Advertisement for orthosearch.org.uk
Results 81 - 100 of 447
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 904 - 911
1 Jul 2020
Sigmund IK Dudareva M Watts D Morgenstern M Athanasou NA McNally MA

Aims. The aim of this study was to evaluate the diagnostic value of preoperative serum CRP, white blood cell count (WBC), percentage of neutrophils (%N), and neutrophil to lymphocyte ratio (NLR) when using the fracture-related infection (FRI) consensus definition. Methods. A cohort of 106 patients having surgery for suspected septic nonunion after failed fracture fixation were studied. Blood samples were collected preoperatively, and the concentration of serum CRP, WBC, and differential cell count were analyzed. The areas under the curve (AUCs) of diagnostic tests were compared using the z-test. Regression trees were constructed and internally cross-validated to derive a simple diagnostic decision tree. Results. Using the FRI consensus definition, 46 patients (43%) were identified as infected. Sensitivity, specificity, and AUC of CRP were 67% (95% confidence interval (CI) 52% to 80%), 61% (95% CI 47% to 74%), and 0.64 (95% CI 0.54 to 0.74); of WBC count were 17% (95% CI 9% to 31%), 95% (95% CI 86% to 99%), and 0.57 (95% CI 0.50 to 0.62); of %N 13% (95% CI 6% to 26%), 87% (95% CI 76% to 93%), and 0.50 (95% CI 0.43 to 0.56); and of NLR 28% (95% CI 17% to 43%), 80% (95% CI 68% to 88%), and 0.54 (95% CI 0.46 to 0.63), respectively. A better performance of serum CRP was shown in comparison to the leucocyte count (p = 0.006), %N (p < 0.001), and NLR (p = 0.001). A statistically lower serum CRP level was shown in patients with an infection caused by a low virulence microorganism in comparison to high virulence bacteria (p = 0.008). We found that a simple decision tree approach using only low serum neutrophils (< 3.615 × 10. 9. /l) and low CRP (< 2.45 mg/l) may allow better identification of aseptic cases. Conclusion. The evaluated serum inflammatory markers showed limited diagnostic value in the preoperative diagnosis of FRI when using the uniform FRI Consensus Definition. Therefore, they should remain as suggestive criteria in diagnosing FRI. Although CRP showed a higher performance in comparison to the other serum markers, it is insufficiently accurate to diagnose a septic nonunion, especially when caused by low virulence microorganisms. Cite this article: Bone Joint J 2020;102-B(7):904–911


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 568 - 572
1 Jul 1998
Tunney MM Patrick S Gorman SP Nixon JR Anderson N Davis RI Hanna D Ramage G

Our aim was to determine if the detection rate of infection of total hip replacements could be improved by examining the removed prostheses. Immediate transfer of prostheses to an anaerobic atmosphere, followed by mild ultrasonication to dislodge adherent bacteria, resulted in the culture of quantifiable numbers of bacteria, from 26 of the 120 implants examined. The same bacterial species were cultured by routine microbiological techniques from only five corresponding tissue samples. Tissue removed from 18 of the culture-positive implants was suitable for quantitative tissue pathology and inflammatory cells were present in all samples. Furthermore, inflammatory cells were present in 87% of tissue samples taken from patients whose implants were culture-negative. This suggests that these implants may have been infected by bacteria which were not isolated by the techniques of culture used. The increased detection of bacteria from prostheses by culture has improved postoperative antibiotic therapy and should reduce the need for further revision


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 490 - 494
1 May 2003
Der Tavitian J Ong SM Taub NA Taylor GJS

We randomly allocated 50 total knee replacements to scrub teams wearing body-exhaust suits (BES) or Rotecno occlusive clothing. The effectiveness of the clothing was assessed using air and wound bacterial counts. Bacteria were recovered from 62% of wounds (64% BES, 60% Rotecno). The mean air count was 0.5 CFU/ m. 3. with BES and 1.0 CFU/m. 3. with Rotecno (p = 0.014). The mean wound counts were 14 bacteria/wound with BES and eight bacteria/wound with Rotecno (p = 0.171). There was no correlation between the air and wound counts (r = −0.011, Spearman’s). The higher air counts suggest that Rotecno occlusive clothing is less effective than BES, but wounds were equally contaminated with both types of clothing suggesting that at very low levels of air contamination the contribution of bacteria to the wound from the air is irrelevant. Even doubling the air counts from 0.5 to 1.0 CFU/m. 3. had no detectable effect on the wound. This allows a reassessment to be made of other sources of contamination the effect of which would previously have been overwhelmed by contamination from air


Bone & Joint 360
Vol. 12, Issue 3 | Pages 40 - 41
1 Jun 2023

The June 2023 Research Roundup360 looks at: Characterizing recurrent infections after one-stage revision for periprosthetic joint infection of the knee; Predicted waiting times for orthopaedic surgery: an urgent need to address the deficit in capacity; Vascular impulse technology versus elevation for reducing the swelling of upper and lower limb joint fractures; Desperate patients will accept higher risks; How long does it take to find a positive culture in periprosthetic joint infection?


