Advertisement for orthosearch.org.uk
Results 81 - 100 of 1178
Results per page:
Bone & Joint 360
Vol. 4, Issue 1 | Pages 22 - 24
1 Feb 2015

The February 2015 Shoulder & Elbow Roundup. 360 . looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow


Bone & Joint 360
Vol. 10, Issue 6 | Pages 29 - 32
1 Dec 2021


Bone & Joint 360
Vol. 10, Issue 4 | Pages 31 - 34
1 Aug 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 54 - 61
1 Jan 2005
Sanchez-Sotelo J Morrey BF O’Driscoll SW

We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15). Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04). Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability


Bone & Joint 360
Vol. 10, Issue 3 | Pages 20 - 23
1 Jun 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 620 - 622
1 May 2006
Chalidapong P Sananpanich K Klaphajone J

We compared the quantitative electromyographic activity of the elbow flexors during four exercises (forced inspiration, forced expiration, trunk flexion and attempted elbow flexion), following intercostal nerve transfer to the musculocutaneous nerve in 32 patients who had sustained root avulsion brachial plexus injuries. Quantitative electromyographic evaluation of the mean and maximum amplitude was repeated three times for each exercise. We found that mean and maximum elbow flexor activity was highest during trunk flexion, followed by attempted elbow flexion, forced inspiration and finally forced expiration. The difference between each group was significant (p < 0.001), with the exception of the difference between trunk flexion and attempted elbow flexion. Consequently, we recommend trunk flexion exercises to aid rehabilitation following intercostal nerve transfer


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 805 - 810
1 Jun 2012
Flinkkilä T Kaisto T Sirniö K Hyvönen P Leppilahti J

We assessed the short- to mid-term survival of metallic press-fit radial head prostheses in patients with radial head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with a mean age of 56 years (23 to 85) with acute unstable elbow injuries, including a fracture of the radial head requiring metallic replacement of the radial head, were reviewed retrospectively. Survival of the prosthesis was assessed from the radiographs of 37 patients after a mean follow-up of 50 months (12 to 107). The functional results of 31 patients were assessed using range-of-movement, Mayo elbow performance score (MEPS), Disabilities of the Arm, Shoulder and Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed, nine had been removed because of loosening, and three remained implanted but were loose. The mean time from implantation to loosening was 11 months (2 to 24). Radiolucent lines that developed around the prosthesis before removal were mild in three patients, moderate in one and severe in five. Range of movement parameters and mass grip strength were significantly lower in the affected elbow than in the unaffected side. The mean MEPS score was 86 (40 to 100) and the mean DASH score was 23 (0 to 81). According to RAND-36 scores, patients had more pain and lower physical function scores than normal population values. Loosening of press-fit radial head prostheses is common, occurs early, often leads to severe osteolysis of the proximal radius, and commonly requires removal of the prosthesis


Bone & Joint 360
Vol. 10, Issue 5 | Pages 29 - 32
1 Oct 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1158 - 1162
1 Nov 2004
Park MJ Kim HG Lee JY

Surgical release of the elbow was performed in 27 patients with post-traumatic stiffness at a mean of 14.5 months after the initial injury. The outcome was related to whether there had been heterotopic ossification, which had occurred in 18 elbows and to whether, if there had been a fracture, it had involved the articular surface, which had occurred in 13 elbows. The final range of movement and the ratio of desired gain in each group were compared at a mean follow-up period of 22.5 months (12 to 43). The arc of movement of the elbow improved in all patients after the operation. The mean final arc was 110° in those with heterotopic ossification and 86° in those without (p = 0.001). The ratios of desired gain were significantly higher in patients with heterotopic ossification (88.2% vs 54.9%; p < 0.001). There was no significant difference in relation to involvement of the articular surface. Careful assessment of the cause of stiffness is important in order to achieve a satisfactory result from surgery for post-traumatic stiffness of the elbow


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1306 - 1311
1 Nov 2024
Watts AC McDaid C Hewitt C

Aims

A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement.

Methods

A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 19 - 21
1 Dec 2014

The December 2014 Shoulder & Elbow Roundup. 360 . looks at: cuff tears and plexus injury; . corticosteroids and physiotherapy in SAI; diabetes and elbow arthroplasty; distal biceps tendon repairs; shockwave therapy in frozen shoulder; hydrodilation and steroids for adhesive capsulitis; just what do our patients read?; and what happens to that stable radial head fracture?


Bone & Joint 360
Vol. 3, Issue 3 | Pages 25 - 27
1 Jun 2014

The June 2014 Shoulder & Elbow Roundup. 360 . looks at: suprascapular nerve and rotator cuff pathology; anchors in Bankart repair: it’s not what you’ve got, but how you use it; not all shoulder PROMs are equal; reverse shoulder arthroplasty OK in trauma; not all in the mind: frozen shoulder personality debunked; open and arthroscopic repair equivalent in shoulder instability; natural history of olecranon fractures not so bleak?; and resurfacing of the shoulder: a Danish perspective


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1199 - 1202
1 Nov 2024
Watts AC Tennent TD Haddad FS


Bone & Joint 360
Vol. 13, Issue 5 | Pages 8 - 17
1 Oct 2024
Holley J Lawniczak D Machin JT Briggs TWR Hunter J


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 70 - 74
1 Jan 2013
Dattani R Smith CD Patel VR

We investigated the incidence of and risk factors for venous thromboembolism (VTE) following surgery of the shoulder and elbow and assessed the role of thromboprophylaxis in upper limb surgery. All papers describing VTE after shoulder and elbow surgery published in the English language literature before 31 March 2012 were reviewed. A total of 14 papers were available for analysis, most of which were retrospective studies and case series. The incidence of VTE was 0.038% from 92 440 shoulder arthroscopic procedures, 0.52% from 42 261 shoulder replacements, and 0.64% from 4833 procedures for fractures of the proximal humerus (open reduction and internal fixation or hemiarthroplasty). The incidence following replacement of the elbow was 0.26% from 2701 procedures. Diabetes mellitus, rheumatoid arthritis and ischaemic heart disease were identified as the major risk factors. The evidence that exists on thromboprophylaxis is based on level III and IV studies, and we therefore cannot make any recommendations on prophylaxis based on the current evidence. It seems reasonable to adopt a multimodal approach that involves all patients receiving mechanical prophylaxis, with chemical prophylaxis reserved for those who are at high risk for VTE. Cite this article: Bone Joint J 2013;95-B:70–4


Bone & Joint Research
Vol. 13, Issue 5 | Pages 201 - 213
1 May 2024
Hamoodi Z Gehringer CK Bull LM Hughes T Kearsley-Fleet L Sergeant JC Watts AC

Aims

The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA).

Methods

Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1416 - 1421
1 Oct 2010
Qureshi F Draviaraj KP Stanley D

Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1312 - 1320
1 Nov 2024
Hamoodi Z Sayers A Whitehouse MR Rangan A Kearsley-Fleet L Sergeant J Watts AC

Aims

The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes.

Methods

We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 191 - 195
1 Feb 2005
Mighell MA Dunham RC Rommel EA Frankle MA

We present six patients with chronic dislocation of the elbow who were treated by primary semiconstrained total elbow arthroplasty. All were women with a mean age of 65 years (51 to 76), the mean interval between dislocation and surgery was 17 weeks (5 to 52) and the mean follow-up 58 months (24 to 123). The most dramatic improvement was in function. The mean American Shoulder and Elbow Surgeon score was 5.2 times better (p < 0.001) and the mean total range of movement increased from 33° to 121° (p < 0.001) after operation. Three patients developed wear of polyethylene. One required revision for a periprosthetic fracture, and another required a bushing exchange. Primary semiconstrained elbow arthroplasty provides significant, predictable functional improvement. Potential solutions for wear of polyethylene include a different operative technique or design of implant. Despite the high incidence of such wear, total elbow arthroplasty should be considered as a viable treatment option for chronic dislocation of the elbow in elderly patients


Bone & Joint 360
Vol. 2, Issue 5 | Pages 27 - 29
1 Oct 2013

The October 2013 Shoulder & Elbow Roundup. 360 . looks at: Deltoid impairment not necessarily a contra-indication for shoulder arthroplasty; The tricky radiograph; Not so asymptomatic cuff tears; Total shoulder arthroplasty: kinder on the glenoid; Barbotage for calcific tendonitis; What happens to the arthritic glenoid?; Two screws a screw too few?; Sloppy hinge best for elbow arthroplasty