trieb K Wanivenhaus A

We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months.

Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% vs 37%, p = 0.015). Complications were reported in six wrists in the AO-plate group and two wrists in the Mannerfelt fusion group (p = 0.258). At final follow-up, 95% of patients (41) reported either no pain or only mild pain. There was improvement in flexion of the finger joints in both groups but no significant improvement in the extension lag in either group.

Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative complications occurred in the AO-plate group, the difference between the two groups was not statistically significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 411 - 421
1 Apr 2008
Pollard TCB Gwilym SE Carr AJ

Treatment strategies for osteoarthritis most commonly involve the removal or replacement of damaged joint tissue. Relatively few treatments attempt to arrest, slow down or reverse the disease process. Such options include peri-articular osteotomy around the hip or knee, and treatment of femoro-acetabular impingement, where early intervention may potentially alter the natural history of the disease. A relatively small proportion of patients with osteoarthritis have a clear predisposing factor that is both suitable for modification and who present early enough for intervention to be deemed worthwhile. This paper reviews recent advances in our understanding of the pathology, imaging and progression of early osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 57 - 61
1 Jan 2007
Lee ST Song HR Mahajan R Makwana V Suh SW Lee SH

Genu varum in the achondroplastic patient has a complex and multifactorial aetiology. There is little mention in the literature of the role of fibular overgrowth. Using the ratio of fibular to tibial length as a measurement of possible fibular overgrowth, we have related it to the development of genu varum. Full-length standing anteroposterior radiographs of 53 patients with achondroplasia were analysed. There were 30 skeletally-immature and 23 skeletally-mature patients. Regression analysis was performed in order to determine if there was a causal relationship between fibular overgrowth and the various indices of alignment of the lower limb.

Analysis showed that the fibular to tibial length ratio had a significant correlation with the medial proximal tibial angle and the mechanical axial deviation in the skeletally-immature group. We conclude that there is a significant relationship between fibular overgrowth and the development of genu varum in the skeletally-immature achondroplastic patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 760 - 764
1 Jun 2006
Dotzis A Cochu G Mabit C Charissoux JL Arnaud JP

Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis.

This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant complication occurred in one patient who developed a severe complex regional pain syndrome. There were no patients with secondary instability of the elbow, implant loosening, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. Our experience, combined with that of other authors using this device, has encouraged us to continue using the Judet prosthesis in comminuted fractures of the elbow where instability is a potential problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 888 - 888
1 Jun 2005


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1449 - 1451
1 Nov 2005
Benson MKD Bourne R Hanley E Harrison J Jodoin A Nicol R van Wyk L Weinstein PS


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 9 - 15
1 Jan 2007
Beaulé PE Harvey N Zaragoza E Le Duff MJ Dorey FJ

Because the femoral head/neck junction is preserved in hip resurfacing, patients may be at greater risk of impingement, leading to abnormal wear patterns and pain. We assessed femoral head/neck offset in 63 hips undergoing metal-on-metal hip resurfacing and in 56 hips presenting with non-arthritic pain secondary to femoroacetabular impingement. Most hips undergoing resurfacing (57%; 36) had an offset ratio ≤ 0.15 pre-operatively and required greater correction of offset at operation than the rest of the group. In the non-arthritic hips the mean offset ratio was 0.137 (0.04 to 0.23), with the offset ratio correlating negatively to an increasing α angle. An offset ratio ≤ 0.15 had a 9.5-fold increased relative risk of having an α angle ≥ 50.5°. Most hips undergoing resurfacing have an abnormal femoral head/neck offset, which is best assessed in the sagittal plane.