Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.Objectives
Methods
We reviewed 35 patients who had an amputation following the failure of treatment for severe lower limb trauma. Seven of the amputations were for ischaemia, within one month of injury; 13 were between one month and one year for infection complicating loss of wound cover in un-united fractures; and 15 were later than one year after injury, mainly for infected non-union. The latter group of patients had had an average of 12 operations and 50 months of treatment, including eight months in hospital. We used a new limb injury score based on damage to the individual tissue elements; this indicated that, even in the absence of neurovascular injury, the presence of severe damage to skin, bone and muscle, with wound contamination, particularly in the lower
The parameters of cellular proliferation and growth in the growth plates of immature rats were measured after unilateral tibial osteotomy and used to calculate growth rates. Distal osteotomy of one
We have investigated the effect of currents induced by electromagnetic fields on the healing of the
The factors involved in the mechanism leading to traumatic posterior dislocation of the hip are examined. In 47 adult patients who had previously suffered such a dislocation, ultrasound scans were used to measure femoral anteversion on both the affected and the uninjured side. In 36 normal adult volunteers, used as controls, similar measurements were made. Femoral anteversion on both the injured and uninjured side was significantly reduced in the patients compared with the volunteers. These findings are discussed in the light of previous work which indicates that medial rotation is a factor in the mechanism of posterior dislocation of the hip. It is suggested that reduced anteversion acts like medial rotation to make the hip more susceptible to posterior dislocation, and that the less the anteversion the more likely is the injury to be a dislocation rather than a fracture-dislocation. It is concluded that patients who suffer such dislocated hips belong at one extreme of the normal population, having either reduced femoral anteversion or even retroversion, and that this anatomical feature selects towards hip dislocation rather than to injury of the femoral shaft, knee or
This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group. A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.Objectives
Methods
We have studied the effect of hydroxyapatite (HA) coating in 15 ovariectomised and 15 normal rats which had had a sham procedure. Twenty-four weeks after operation, HA-coated implants were inserted into the intramedullary canal of the right femur and uncoated implants into the left femur. The prostheses were removed four weeks after implantation. Twelve specimens in each group had mechanical push-out tests. Sagittal sections of the other three were evaluated by SEM. The bone mineral density (BMD) of the dissected left
We performed transoesophageal echocardiography in 111 operations (110 patients) which included medullary reaming for fresh fractures of the femur and
A clay containing hydroxyapatite (HA) was developed for use as a filling material between an uncemented implant and bone. It consists of 55% HA granules greater than 0.1 mm in size with a homogeneous pore distribution and a porosity of 35% to 48% in a saline solution of sodium alginate (6%). Ti-6A1-4V alloy rods with smooth surfaces were implanted into the distal medullary canal of one osteotomised
A computer-based model of the knee was used to study forces in the cruciate ligaments induced by co-contraction of the extensor and flexor muscles, in the absence of external loads. Ligament forces are required whenever the components of the muscle forces parallel to the tibial plateau do not balance. When the extending effect of quadriceps exactly balances the flexing effect of hamstrings, the horizontal components of the two muscle forces also balance only at the critical flexion angle of 22 degrees. The calculations show that co-contraction of the quadriceps and hamstring muscles loads the anterior cruciate ligament from full extension to 22 degrees of flexion and loads the posterior cruciate at higher flexion angles. In these two regions of flexion, the forward pull of the patellar tendon on the
Hydroxyapatite coatings for uncemented fixation in total knee
arthroplasty can theoretically provide a long-lasting biological
interface with the host bone. The objective of this study was to
test this hypothesis with propriety hydroxyapatite, peri-apatite,
coated tibial components using component migration measured with radiostereometric
analysis over two years as an indicator of long-term fixation. A total of 29 patients at two centres received uncemented PA-coated
tibial components and were followed for two years with radiostereometric
analysis exams to quantify the migration of the component.Aims
Patients and Methods
The results and complications of the use of Bailey-Dubow extensible rods in 28 lower limb bones of 10 patients suffering from osteogenesis imperfecta are reviewed. Twenty-eight operations were for the primary insertion of the rods into the femur or
The clinical features of nine new patients with dysplasia epiphysialis hemimelica are reported, with a long-term follow-up on a further seven patients who were described in the earliest case reports of this disease. Each of these 16 patients had only one leg involved, but 12 had multiple epiphyses affected. The distal femur, distal
The aims of this study were to analyse the long-term outcome
of vascularised fibular graft (VFG) reconstruction after tumour
resection and to evaluate the usefulness of the method. We retrospectively reviewed 49 patients who had undergone resection
of a sarcoma and reconstruction using a VFG between 1988 and 2015.
Their mean follow-up was 98 months (5 to 317). Reconstruction was
with an osteochondral graft (n = 13), intercalary graft (n = 12),
inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed
the oncological and functional outcome, and the rate of bony union
and complications.Aims
Patients and Methods
After intercalary resection of a bone tumour from the femur,
reconstruction with a vascularized fibular graft (VFG) and massive
allograft is considered a reliable method of treatment. However,
little is known about the long-term outcome of this procedure. The
aims of this study were to determine whether the morbidity of this
procedure was comparable to that of other reconstructive techniques,
if it was possible to achieve a satisfactory functional result, and
whether biological reconstruction with a VFG and massive allograft
could achieve a durable, long-lasting reconstruction. A total of 23 patients with a mean age of 16 years (five to 40)
who had undergone resection of an intercalary bone tumour of the
femur and reconstruction with a VFG and allograft were reviewed
clinically and radiologically. The mean follow-up was 141 months
(24 to 313). The mean length of the fibular graft was 18 cm (12 to
29). Full weight-bearing without a brace was allowed after a mean
of 13 months (seven to 26).Aims
Patients and Methods
We report the incidence of osteolysis in the femur,
The ability to determine human bone stiffness is of clinical relevance in many fields, including bone quality assessment and orthopaedic prosthesis design. Stiffness can be measured using compression testing, an experimental technique commonly used to test bone specimens A keyword search of all English language articles up until December 2017 of compression testing of bone was undertaken in Medline, Embase, PubMed, and Scopus databases. Studies using bulk tissue, animal tissue, whole bone, or testing techniques other than compression testing were excluded.Objectives
Methods
Gastrocnemius tightness predisposes to musculoskeletal pathology
and may require surgical treatment. However, it is not clear what
proportion of patients with foot and ankle pathology have clinically
significant gastrocnemius tightness. The aim of this study was to
compare the prevalence and degree of gastrocnemius tightness in
a control group of patients with a group of patients with foot and
ankle pathology. This prospective, case-matched, observational study compared
gastrocnemius tightness, as assessed by the lunge test, in a control
group and a group with foot and ankle pathology. Gastrocnemius tightness
was calculated as the difference in dorsiflexion of the ankle with
the knee extended and flexed.Aims
Patients and Methods
The role of three genetically distinct collagen types in the formation of endochondral bone and in calcification and resorption of cartilage has been assessed. Using antibodies specific to types I, II and III collagen we have demonstrated in the embryonic chick
Serial arterial blood-gas analyses showed a phase of primary hypoxaemia in thirty-two out of fifty fracture patients (64 per cent) without head, chest or abdominal injury. The incidence was greater in those with shaft fractures of the femur or