The paper reports an experimental investigation into the mechanisms whereby the joints of living animals maintain their precise contours. The normal patter of joint incongruity in the rabbit's hip having first been established, three groups of experimental animals underwent operative procedures designed to reduce the joint pressure to a level unrealistic in normal life. In one group the hip was dislocated by manipulation; in a second group the muscles around the hip joint were divided; and in a third group the hind
The effects of gamma irradiation on the growth plate have been studied in nineteen rabbits with a 1,000 rads/skin dose. The rabbits were killed after one to ninety days. The growth plates were studied by microscopic examination, thymidine-H3 autoradiography, and fluorescence with radiographic measurement. Changes were already detected after twenty-four hours at the cell mitosis level, which showed the sensitiveness of the chondrocyte itself. The lesions were clearly seen with the optical microscope after seven days, and they were most advanced between the fourteenth and twenty-first day after irradiation. Regeneration of the cartilage began in the fourth week and the histological appearance became normal after seventy days. Fluorescence with tetracycline showed a temporary retardation of growth, with consequent shortening of the affected
1. The normal vascular anatomy of flexor tendons and extensor tendons in the hind
At the time of publication sixty-three additional patients have been fitted with the patellar tendon bearing prosthesis. Twenty of these were new amputees, and forty-three were old amputees who had previously worn a conventional
The aim of this study was to report the clinical, functional
and radiological outcomes of children and adolescents with tibial
fractures treated using the Ilizarov method. Between 2013 and 2016 a total of 74 children with 75 tibial fractures
underwent treatment at our major trauma centre using an Ilizarov
frame. Demographic and clinical information from a prospective database
was supplemented by routine functional and psychological assessment
and a retrospective review of the notes and radiographs.Aims
Patients and Methods
In 251 patients over a period of 15 years an uncemented Kotz modular femoral and tibial reconstruction mega prosthesis was implanted after resection of a malignant tumour of the lower limb. Twenty-one patients (8.4%) underwent revision for aseptic loosening, again using an uncemented prosthesis, and five of these required a further revision procedure. The median follow-up time from the first revision was 60 months (11 to 168) and after a second revision, 33 months (2 to 50). The probability of a patient avoiding aseptic loosening for ten years was 96% for a proximal femoral, 76% for a distal femoral and 85% for a proximal tibial implant. At the time of follow-up all radiographs were assessed according to the International Symposium of
The aims of this study were to quantify health state utility
values (HSUVs) after a tibial fracture, investigate the effect of
complications, to determine the trajectory in HSUVs that result
in these differences and to quantify the quality-adjusted life years
(QALYs) experienced by patients. This is an analysis of 2138 tibial fractures enrolled in the
Fluid Lavage of Open Wounds (FLOW) and Study to Prospectively Evaluate
Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT)
trials. Patients returned for follow-up at two and six weeks and
three, six, nine and 12 months. Short-Form Six-Dimension (SF-6D) values
were calculated and used to calculate QALYs.Aims
Patients and Methods
We immobilised the right hindlimbs of six-month-old female Wistar rats for four weeks using a biplanar external fixation bridging the knee. The untreated left
We have carried out prosthetic reconstruction in six patients with malignant or aggressively benign bone tumours of the distal tibia or fibula. The diagnoses were osteosarcoma in four patients, parosteal osteosarcoma in one and recurrent giant-cell tumour in one. Five tumours were in the distal tibia and one in the distal fibula. The mean duration of follow-up was 5.3 years (2.0 to 7.1). Reconstruction was achieved using custom-made, hinged prostheses which replaced the distal tibia and the ankle. The mean range of ankle movement after operation was 31° and the joints were stable. The average functional score according to the system of the International Society of
Six normal cadaver lower limbs were mounted on a specially designed loading apparatus. Wires were used to simulate the five muscle bellies of the quadriceps, the ratio of their tensions having been determined from that of the anatomical cross-sectional areas of the muscles. A three-camera system was used to track the patella during knee movements from flexion to extension. The patellofemoral contact area was determined by pressure-sensitive film. The
The aim of this study was to compare the cost-effectiveness of
treatment with an osseointegrated percutaneous (OI-) prosthesis
and a socket-suspended (S-) prosthesis for patients with a transfemoral
amputation. A Markov model was developed to estimate the medical costs and
changes in quality-adjusted life-years (QALYs) attributable to treatment
of unilateral transfemoral amputation over a projected period of
20 years from a healthcare perspective. Data were collected alongside
a prospective clinical study of 51 patients followed for two years.Aims
Patients and Methods
A continuous ambulatory activity monitor allows objective measurement of the amount and intensity of physical activity. We examined the reliability and validity of this device in the assessment of seven aspects of function over a period of 24 hours in 20 patients who had undergone
The objective of this study was to compare early postoperative
functional outcomes and time to hospital discharge between conventional
jig-based total knee arthroplasty (TKA) and robotic-arm assisted
TKA. This prospective cohort study included 40 consecutive patients
undergoing conventional jig-based TKA followed by 40 consecutive
patients receiving robotic-arm assisted TKA. All surgical procedures
were performed by a single surgeon using the medial parapatellar
approach with identical implant designs and standardized postoperative inpatient
rehabilitation. Inpatient functional outcomes and time to hospital
discharge were collected in all study patients.Aims
Patients and Methods
Giant-cell tumour of the tendon sheath (GCT-TS) is a benign solitary tumour which usually arises in the
Angular deformities of the distal radius of 15 sheep were induced by asymmetrical epiphysial distraction. Eleven sheep were between 10 and 20 weeks old; four were older than 24 weeks. Gradual distraction on the medial side of the
A model of tourniquet ischaemia was developed in the hind
A series of 29 patients with fractures of the tibial plateau were treated by means of a cast-brace. There were seven wedge fractures of the lateral tibial condyle, two dicondylar fractures and 20 compression fractures involving the lateral tibial plateau. The seven patients with wedge fractures were treated by skin or skeletal traction, followed as soon as possible by flexion exercises for the knee. Cast-braces were applied to all fractures as soon as possible after injury, and the patients allowed to bear weight freely. Early restoration of function of the injured
Failure of union of the tibia with a large defect is difficult to treat, especially in the presence of sepsis and adherent scars. Conventional methods of fixation and bone grafting are not easily applicable. Experiments on Macaca monkeys showed that a vascularised pedicle graft of the shaft of the ipsilateral fibula could be fixed across a defect in the tibia and remain viable, even if it was isolated from surrounding soft tissues. Transfer of part of the shaft of the ipsilateral fibula on a vascular and muscle pedicle was carried out in 11 patients with large tibial defects and sepsis. There was one failure because of severe infection, but the other 10 patients gained sound union in about four months. The tibia was then protected by a caliper for the 18 months of full reconstitution. The bone infection healed and there was no evidence of avascular necrosis. Although the salvaged
1. Stainless steel mould arthroplasty of the knee is described and a ten-year follow-up study of sixty-two operations is reported. Fifty-four were for rheumatoid arthritis and eight for osteoarthritis. 2. Forty-nine of the sixty-two joints retained mobility, six had become ankylosed and five were later arthrodesed ; two
1. It appears that fracture of the humeral shaft occurs more often in persons over fifty. This incidence corresponds with that found in a study carried out by the Pennsylvania Orthopaedic Society in 1959. 2. The middle third of the bone is the most vulnerable portion of the shaft, where transverse fracture and radial nerve palsy most commonly occur. 3. Most fractures of the shaft of the humerus are best treated by simple splintage. The degree of radiological deformity that can be accepted is far greater than in other long bones. In this group anterior bowing of 20 degrees or varus of 30 degrees was present before it became clinically obvious and even then the function of the