Advertisement for orthosearch.org.uk
Results 1061 - 1080 of 1872
Results per page:

Objectives

Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA.

Methods

We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 288 - 292
1 Mar 1990
Pozo J Powell B Andrews B Hutton P Clarke J

We reviewed 35 patients who had an amputation following the failure of treatment for severe lower limb trauma. Seven of the amputations were for ischaemia, within one month of injury; 13 were between one month and one year for infection complicating loss of wound cover in un-united fractures; and 15 were later than one year after injury, mainly for infected non-union. The latter group of patients had had an average of 12 operations and 50 months of treatment, including eight months in hospital. We used a new limb injury score based on damage to the individual tissue elements; this indicated that, even in the absence of neurovascular injury, the presence of severe damage to skin, bone and muscle, with wound contamination, particularly in the lower tibia, had a poor prognosis. We therefore recommend, to avoid multiple operations, with prolonged hospitalisation and suffering, that these patients should have early independent review by orthopaedic and plastic surgeons with the aim of establishing an accurate prognosis for the salvage of a useful limb


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 664 - 669
1 Aug 1987
Taylor J Warrell E Evans R

The parameters of cellular proliferation and growth in the growth plates of immature rats were measured after unilateral tibial osteotomy and used to calculate growth rates. Distal osteotomy of one tibia was followed by a bilateral increase in the calculated growth rate of the distal growth plates. However, the ipsilateral distal growth plate grew faster than the contralateral between 12 and 18 days after operation, which appeared to be related to increased cell proliferation and height. Proximal osteotomy led to an increase in growth rates proximally which was more marked on the contralateral side. The lesser response of the ipsilateral growth plate may have been due to local impairment of blood supply, or to greater local release of metabolites after bony damage. Distal tibial osteotomy gave similar results to circumferential release of the distal tibial periosteum. Proximal osteotomy, however, produced a relative impairment of growth on the operated side. This may be of importance in the correction of childhood deformities associated with inequality of leg length


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 463 - 469
1 May 1985
Law H Annan I McCarthy I Hughes S Stead A Camburn M Montgomery H

We have investigated the effect of currents induced by electromagnetic fields on the healing of the tibia of sheep after osteotomy, using objective and quantifiable criteria wherever possible. A battery-powered, induction apparatus was developed and was enclosed within the cast applied to the limb, so that the treated fractures received pulsed magnetic fields for 24 hours a day while the animals were freely mobile. In all, 13 sheep were treated and 13 were used as controls. The response was assessed by radiography of the limb and of the excised bone, by histology, including measurement of the areas of callus, fibrocallus and cortical bone, and by measurement of the uptake and extraction of bone-seeking mineral. All the bones healed and no statistically significant differences between the treated animals and the controls were discovered except (at only P less than 0.05) in the uptake of bone-seeking mineral; this increased more rapidly in treated animals over the two to three weeks after osteotomy, although at six weeks the uptake in both groups was the same


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 232 - 236
1 Mar 1985
Upadhyay S Moulton A Burwell R

The factors involved in the mechanism leading to traumatic posterior dislocation of the hip are examined. In 47 adult patients who had previously suffered such a dislocation, ultrasound scans were used to measure femoral anteversion on both the affected and the uninjured side. In 36 normal adult volunteers, used as controls, similar measurements were made. Femoral anteversion on both the injured and uninjured side was significantly reduced in the patients compared with the volunteers. These findings are discussed in the light of previous work which indicates that medial rotation is a factor in the mechanism of posterior dislocation of the hip. It is suggested that reduced anteversion acts like medial rotation to make the hip more susceptible to posterior dislocation, and that the less the anteversion the more likely is the injury to be a dislocation rather than a fracture-dislocation. It is concluded that patients who suffer such dislocated hips belong at one extreme of the normal population, having either reduced femoral anteversion or even retroversion, and that this anatomical feature selects towards hip dislocation rather than to injury of the femoral shaft, knee or tibia during the appropriate type of accident


Bone & Joint Research
Vol. 6, Issue 11 | Pages 631 - 639
1 Nov 2017
Blyth MJG Anthony I Rowe P Banger MS MacLean A Jones B

Objectives

This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.

