Advertisement for orthosearch.org.uk
Results 1001 - 1020 of 2654
Results per page:
Bone & Joint 360
Vol. 9, Issue 6 | Pages 5 - 11
1 Dec 2020
Sharma V Turmezei T Wain J McNamara I


Bone & Joint Open
Vol. 2, Issue 2 | Pages 93 - 102
1 Feb 2021
Thompson JW Wignadasan W Ibrahim M Beasley L Konan S Plastow R Magan A Haddad FS

Aims

We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon.

Methods

We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1142 - 1147
1 Sep 2009
Nagoya S Kaya M Sasaki M Tateda K Kosukegawa I Yamashita T

Total hip replacement for high dislocation of the hip joint remains technically difficult in terms of preparation of the true acetabulum and restoration of leg length. We describe our experience of cementless total hip replacement combined with a subtrochanteric femoral shortening osteotomy in 20 hips with Crowe grade IV dislocation with a mean follow-up of 8.1 years (4 to 11.5). There was one man and 17 women with a mean age of 55 years (44 to 69) at the time of the operation. After placment of the acetabular component at the site of the natural acetabulum, a cementless porous-coated cylindrical femoral component was implanted following a subtrochanteric femoral shortening osteotomy. The mean Japanese Orthopedic Association hip score improved from a mean of 38 (22 to 62) to a mean of 83 points (55 to 98) at the final follow-up. The mean lengthening of the leg was 14.8 mm (−9 to 34) in patients with iliofemoral osteoarthritis and 35.3 mm (15 to 51) in patients with no arthritic changes. No nerve palsy was observed. Total hip replacement combined with subtrochanteric shortening femoral osteotomy in this situation is beneficial in avoiding nerve injury and still permits valuable improvement in inequality of leg length


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 198 - 204
1 Feb 2011
Pandit H Jenkins C Gill HS Barker K Dodd CAF Murray DW

This prospective study describes the outcome of the first 1000 phase 3 Oxford medial unicompartmental knee replacements (UKRs) implanted using a minimally invasive surgical approach for the recommended indications by two surgeons and followed up independently. The mean follow-up was 5.6 years (1 to 11) with 547 knees having a minimum follow-up of five years. At five years their mean Oxford knee score was 41.3 (. sd. 7.2), the mean American Knee Society Objective Score 86.4 (. sd. 13.4), mean American Knee Society Functional Score 86.1 (. sd. 16.6), mean Tegner activity score 2.8 (. sd. 1.1). For the entire cohort, the mean maximum flexion was 130° at the time of final review. The incidence of implant-related re-operations was 2.9%; of these 29 re-operations two were revisions requiring revision knee replacement components with stems and wedges, 17 were conversions to a primary total knee replacement, six were open reductions for dislocation of the bearing, three were secondary lateral UKRs and one was revision of a tibial component. The most common reason for further surgical intervention was progression of arthritis in the lateral compartment (0.9%), followed by dislocation of the bearing (0.6%) and revision for unexplained pain (0.6%). If all implant-related re-operations are considered failures, the ten-year survival rate was 96% (95% confidence interval, 92.5 to 99.5). If only revisions requiring revision components are considered failures the ten-year survival rate is 99.8% (confidence interval 99 to 100). This is the largest published series of UKRs implanted through a minimally invasive surgical approach and with ten-year survival data. The survival rates are similar to those obtained with a standard open approach whereas the function is better. This demonstrates the effectiveness and safety of a minimally invasive surgical approach for implanting the Oxford UKR


Bone & Joint 360
Vol. 9, Issue 5 | Pages 44 - 46
1 Oct 2020


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1311 - 1318
3 Oct 2020
Huang Y Gao Y Li Y Ding L Liu J Qi X

Aims

Morphological abnormalities are present in patients with developmental dysplasia of the hip (DDH). We studied and compared the pelvic anatomy and morphology between the affected hemipelvis with the unaffected side in patients with unilateral Crowe type IV DDH using 3D imaging and analysis.

