Advertisement for orthosearch.org.uk
Results 1041 - 1060 of 2209
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 256 - 262
1 May 1972
Kay NRM Martins HD

1. Thirty-nine patients with rheumatoid arthritis who had had a MacIntosh tibial plateau hemiarthroplasty are reviewed. 2. From the clinical findings it is possible to suggest a basis for the selection of suitable patients for the procedure. 3. Eighty-five per cent of the patients obtained relief of pain with good function of the knee. 4. The complications were infection and instability of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 566 - 569
1 Aug 1986
Roper B Tuke M O'Riordan S Bulstrode C

Sixty unconstrained elbow replacements of a new design have been followed prospectively for three to nine years. Review showed that 50% had excellent relief of pain and return of function, 27% had had major complications requiring removal or revision of the prosthesis and 23% had minor complications which marred the result. Further research in this field seems worthwhile


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 1 | Pages 100 - 103
1 Feb 1965
Gleave JAE

1. This is a report on the production of sockets for above-knee prostheses utilising a composite laminate of synthetic and natural materials and using a principle of total stump contact with the socket, which before fitting is shaped to suit individual stump contours. 2. A new method of taking casts is described, as is the production of the socket, and observations on the use of the prosthesis over the last two and a half years are made


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 268 - 270
1 Mar 1991
White S O'Connor J Goodfellow J

We measured the sagittal laxity in 70 knee replacements at least six months after surgery, using a KT 1000 arthrometer. With an unconstrained prosthesis (the Oxford meniscal knee) anteroposterior stability was normal in joints known to have intact cruciate ligaments. There was increased laxity in those which lacked an anterior cruciate ligament. In knees with an intact anterior cruciate ligament, sagittal laxity did not increase with time


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 962 - 965
1 Sep 2004
Ammon P Stockley I

A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement. Allograft bone was used in the second stage. Pathogenic organisms were identified in all patients. In stage 1, the prosthesis was removed together with infected tissue. Antibiotics were added to customised cement beads. Systemic antibiotics were not used. At the second stage, 45 of the patients had either acetabular impaction grafting, femoral impaction grafting or a combination; 12 had a massive allograft. Eight patients suffered recurrent infection (14%), in six with the original infecting organism. The risk factors for re-infection were multiple previous procedures and highly resistant organisms. We believe that systemic antibiotic therapy should be considered for these patients. Allograft bone is shown to be a useful adjunct in most infected hip replacements with considerable loss of bone stock


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 348 - 353
1 May 1988
Uyttendaele D De Schryver A Claessens H Roels H Berkvens P Mondelaers W

En-bloc resection, extracorporeal irradiation and re-implantation of the irradiated bone have been used to treat 15 patients suffering from primary malignant tumours of bone or cartilage and two with benign lesions. This treatment is an alternative to replacement by prosthesis or allograft bridging techniques. After a mean follow-up of over five years results are encouraging, despite some complications and the relatively long period before weight-bearing is allowed


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 24 - 28
1 Jan 1986
Cannon

Seven cases of massive osteolysis are presented. The aetiology of this disease is as yet unknown; neither age nor sex seems to be a factor in its incidence, nor are standard bone grafts or radiotherapy successful methods of treatment. However, in this series, operation produced a satisfactory outcome for five patients at a mean follow-up of 17 years; in three of these patients a custom-built prosthesis was inserted, and in one a conventional bone graft was combined with intramedullary nailing


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 754 - 756
1 Sep 1998
Shen G

The excellent long-term results for the first-generation Charnley stem may not apply to later versions with flanges. It seems possible that the early design functioned as a taper-slip system, as accepted in the Exeter prosthesis. Comparison with the requirements for the alternative composite-beam system for the femoral component shows considerable differences that have important implications. These include design, surface finish, cementing technique and the interpretation of radiological signs of loosening. A distinction should be made between the requirements for the successful use of the two different engineering systems.s


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 217 - 219
1 Mar 2004
Kralinger F Schwaiger R Wambacher M Farrell E Menth-Chiari W Lajtai G Hübner C Resch H

We have examined 167 patients who had a hemiarthroplasty for three- and four-part fractures and fracture-dislocations of the head of the humerus in a multicentre study involving 12 Austrian hospitals. All patients were followed for more than a year. Anatomical healing of the tuberosity significantly influenced the outcome as measured by the Constant score and subjective patient satisfaction. With regard to pain, the outcome was generally satisfactory but only 41.9% of patients were able to flex the shoulder above 90°. The age of the patient and the type of prosthesis significantly influenced the healing of the tuberosity, but bone grafting did not. Achievement of healing of the tuberosity was inferior in institutions at which less than 15 hemiarthroplasties had been performed (Mann-Witney U test, p = 0.0001)


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 200 - 204
1 Mar 2004
Dixon P Parish EN Chan B Chitnavis J Cross MJ