Methods

A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 705 - 709
1 Jul 1999
Hara T Hayashi K Nakashima Y Kanemaru T Iwamoto Y

We have studied the effect of hydroxyapatite (HA) coating in 15 ovariectomised and 15 normal rats which had had a sham procedure. Twenty-four weeks after operation, HA-coated implants were inserted into the intramedullary canal of the right femur and uncoated implants into the left femur. The prostheses were removed four weeks after implantation. Twelve specimens in each group had mechanical push-out tests. Sagittal sections of the other three were evaluated by SEM. The bone mineral density (BMD) of the dissected left tibia was measured by dual-energy x-ray absorptiometry. The difference in BMD between the control and ovariectomised tibiae was 35.01 mg/cm. 2. (95% CI, 26.60 to 43.42). The push-out strength of the HA-coated implants was higher than that of the uncoated implants in both groups (p < 0.0001), but the HA-coated implants of the ovariectomised group had a reduction in push-out strength of 40.3% compared with the control group (p < 0.0001). Our findings suggest that HA-coated implants may improve the fixation of a cementless total hip prosthesis but that the presence of osteoporosis may limit the magnitude of this benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 450 - 455
1 May 1995
Christie J Robinson C Pell A McBirnie J Burnett R

We performed transoesophageal echocardiography in 111 operations (110 patients) which included medullary reaming for fresh fractures of the femur and tibia, pathological lesions of the femur, and hemiarthroplasty of the hip. Embolic events of varying intensity were seen in 97 procedures and measured pulmonary responses correlated with the severity of embolic phenomena. Twenty-four out of the 25 severe embolic responses occurred while reaming pathological lesions or during cemented hemiarthroplasty of the hip and, overall, pathological lesions produced the most severe responses. Paradoxical embolisation occurred in four patients, all with pathological lesions of the femur (21%); two died. In 12 patients large coagulative masses became trapped in the heart. Extensive pulmonary thromboembolism with reamed bone and immature clot was found at post-mortem in two patients; there was severe systemic embolisation of fat and marrow in one who had a patent foramen ovale and widespread mild systemic fat embolisation in the other without associated foraminal defect. Sequential analysis of blood from the right atrium in five patients showed considerable activation of clotting cascades during reaming


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 213 - 218
1 Mar 1995
Maruyama M

A clay containing hydroxyapatite (HA) was developed for use as a filling material between an uncemented implant and bone. It consists of 55% HA granules greater than 0.1 mm in size with a homogeneous pore distribution and a porosity of 35% to 48% in a saline solution of sodium alginate (6%). Ti-6A1-4V alloy rods with smooth surfaces were implanted into the distal medullary canal of one osteotomised tibia of 32 Japanese white rabbits. Sixteen rods were inserted with HA clay and 16 without the clay to act as a control group. Six of each group were killed at one week and ten at 12 weeks postoperatively. The pull-out strength of the implants with HA clay was significantly greater at 12 weeks (p < 0.05), as was the percentage of the area of the new bone (p < 0.05). The study suggests that HA clay has an osteoconductive property, allowing adequate bone fixation across a gap at an early stage. The use of HA clay to enhance the early stability of uncemented components may help to improve the functional outcome of total joint arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 41 - 48
1 Jan 1993
O'Connor J

A computer-based model of the knee was used to study forces in the cruciate ligaments induced by co-contraction of the extensor and flexor muscles, in the absence of external loads. Ligament forces are required whenever the components of the muscle forces parallel to the tibial plateau do not balance. When the extending effect of quadriceps exactly balances the flexing effect of hamstrings, the horizontal components of the two muscle forces also balance only at the critical flexion angle of 22 degrees. The calculations show that co-contraction of the quadriceps and hamstring muscles loads the anterior cruciate ligament from full extension to 22 degrees of flexion and loads the posterior cruciate at higher flexion angles. In these two regions of flexion, the forward pull of the patellar tendon on the tibia is, respectively, greater than or less than the backward pull of hamstrings. Simultaneous quadriceps and gastrocnemius contraction loads the anterior cruciate over the entire flexion range. Simultaneous contraction of all three muscle groups can unload the cruciate ligaments entirely at flexion angles above 22 degrees. These results may help the design of rational regimes of rehabilitation after ligament injury or repair


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1596 - 1602
1 Dec 2017
Dunbar MJ Laende EK Collopy D Richardson CG

Aims

Hydroxyapatite coatings for uncemented fixation in total knee arthroplasty can theoretically provide a long-lasting biological interface with the host bone. The objective of this study was to test this hypothesis with propriety hydroxyapatite, peri-apatite, coated tibial components using component migration measured with radiostereometric analysis over two years as an indicator of long-term fixation.