Methods

A total of 20 patients with unilateral Crowe-IV DDH were included in the study. The contralateral side was considered normal in all patients. A coordinate system based on the sacral base (SB) in a reconstructed pelvic model was established. The pelvic orientations (tilt, rotation, and obliquity) of the affected side were assessed by establishing a virtual anterior pelvic plane (APP). The bilateral coordinates of the anterior superior iliac spine (ASIS) and the centres of hip rotation were established, and parameters concerning size and volume were compared for both sides of the pelvis.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1303 - 1310
3 Oct 2020
Kjærgaard K Ding M Jensen C Bragdon C Malchau H Andreasen CM Ovesen O Hofbauer C Overgaard S

Aims

The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm).

Methods

Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months.


Bone & Joint 360
Vol. 9, Issue 4 | Pages 21 - 22
1 Aug 2020


Bone & Joint Open
Vol. 2, Issue 1 | Pages 48 - 57
19 Jan 2021
Asokan A Plastow R Kayani B Radhakrishnan GT Magan AA Haddad FS

Cementless knee arthroplasty has seen a recent resurgence in popularity due to conceptual advantages, including improved osseointegration providing biological fixation, increased surgical efficiency, and reduced systemic complications associated with cement impaction and wear from cement debris. Increasingly younger and higher demand patients are requiring knee arthroplasty, and as such, there is optimism cementless fixation may improve implant survivorship and functional outcomes.

Compared to cemented implants, the National Joint Registry (NJR) currently reports higher revision rates in cementless total knee arthroplasty (TKA), but lower in unicompartmental knee arthroplasty (UKA). However, recent studies are beginning to show excellent outcomes with cementless implants, particularly with UKA which has shown superior performance to cemented varieties. Cementless TKA has yet to show long-term benefit, and currently performs equivalently to cemented in short- to medium-term cohort studies. However, with novel concepts including 3D-printed coatings, robotic-assisted surgery, radiostereometric analysis, and kinematic or functional knee alignment principles, it is hoped they may help improve the outcomes of cementless TKA in the long-term. In addition, though cementless implant costs remain higher due to novel implant coatings, it is speculated cost-effectiveness can be achieved through greater surgical efficiency and potential reduction in revision costs. There is paucity of level one data on long-term outcomes between fixation methods and the cost-effectiveness of modern cementless knee arthroplasty.

This review explores recent literature on cementless knee arthroplasty, with regards to clinical outcomes, implant survivorship, complications, and cost-effectiveness; providing a concise update to assist clinicians on implant choice.

Cite this article: Bone Jt Open 2021;2(1):48–57.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 255 - 258
1 Mar 1999
Paton RW Srinivasan MS Shah B Hollis S

Between May 1992 and April 1997, there were 20 452 births in the Blackburn District. In the same period 1107 infants with hip ‘at-risk’ factors were screened prospectively by ultrasound. We recorded the presence of dislocation and dysplasia detected under the age of six months using Graf’s alpha angle. Early dislocation was present in 36 hips (34 dislocatable and 2 irreducible). Of the 36 unstable hips, 30 (83%) were referred as being Ortolani-positive or unstable; 25 (69%) of these had at least one of the risk factors. Only 11 (31%) were identified from the ‘at-risk’ screening programme alone (0.54 per 1000 live births). Eight cases of ‘late’ dislocation presented after the age of six months (0.39 per 1000 live births). The overall rate of dislocation was 2.2 per 1000 live births. Only 31% of the dislocated hips belonged to a major ‘at-risk’ group. Statistical analysis confirmed that the risk factors had a relatively poor predictive value if used as a screening test for dislocation. In infants referred for doubtful clinical instability, one dislocation was detected for every 11 infants screened (95% confidence interval (CI) 8 to 17) whereas in infants referred because of the presence of any of the major ‘at-risk’ factors the rate was one in 75 (95% CI 42 to 149). Routine ultrasound screening of the ‘at-risk’ groups on their own is of little value in significantly reducing the rate of ‘late’ dislocation in DDH, but screening clinically unstable hips alone or associated with ‘at-risk’ factors has a high rate of detection