Bone & Joint 360
Vol. 12, Issue 4 | Pages 41 - 42
1 Aug 2023

The August 2023 Research Roundup360 looks at: Can artificial intelligence improve the readability of patient education materials?; What is the value of radiology input during a multidisciplinary orthopaedic oncology conference?; Periprosthetic joint infection in patients with multiple arthroplasties; Orthopedic Surgery and Anesthesiology Surgical Improvement Strategies Project - Phase III outcomes; Knot tying in arthroplasty and arthroscopy causes lesions to surgical gloves: a potential risk of infection; Vascular calcification of the ankle in plain radiographs equals diabetes mellitus?


Bone & Joint 360
Vol. 12, Issue 5 | Pages 34 - 36
1 Oct 2023

The October 2023 Spine Roundup360 looks at: Cutting through surgical smoke: the science of cleaner air in spinal operations; Unlocking success: key factors in thoracic spine decompression and fusion for ossification of the posterior longitudinal ligament; Deep learning algorithm for identifying cervical cord compression due to degenerative canal stenosis on radiography; Surgeon experience influences robotics learning curve for minimally invasive lumbar fusion; Decision-making algorithm for the surgical treatment of degenerative lumbar spondylolisthesis of L4/L5; Response to preoperative steroid injections predicts surgical outcomes in patients undergoing fusion for isthmic spondylolisthesis.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 8 - 12
1 Apr 2024
Craxford S


Bone & Joint 360
Vol. 12, Issue 2 | Pages 34 - 36
1 Apr 2023

The April 2023 Trauma Roundup360 looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?; Tibial plateau fractures: continuous passive motion approves range of motion; Lisfranc fractures: to fuse or not to fuse, that is the question; Is hardware removal after clavicle fracture plate fixation beneficial?; Fixation to coverage in Grade IIIB open fractures – what’s the time window?; Nonoperative versus locking plate fixation in the proximal humerus; Retrograde knee nailing or lateral plate for distal femur fractures?


Bone & Joint 360
Vol. 12, Issue 2 | Pages 6 - 9
1 Apr 2023
O’Callaghan J Afolayan J Ochieng D Rocos B


Bone & Joint 360
Vol. 13, Issue 3 | Pages 42 - 45
3 Jun 2024

The June 2024 Children’s orthopaedics Roundup360 looks at: Proximal femoral unicameral bone cysts: is ESIN the answer?; Hybrid-mesh casts in the conservative management of paediatric supracondylar humeral fractures: a randomized controlled trial; Rate and risk factors for contralateral slippage in adolescents treated for slipped capital femoral epiphysis; CRP predicts the need to escalate care after initial debridement for musculoskeletal infection; Genu valgum in paediatric patients presenting with patellofemoral instability; Nusinersen therapy changed the natural course of spinal muscular atrophy type 1: what about spine and hip?; The necessity of ulnar nerve exploration and translocation in open reduction of medial humeral epicondyle fractures in children.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 97 - 98
1 Feb 2023
Farhan-Alanie OM Kennedy IW Meek RMD Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1426 - 1430
1 Dec 2024
Warne CN Ryan S Yu E Osmon DR Berry DJ Abdel MP

Aims

Cutibacterium acnes (C. acnes; previously known as Propionibacterium acnes or P. acnes) periprosthetic hip and knee infections are under-reported. While culture contamination with C. acnes occurs, true infections are important to recognize and treat. We sought to describe the demographics and treatment outcomes of patients with C. acnes periprosthetic joint infections (PJIs) of the hip and knee.

Methods

Patients with C. acnes PJI between January 2005 and December 2018 were retrospectively reviewed utilizing the institutional total joint registry. Patients with monomicrobial PJI and two or more positive cultures were considered to have true C. acnes PJI. Patients with polymicrobial infection or with only one positive culture were excluded. This resulted in 35 PJIs (21 hips and 14 knees); the patients’ mean age was 63 years (35 to 84) and 15 (43%) were female. Mean follow-up was five years (1 to 14).


