Advertisement for orthosearch.org.uk
Results 981 - 1000 of 1194
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 697 - 707
1 Jun 2008
Fraser-Moodie JA Shortt NL Robinson CM

Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 33 - 34
1 Apr 2012
Benazzo F


Bone & Joint 360
Vol. 1, Issue 4 | Pages 19 - 22
1 Aug 2012

The August 2012 Shoulder & Elbow Roundup360 looks at: platelet-rich fibrin matrix and the torn rotator cuff; ultrasound, trainees, and ducks out of water; the torn rotator cuff and conservative treatment; Bankart repair and subsequent degenerative change; proprioception after shoulder replacement; surgery for a terrible triad, with reasonable short-term results; and the WORC Index.


Bone & Joint Research
Vol. 1, Issue 12 | Pages 324 - 332
1 Dec 2012
Verhelst L Guevara V De Schepper J Van Melkebeek J Pattyn C Audenaert EA

The aim of this review is to evaluate the current available literature evidencing on peri-articular hip endoscopy (the third compartment). A comprehensive approach has been set on reports dealing with endoscopic surgery for recalcitrant trochanteric bursitis, snapping hip (or coxa-saltans; external and internal), gluteus medius and minimus tears and endoscopy (or arthroscopy) after total hip arthroplasty. This information can be used to trigger further research, innovation and education in extra-articular hip endoscopy.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 41 - 50
1 Feb 2013
Cottrell JA Keshav V Mitchell A O’Connor JP

Objectives

Recent studies have shown that modulating inflammation-related lipid signalling after a bone fracture can accelerate healing in animal models. Specifically, decreasing 5-lipoxygenase (5-LO) activity during fracture healing increases cyclooxygenase-2 (COX-2) expression in the fracture callus, accelerates chondrogenesis and decreases healing time. In this study, we test the hypothesis that 5-LO inhibition will increase direct osteogenesis.

Methods

Bilateral, unicortical femoral defects were used in rats to measure the effects of local 5-LO inhibition on direct osteogenesis. The defect sites were filled with a polycaprolactone (PCL) scaffold containing 5-LO inhibitor (A-79175) at three dose levels, scaffold with drug carrier, or scaffold only. Drug release was assessed in vitro. Osteogenesis was assessed by micro-CT and histology at two endpoints of ten and 30 days.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 777 - 780
1 Jun 2010
Contreras MEK Dani WS Endges WK De Araujo LCT Berral FJ

We undertook a prospective pilot study to determine whether arthroscopic surgery through the central compartment of the hip was effective in the management of a snapping iliopsoas tendon. Seven patients were assessed pre-operatively and at three, six, 12 and 24 months after operation. This included the assessment of pain on a visual analogue scale (VAS) and function using the modified Harris hip score.

All the patients had resolution of snapping post-operatively and this persisted at follow-up at two years. The mean VAS score for pain fell from 7.7 (6 to 10) pre-operatively to 4.3 (0 to 10) by three months (p = 0.051), and to 3.6 (1 to 8) (p = 0.015), 2.4 (0 to 8) (p = 0.011) and 2.4 (0 to 8) (p = 0.011) by six, 12 and 24 months, respectively. The mean modified Harris hip score increased from 56.1 (13.2 to 84.7) pre-operatively to 88.4 (57.2 to 100) at one year (p = 0.018) and to 87.9 (49.5 to 100) at two years (p = 0.02). There were no complications and no weakness occurred in the musculature around the hip.

Our findings suggest that this treatment is effective and would support the undertaking of a larger study comparing this procedure with other methods of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1112 - 1117
1 Aug 2010
Clement ND Hallett A MacDonald D Howie C McBirnie J

We compared the outcome of arthroscopic repair of the rotator cuff in 32 diabetic patients with the outcome in 32 non-diabetic patients matched for age, gender, size of tear and comorbidities. The Constant-Murley score improved from a mean of 49.2 (24 to 80) pre-operatively to 60.8 (34 to 95) post-operatively (p = 0.0006) in the diabetic patients, and from 46.4 (23 to 90) pre-operatively to 65.2 (25 to 100) post-operatively (p = 0.0003) in the non-diabetic patients at six months. This was significantly greater (p = 0.0002) in non-diabetic patients (18.8) than in diabetics (11.6). There was no significant change in the mean mental component of the Short-Form 12, but the mean physical component increased from 35 to 41 in non-diabetics (p = 0.0001), and from 37 to 39 (p = 0.15) in diabetics. These trends were observed at one year.

Patients with diabetes showed improvement of pain and function following arthroscopic rotator cuff repair in the short term, but less than their non-diabetic counterparts.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 10 - 19
1 Jan 2013
Bedi A Kelly BT Khanduja V

The technical advances in arthroscopic surgery of the hip, including the improved ability to manage the capsule and gain extensile exposure, have been paralleled by a growth in the number of conditions that can be addressed. This expanding list includes symptomatic labral tears, chondral lesions, injuries of the ligamentum teres, femoroacetabular impingement (FAI), capsular laxity and instability, and various extra-articular disorders, including snapping hip syndromes. With a careful diagnostic evaluation and technical execution of well-indicated procedures, arthroscopic surgery of the hip can achieve successful clinical outcomes, with predictable improvements in function and pre-injury levels of physical activity for many patients.

This paper reviews the current position in relation to the use of arthroscopy in the treatment of disorders of the hip.

Cite this article: Bone Joint J 2013;95-B:10–19.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1325 - 1331
1 Oct 2010
Patel S Rodriguez-Merchan EC Haddad FS

Fibrin glue, also known as fibrin sealant, is now established as a haemostatic agent in surgery, but its role in orthopaedic surgery is neither well known nor clearly defined. Although it was originally used over 100 years ago, concerns about transmission of disease meant that it fell from favour. It is also available as a slow-release drug delivery system and as a substrate for cellular growth and tissue engineering. Consequently, it has the potential to be used in a number of ways in orthopaedic surgery. The purpose of this review is to address its use in surgery of the knee in which it appears to offer great promise.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 583 - 597
1 May 2013
Kurien T Pearson RG Scammell BE

We reviewed 59 bone graft substitutes marketed by 17 companies currently available for implantation in the United Kingdom, with the aim of assessing the peer-reviewed literature to facilitate informed decision-making regarding their use in clinical practice. After critical analysis of the literature, only 22 products (37%) had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita), Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question the need for so many different products, especially with limited published clinical evidence for their efficacy, and conclude that there is a considerable need for further prospective randomised trials to facilitate informed decision-making with regard to the use of current and future bone graft substitutes in clinical practice.

Cite this article: Bone Joint J 2013;95-B:583–97.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1187 - 1192
1 Sep 2012
Rakhra KS Lattanzio P Cárdenas-Blanco A Cameron IG Beaulé PE

Advanced MRI cartilage imaging such as T1-rho (T1ρ) for the diagnosis of early cartilage degradation prior to morpholgic radiological changes may provide prognostic information in the management of joint disease. This study aimed first to determine the normal T1ρ profile of cartilage within the hip, and secondly to identify any differences in T1ρ profile between the normal and symptomatic femoroacetabular impingement (FAI) hip. Ten patients with cam-type FAI (seven male and three female, mean age 35.9 years (28 to 48)) and ten control patients (four male and six female, mean age 30.6 years (22 to 35)) underwent 1.5T T1ρ MRI of a single hip. Mean T1ρ relaxation times for full thickness and each of the three equal cartilage thickness layers were calculated and compared between the groups. The mean T1ρ relaxation times for full cartilage thickness of control and FAI hips were similar (37.17 ms (sd 9.95) and 36.71 ms (sd 6.72), respectively). The control group demonstrated a T1ρ value trend, increasing from deep to superficial cartilage layers, with the middle third having significantly greater T1ρ relaxation values than the deepest third (p = 0.008). The FAI group demonstrated loss of this trend. The deepest third in the FAI group demonstrated greater T1ρ relaxation values than controls (p = 0.028).

These results suggest that 1.5T T1ρ MRI can detect acetabular hyaline cartilage changes in patients with FAI.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1033 - 1040
1 Jul 2010
Nishino T Chang F Ishii T Yanai T Mishima H Ochiai N

We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1101 - 1106
1 Aug 2012
Jindal N Sankhala SS Bachhal V

The purpose of this study was to determine whether patients with a burst fracture of the thoracolumbar spine treated by short segment pedicle screw fixation fared better clinically and radiologically if the affected segment was fused at the same time. A total of 50 patients were enrolled in a prospective study and assigned to one of two groups. After the exclusion of three patients, there were 23 patients in the fusion group and 24 in the non-fusion group. Follow-up was at a mean of 23.9 months (18 to 30). Functional outcome was evaluated using the Greenough Low Back Outcome Score. Neurological function was graded using the American Spinal Injury Association Impairment Scale. Radiological outcome was assessed on the basis of the angle of kyphosis.

Peri-operative blood transfusion requirements and duration of surgery were significantly higher in the fusion group (p = 0.029 and p < 0.001, respectively). There were no clinical or radiological differences in outcome between the groups (all outcomes p > 0.05). The results of this study suggest that adjunctive fusion is unnecessary when managing patients with a burst fracture of the thoracolumbar spine with short segment pedicle screw fixation.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 13 - 14
1 Feb 2012


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1305 - 1312
1 Oct 2012
Adams J Ryall C Pandyan A Metcalf C Stokes M Bradley S Warwick DJ

We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications.