Bone & Joint 360
Vol. 3, Issue 5 | Pages 12 - 16
1 Oct 2014

The October 2014 Knee Roundup. 360 . looks at: microfracture equivalent to OATS; examination better than MRI in predicting hamstrings re-injury; a second view on return to play with hamstrings injuries; dislocation risks in the Oxford Unicompartmental Knee; what about the tibia?; getting on top of lateral facet pain post TKR; readmission in TKR; patient-specific instrumentation; treating infrapatellar saphenous neuralgia; and arthroscopy in the middle-aged


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 260 - 265
1 Feb 2016
Sorel JC Façee Schaeffer M Homan AS Scholtes VAB Kempen DHR Ham SJ

Aims. We report a prospective cohort study of the midterm results of surgical dislocation of the hip (according to Ganz) to perform resection of osteochondromas involving the femoral neck in patients with multiple hereditary exostoses (MHE). . Methods. Hip range of movement (ROM) was assessed pre- and post-operatively. Patients’ judgment of post-operative reduction of pain, symptoms, the Rand 36-item Health Survey (RAND-36) and complications were analysed. . Results. Symptomatic osteochondromas of the femoral neck were removed in 20 hips (17 patients) between 2007 and 2012. There were nine men and eight women with a mean age at the time of surgery of 29 years (11 to 47). Mean follow-up was 46 months (26 to 73). At latest follow-up, mean ROM was significantly increased in all directions. Post-operatively the pain associated with the lesion was either significantly decreased or non-existent. There was a significant improvement in seven RAND-36 sub-domains. Encountered complications in four patients were pseudoarthrosis of the trochanteric osteotomy, traumatic separation of the trochanteric osteotomy, a pertrochanteric femoral fracture and avasvular necrosis. Histological analysis revealed osteochondromas in all hips. . Discussion. This study confirms the Ganz trochanteric flip osteotomy provided a reliable approach to osteochondromas of the femoral neck that are otherwise difficult to access for surgical resection. The procedure offered significant improvement in the quality of life, although one should be aware of the serious complications can arise despite the relatively safe procedure. Take home message: When daily function and activities are affected, resection of osteochondromas of the proximal femur according to Ganz is indicated to significantly improve quality of life. Cite this article: Bone Joint J 2016;98-B:260–5


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1618 - 1619
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 754 - 760
1 Jun 2016
Malek IA Royce G Bhatti SU Whittaker JP Phillips SP Wilson IRB Wootton JR Starks I

Aims. We assessed the difference in hospital based and early clinical outcomes between the direct anterior approach and the posterior approach in patients who undergo total hip arthroplasty (THA). Patients and Methods. The outcome was assessed in 448 (203 males, 245 females) consecutive patients undergoing unilateral primary THA after the implementation of an ‘Enhanced Recovery’ pathway. In all, 265 patients (mean age: 71 years (49 to 89); 117 males and 148 females) had surgery using the direct anterior approach (DAA) and 183 patients (mean age: 70 years (26 to 100); 86 males and 97 females) using a posterior approach. The groups were compared for age, gender, American Society of Anesthesiologists grade, body mass index, the side of the operation, pre-operative Oxford Hip Score (OHS) and attendance at ‘Joint school’. Mean follow-up was 18.1 months (one to 50). Results. There was no significant difference in mean length of stay (p = 0.07), pain scores on the day of surgery, the first, second and third post-operative days (p = 0.36, 0.23, 0.25 and 0.59, respectively), the day of mobilisation (p = 0.12), the mean OHS at six and 24 months (p = 0.08, and 0.29, respectively), the incidence of infection (p = 1.0), dislocation (p = 1.0), re-operation (p = 0.21) or 28 days’ re-admission (p = 0.06). Significantly more patients in the DAA group achieved a planned discharge target of three days post-operatively (68% vs 56%, p = 0.007). The rate of periprosthetic femoral fractures was significantly higher in the DAA group (p = 0.04). Conclusion. We conclude that there is no difference in clinical outcomes between the DAA and the posterior approach in patients undergoing THA when an ‘Enhanced Recovery’ pathway is used. However, a significantly higher rate of periprosthetic femoral fractures remains a concern with the DAA, even in experienced hands. Take home message: Our results show that the DAA for THA is not superior to posterior approach when ‘Enhanced Recovery’ pathway is used. Cite this article: Bone Joint J 2016;98-B:754–60


