This systematic review examines the current literature regarding surgical techniques for restoring articular cartilage in the hip, from the older microfracture techniques involving perforation to the subchondral bone, to adaptations of this technique using nanofractures and scaffolds. This review discusses the autologous and allograft transfer systems and the autologous matrix-induced chondrogenesis (AMIC) technique, as well as a summary of the previously discussed techniques, which could become common practice for restoring articular cartilage, thus reducing the need for total hip arthroplasty. Using the
Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used. A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.Aims
Materials and Methods
Arthroscopically controlled fracture reduction in combination
with percutaneous screw fixation may be an alternative approach
to open surgery to treat talar neck fractures. The purpose of this
study was thus to present preliminary results on arthroscopically
reduced talar neck fractures. A total of seven consecutive patients (four women and three men,
mean age 39 years (19 to 61)) underwent attempted surgical treatment
of a closed Hawkins type II talar neck fracture using arthroscopically
assisted reduction and percutaneous screw fixation. Functional and
radiological outcome were assessed using plain radiographs, as well
as weight-bearing and non-weight-bearing CT scans as tolerated.
Patient satisfaction and pain sensation were also recorded.Aims
Patients and Methods
Surface replacement arthroplasty (SRA), compared with traditional total hip arthroplasty (THA), is more expensive and carries unique concern related to metal ions production and hypersensitivity. Additionally, SRA is a more demanding procedure with a decreased margin for error compared with THA. To justify its use, SRA must demonstrate comparable component survival and some clinical advantages. We therefore performed a systematic literature review to investigate the differences in complication rates, patient-reported outcomes, stress shielding, and hip biomechanics between SRA and THA. A systematic review of the literature was completed using MEDLINE and EMBASE search engines. Inclusion criteria were level I to level III articles that reported clinical outcomes following primary SRA compared with THA. An initial search yielded 2503 potential articles for inclusion. Exclusion criteria included review articles, level IV or level V evidence, less than one year’s follow-up, and previously reported data. In total, 27 articles with 4182 patients were available to analyze.Aims
Materials and Methods
Hip and groin injuries are common in athletes
who take part in high level sports. Adductor muscle tendon injuries represent
a small but important number of these injuries. Avulsion of the
tendons attached to the symphysis pubis has previously been described:
these can be managed both operatively and non-operatively. We describe
an uncommon variant of this injury, namely complete avulsion of
the adductor sleeve complex: this includes adductor longus, pectineus
and rectus abdominis. We go on to describe a surgical technique
which promotes a full return to the pre-injury level of sporting
activity. Over a period of ten years, 15 high-level athletes with an MRI-confirmed
acute adductor complex avulsion injury (six to 34 days old) underwent
surgical repair. The operative procedure consisted of anatomical
re-attachment of the avulsed tissues in each case and mesh reinforcement
of the posterior inguinal wall in seven patients. All underwent a
standardised rehabilitation programme, which was then individualised
to be sport-specific. One patient developed a superficial wound infection, which was
successfully treated with antibiotics. Of the 15 patients, four
complained of transient local numbness which resolved in all cases.
All patients (including seven elite athletes) returned to their
previous level of participation in sport. Cite this article:
The aim of this study was to report the outcome of the non-operative
treatment of high-grade posterior cruciate ligament (PCL) injuries,
particularly Hughston grade III injuries, which have not previously
been described. This was a prospective study involving 46 consecutive patients
who were athletes with MRI-confirmed isolated PCL injuries presenting
within four weeks of injury. All had Hughston grade II (25 athletes)
or III (21 athletes) injuries. Our non-operative treatment regimen
involved initial bracing, followed by an individualised rehabilitation
programme determined by the symptoms and physical signs. The patients
were reviewed until they had returned to sports-specific training,
and were reviewed again at a mean of 5.2 years (3 to 9).Aims
Patients and Methods
The December 2014 Hip &
Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection
In this systematic review, our aim was to explore
whether or not patients are able to return to athletic activity
following lower limb joint replacement. We also investigated any evidence
as to whether participation in athletic activity post-joint replacement
increases complications and reduces implant survival. A PubMed, Embase and Sports Discus search was performed using
the MeSH terms ‘Sport’, ‘Athletic’, ‘Athlete’, ‘Physical’, ‘Activity’,
‘Arthroplasty’, ‘Total Hip Replacement’, ‘Hip Resurfacing’, ‘Total
Knee Replacement’, ‘Unicompartmental Knee Replacement’ and ‘Unicondylar
Knee Replacement’. From this search, duplications were excluded,
the remaining abstracts were reviewed and any unrelated to the search
terms were excluded. The remaining abstracts had their full papers
reviewed. Following joint replacement, participation in sporting activity
is common principally determined by pre-operative patient activity
levels, BMI and patient age. The type of joint replaced is of less
significance. Total time spent performing activity does not change
but tends to be at a lower intensity. There is little evidence in