Patients and Methods

A total of 29 patients at two centres received uncemented PA-coated tibial components and were followed for two years with radiostereometric analysis exams to quantify the migration of the component.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 227 - 232
1 Mar 1984
Lang-Stevenson A Sharrard W

The results and complications of the use of Bailey-Dubow extensible rods in 28 lower limb bones of 10 patients suffering from osteogenesis imperfecta are reviewed. Twenty-eight operations were for the primary insertion of the rods into the femur or tibia; a further nine operations were needed for the treatment of complications. These complications included 10 instances of proximal migration of the distal end of the rod, one of incorrect placement in the proximal femur, four instances of loosening of a T-piece and three of infection about a rod, two of these being in one child. Most complications arose from technical faults at insertion. The details of technique which have evolved from experience are described. Only one fracture has occurred in a bone after correct placement of a rod. Of the 10 patients, seven of whom had never walked before, seven were able to walk and two others had achieved walking, but were under treatment for complications at the time of review. There was no evidence of damage to growth epiphyses. The greater technical complexity of insertion of Bailey-Dubow rods is well justified by the results obtained when they are correctly applied


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 350 - 354
1 May 1983
Connor J Horan F Beighton P

The clinical features of nine new patients with dysplasia epiphysialis hemimelica are reported, with a long-term follow-up on a further seven patients who were described in the earliest case reports of this disease. Each of these 16 patients had only one leg involved, but 12 had multiple epiphyses affected. The distal femur, distal tibia and talus were the commonest sites and most patients presented with painless swelling or deformity. Wasting of the muscles of the affected leg was a common finding, and was occasionally disproportionate to the degree of disuse. One patient had the unique combination of involvement of the lateral and medial halves of different epiphyses in the same limb and another had unusual metaphysial changes. Diagnosis was often delayed despite typical radiographic appearances. There was no evidence for a genetic component in the aetiology nor was any common environmental factor identified. Treatment by local excision was generally effective for lesions in the vicinity of the knee, but some patients with involvement of the talus required arthrodesis around the ankle. The long-term prognosis appears to be good and so far only two of these patients have developed premature osteoarthritis


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1237 - 1243
1 Sep 2017
Emori M Kaya M Irifune H Takahashi N Shimizu J Mizushima E Murahashi Y Yamashita T

Aims

The aims of this study were to analyse the long-term outcome of vascularised fibular graft (VFG) reconstruction after tumour resection and to evaluate the usefulness of the method.

Patients and Methods

We retrospectively reviewed 49 patients who had undergone resection of a sarcoma and reconstruction using a VFG between 1988 and 2015. Their mean follow-up was 98 months (5 to 317). Reconstruction was with an osteochondral graft (n = 13), intercalary graft (n = 12), inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed the oncological and functional outcome, and the rate of bony union and complications.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 378 - 386
1 Mar 2018
Campanacci DA Totti F Puccini S Beltrami G Scoccianti G Delcroix L Innocenti M Capanna R

Aims

After intercalary resection of a bone tumour from the femur, reconstruction with a vascularized fibular graft (VFG) and massive allograft is considered a reliable method of treatment. However, little is known about the long-term outcome of this procedure. The aims of this study were to determine whether the morbidity of this procedure was comparable to that of other reconstructive techniques, if it was possible to achieve a satisfactory functional result, and whether biological reconstruction with a VFG and massive allograft could achieve a durable, long-lasting reconstruction.

Patients and Methods

A total of 23 patients with a mean age of 16 years (five to 40) who had undergone resection of an intercalary bone tumour of the femur and reconstruction with a VFG and allograft were reviewed clinically and radiologically. The mean follow-up was 141 months (24 to 313). The mean length of the fibular graft was 18 cm (12 to 29). Full weight-bearing without a brace was allowed after a mean of 13 months (seven to 26).


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 236 - 241
1 Mar 1995
Kim Y Oh J Oh S

We report the incidence of osteolysis in the femur, tibia, and patella of 44 consecutive patients (60 knees) who were followed for more than seven years after cementless knee arthroplasty with a Porous-Coated Anatomic prosthesis. The average age of the patients was 56.5 years (17 to 73); the operative diagnosis was osteoarthritis (33 knees), rheumatoid arthritis (17), tuberculous arthritis (7) and post-traumatic arthritis (3). All patellae were resurfaced. No femoral or tibial component was loose at the final follow-up examination. Thirty patellar components were loose of which six had been revised. Radiographs revealed osteolysis in 90% of the tibial plateaux and in 80% of the 30 intact patellar prostheses. No osteolysis was seen around any femoral component. In 50 knees (83%) the average wear of the polyethylene liner was 2.5 mm in the medial compartment and 1.7 mm in the lateral compartment. Four of 60 knees (6.7%) were revised for complete wear of the polyethylene liner of the tibial component. Fixation of the tibial and patellar components without cement fails to seal the interface between bone and prosthesis and allows the migration of polyethylene particulate debris which causes osteolysis


Bone & Joint Research
Vol. 7, Issue 8 | Pages 524 - 538
1 Aug 2018
Zhao S Arnold M Ma S Abel RL Cobb JP Hansen U Boughton O

Objectives

The ability to determine human bone stiffness is of clinical relevance in many fields, including bone quality assessment and orthopaedic prosthesis design. Stiffness can be measured using compression testing, an experimental technique commonly used to test bone specimens in vitro. This systematic review aims to determine how best to perform compression testing of human bone.

Methods

A keyword search of all English language articles up until December 2017 of compression testing of bone was undertaken in Medline, Embase, PubMed, and Scopus databases. Studies using bulk tissue, animal tissue, whole bone, or testing techniques other than compression testing were excluded.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 945 - 952
1 Jul 2018
Malhotra K Chan O Cullen S Welck M Goldberg AJ Cullen N Singh D

Aims

Gastrocnemius tightness predisposes to musculoskeletal pathology and may require surgical treatment. However, it is not clear what proportion of patients with foot and ankle pathology have clinically significant gastrocnemius tightness. The aim of this study was to compare the prevalence and degree of gastrocnemius tightness in a control group of patients with a group of patients with foot and ankle pathology.

Patients and Methods

This prospective, case-matched, observational study compared gastrocnemius tightness, as assessed by the lunge test, in a control group and a group with foot and ankle pathology. Gastrocnemius tightness was calculated as the difference in dorsiflexion of the ankle with the knee extended and flexed.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 458 - 464
1 Nov 1977
von der Mark K von der Mark H

The role of three genetically distinct collagen types in the formation of endochondral bone and in calcification and resorption of cartilage has been assessed. Using antibodies specific to types I, II and III collagen we have demonstrated in the embryonic chick tibia that endochondral bone formation began with deposition of type III collagen in lacunae of hypertropic chondrocytes by invading bone-marrow-derived cells. This was followed by the deposition of type I collagen, which is the collagenous constituent of endochondral osteoid. At later stages of development endochondral osteoid was found in the epiphysial growth plate in apparently intact lacunae of hypertrophic chondrocytes; this indicated that the latter might contribute to the synthesis of osteoid type I collagen. Immuno-histological staining for collagen types, and von Kossa staining for calcium phosphate on parallel sections, demonstrated that type I and type II collagen matrices were substrates for calcification. Endochondral bone (with type I collagen) was found on scaffolding of both uncalcified and calcified cartilage (with type II collagen), indicating that calcification of endochondral osteoid and of the underlying cartilage occurred independentyl. Spicules of endochondral cancellous bone of a four-week-old chick contained a core of calcified type II collagen


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 197 - 203
1 May 1975
Tachakra SS Sevitt S

Serial arterial blood-gas analyses showed a phase of primary hypoxaemia in thirty-two out of fifty fracture patients (64 per cent) without head, chest or abdominal injury. The incidence was greater in those with shaft fractures of the femur or tibia or both, than in those with fractured hips, and was related to the severity of injury and the nature of the accident. Most affected subjects were already hypoxaemic on admission to hospital: the arterial PO. 2. commonly fell to between 60 and 70 millimetres of mercury, and the episode generally lasted a few days. The hypoxaemia was generally subclinical but four patients developed mild clinical fat embolism. Early hypoxaemia was not found in six patients admitted with only soft-tissue injuries. One or more subsequent attacks of subclinical hypoxaemia, each lasting a few days, occurred in half of those previously affected. Most episodes followed fracture operation or manipulation. Pulmonary thromboembolism seemed responsible in two patients, but it could be excluded in others given oral anticoagulant prophylaxis from soon after admission. Pulmonary fat embolism is the most likely explanation of the primary episodes and could account for most of the subsequent periods of hypoxaemia