header advert
Results 81 - 86 of 86
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 169 - 169
1 Jan 1996
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 916 - 919
1 Nov 1991
Laurence M

The rotator cuff is often severely damaged in arthritis of the shoulder and there is no satisfactory technique for its repair. patients with a ruptured cuff and an eroded glenohumeral joint may have intractable pain, and standard methods of joint replacement are then inappropriate. A ball and socket prosthesis has been designed to replace the function of both the rotator cuff and the glenohumeral joint. Mechanical testing has shown that the scapular cup can be securely fixed. The outcome in 71 shoulders operated upon since 1973 is reported.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 600 - 602
1 Jul 1991
Yanni D Lieppins P Laurence M

The effect of the position of splintage on displacement of fractures of the waist of the scaphoid was studied during operations and in cadavers. We found that these fractures were best splinted in neutral or slight palmar flexion with no ulnar deviation. Providing the wrist was not ulnar deviated, the position of the thumb had no effect on displacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 375 - 377
1 Aug 1983
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 754 - 768
1 Nov 1969
Laurence M Freeman MAR Swanson SAV

1. The probable greatest bending moment applied to a plated or nailed fracture of the tibia during restricted weight-bearing is estimated to be, in men, up to about 79 Newton metres (58 poundsforce feet). The maximum twisting moment is estimated to be about 29 Newton metres (22 poundsforce feet).

2. Twenty-two human tibiae were loaded in three-point bending and broke at bending moments of from 57·9 to 294 Newton metres (42·7 to 216 poundsforce feet) if they had not previously been drilled; tibiae which had holes made through both cortices with a c. 3-millimetre (⅛-inch) drill broke at from 32·4 to 144 Newton metres (23·8 to 106 poundsforce feet). Tibiae loaded in torsion broke at twisting moments of from 27·5 to 892 Newton metres (20·2 to 65·8 poundsforce feet) when not drilled, 23·6 to 77·5 Newton metres (l7·3 to 57·1 poundsforce feet) when drilled.

3. When bent so as to open the fracture site, the 14-centimetre Stamm was the strongest of all the single plates tested (reaching its elastic limit at a bending moment of 17·6 Newton metres (13 poundsforce feet) and 5 degrees total angulation at 22·6 Newton metres (16·6 poundsforce feet)), while the Venable was the weakest (elastic limit 4·9 Newton metres (3·6 poundsforce feet) and 5 degrees at 7·9 Newton metres (5·8 poundsforce feet)). A 13-millimetre Küntscher nail reached its elastic limit at 42·2 Newton metres (31·1 poundsforce feet) and 5 degrees total angulation at 49 Newton metres (36 poundsforce feet).

4. In torsion the 15-centimetre Hicks was the strongest ofthe plates (elastic limit 27·5 Newton metres (20·2 poundsforce feet) and 5 degrees rotation at 16·7 Newton metres (l2·3 poundsforce feet)).

5. Küntscher nails in bones provided no dependable strength in torsion.

6. In both bending and torsion, a preparation of one Venable plate on each of the two anterior surfaces was stronger than any single plate, and was as strong as the weaker drilled tibiae.

7. The three currently available metallic materials (stainless steel, cobalt-chrome and titanium) have static mechanical properties so similar that the choice between them can be made on other grounds.

8. The highest load applied to a screw during bending tests was about half that needed to pull a screw out of even a thin-walled tibia.

9. Screws beyond four for one plate are mechanically redundant at the moment of implantation but may be necessary as an insurance against subsequent deterioration in strength.

10. Countersinks in plates are a source of significant weakness, and should preferably be as shallow as possible.

11. An unoccupied screw hole in the centre of a plate is a source of serious weakness.

12. Only the strongest implants tested were strong enough to withstand the bending or twisting moments to be expected in restricted weight-bearing. In two-plate preparations a danger is introduced by the fact that these moments are similar to those required to Ireak a drilled tibia.


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 1 | Pages 121 - 134
1 Feb 1967
Laurence M

1. Thirty-two infants with genu recurvatum congenitum are reported.

2. Fifteen infants responded completely within eight weeks with conservative treatment; the remaining cases were recalcitrant.

3. The etiology, pathology and treatment of the two groups are discussed.

4. The prognosis is adversely affected by delay in treatment by the presence of certain associated deformities and by generalised joint laxity.

5. Indications for operative treatment are suggested.