We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were ≤ 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of
There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a
Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation. This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final
We report 60 synovectomies of the knee in 51 children with juvenile chronic arthritis. Synovitis had been present for an average of 5 years and the average age at operation was 13 years. Results were evaluated in terms of pain, knee movement, relapse of synovitis and radiological change during a
We report a multicentre prospective consecutive
study assessing the long-term outcome of the proximally hydroxyapatite
(HA)-coated ABG II monobloc femoral component in a series of 1148
hips in 1053 patients with a mean age at surgery of 64.77 years
(22 to 80) at a mean
1. A five-year
Total arthroplasty was performed on 21 congenitally dislocated hips in 18 women. In all cases the femoral head was dislocated cranially at least one-fifth of the height of the pelvis. The components were both cemented, the acetabulum being replaced to its original position. The acetabular roof was reconstructed by bone graft in 13 hips, and trochanteric osteotomy was done in 18 hips. The patients were assessed at a median
Thirty patients with mild idiopathic scoliosis were reviewed between 7 and 17 years after spinal maturity. These patients were not treated surgically because they were cosmetically acceptable, and unlikely to progress further. Standardised radiographs taken at spinal maturity and at review were comparable, so any change represented true progression in a fully mature spine. There was an increase of lateral curvature in 60 per cent of the patients; this was small and always under 10 degrees. No change was seen in rotation. Lateral curves over 30 degrees, with rotation of 25 degrees or more, were found to be almost twice as likely to progress. It is suggested that caution should be exercised in leaving these curves untreated, and
Hyperphosphatasia, or hereditary bone dysplasia with hyperphosphatasaemia, is a rare genetic disorder which is characterised by failure to transform woven into lamellar bone. Clinical, radiological and histological features establish the diagnosis, fractures, deformities, diffuse sclerosis on radiographs and high serum alkaline phosphatase being characteristic. We report the case of a 27-year-old man with
The primary aim of this independent prospective randomised trial
was to compare serum metal ion levels for ceramic-on-metal (CoM)
and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty
(THA). Our one-year results demonstrated elevation in metal ion
levels above baseline with no significant difference between the
CoM and MoM groups. This paper reviews the five-year data. The implants used in each patient differed only in respect to
the type of femoral head (ceramic or metal). At five-year follow-up
of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available
for comparison.Aims
Patients and Methods
Van Nes rotationplasty may be used for patients
with congenital proximal focal femoral deficiency (PFFD). The lower
limb is rotated to use the ankle and foot as a functional knee joint
within a prosthesis. A small series of cases was investigated to
determine the long-term outcome. At a mean of 21.5 years (11 to
45) after their rotationplasty, a total of 12 prosthetic patients
completed the Short-Form (SF)-36, Faces Pain Scale-Revised, Harris
hip score, Oswestry back pain score and Prosthetic Evaluation Questionnaires,
as did 12 age- and gender-matched normal control participants. A
physical examination and gait analysis, computerised dynamic posturography
(CDP), and timed ‘Up &
Go’ testing was also completed. Wilcoxon
Signed rank test was used to compare each PFFD patient with a matched
control participant with false discovery rate of 5%. There were no differences between the groups in overall health
and well-being on the SF-36. Significant differences were seen in
gait parameters in the PFFD group. Using CDP, the PFFD group had
reduced symmetry in stance, and reduced end point and maximum excursions. Patients who had undergone Van Nes rotationplasty had a high
level of function and quality of life at long-term
This single-blinded randomised controlled trial
investigated whether one design of mobile-bearing (MB) total knee replacement
(TKR) has any advantage over a fixed-bearing (FB) design on long-term
fixation as measured by radiostereometry. The amount of wear underneath
the mobile bearing was also evaluated. A series of 42 knees was randomised
to MB or FB tibial components with appropriate polyethylene inserts
and followed for between ten and 12 years, or until the death of
the patient. The polyethylene in the MB group was superior in that
it was gamma-irradiated in inert gas and was calcium-stearate free;
the polyethylene in the FB group was gamma-irradiated in air and
contained calcium stearate. In theory this should be advantageous
to the wear rate of the MB group. At final
We report the long-term clinical
A retrospective review of medial compartment arthroplasty in 22 patients (22 knees) is reported. The operations were performed between 1973 and 1978. Eighty-six per cent were rated good or excellent using the knee rating system devised by the Hospital for Special Surgery, New York. Excellent or good results were achieved in six patients who had previously had a high tibial osteotomy. At the time of
Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR. A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by >
3°. At 15 years’
Transposition of part of the pes anserinus was used to treat 96 knees in 78 patients with recurrent, habitual or permanent dislocations of the patella. The knees with habitual (48) and permanent (27) dislocations also had extensive release of superolateral contracture. The patients were reviewed at an average
Of 37 consecutive patients suffering from tuberculosis of the lumbosacral spine, 26 were reviewed after an average
Most published randomised controlled trials which
compare the rates of wear of conventional and cross-linked (XL) polyethylene
(PE) in total hip arthroplasty (THA) have described their use with
a cementless acetabular component. . We conducted a prospective randomised study to assess the rates
of penetration of two distinct types of PE in otherwise identical
cemented all-PE acetabular components. . A total of 100 consecutive patients for THA were randomised to
receive an acetabular component which had been either highly XL
then remelted or moderately XL then annealed. . After a minimum of eight years
We reviewed 50 capitellocondylar elbow replacements performed by the lateral approach in 42 rheumatoid patients, at a median
From 1983 to 1985 we performed 114 primary hip replacements in 108 consecutive osteoarthritic patients using a non-cemented RM isoelastic femoral stem. After a mean