Advertisement for orthosearch.org.uk
Results 81 - 100 of 1515
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1210 - 1210
1 Nov 2001
PARKER M


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 662 - 663
1 Jul 1993
Hamer A Stanley D Smith T


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 858 - 861
1 Nov 1992
Casteleyn P Handelberg F Haentjens P

In a prospective trial, biodegradable polyglycolic acid rods were compared with Kirschner wires for fixation of wrist fractures (Frykman types I, II, V and VI). Fifteen patients were randomly assigned to each treatment group. There was no significant difference between the groups with regard to age, sex ratio and fracture type. Kapandji's pinning technique was used in all cases. There were no significant differences in the results obtained in both groups at final follow-up. At three months and six months the functional results of the Kirschner-wire group were, however, significantly better (p < 0.05), due to numerous transient complications from foreign-body reactions to the polyglycolic acid rods. The use of polyglycolic acid rods is therefore not recommended for the fixation of distal radial fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 654 - 659
1 Jul 1991
Kenwright J Richardson J Cunningham J White S Goodship A Adams M Magnussen P Newman J

Diaphyseal fractures of the tibia in 80 patients were treated by external skeletal fixation using a unilateral frame, either in a fixed mode or in a mode which allowed the application of a small amount of predominantly axial micromovement. Patients were allocated to each regime by random selection. Fracture healing was assessed clinically, radiologically and by measurement of the mechanical stiffness of the fracture. Both clinical and mechanical healing were enhanced in the group subjected to micromovement, compared to those treated with frames in a fixed mode possessing an overall stiffness similar to that of others in common clinical use. The differences in healing time were statistically significant and independently related to the treatment method. There was no difference in complication rates between treatment groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 848 - 850
1 Nov 1989
Bannister G Wallace W Stableforth P Hutson M

In a prospective study, 60 patients with acute acromioclavicular dislocation were randomly allocated to treatment with a broad arm sling or to reduction and fixation with a coracoclavicular screw. Of these 54 were followed for four years. Conservatively-treated patients regained movement significantly more quickly and fully, returned to work and sport earlier and had fewer unsatisfactory results than those having early operation. For severe dislocations, with acromioclavicular displacement of 2 cm or more, early surgery produced better results. Conservative management is best for most acute dislocations, but younger patients with severe displacement may benefit from early reduction and stabilisation.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 160 - 165
1 Feb 2007
Blomfeldt R Törnkvist H Eriksson K Söderqvist A Ponzer S Tidermark J

The best treatment for the active and lucid elderly patient with a displaced intracapsular fracture of the femoral neck is still controversial. Randomised controlled trials have shown that a primary total hip replacement is superior to internal fixation as regards the need for secondary surgery, hip function and health-related quality of life. Despite good results achieved with total hip replacement in this group, most orthopaedic surgeons still advocate hemiarthroplasty for this injury. We studied 120 patients with a mean age of 81 years (70 to 90) with an acute displaced intracapsular fracture of the femoral neck. They were randomly allocated to be treated with either a bipolar hemiarthroplasty or total hip replacement. Outcome measurements included peri-operative data, general and hip-specific complications, hip function and health-related quality of life. The patients were reviewed at four and 12 months.

The duration of surgery was longer in the total hip replacement group (102 minutes (70 to 151)) versus 78 minutes (43 to 131) (p < 0.001), and the intra-operative blood loss was increased 460 ml (100 to 1100) versus 320 ml (50 to 850) (p < 0.001), but there were no differences between the groups regarding any complications or mortality. There were no dislocations in either group. Hip function measured by the Harris hip score was significantly better in the total hip replacement group at both follow-up periods (p = 0.011 and p < 0.001, respectively). The health-related quality of life measure was in favour of the total hip replacement group but did not reach statistical significance (p = 0.818 at four months and p = 0.636 at 12 months).

These results indicate that a total hip replacement provides better function than a bipolar hemiarthroplasty as soon as one year post-operatively, without increasing the complication rate. We recommend total hip replacement as the primary treatment for this group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 619 - 619
1 May 2004
KISH G HANGODY L


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 233 - 238
1 Mar 1992
Albrektsson B Carlsson L Freeman M Herberts P Ryd L

We studied the effect of a layer of cement placed under the tibial component of Freeman-Samuelson total knee prostheses with a metal back and an 80 mm intramedullary stem, using roentgen stereophotogrammetry to measure the migration of the tibial component during one year in 13 uncemented and 16 cemented knees. The addition of cement produced a significant reduction in migration at one year, from a mean of 1.5 mm to one of 0.5 mm (p less than 0.01), including a significant reduction in pure subsidence. One year postoperatively the clinical results were similar between the groups, but, at three years, one uncemented knee had required revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 118 - 121
1 Jan 1992
Hede A Larsen E Sandberg H

Two hundred patients with a meniscal lesion were peroperatively allocated to partial or total meniscectomy in a random manner. The results were compared at one year and at 6.3 to 9.8 years (median 7.8). After one year more patients with partial meniscectomy (90%) than with total meniscectomy (80%) had no complaints. At the later review these figures were 62% and 52%, respectively (p = 0.18). However, patients with partial meniscectomy had higher functional scores. The deterioration in function between the first review and the second showed no significant difference in the two treatment groups. The incidence of mediolateral instability rose from 8% to 47% and was more frequent after total than after partial meniscectomy. Between the two reviews the radiological signs of knee degeneration increased with no difference between the two treatment groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 591 - 594
1 Jul 1991
Slagis S Benjamin J Volz R Giordano G

We undertook a prospective controlled clinical trial of 109 patients to determine whether postoperative blood salvage in patients undergoing total hip or knee arthroplasty decreased the need for transfusion with banked blood. The average amount of blood collected in our series was 493 ml, most of which was collected in the first four postoperative hours. In patients undergoing bilateral total knee arthroplasty, there was a 54% reduction in banked blood utilisation. None of our patients developed adverse effects from the reinfused material. The cost of collecting and processing wound drainage using the Haemolite cell washer was $175 per patient, regardless of the volume processed, compared to $125 for a unit of banked blood. By reducing the requirement for homologous transfusion, blood salvage diminishes the risks of transmission of HIV and hepatitis viruses. In those cases where the equivalent of two units of blood are reinfused, blood salvage saves money. However, due to the small amounts of blood collected in unilateral hip or knee arthroplasty, we do not recommend its routine application in these cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1084 - 1084
1 Sep 2003
ANAND S HARRISON JWK BUCH KA


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 932 - 932
1 Aug 2003
THIENPONT E


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 464 - 465
1 Apr 2003
DE ROECK N


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 521 - 524
1 Jul 1994
MacMahon S Rodgers A Collins R Farrell B



The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 433 - 434
1 Mar 2005
VANDERESTRAETEN L BINNS MS


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 619 - 620
1 May 2003
HIDALGO-OVEJERO AM GARCIA-MATA S MARTINEZ-GRANDE M OTERMIN-MAYA I


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1535 - 1536
1 Nov 2008
BOUTROS IR LANDHAM PR BROWN RR GOSALI HS


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 330 - 334
1 Mar 1991
Bridle S Patel A Bircher M Calvert P

We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups.