Advertisement for orthosearch.org.uk
Results 1101 - 1120 of 2210
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 288 - 291
1 Mar 2003
Sampathkumar K Jeyam M Evans CE Andrew JG

Aseptic loosening of orthopaedic implants is usually attributed to the action of wear debris from the prosthesis. Recent studies, however, have also implicated physical pressures in the joint as a further cause of loosening. We have examined the role of both wear debris and pressure on the secretion of two chemokines, MIP-1α and MCP-1, together with M-CSF and PGE2, by human macrophages in vitro. The results show that pressure alone stimulated the secretion of more M-CSF and PGE. 2. when compared with control cultures. Particles alone stimulated the secretion of M-CSF and PGE. 2. , when compared with unstimulated control cultures, but did not stimulate the secretion of the two chemokines. Exposure of macrophages to both stimuli simultaneously had no synergistic effect on the secretion of the chemokines, but both M-CSF and PGE. 2. were increased in a synergistic manner. Our findings suggest that pressure may be an initiating factor for the recruitment of cells into the periprosthetic tissue


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1156 - 1160
1 Nov 2001
Donati D Zavatta M Gozzi E Giacomini S Campanacci L Mercuri M

We describe 25 patients who were treated for a tumour of the proximal femur by resection and replacement with an uncemented, bipolar, modular prosthesis. When followed up after more than ten years four prostheses (16%) had required revision. Two joints showed wear and another necrosis of the acetabulum. One patient with loosening of the stem had been treated by radiotherapy to the femur. Articular cartilage seemed to be a reliable barrier to acetabular wear. Very few signs of the formation of particulate debris were observed. The most obvious feature in the bone-stem relationship was stress shielding, seen as osteoporosis of the proximal part of the femur around the stem in 68%. Functional activity was satisfactory in 68% of the patients. A better system of reattachment of the soft tissues is needed to avoid pain and a persistent limp


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1075 - 1081
1 Sep 2001
Doherty AT Howell RT Ellis LA Bisbinas I Learmonth ID Newson R Case CP

The long-term biological effects of wear debris are unknown. We have investigated whether there is any evidence of cumulative mutagenic damage in peripheral blood lymphocytes of patients undergoing revision arthroplasty of predominantly metal-on-plastic total hip replacements compared with those at primary arthroplasty. There was a threefold increase in aneuploidy and a twofold increase in chromosomal translocations which could not be explained by the confounding variables of smoking, gender, age and diagnostic radiographs. In the patients with TiVaAl prostheses there was a fivefold increase in aneuploidy but no increase in chromosomal translocations. By contrast, in patients with cobalt-chrome prostheses there was a 2.5-fold increase in aneuploidy and a 3.5-fold increase in chromosomal translocations. In six patients with stainless-steel prostheses there was no increase in either aneuploidy or chromosomal translocations. Our results suggest that future epidemiological studies of the putative long-term risks of joint replacement should take into account the type of alloy used in the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1126 - 1130
1 Nov 2002
Ashraf T Newman JH Evans RL Ackroyd CE

We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis. At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period. We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%. Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable unicompartmental replacement for isolated lateral compartment osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 656 - 661
1 Aug 1987
Ross A Wilson J Scales J

Endoprosthetic replacement of the proximal humerus has been performed in our unit on 25 occasions between 1950 and 1982. The indication for surgery was destruction of the proximal half of the humerus so extensive that the only alternatives were reconstruction or amputation. Of the patients with tumours two died from metastases, and three from unrelated causes; local recurrence necessitated amputation in two patients. Minor complications were frequent, but there were no deep infections and, after 1964, no prosthesis became loose. Active shoulder movement after operation was considerably limited, but passive movement was good and function of the elbow and hand were preserved


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1123 - 1127
1 Nov 2003
Akizuki S Takizawa T Horiuchi H

Miller-Galante II total knee arthroplasty (MG II TKA) was performed on 32 knees in 30 patients. On both the femoral and tibial components, the fibre-metal area was plasma-sprayed with hydroxyapatite-tricalcium phosphate (HA-TCP). The clinical and radiographic outcome was evaluated. A mean pre-operative knee score of 26.0 ± 18.6 (SD) increased to 97.5 ± 3.5 and a mean pre-operative functional score of 21.7 ± 15.0 (SD) increased to 83.4 ± 12.4 at follow-up of seven years. Clear zones were common around the components at one month post-operatively but had completely disappeared after six months. An autopsy of a patient who underwent MG II TKA with HA-TCP two years previously, showed osteogenesis in all parts of the fibre-metal, and bone tissue comprised 77.7% of the interface. This coated prosthesis has good early fixation which is maintained at seven years with good clinical and radiographic outcomes


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 749 - 754
1 Jun 2018
Partridge DG Winnard C Townsend R Cooper R Stockley I

Aims

The aim of this study was to establish the diagnostic accuracy of culture of joint aspirate with and without saline injection-reaspiration.

Patients and Methods

This is a retrospective analysis of 580 hip and knee aspirations in patients who were deemed to have a moderate to high risk of infection, and who subsequently proceeded to revision arthroplasty over a period of 12 years. It was carried out at a large quaternary referral centre where preoperative aspiration is routine.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 703 - 711
1 Jun 2018
Marson BA Deshmukh SR Grindlay DJC Scammell BE

Aims

The aim of this review was to evaluate the available literature and to calculate the pooled sensitivity and specificity for the different alpha-defensin test systems that may be used to diagnose prosthetic joint infection (PJI).

Materials and Methods

Studies using alpha-defensin or Synovasure (Zimmer Biomet, Warsaw, Indiana) to diagnose PJI were identified from systematic searches of electronic databases. The quality of the studies was evaluated using the Quality Assessment of Studies of Diagnostic Accuracy (QUADAS) tool. Meta-analysis was completed using a bivariate model.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 385 - 387
1 May 1997
Grohs JG Gottsauner-Wolf F

We studied the detection of joint replacements at airport security checks in relation to their weight, using two types of detector arch. A single-source, unilateral detector showed different sensitivities for implants on different sides of a test subject. All implants weighing more than 145 g were detected by one of the arches. The degree of detection was directly related to the logarithm of the weight of the prosthesis in patients, with a linear correlation (r. 2. = 0.61). A bilateral arch detected all prostheses weighing over 195 g. With their usual sensitivity settings many joint replacements were detectable; an identification pass containing the site and weight of such prostheses would help to avoid the need for body-search procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 824 - 829
1 Aug 2004
Watanabe H Akizuki S Takizawa T

We performed a prospective study of 54 patients (76 knees) who underwent Osteonics series 3000 cruciate-retaining cementless total knee arthroplasty between December 1990 and June 1993. Five patients (seven knees) were lost to follow-up (90.7% completion). One patient required revision at 10.5 years after operation. The rate of survival was 100% at ten years and 96.7% at 13 years. The mean ten-year knee and function scores were 79 and 59 respectively. Both were significantly better than the pre-operative scores. The range of movement also improved. Although a radiolucent line around the tibial component enlarged in six knees (20.7%) at ten years, the clinical outcome was generally good. In a patient who died after 5.5 years, post-mortem examination of the knee showed no bony ingrowth into the tibial component. Despite poor bony ingrowth, press-fit fixation was satisfactory and good results can be obtained with this cementless, cruciate-retaining prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 641 - 645
1 Jul 2003
Pieringer H Labek G Auersperg V Böhler N

We reviewed 80 patients (87 hips) who were older than 80 years of age at the time of cementless total hip arthroplasty. An Alloclassic SL stem had been implanted in all patients. A variety of cementless acetabular components was used. After a mean follow-up of 69.3 months (39.2 to 94.1) 48 hips in 43 patients were analysed clinically and radiologically. One patient had sustained a traumatic periprosthetic fracture of the femur with subsequent exchange of the stem 73 months after operation. Thirty-two patients (34 hips) had died and five patients (five hips) were unavailable for follow-up because of health reasons (four patients) or lack of co-operation (one patient). If the endpoint is defined as removal of the prosthesis because of aseptic loosening, the survival rate was 100% for the cup and stem after 78 months. The mean Harris hip score was 81.9 points. Radiolucent lines and osteolysis were seldom found


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 927 - 933
1 Jul 2017
Poltaretskyi S Chaoui J Mayya M Hamitouche C Bercik MJ Boileau P Walch G

Aims

Restoring the pre-morbid anatomy of the proximal humerus is a goal of anatomical shoulder arthroplasty, but reliance is placed on the surgeon’s experience and on anatomical estimations. The purpose of this study was to present a novel method, ‘Statistical Shape Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy and calculates the 3D geometric parameters needed to restore normal anatomy in patients with severe degenerative osteoarthritis or a fracture of the proximal humerus.

Materials and Methods

From a database of 57 humeral CT scans 3D humeral reconstructions were manually created. The reconstructions were used to construct a statistical shape model (SSM), which was then tested on a second set of 52 scans. For each humerus in the second set, 3D reconstructions of four diaphyseal segments of varying lengths were created. These reconstructions were chosen to mimic severe osteoarthritis, a fracture of the surgical neck of the humerus and a proximal humeral fracture with diaphyseal extension. The SSM was then applied to the diaphyseal segments to see how well it predicted proximal morphology, using the actual proximal humeral morphology for comparison.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 452 - 455
1 May 1989
Nunn D Freeman M Tanner K Bonfield W

Torsional instability of femoral components has not received much attention, and is difficult to detect in conventional radiographs. To test this we designed a system to apply a load in an anteroposterior direction to the head of a femoral component, implanted into a cadaveric femur. Rotation within the bone was measured, using a purpose built transducer, with and without preservation of the neck, with and without cement, and with longitudinal ridges but no cement. The results show that torsional instability may be a problem in uncemented replacement. Preservation of the femoral neck and the use of a ridged prosthesis increases resistance to rotation. Rotational movements occurring in vivo during such activities as climbing stairs and rising from the seated position may contribute to mechanical loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 270 - 273
1 Mar 1995
Dielissen P Claassen A Veldman P Goris R

We have reviewed 28 patients with reflex sympathetic dystrophy (RSD) who had 34 amputations in 31 limbs. The amputations had been performed for untenable pain (5), recurrent infection (14) or to improve residual function (15). Only two patients were relieved of pain by amputation, and this could not be predicted. Ten of 14 patients were cured of infection and 9 of 15 patients had improvement of residual function. In 28 of the amputations, RSD recurred in the stump, especially after amputation at a level which was not free from symptoms. Because of recurrence of RSD in the stump or severe hyperpathia only two patients wear a prosthesis. Despite this 24 patients were satisfied with the results


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 198 - 199
1 Mar 1994
Dandy D Desai S

We studied changes in patellar tendon length after reconstruction of the anterior cruciate ligament using either the medial third of the patellar tendon as a graft (n = 40) or a Leeds-Keio artificial ligament (n = 40). Both types of ligament replacement had been supplemented with a MacIntosh extra-articular lateral substitution. The mean change in length in the tendon graft group was 6% (SD 5.39); in the Leeds-Keio group it was 2.4% (SD 4.93). The change in length was significant in both groups, but shortening was more frequent and more severe in the tendon graft group. There was shortening of 10% or more in 25% of knees after patellar tendon graft and 7.5% after use of a Leeds-Keio prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 240 - 243
1 Mar 2003
Kulkarni A Fiorenza F Grimer RJ Carter SR Tillman RM

Ten patients underwent endoprosthetic replacement of the distal humerus for bone tumours over a period of 30 years. There were eight primary and two secondary tumours in four men and six women with a mean age of 47.5 years (15 to 76). The mean follow-up was eight years (9 months to 31 years). Four patients required further surgery, three having revision for aseptic loosening; two of these and one other later needing a rebushing. There were no cases of postoperative nerve palsy, infection, local recurrence or mechanical failure of the implant. Four patients died from their disease, all with the prosthesis functioning satisfactorily. At follow-up the mean flexion deformity of the elbow was 15° (0 to 35) and the mean range of flexion was 115° (110 to 135). The functional results showed a mean Toronto extremity salvage score of 73% of normal. Endoprosthetic replacement of the distal humerus and elbow is a satisfactory method of treating these rare tumours