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 202 - 208
1 Feb 2010
Berton C Girard J Krantz N Migaud H

Implantation of a large-diameter femoral head prosthesis with a metal-on-metal bearing surface reduces the risk of dislocation, increases the range of movement, minimises the risk of impingement and, in theory, results in little wear. Between February 2004 and March 2007 we implanted 100 consecutive total hip replacements with a metal-on-metal bearing and a large femoral head into 92 patients. There were 51 men and 41 women with a mean age of 50 years (18 to 70) at the time of surgery. Outcome was assessed using the Western Ontario McMaster University osteoarthritis index and the Harris hip score as well as the Devane activity score. These all improved significantly (p < 0.0001). At the last follow-up there were no cases of dislocation, no impingement, a good range of movement and no osteolysis, but seven revisions, two for infection and five for aseptic loosening. The probability of groin pain increased if the other acetabular component inclination exceeded 50° (p = 0.0007). At 4.8 years of follow-up, the projected survival of the Durom acetabular component, with revision for any reason, was 92.4% (. sd. 2.8) (95% confidence interval 89.6 to 95.2). The design of the component made it difficult both to orientate and seat, which when combined with a poor porous coating, produced unpredictable fixation and a low survival at five years


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 655 - 658
1 May 2009
Paton RW Choudry Q

In a prospective study over 11 years we assessed the relationship between neonatal deformities of the foot and the presence of ultrasonographic developmental dysplasia of the hip (DDH). Between 1 January 1996 and 31 December 2006, 614 infants with deformities of the foot were referred for clinical and ultrasonographic evaluation. There were 436 cases of postural talipes equinovarus deformity (TEV), 60 of fixed congenital talipes equinovarus (CTEV), 93 of congenital talipes calcaneovalgus (CTCV) and 25 of metatarsus adductus. The overall risk of ultrasonographic dysplasia or instability was 1:27 in postural TEV, 1:8.6 in CTEV, 1:5.2 in CTCV and 1:25 in metatarsus adductus. The risk of type-IV instability of the hip or irreducible dislocation was 1:436 (0.2%) in postural TEV, 1:15.4 (6.5%) in CTCV and 1:25 (4%) in metatarsus adductus. There were no cases of hip instability (type IV) or of irreducible dislocation in the CTEV group. Routine screening for DDH in cases of postural TEV and CTEV is no longer advocated. The former is poorly defined, leading to the over-diagnosis of a possibly spurious condition. Ultrasonographic imaging and surveillance of hips in infants with CTCV and possibly those with metatarsus adductus should continue


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 696 - 704
1 May 2015
Kenawey M Krettek C Addosooki A Salama W Liodakis E

Unstable pelvic injuries in young children with an immature pelvis have different modes of failure from those in adolescents and adults. We describe the pathoanatomy of unstable pelvic injuries in these children, and the incidence of associated avulsion of the iliac apophysis and fracture of the ipsilateral fifth lumbar transverse process (L5-TP). We retrospectively reviewed the medical records of 33 children with Tile types B and C pelvic injuries admitted between 2007 and 2014; their mean age was 12.6 years (2 to 18) and 12 had an immature pelvis. Those with an immature pelvis commonly sustained symphyseal injuries anteriorly with diastasis, rather than the fractures of the pubic rami seen in adolescents. Posteriorly, transsacral fractures were more commonly encountered in mature children, whereas sacroiliac dislocations and fracture-dislocations were seen in both age groups. Avulsion of the iliac apophysis was identified in eight children, all of whom had an immature pelvis with an intact ipsilateral L5-TP. Young children with an immature pelvis are more susceptible to pubic symphysis and sacroiliac diastasis, whereas bony failures are more common in adolescents. Unstable pelvic injuries in young children are commonly associated with avulsion of the iliac apophysis, particularly with displaced SI joint dislocation and an intact ipsilateral L5-TP. Cite this article: Bone Joint J 2015; 97-B:696–704