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 887 - 891
1 Sep 2024
Whyte W Thomas AM

The critical relationship between airborne microbiological contamination in an operating theatre and surgical site infection (SSI) is well known. The aim of this annotation is to explain the scientific basis of using settle plates to audit the quality of air, and to provide information about the practicalities of using them for the purposes of clinical audit. The microbiological quality of the air in most guidance is defined by volumetric sampling, but this method is difficult for surgical departments to use on a routine basis. Settle plate sampling, which mimics the mechanism of deposition of airborne microbes onto open wounds and sterile instruments, is a good alternative method of assessing the quality of the air. Current practice is not to sample the air in an operating theatre during surgery, but to rely on testing the engineering systems which deliver the clean air. This is, however, not good practice and microbiological testing should be carried out routinely during operations as part of clinical audit.

Cite this article: Bone Joint J 2024;106-B(9):887–891.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 15 - 18
1 Feb 2025

The February 2025 Hip & Pelvis Roundup360 looks at: Postoperative periprosthetic femoral fractures after hip arthroplasty: quantifying the other half of the picture; Hip arthroscopy in patients with borderline dysplasia: how do we know when it will not work?; The morbidly obese patient remains a challenge for arthroplasty surgeons; Unexpected positive cultures in aseptic revision hip and knee arthroplasty: does it make a difference?; Failed spinal anaesthesia in hip and knee arthroplasty surgery; Clinical failure of femoral neck fracture is associated with varus necks; Navigating the angles: how variations in femoral and acetabular versions influence hip pain and treatment; High-tech or hands-on? Similar outcomes in direct anterior total hip arthroplasty.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1193 - 1195
1 Nov 2022
Rajput V Meek RMD Haddad FS

Periprosthetic joint infection (PJI) remains an extremely challenging complication. We have focused on this issue more over the last decade than previously, but there are still many unanswered questions. We now have a workable definition that everyone should align to, but we need to continue to focus on identifying the organisms involved. Surgical strategies are evolving and care is becoming more patient-centred. There are some good studies under way. There are, however, still numerous problems to resolve, and the challenge of PJI remains a major one for the orthopaedic community. This annotation provides some up-to-date thoughts about where we are, and the way forward. There is still scope for plenty of research in this area.

Cite this article: Bone Joint J 2022;104-B(11):1193–1195.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims

Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI.

Methods

The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1176 - 1181
1 Oct 2024
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Nietosvaara Y Helenius I

Aims

Closed suction subfascial drainage is widely used after instrumented posterior spinal fusion in patients with a spinal deformity. The aim of this study was to determine the effect of this wound drainage on the outcomes in patients with adolescent idiopathic scoliosis (AIS). This was a further analysis of a randomized, multicentre clinical trial reporting on patients after posterior spinal fusion using segmental pedicle screw instrumentation. In this study the incidence of deep surgical site infection (SSI) and chronic postoperative pain at two years’ follow-up are reported.

Methods

We conducted a randomized, multicentre clinical trial on adolescents undergoing posterior spinal fusion for AIS using segmental pedicle screw instrumentation. A total of 90 consecutive patients were randomized into a ‘drain’ or ‘no drain’ group at the time of wound closure, using the sealed envelope technique (1:1). The primary outcomes in the initial study were the change in the level of haemoglobin in the blood postoperatively and total blood loss. A secondary outcome was the opioid consumption immediately after surgery. The aim of this further study was to report the rate of deep SSI and persistent postoperative pain, at two years' follow-up.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 32 - 35
1 Feb 2024

The February 2024 Trauma Roundup360 looks at: Posterior malleolus fractures: what about medium-sized fragments?; Acute or delayed total hip arthroplasty after acetabular fracture fixation?; Intrawound antibiotics reduce the risk of deep infections in fracture fixation; Does the VANCO trial represent real world patients?; Can a restrictive transfusion protocol be effective beyond initial resuscitation?; What risk factors result in avascular necrosis of the talus?; Pre-existing anxiety and mood disorders have a role to play in complex regional pain syndrome; Three- and four-part proximal humeral fractures at ten years.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims

Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation.

Methods

A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707).


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 372 - 379
1 Apr 2024
Straub J Staats K Vertesich K Kowalscheck L Windhager R Böhler C

Aims

Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections.

Methods

We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated.