header advert
Results 1101 - 1120 of 1401
Results per page:
Bone & Joint Research
Vol. 3, Issue 2 | Pages 20 - 31
1 Feb 2014
Kiapour AM Murray MM

Injury to the anterior cruciate ligament (ACL) is one of the most devastating and frequent injuries of the knee. Surgical reconstruction is the current standard of care for treatment of ACL injuries in active patients. The widespread adoption of ACL reconstruction over primary repair was based on early perception of the limited healing capacity of the ACL. Although the majority of ACL reconstruction surgeries successfully restore gross joint stability, post-traumatic osteoarthritis is commonplace following these injuries, even with ACL reconstruction. The development of new techniques to limit the long-term clinical sequelae associated with ACL reconstruction has been the main focus of research over the past decades. The improved knowledge of healing, along with recent advances in tissue engineering and regenerative medicine, has resulted in the discovery of novel biologically augmented ACL-repair techniques that have satisfactory outcomes in preclinical studies. This instructional review provides a summary of the latest advances made in ACL repair.

Cite this article: Bone Joint Res 2014;3:20–31.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 147 - 156
1 Feb 2014
Rajpura A Kendoff D Board TN

We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual’s functional demands.

Cite this article: Bone Joint J 2014;96-B:147–56.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1575 - 1578
1 Dec 2009
Jaiswal PK Macmull S Bentley G Carrington RWJ Skinner JA Briggs TWR

Smoking is known to have an adverse effect on wound healing and musculoskeletal conditions. This case-controlled study looked at whether smoking has a deleterious effect in the outcome of autologous chondrocyte implantation for the treatment of full thickness chondral defects of the knee.

The mean Modified Cincinatti Knee score was statistically significantly lower in smokers (n = 48) than in non-smokers (n = 66) both before and after surgery (p < 0.05). Smokers experienced significantly less improvement in the knee score two years after surgery (p < 0.05). Graft failures were only seen in smokers (p = 0.016). There was a strong negative correlation between the number of cigarettes smoked and the outcome following surgery (Pearson’s correlation coefficient −0.65, p = 0.004).

These results suggest that patients who smoke have worse pre-operative function and obtain less benefit from this procedure than non-smokers. The counselling of patients undergoing autologous chondrocyte implantation should include smoking, not only as a general cardiopulmonary risk but also because poorer results can be expected in smokers following this procedure.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 153 - 158
1 Nov 2013
Victor J Premanathan A

We have investigated the benefits of patient specific instrument guides, applied to osteotomies around the knee. Single, dual and triple planar osteotomies were performed on tibias or femurs in 14 subjects. In all patients, a detailed pre-operative plan was prepared based upon full leg standing radiographic and CT scan information. The planned level of the osteotomy and open wedge resection was relayed to the surgery by virtue of a patient specific guide developed from the images. The mean deviation between the planned wedge angle and the executed wedge angle was 0° (-1 to 1, sd 0.71) in the coronal plane and 0.3° (-0.9 to 3, sd 1.14) in the sagittal plane. The mean deviation between the planned hip, knee, ankle angle (HKA) on full leg standing radiograph and the post-operative HKA was 0.3° (-1 to 2, sd 0.75). It is concluded that this is a feasible and valuable concept from the standpoint of pre-operative software based planning, surgical application and geometrical accuracy of outcome.

Cite this article: Bone Joint J 2013;95-B, Supple A:153–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 814 - 820
1 Jun 2008
Chu CR Izzo NJ Coyle CH Papas NE Logar A

We have studied the effects of bupivacaine on human and bovine articular chondrocytes in vitro. Time-lapse confocal microscopy of human articular chondrocytes showed > 95% cellular death after exposure to 0.5% bupivacaine for 30 minutes. Human and bovine chondrocytes exposed to 0.25% bupivacaine had a time-dependent reduction in viability, with longer exposure times resulting in higher cytotoxicity. Cellular death continued even after removal of 0.25% bupivacaine. After exposure to 0.25% bupivacaine for 15 minutes, flow cytometry showed bovine chondrocyte viability to be 41% of saline control after seven days. After exposure to 0.125% bupivacaine for up to 60 minutes, the viability of both bovine and human chondrocytes was similar to that of control groups.

These data show that prolonged exposure 0.5% and 0.25% bupivacaine solutions are potentially chondrotoxic.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 596 - 602
1 May 2012
Hansson G Nathorst-Westfelt J

In the majority of patients with slipped upper femoral epiphysis only one hip is involved at primary diagnosis. However, the contralateral hip often becomes involved over time. There are no reliable factors predicting a contralateral slip. Whether or not the contralateral hip should undergo prophylactic fixation is a matter of controversy. We present a number of essential points that have to be considered both when choosing to fix the contralateral hip prophylactically as well as when refraining from surgery and instead following the patients with repeat radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1236 - 1244
1 Sep 2006
Nishimori M Deie M Kanaya A Exham H Adachi N Ochi M

Bone marrow mesenchymal stromal cells were aspirated from immature male green fluorescent protein transgenic rats and cultured in a monolayer. Four weeks after the creation of the osteochondral defect, the rats were divided into three groups of 18: the control group, treated with an intra-articular injection of phosphate-buffered saline only; the drilling group, treated with an intra-articular injection of phosphate-buffered saline with a bone marrow-stimulating procedure; and the bone marrow mesenchymal stromal cells group, treated with an intra-articular injection of bone marrow mesenchymal stromal cells plus a bone marrow-stimulating procedure. The rats were then killed at 4, 8 and 12 weeks after treatment and examined.

The histological scores were significantly better in the bone marrow mesenchymal stromal cells group than in the control and drilling groups at all time points (p < 0.05). The fluorescence of the green fluorescent protein-positive cells could be observed in specimens four weeks after treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1457 - 1461
1 Nov 2008
Lee K Chung J Song E Seon J Bai L

We describe the surgical technique and results of arthroscopic subtalar release in 17 patients (17 feet) with painful subtalar stiffness following an intra-articular calcaneal fracture of Sanders’ type II or III. The mean duration from injury to arthroscopic release was 11.3 months (6.4 to 36) and the mean follow-up after release was 16.8 months (12 to 25). The patient was positioned laterally and three arthroscopic portals were placed anterolaterally, centrally and posterolaterally. The sinus tarsi and lateral gutter were debrided of fibrous tissue and the posterior talocalcaneal facet was released. In all, six patients were very satisfied, eight were satisfied and three were dissatisfied with their results. The mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from a mean of 49.4 points (35 to 66) pre-operatively to a mean of 79.6 points (51 to 95). All patients reported improvement in movement of the subtalar joint. No complications occurred following operation, but two patients subsequently required subtalar arthrodesis for continuing pain.

In the majority of patients a functional improvement in hindfoot function was obtained following arthroscopic release of the subtalar joint for stiffness and pain secondary to Sanders type II and III fractures of the calcaneum.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1676 - 1678
1 Dec 2011
Sadideen H Athanasou N Ashmore A McNab I

We report the case of an 82-year-old man who underwent fasciectomy for a severe Dupuytren’s contracture, during which an ossified lesion was encountered within the contracture and surrounding the neurovascular bundle. The abnormal tissue was removed with difficulty and heterotopic ossification was confirmed histologically. We believe this is the first report of heterotopic ossification in Dupuytren’s disease.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 2 - 8
1 Dec 2013
Jones R Wood D

This article provides an overview of the role of genomics in sarcomas and describes how new methods of analysis and comparative screening have provided the potential to progress understanding and treatment of sarcoma. This article reviews genomic techniques, the evolution of the use of genomics in cancer, the current state of genomic analysis, and also provides an overview of the medical, social and economic implications of recent genomic advances.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 793 - 800
1 Jun 2011
Yalçin N Öztürk A Özkan Y Çelimli N Özocak E Erdogan A Sahin N Ilgezdi S

We studied the effects of hyperbaric oxygen (HBO) and zoledronic acid (ZA) on posterior lumbar fusion using a validated animal model. A total of 40 New Zealand white rabbits underwent posterior lumbar fusion at L5–6 with autogenous iliac bone grafting. They were divided randomly into four groups as follows: group 1, control; group 2, HBO (2.4 atm for two hours daily); group 3, local ZA (20 μg of ZA mixed with bone graft); and group 4, combined HBO and local ZA. All the animals were killed six weeks after surgery and the fusion segments were subjected to radiological analysis, manual palpation, biomechanical testing and histological examination.

Five rabbits died within two weeks of operation. Thus, 35 rabbits (eight in group 1 and nine in groups 2, 3 and 4) completed the study. The rates of fusion in groups 3 and 4 (p = 0.015) were higher than in group 1 (p < 0.001) in terms of radiological analysis and in group 4 was higher than in group 1 with regard to manual palpation (p = 0.015). We found a statistically significant difference in the biomechanical analysis between groups 1 and 4 (p = 0.024). Histological examination also showed a statistically significant difference between groups 1 and 4 (p = 0.036).

Our results suggest that local ZA combined with HBO may improve the success rate in posterior lumbar spinal fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 257 - 261
1 Feb 2011
Rejholec M

In late developmental dysplasia of the hip in childhood, the deformed dysplastic acetabulum is malaligned and has lost its shape due to pressure from the subluxed femoral head. The outer part of the acetabulum involves the upper part of the original acetabulum, thereby giving a bipartite appearance. A clear edge separates the outer from inner part which represents the lower part of the original acetabulum and has no direct contact with the femoral head.

Combined pelvic osteotomy (CPO) using a Lance acetabuloplasty with either a Salter or a Pemberton procedure restores the original shape and realigns the acetabulum. A total of 20 children (22 hips), with a mean age of 46 months (28 to 94) at primary operation underwent CPO with follow-up for between 12 and 132 months.

In each case concentric stable reduction with good acetabular cover was achieved and maintained throughout the period of follow-up.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1348 - 1353
1 Oct 2013
Valenzuela GA Jacobson NA Buzas D Korecki TD Valenzuela RG Teitge RA

The outcome of high tibial osteotomy (HTO) deteriorates with time, and additional procedures may be required. The aim of this study was to compare the clinical and radiological outcomes between unicompartmental knee replacement (UKR) and total knee replacement (TKR) after HTO as well as after primary UKR. A total of 63 patients (63 knees) were studied retrospectively and divided into three groups: UKR after HTO (group A; n = 22), TKR after HTO (group B; n = 18) and primary UKR (group C; n = 22). The Oxford knee score (OKS), Knee Society score (KSS), hip–knee–ankle angles, mechanical axis and patellar height were evaluated pre- and post-operatively. At a mean of 64 months (19 to 180) post-operatively the mean OKS was 43.8 (33 to 49), 43.3 (30 to 48) and 42.5 (29 to 48) for groups A, B and C, respectively (p = 0.73). The mean KSS knee score was 88.8 (54 to 100), 88.11 (51 to 100) and 85.3 (45 to 100) for groups A, B and C, respectively (p = 0.65), and the mean KSS function score was 85.0 (50 to 100) in group A, 85.8 (20 to 100) in group B and 79.3 (50 to 100) in group C (p = 0.48). Radiologically the results were comparable for all groups except for patellar height, with a higher incidence of patella infra following a previous HTO (p = 0.02).

Cite this article: Bone Joint J 2013;95-B:1348–53.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 998 - 1006
1 Jul 2012
Kodama A Kamei N Kamei G Kongcharoensombat W Ohkawa S Nakabayashi A Ochi M

For the treatment of ununited fractures, we developed a system of delivering magnetic labelled mesenchymal stromal cells (MSCs) using an extracorporeal magnetic device. In this study, we transplanted ferucarbotran-labelled and luciferase-positive bone marrow-derived MSCs into a non-healing femoral fracture rat model in the presence of a magnetic field. The biological fate of the transplanted MSCs was observed using luciferase-based bioluminescence imaging and we found that the number of MSC derived photons increased from day one to day three and thereafter decreased over time. The magnetic cell delivery system induced the accumulation of photons at the fracture site, while also retaining higher photon intensity from day three to week four. Furthermore, radiological and histological findings suggested improved callus formation and endochondral ossification. We therefore believe that this delivery system may be a promising option for bone regeneration.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1544 - 1550
1 Nov 2013
Uchiyama S Itsubo T Nakamura K Fujinaga Y Sato N Imaeda T Kadoya M Kato H

This multicentre prospective clinical trial aimed to determine whether early administration of alendronate (ALN) delays fracture healing after surgical treatment of fractures of the distal radius. The study population comprised 80 patients (four men and 76 women) with a mean age of 70 years (52 to 86) with acute fragility fractures of the distal radius requiring open reduction and internal fixation with a volar locking plate and screws. Two groups of 40 patients each were randomly allocated either to receive once weekly oral ALN administration (35 mg) within a few days after surgery and continued for six months, or oral ALN administration delayed until four months after surgery. Postero-anterior and lateral radiographs of the affected wrist were taken monthly for six months after surgery. No differences between groups was observed with regard to gender (p = 1.0), age (p = 0.916), fracture classification (p = 0.274) or bone mineral density measured at the spine (p = 0.714). The radiographs were assessed by three independent assessors. There were no significant differences in the mean time to complete cortical bridging observed between the ALN group (3.5 months (se 0.16)) and the no-ALN group (3.1 months (se 0.15)) (p = 0.068). All the fractures healed in the both groups by the last follow-up. Improvement of the Quick-Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, grip strength, wrist range of movement, and tenderness over the fracture site did not differ between the groups over the six-month period. Based on our results, early administration of ALN after surgery for distal radius fracture did not appear to delay fracture healing times either radiologically or clinically.

Cite this article: Bone Joint J 2013;95-B:1544–50.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 22 - 24
1 Aug 2013

The August 2013 Trauma Roundup360 looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in tibial plateau fractures; it’s all about the radius of curvature; radius of curvature revisited; radial head replacement in complex elbow reconstruction; stem cells in early fracture haematoma; heterotrophic ossification in forearms; and Boston in perspective.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 650 - 657
1 May 2011
Hasegawa K Shimoda H Kitahara K Sasaki K Homma T

We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone > 2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped.

Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 326 - 331
1 Mar 2011
Javed A O’Donnell JM

We reviewed the clinical outcome of arthroscopic femoral osteochondroplasty for cam femoroacetabular impingement performed between August 2005 and March 2009 in a series of 40 patients over 60 years of age. The group comprised 26 men and 14 women with a mean age of 65 years (60 to 82). The mean follow-up was 30 months (12 to 54).

The mean modified Harris hip score improved by 19.2 points (95% confidence interval 13.6 to 24.9; p < 0.001) while the mean non-arthritic hip score improved by 15.0 points (95% confidence interval 10.9 to 19.1, p < 0.001). Seven patients underwent total hip replacement after a mean interval of 12 months (6 to 24 months) at a mean age of 63 years (60 to 70). The overall level of satisfaction was high with most patients indicating that they would undergo similar surgery in the future to the contralateral hip, if indicated. No serious complications occurred.

Arthroscopic femoral osteochondroplasty performed in selected patients over 60 years of age, who have hip pain and mechanical symptoms resulting from cam femoroacetabular impingement, is beneficial with a minimal risk of complications at a mean follow-up of 30 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 630 - 637
1 May 2012
Bourke HE Gordon DJ Salmon LJ Waller A Linklater J Pinczewski LA

The purpose of this study was to report the outcome of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with ‘isolated’ ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time.

ACL reconstructive surgery in patients with an ‘isolated’ rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 851 - 854
1 Jun 2013
Madhuri V Arora SK Dutt V

Slipped capital femoral epiphysis (SCFE) is uncommon in India and we routinely look for associated metabolic or endocrine abnormalities. In this study we investigated a possible association between vitamin D deficiency and SCFE. All children presenting with SCFE during the study period had their 25-hydroxyvitamin D levels measured as part of an overall metabolic, renal and endocrine status evaluation, which included measurement of body mass index (BMI). Vitamin D status was compared with age-, gender- and habitat-matched controls with acute trauma or sepsis presenting to our emergency department.

A total of 15 children (12 boys and three girls) with a mean age of 13 years (sd 1.81; 10 to 16) presented for treatment for SCFE during a two-year period beginning in January 2010. Renal and thyroid function was within the normal range in all cases. The mean BMI was 24.9 kg/m2 (17.0 to 33.8), which was significantly higher than that of the controls (p = 0.006). There was a statistically significant difference between the mean values of 25-hydroxyvitamin D in the children with SCFE and the controls (11.78 ng/ml (sd 5.4) versus 27.06 ng/ml (sd 5.53), respectively; p < 0.001). We concluded that, along with high BMI, there is a significant association of vitamin D deficiency and SCFE in India.

Cite this article: Bone Joint J 2013;95-B:851–4.