The Control of Infection Committee at a specialist orthopaedic hospital prospectively collected data on all episodes of bacteriologically-proven deep infection arising after primary hip and knee replacements over a 15-year period from 1987 to 2001. There were 10 735 patients who underwent primary hip or knee replacement. In 34 of 5947 hip replacements (0.57%) and 41 of 4788 knee replacements (0.86%) a deep infection developed. The most common infecting micro-organism was coagulase-negative staphylococcus, followed by Of the infections, 29% (22) arose in the first three months following surgery, 35% between three months and one year (26), and 36% (27) after one year. Most cases were detected early and treated aggressively, with eradication of the infection in 96% (72). There was no significant change in the infection rate or type of infecting micro-organism over the course of this study. These results set a benchmark, and importantly emphasise that only 64% of peri-prosthetic infections arise within one year of surgery. These results also illustrate the advantages of conducting joint replacement surgery in the isolation of a specialist hospital.
We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up. Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain. Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.