Original studies were selected if they reported clinical outcome with a minimum of one year’s follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37).

We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence.

We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 20 - 21
1 Feb 2012


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 488 - 492
1 Apr 2012
Vijayan S Bartlett W Bentley G Carrington RWJ Skinner JA Pollock RC Alorjani M Briggs TWR

Matrix-induced autologous chondrocyte implantation (MACI) is an established technique used to treat osteochondral lesions in the knee. For larger osteochondral lesions (> 5 cm2) deeper than approximately 8 mm we have combined the use of two MACI membranes with impaction grafting of the subchondral bone. We report our results of 14 patients who underwent the ‘bilayer collagen membrane’ technique (BCMT) with a mean follow-up of 5.2 years (2 to 8). There were 12 men and two women with a mean age of 23.6 years (16 to 40). The mean size of the defect was 7.2 cm2 (5.2 to 12 cm2) and were located on the medial (ten) or lateral (four) femoral condyles. The mean modified Cincinnati knee score improved from 45.1 (22 to 70) pre-operatively to 82.8 (34 to 98) at the most recent review (p < 0.05). The visual analogue pain score improved from 7.3 (4 to 10) to 1.7 (0 to 6) (p < 0.05). Twelve patients were considered to have a good or excellent clinical outcome. One graft failed at six years.

The BCMT resulted in excellent functional results and durable repair of large and deep osteochondral lesions without a high incidence of graft-related complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 533 - 535
1 Apr 2009
Hamilton LC Biant LC Temple LN Field RE

Idiopathic calcium pyrophosphate deposition disease (pseudogout) has a variable presentation. Many joints are usually affected; single joint disease is uncommon. We present a case report of primary monoarticular pseudogout affecting the hip. The diagnosis was made on the appearance and analysis of specimens obtained at arthroscopy. Monoarticular pseudogout is rare, but should be considered in the differential diagnosis of any presentation of joint pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 915 - 917
1 Jul 2009
Gwilym SE Watkins B Cooper CD Harvie P Auplish S Pollard TCB Rees JL Carr AJ

The aim of this study was to investigate genetic influences on the development and progression of tears of the rotator cuff. From a group of siblings of patients with a tear of the rotator cuff and of controls studied five years earlier, we determined the prevalence of tears of the rotator cuff with and without associated symptoms using ultrasound and the Oxford Shoulder Score.

In the five years since the previous assessment, three of 62 (4.8%) of the sibling group and one of the 68 (1.5%) controls had undergone shoulder surgery. These subjects were excluded from the follow-up.

Full-thickness tears were found in 39 of 62 (62.9%) siblings and in 15 of 68 (22.1%) controls (p = 0.0001). The relative risk of full-thickness tears in siblings as opposed to controls was 2.85 (95% confidence interval (CI) 1.75 to 4.64), compared to 2.42 (95% CI 1.77 to 3.31) five years earlier. Full-thickness tears associated with pain were found in 30 of 39 (76.9%) tears in the siblings and in eight of 15 (53.3%) tears in the controls (p = 0.045). The relative risk of pain associated with a full-thickness tear in the siblings as opposed to the controls was 1.44 (95% CI 2.04 to 8.28) (p = 0.045).

In the siblings group ten of 62 (16.1%) had progressed in terms of tear size or development compared to one of 68 (1.5%) in the control group which had increased in size.

Full-thickness rotator cuff tears in siblings are significantly more likely to progress over a period of five years than in a control population. This implies that genetic factors have a role, not only in the development but also in the progression of full-thickness tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 448 - 453
1 Mar 2010
Benson RT McDonnell SM Knowles HJ Rees JL Carr AJ Hulley PA

The aim of this study was to investigate the occurrence of tissue hypoxia and apoptosis at different stages of tendinopathy and tears of the rotator cuff.

We studied tissue from 24 patients with eight graded stages of either impingement (mild, moderate and severe) or tears of the rotator cuff (partial, small, medium, large and massive) and three controls. Biopsies were analysed using three immunohistochemical techniques, namely antibodies against HIF-1α (a transcription factor produced in a hypoxic environment), BNip3 (a HIF-1α regulated pro-apoptotic protein) and TUNEL (detecting DNA fragmentation in apoptosis).

The HIF-1α expression was greatest in mild impingement and in partial, small, medium and large tears. BNip3 expression increased significantly in partial, small, medium and large tears but was reduced in massive tears. Apoptosis was increased in small, medium, large and massive tears but not in partial tears.

These findings reveal evidence of hypoxic damage throughout the spectrum of pathology of the rotator cuff which may contribute to loss of cells by apoptosis. This provides a novel insight into the causes of degeneration of the rotator cuff and highlights possible options for treatment.