Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.
The radiological evaluation of the anterolateral femoral head is an essential tool for the assessment of the cam type of femoroacetabular impingement. CT, MRI and frog lateral plain radiographs have all been suggested as imaging options for this type of lesion. The alpha angle is accepted as a reliable indicator of the cam type of impingement and may also be used as an assessment for the successful operative correction of the cam lesion. We studied the alpha angles of 32 consecutive patients with femoroacetabular impingement. The angle measured on frog lateral radiographs using templating tools was compared with that measured on CT scans in order to assess the reliability of the frog lateral view in analysing the alpha angle in cam impingement. A high interobserver reliability was noted for the assessment of the alpha angle on the frog lateral view with an intraclass correlation coefficient of 0.83. The mean alpha angle measured on the frog lateral view was 58.71° (32° to 83.3°) and that by CT was 65.11° (30° to 102°). A poor intraclass correlation coefficient (0.08) was noted between the measurements using the two systems. The frog lateral plain radiograph is not reliable for measuring the alpha angle. Various factors may be responsible for this such as the projection of the radiograph, the positioning of the patient and the quality of the image. CT may be necessary for accurate measurement of the alpha angle.
The technical advances in arthroscopic surgery
of the hip, including the improved ability to manage the capsule
and gain extensile exposure, have been paralleled by a growth in
the number of conditions that can be addressed. This expanding list
includes symptomatic labral tears, chondral lesions, injuries of
the ligamentum teres, femoroacetabular impingement (FAI), capsular
laxity and instability, and various extra-articular disorders, including snapping
hip syndromes. With a careful diagnostic evaluation and technical
execution of well-indicated procedures, arthroscopic surgery of
the hip can achieve successful clinical outcomes, with predictable
improvements in function and pre-injury levels of physical activity
for many patients. This paper reviews the current position in relation to the use
of arthroscopy in the treatment of disorders of the hip. Cite this article:
There remains a lack of data on the reliability of methods to
estimate tibial coverage achieved during total knee replacement.
In order to address this gap, the intra- and interobserver reliability
of a three-dimensional (3D) digital templating method was assessed
with one symmetric and one asymmetric prosthesis design. A total of 120 template procedures were performed according to
specific rotational and over-hang criteria by three observers at
time zero and again two weeks later. Total and sub-region coverage
were calculated and the reliability of the templating and measurement
method was evaluated.Objectives
Methods
Obtaining a balanced flexion gap with correct
femoral component rotation is one of the prerequisites for a successful
outcome after total knee replacement (TKR). Different techniques
for achieving this have been described. In this study we prospectively
compared gap-balancing Both groups systematically reproduced a similar external rotation
of the femoral component relative to the surgical transepicondylar
axis: 2.4°
Deficiencies of acetabular bone stock at revision hip replacement were reconstructed with two different types of allograft using impaction bone grafting and a Burch-Schneider reinforcement ring. We compared a standard frozen non-irradiated bone bank allograft (group A) with a freeze-dried irradiated bone allograft, vitalised with autologous marrow (group B). We studied 78 patients (79 hips), of whom 87% (69 hips) had type III acetabular defects according to the American Academy of Orthopaedic Surgeons classification at a mean of 31.4 months (14 to 51) after surgery. At the latest follow-up, the mean Harris hip score was 69.9 points (13.5 to 97.1) in group A and 71.0 points (11.5 to 96.5) in group B. Each hip showed evidence of trabeculation and incorporation of the allograft with no acetabular loosening. These results suggest that the use of an acetabular reinforcement ring and a living composite of sterile allograft and autologous marrow appears to be a method of reconstructing acetabular deficiencies which gives comparable results to current forms of treatment.
The April 2012 Oncology Roundup360 looks at chondrosarcoma of the cervical spine, if excision margins matter, radiation-induced sarcomas, giant cell tumours and bone cement, enchondromatosis and malignant change, axial or appendicular Ewing’s sarcoma, and diagnosing a sarcoma
Deformity after slipped upper femoral epiphysis
(SUFE) can cause cam-type femoroacetabular impingement (FAI) and
subsequent osteoarthritis (OA). However, there is little information
regarding the radiological assessment and clinical consequences
at long-term follow-up. We reviewed 36 patients (43 hips) previously
treated by We conclude that persistent deformity with radiological cam FAI
after SUFE is associated with poorer clinical and radiological long-term
outcome. Although the radiological measurements had quite wide limits
of agreement, they are useful for the diagnosis of post-slip deformities
in clinical practice.
There are no recent studies comparing cable with
wire for the fixation of osteotomies or fractures in total hip replacement
(THR). Our objective was to evaluate the five-year clinical and
radiological outcomes and complication rates of the two techniques.
We undertook a review including all primary and revision THRs performed
in one hospital between 1996 and 2005 using cable or wire fixation.
Clinical and radiological evaluation was performed five years post-operatively.
Cables were used in 51 THRs and wires in 126, and of these, 36 THRs
with cable (71%) and 101 with wire (80%) were evaluated at follow-up.
The five-year radiographs available for 33 cable and 91 wire THRs
revealed rates of breakage of fixation of 12 of 33 (36%) and 42
of 91 (46%), respectively. With cable there was a significantly
higher risk of metal debris (68% In conclusion, we found a higher incidence of complications and
a trend towards increased infection and foreign-body reaction with
the use of cables.
Numerous complications following total knee replacement (TKR)
relate to the patellofemoral (PF) joint, including pain and patellar
maltracking, yet the options for A total of three knees with end-stage osteoarthritis and three
knees that had undergone TKR at more than one year’s follow-up were
investigated. In each knee, sequential biplane radiological images
were acquired from the sagittal direction (i.e. horizontal X-ray
source and 10° below horizontal) for a sequence of eight flexion
angles. Three-dimensional implant or bone models were matched to
the biplane images to compute the six degrees of freedom of PF tracking
and TF kinematics, and other clinical measures.Objectives
Methods
The early designs of hip resurfacing implants suffered high rates of early failure, making it impossible to obtain valuable mid-term radiostereophotogrammetric (RSA) results. The metal-on-metal Birmingham Hip Resurfacing arthroplasty has shown promising mid-term results and we present here the first mid-term RSA analysis of a hip resurfacing implant. The analysis was performed in 19 hips at five years post-operatively. The mean acetabular component translation and rotation, and femoral component translation were compared with the previous RSA measurements at two and six months, and one and two years. There was no statistical significance (
We reviewed 124 patients with a conventional pelvic chondrosarcoma who had been treated over a period of 20 years. We recorded the type of tumour (central or peripheral), type of operation (limb salvage surgery or hemipelvectomy), the grade of tumour, local recurrence and/or metastases, in order to identify the factors which might influence survival. More satisfactory surgical margins were achieved for central tumours or in those patients treated by hemipelvectomy. However, grade 1 tumours, whatever the course, did not develope metastases or cause death, while grade 3 tumours had the worst outcome and prognosis. Central, high-grade tumours require aggressive surgical treatment in order to achieve adequate surgical margins, particularly in those lesions located close to the sacroiliac joint. By contrast, grade 1 peripheral chondrosarcomas may be treated with contaminated margins in order to reduce operative morbidity, but without reducing survival.
The April 2012 Trauma Roundup360 looks at fibula-pro-tibia plating, galeazzi fractures, distal radial fractures in the over 65s, transverse sacral fractures, acute dislocation of the knee, posterior malleolar fractures, immobilising the broken scaphoid, the terrible triad, lower limb amputation after trauma, and whiplash injuries
Although equinus gait is the most common abnormality
in children with spastic cerebral palsy (CP) there is no consistency
in recommendations for treatment, and evidence for best practice
is lacking. The Baumann procedure allows selective fractional lengthening
of the gastrocnemii and soleus muscles but the long-term outcome
is not known. We followed a group of 18 children (21 limbs) with
diplegic CP for ten years using three-dimensional instrumented gait
analysis. The kinematic parameters of the ankle joint improved significantly
following this procedure and were maintained until the end of follow-up.
We observed a normalisation of the timing of the key kinematic and
kinetic parameters, and an increase in the maximum generation of
power of the ankle. There was a low rate of overcorrection (9.5%,
n = 2), and a rate of recurrent equinus similar to that found with
other techniques (23.8%, n = 5). As the procedure does not impair the muscle architecture, and
allows for selective correction of the contracted gastrocnemii and
soleus, it may be recommended as the preferred method for correction
of a mild fixed equinus deformity.