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 461 - 467
1 May 1996
Gaine WJ McCreath SW

We assessed 46 Syme’s amputees attending our prosthetic clinics in terms of the clinical and radiological condition of their stumps, their level of function and problems with the prosthesis. Twenty-five were compared with a matching group of 25 transtibial amputees in regard to activity, function and prosthetic behaviour. Function was similar in the two groups, but Syme’s amputees had a higher incidence of prosthetic failure. Overall, Syme’s amputees were pleased with their prostheses and their function. Childhood amputations were associated with fewer long-term problems in terms of function and stump problems. Syme’s amputation is indicated for congenital foot deformities, fibular hemimelia and severe injury to the foot as long as the heel pad remains viable


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 210 - 212
1 Mar 1996
Laupacis A Rorabeck C Bourne R Tugwell P Bullas R Rankin R Vellet AD Feeny D Wong C

We randomised 250 patients undergoing unilateral, elective hip arthroplasty for osteoarthritis to receive either a cemented or a non-cemented Mallory Head prosthesis. Aspirin was used as prophylaxis against thromboembolism during the first half of the study and adjusted-dose warfarin during the second half. Postoperatively, all patients were asked to have bilateral venography and 80% agreed. All were evaluated clinically for pulmonary embolism. There was no difference in the frequency of deep-venous thrombosis between the two groups (50% cemented v 47% non-cemented, p = 0.73; 95% CI of the difference −13.6% to 19.3%). Three of the 64 patients (5%) in whom venography had demonstrated isolated distal thrombi developed pulmonary emboli


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 66 - 72
1 Jan 2018
Suen K Keeka M Ailabouni R Tran P

Aims

α-defensin is a biomarker which has been described as having a high degree of accuracy in the diagnosis of periprosthetic joint infection (PJI). Current meta-analyses are based on the α-defensin laboratory-based immunoassay rather than the quick on-table lateral flow test kit. This study is the first meta-analysis to compare the accuracy of the α-defensin laboratory-based immunoassay and the lateral flow test kit for the diagnosis of PJI.

Materials and Methods

A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Inclusion criteria were all clinical studies where the diagnosis of PJI was uncertain. All studies selected used the Musculoskeletal Infection Society (MSIS) or modified MSIS criteria. Two independent reviewers reviewed the studies and extracted data. A meta-analysis of results was carried out: pooled sensitivity, specificity, positive and negative likelihood ratio, heterogeneity and areas under curves are reported.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 734 - 739
1 Jun 2006
Campbell DG Duncan WW Ashworth M Mintz A Stirling J Wakefield L Stevenson TM

A series of 100 consecutive osteoarthritic patients was randomised to undergo total knee replacement using a Miller-Galante II prosthesis, with or without a cemented polyethylene patellar component. Knee function was evaluated using the American Knee Society score, Western Ontario and McMaster University Osteoarthritis index, specific patellofemoral-related questions and radiographic evaluation until the fourth post-operative year, then via questionnaire until ten years post-operatively. A ten-point difference in the American Knee Society score between the two groups was considered a significant change in knee performance, with α and β levels of 0.05. The mean age of the patients in the resurfaced group was 71 years (53 to 88) and in the non-resurfaced group was 73 years (54 to 86). After ten years 22 patients had died, seven were suffering from dementia, three declined further participation and ten were lost to follow-up. Two patients in the non-resurfaced group subsequently had their patellae resurfaced. In the resurfaced group one patient had an arthroscopic lateral release. There was no significant difference between the two treatment groups: both had a similar deterioration of scores with time, and no further patellofemoral complications were observed in either group. We are unable to recommend routine patellar resurfacing in osteoarthritic patients undergoing total knee replacement on the basis of our findings