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1113 - 1121
14 Sep 2020
Nantha Kumar N Kunutsor SK Fernandez MA Dominguez E Parsons N Costa ML Whitehouse MR

Aims

We conducted a systematic review and meta-analysis to compare the mortality, morbidity, and functional outcomes of cemented versus uncemented hemiarthroplasty in the treatment of intracapsular hip fractures, analyzing contemporary and non-contemporary implants separately.

Methods

PubMed, Medline, EMBASE, CINAHL, and Cochrane Library were searched to 2 February 2020 for randomized controlled trials (RCTs) comparing the primary outcome, mortality, and secondary outcomes of function, quality of life, reoperation, postoperative complications, perioperative outcomes, pain, and length of hospital stay. Relative risks (RRs) and mean differences (with 95% confidence intervals (CIs)) were used as summary association measures.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1501 - 1508
1 Nov 2010
Donell ST Darrah C Nolan JF Wimhurst J Toms A Barker THW Case CP Tucker JK

Metal-on-metal total hip replacement has been targeted at younger patients with anticipated long-term survival, but the effect of the production of metal ions is a concern because of their possible toxicity to cells. We have reviewed the results of the use of the Ultima hybrid metal-on-metal total hip replacement, with a cemented polished tapered femoral component with a 28 mm diameter and a cobalt-chrome (CoCr) modular head, articulating with a 28 mm CoCr acetabular bearing surface secured in a titanium alloy uncemented shell. Between 1997 and 2004, 545 patients with 652 affected hips underwent replacement using this system. Up to 31 January 2008, 90 (13.8%) hips in 82 patients had been revised. Pain was the sole reason for revision in 44 hips (48.9%) of which 35 had normal plain radiographs. Peri-prosthetic fractures occurred in 17 hips (18.9%) with early dislocation in three (3.3%) and late dislocation in 16 (17.8%). Infection was found in nine hips (10.0%). At operation, a range of changes was noted including cavities containing cloudy fluid under pressure, necrotic soft tissues with avulsed tendons and denuded osteonecrotic upper femora. Corrosion was frequently observed on the retrieved cemented part of the femoral component. Typically, the peri-operative findings confirmed those found on pre-operative metal artefact reduction sequence MRI and histological examination showed severe necrosis. Metal artefact reduction sequence MRI proved to be useful when investigating these patients with pain in the absence of adverse plain radiological features


Bone & Joint Research
Vol. 10, Issue 1 | Pages 22 - 30
1 Jan 2021
Clement ND Gaston P Bell A Simpson P Macpherson G Hamilton DF Patton JT

Aims

The primary aim of this study was to compare the hip-specific functional outcome of robotic assisted total hip arthroplasty (rTHA) with manual total hip arthroplasty (mTHA) in patients with osteoarthritis (OA). Secondary aims were to compare general health improvement, patient satisfaction, and radiological component position and restoration of leg length between rTHA and mTHA.

Methods

A total of 40 patients undergoing rTHA were propensity score matched to 80 patients undergoing mTHA for OA. Patients were matched for age, sex, and preoperative function. The Oxford Hip Score (OHS), Forgotten Joint Score (FJS), and EuroQol five-dimension questionnaire (EQ-5D) were collected pre- and postoperatively (mean 10 months (SD 2.2) in rTHA group and 12 months (SD 0.3) in mTHA group). In addition, patient satisfaction was collected postoperatively. Component accuracy was assessed using Lewinnek and Callanan safe zones, and restoration of leg length were assessed radiologically.