Incomplete avulsion of the proximal hamstrings
can be a severely debilitating injury that causes weakness, pain
while sitting and inability to run. The results of the surgical treatment
of 23 consecutive patients with such injuries at least two years
after surgery are described. The surgery consisted of the repair
of the hamstrings directly onto the ischial tuberosity. At review,
using a visual analogue scale (VAS, 0 to 100), pain while sitting improved
from a mean of 40 (0 to 100) to 64 (0 to 100) (p = 0.024), weakness
from a mean of 39 (0 to 90) to 76 (7 to 100) (p = 0.0001) and the
ability to run from a mean of 24 (0 to 88) to 64 (0 to 95) (p =
0.0001). According to a VAS, satisfaction was rated at a mean of
81 (0 to 100) and 20 patients (87%) would have the same procedure
again. Hamstring strength measured pre- and post-operatively had
improved significantly from a mean of 64% (0% to 95%) to 88% (50%
to 114%) compared with the normal side. Most of these patients with symptomatic incomplete hamstring
avulsions unresponsive to conservative treatment had an improved
outcome after surgical repair.
We report the management of an adult patient with septic sacroiliitis. This is an uncommon condition. Debridement, decompression and spontaneous fusion are the treatment of choice when symptoms do not resolve with routine initial intravenous antibiotic therapy. A percutaneous technique is described, using the principles of sacroiliac screw insertion commonly used for pelvic reconstruction surgery. After successful evacuation of the infected joint, fusion was observed in our patient.
In developmental dysplasia of the hip, a deficient acetabulum may be augmented by placing local autogenous iliac osseous graft, or the ilium itself, over the head of the femur with the expectation that the added bone will function as a bearing surface. We analysed this bone obtained
We present our early experience of arthroscopic
reduction of the dislocated hip in very young infants with developmental
dysplasia of the hip (DDH). Eight dislocated hips, which had failed attempts at closed reduction,
were treated by arthroscopy of the hip in five children with a mean
age of 5.8 months (4 to 7). A two-portal technique was used, with
a medial sub-adductor portal for a 2.7 mm cannulated system with
a 70° arthroscope and an anterolateral portal for the instruments. Following
evaluation of the key intra-articular structures, the hypertrophic
ligamentum teres and acetabular pulvinar were resected, and a limited
release of the capsule was performed prior to reduction of the hip.
All hips were reduced by a single arthroscopic procedure, the reduction
being confirmed on MRI scan. None of the hips had an inverted labrum.
The greatest obstacle to reduction was a constriction of the capsule.
At a mean follow-up of 13.2 months (9 to 24), all eight hips remained
stable. Three developed avascular necrosis. The mean acetabular index
decreased from 35.5° (30° to 40°) pre-operatively to 23.3° (17°
to 28°). This study demonstrates that arthroscopic reduction is feasible
using two standardised portals. Longer follow-up studies are necessary
to evaluate the functional results.
We describe a case of lumbosacral plexopathy caused by an isolated aneurysm of the common iliac artery. The patient presented with worsening low back pain, progressive numbness and weakness of the right leg in the L2-L4 distribution. This had previously been diagnosed as sciatica. A CT scan showed an aneurysm of the right common iliac artery which measured 8 cm in diameter. Despite being listed for emergency endovascular stenting, the aneurysm ruptured and the patient died. It is important to distinguish a lumbosacral plexopathy from sciatica and to bear in mind its treatable causes which include aneurysms of the common and internal iliac arteries.
The Birmingham hip resurfacing metal-on-metal arthroplasty was introduced in 1997 and has shown promising short- to mid-term results. We used radiostereophotogrammetric analysis (RSA) to study the stability of 20 resurfacing arthroplasties over a follow-up period of 24 months. Radiological examinations for RSA were performed immediately after surgery and at two, six, 12 and 24 months after operation. Precision and detection of migration thresholds (non-zero movement) were calculated. All the results corresponded well to those found in similar experimental arrangements with standard hip prostheses. Migration of the cup and vertical and mediolateral migration of the head were calculated. The values were low at two years compared with those of earlier studies of cemented femoral components in conventional total hip replacements indicating that there was no evidence of excessive early migration or loosening of the components.