We have carried out a prospective study comparing the results at five years in patients older than 75 years of age undergoing hydroxyapatite-coated, cementless total knee replacement (TKR) with those who were younger. The Knee Society clinical rating scores were recorded before and after operation. Of 559 patients undergoing TKR, 135 were in the elderly age group. The knee scores at five years or more showed comparable results, with patients under 75 years of age reaching a score of 183 and those aged 75 years or over reaching 174. These differences were predominantly due to the functional component of the score. We conclude that elderly patients do just as well as the younger group using this prosthesis


Bone & Joint 360
Vol. 7, Issue 1 | Pages 17 - 20
1 Feb 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 74 - 77
1 Jan 1992
Butler-Manuel P James S Shepperd J

A new method to reconstruct major acetabular floor defects is described. It relies on the placement of special nails into each of the three bones of the hemipelvis. Curved lugs attached to the nails are coalesced using bone cement forming a platform onto which a standard acetabular prosthesis is located. Forty-seven cases are reported with a mean follow-up of 4.4 years (1 to 8). No loosening of an acetabular cup or migration of the device has occurred


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 18 - 22
1 Jan 1992
Jones S Pinder I Moran C Malcolm A

Isolated wear of the polyethylene tibial component led to failure in five of a series of 108 uncemented porous-coated knee replacements. The clinical features included pain, effusion and instability with progressive varus deformity. In all cases there was extensive wear on the medial side of the polyethylene surface of the prosthesis. The mechanism of such wear is complex, being due in part to the unconstrained nature of the joint and the incongruity of its surfaces. Other design characteristics may have contributed


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 1002 - 1004
1 Nov 1991
Maffulli N Fixsen J

We describe 11 children with fibular hypoplasia and three- or four-ray feet, two bilaterally. This deformity is a less severe form of the better known congenital short tibia with absent or dysplastic fibula. If the leg-length discrepancy is minor, no treatment or a simple orthosis are used. Epiphysiodesis or leg lengthening by callotasis is appropriate for mild to moderate discrepancy. If the foot is non-functional, or the projected leg-length discrepancy is too great, early amputation and a prosthesis are advised


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 388 - 389
1 May 1997
Basu P Packer CJ Himstedt J

We have assessed the effect of a variety of implants commonly used in fracture fixation and joint replacement on the activation of metal detectors at airport security gates. A volunteer with metal implants strapped on and patients with implants in situ walked through the device. Implants used in fixation do not activate it, except for Richards cannulated screws. An Austin-Moore prosthesis does set off the detector, but a single joint replacement does not. Three or four joint replacements activate the alarm and patients with these implants should be warned of this possibility


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 694 - 697
1 Jul 1990
Roper B Paterson J Day W

A simple unconstrained shoulder prosthesis has been used in 22 patients (25 shoulders) with incapacitating pain and severely damaged joints who, because of age or generalised rheumatoid disease, have limited functional requirements. All reported good and lasting pain relief. Improvement in range of movement was modest, but there was marked improvement in function. In this group of patients, rotator cuff damage is common, but does not preclude a satisfactory result


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 217 - 221
1 Mar 1989
Stone M Wilkinson R Stother I

A manufacturing technique to increase the bonding between bone cement and metal prostheses has been assessed in the laboratory by "push-out" tests, and the effects of contamination of the cement and of the prosthesis with blood and intramedullary contents have been studied. The technique, known as pre-coating, increases bond strength; this increase is preserved after contamination of the cement which does, however, cause some lowering of interface shear strength. The implications for clinical practice are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 78 - 82
1 Jan 1992
Goksan S Freeman M

One-stage reimplantation for the salvage of infected total knee arthroplasty in 18 patients was reviewed at an average follow-up of five years. There had been one recurrence and one new infection, both in rheumatoid patients with another focus of infection. In four other patients the clinical result was impaired by pain after walking (2) and limited flexion (2). Our results suggest that one-stage reimplantation is a reasonably reliable procedure for the management of a loose infected prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 494 - 497
1 Nov 1979
Mackay I Fitzgerald B Miller J

Eighteen patients with marginal depressed or comminuted fractures of the head of the radius, nine of whom had an associated posterior dislocation of the elbow, had a Silastic replacement carried out shortly after injury. After an average follow-up of twenty-six months satisfactory clinical results were observed in seventeen cases; three prostheses broke. The prosthesis has been particularly effective in the group with an associated posterior dislocation of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 600 - 607
1 Aug 1986
Thacker C Fulford P

The Denham knee replacement is a relatively simple unconstrained prosthesis. The design ensures good alignment and full extension, but does not allow flexion beyond 90 degrees or tibiofemoral rotation. The results after eight years' experience have been assessed in four different ways in over 600 cases. They show that for the limited needs of the elderly arthritic patient, the Denham arthroplasty provides a high proportion of satisfactory results with an unusually low rate of late failure