Aseptic loosening of orthopaedic implants is usually attributed to the action of wear debris from the
We describe 25 patients who were treated for a tumour of the proximal femur by resection and replacement with an uncemented, bipolar, modular
The long-term biological effects of wear debris are unknown. We have investigated whether there is any evidence of cumulative mutagenic damage in peripheral blood lymphocytes of patients undergoing revision arthroplasty of predominantly metal-on-plastic total hip replacements compared with those at primary arthroplasty. There was a threefold increase in aneuploidy and a twofold increase in chromosomal translocations which could not be explained by the confounding variables of smoking, gender, age and diagnostic radiographs. In the patients with TiVaAl prostheses there was a fivefold increase in aneuploidy but no increase in chromosomal translocations. By contrast, in patients with cobalt-chrome prostheses there was a 2.5-fold increase in aneuploidy and a 3.5-fold increase in chromosomal translocations. In six patients with stainless-steel prostheses there was no increase in either aneuploidy or chromosomal translocations. Our results suggest that future epidemiological studies of the putative long-term risks of joint replacement should take into account the type of alloy used in the
We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled
Endoprosthetic replacement of the proximal humerus has been performed in our unit on 25 occasions between 1950 and 1982. The indication for surgery was destruction of the proximal half of the humerus so extensive that the only alternatives were reconstruction or amputation. Of the patients with tumours two died from metastases, and three from unrelated causes; local recurrence necessitated amputation in two patients. Minor complications were frequent, but there were no deep infections and, after 1964, no
Miller-Galante II total knee arthroplasty (MG II TKA) was performed on 32 knees in 30 patients. On both the femoral and tibial components, the fibre-metal area was plasma-sprayed with hydroxyapatite-tricalcium phosphate (HA-TCP). The clinical and radiographic outcome was evaluated. A mean pre-operative knee score of 26.0 ± 18.6 (SD) increased to 97.5 ± 3.5 and a mean pre-operative functional score of 21.7 ± 15.0 (SD) increased to 83.4 ± 12.4 at follow-up of seven years. Clear zones were common around the components at one month post-operatively but had completely disappeared after six months. An autopsy of a patient who underwent MG II TKA with HA-TCP two years previously, showed osteogenesis in all parts of the fibre-metal, and bone tissue comprised 77.7% of the interface. This coated
The aim of this study was to establish the diagnostic accuracy
of culture of joint aspirate with and without saline injection-reaspiration. This is a retrospective analysis of 580 hip and knee aspirations
in patients who were deemed to have a moderate to high risk of infection,
and who subsequently proceeded to revision arthroplasty over a period
of 12 years. It was carried out at a large quaternary referral centre
where preoperative aspiration is routine.Aims
Patients and Methods
The aim of this review was to evaluate the available literature
and to calculate the pooled sensitivity and specificity for the
different alpha-defensin test systems that may be used to diagnose
prosthetic joint infection (PJI). Studies using alpha-defensin or Synovasure (Zimmer Biomet, Warsaw,
Indiana) to diagnose PJI were identified from systematic searches
of electronic databases. The quality of the studies was evaluated
using the Quality Assessment of Studies of Diagnostic Accuracy (QUADAS)
tool. Meta-analysis was completed using a bivariate model.Aims
Materials and Methods
We studied the detection of joint replacements at airport security checks in relation to their weight, using two types of detector arch. A single-source, unilateral detector showed different sensitivities for implants on different sides of a test subject. All implants weighing more than 145 g were detected by one of the arches. The degree of detection was directly related to the logarithm of the weight of the
We performed a prospective study of 54 patients (76 knees) who underwent Osteonics series 3000 cruciate-retaining cementless total knee arthroplasty between December 1990 and June 1993. Five patients (seven knees) were lost to follow-up (90.7% completion). One patient required revision at 10.5 years after operation. The rate of survival was 100% at ten years and 96.7% at 13 years. The mean ten-year knee and function scores were 79 and 59 respectively. Both were significantly better than the pre-operative scores. The range of movement also improved. Although a radiolucent line around the tibial component enlarged in six knees (20.7%) at ten years, the clinical outcome was generally good. In a patient who died after 5.5 years, post-mortem examination of the knee showed no bony ingrowth into the tibial component. Despite poor bony ingrowth, press-fit fixation was satisfactory and good results can be obtained with this cementless, cruciate-retaining
We reviewed 80 patients (87 hips) who were older than 80 years of age at the time of cementless total hip arthroplasty. An Alloclassic SL stem had been implanted in all patients. A variety of cementless acetabular components was used. After a mean follow-up of 69.3 months (39.2 to 94.1) 48 hips in 43 patients were analysed clinically and radiologically. One patient had sustained a traumatic periprosthetic fracture of the femur with subsequent exchange of the stem 73 months after operation. Thirty-two patients (34 hips) had died and five patients (five hips) were unavailable for follow-up because of health reasons (four patients) or lack of co-operation (one patient). If the endpoint is defined as removal of the
Restoring the pre-morbid anatomy of the proximal humerus is a
goal of anatomical shoulder arthroplasty, but reliance is placed
on the surgeon’s experience and on anatomical estimations. The purpose
of this study was to present a novel method, ‘Statistical Shape
Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy
and calculates the 3D geometric parameters needed to restore normal
anatomy in patients with severe degenerative osteoarthritis or a
fracture of the proximal humerus. From a database of 57 humeral CT scans 3D humeral reconstructions
were manually created. The reconstructions were used to construct
a statistical shape model (SSM), which was then tested on a second
set of 52 scans. For each humerus in the second set, 3D reconstructions
of four diaphyseal segments of varying lengths were created. These
reconstructions were chosen to mimic severe osteoarthritis, a fracture
of the surgical neck of the humerus and a proximal humeral fracture
with diaphyseal extension. The SSM was then applied to the diaphyseal
segments to see how well it predicted proximal morphology, using
the actual proximal humeral morphology for comparison.Aims
Materials and Methods
Torsional instability of femoral components has not received much attention, and is difficult to detect in conventional radiographs. To test this we designed a system to apply a load in an anteroposterior direction to the head of a femoral component, implanted into a cadaveric femur. Rotation within the bone was measured, using a purpose built transducer, with and without preservation of the neck, with and without cement, and with longitudinal ridges but no cement. The results show that torsional instability may be a problem in uncemented replacement. Preservation of the femoral neck and the use of a ridged
We have reviewed 28 patients with reflex sympathetic dystrophy (RSD) who had 34 amputations in 31 limbs. The amputations had been performed for untenable pain (5), recurrent infection (14) or to improve residual function (15). Only two patients were relieved of pain by amputation, and this could not be predicted. Ten of 14 patients were cured of infection and 9 of 15 patients had improvement of residual function. In 28 of the amputations, RSD recurred in the stump, especially after amputation at a level which was not free from symptoms. Because of recurrence of RSD in the stump or severe hyperpathia only two patients wear a
We studied changes in patellar tendon length after reconstruction of the anterior cruciate ligament using either the medial third of the patellar tendon as a graft (n = 40) or a Leeds-Keio artificial ligament (n = 40). Both types of ligament replacement had been supplemented with a MacIntosh extra-articular lateral substitution. The mean change in length in the tendon graft group was 6% (SD 5.39); in the Leeds-Keio group it was 2.4% (SD 4.93). The change in length was significant in both groups, but shortening was more frequent and more severe in the tendon graft group. There was shortening of 10% or more in 25% of knees after patellar tendon graft and 7.5% after use of a Leeds-Keio
Ten patients underwent endoprosthetic replacement of the distal humerus for bone tumours over a period of 30 years. There were eight primary and two secondary tumours in four men and six women with a mean age of 47.5 years (15 to 76). The mean follow-up was eight years (9 months to 31 years). Four patients required further surgery, three having revision for aseptic loosening; two of these and one other later needing a rebushing. There were no cases of postoperative nerve palsy, infection, local recurrence or mechanical failure of the implant. Four patients died from their disease, all with the
We assessed 46 Syme’s amputees attending our prosthetic clinics in terms of the clinical and radiological condition of their stumps, their level of function and problems with the
We randomised 250 patients undergoing unilateral, elective hip arthroplasty for osteoarthritis to receive either a cemented or a non-cemented Mallory Head
α-defensin is a biomarker which has been described as having
a high degree of accuracy in the diagnosis of periprosthetic joint
infection (PJI). Current meta-analyses are based on the α-defensin
laboratory-based immunoassay rather than the quick on-table lateral
flow test kit. This study is the first meta-analysis to compare the
accuracy of the α-defensin laboratory-based immunoassay and the
lateral flow test kit for the diagnosis of PJI. A systematic review was performed according to the Preferred
Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
Inclusion criteria were all clinical studies where the diagnosis
of PJI was uncertain. All studies selected used the Musculoskeletal
Infection Society (MSIS) or modified MSIS criteria. Two independent
reviewers reviewed the studies and extracted data. A meta-analysis
of results was carried out: pooled sensitivity, specificity, positive
and negative likelihood ratio, heterogeneity and areas under curves
are reported.Aims
Materials and Methods
A series of 100 consecutive osteoarthritic patients was randomised to undergo total knee replacement using a Miller-Galante II