The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 578 - 581
1 May 2015
Rolfson O Malchau H

The limitations and benefits of patient-reported outcome measures, in defining the merits of arthroplasty surgery, are discussed. Cite this article: Bone Joint J 2015;97-B:578–81


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 920 - 923
1 Jul 2008
Wylde V Blom A Dieppe P Hewlett S Learmonth I

Our aim was to determine the pre-operative sporting profiles of patients undergoing primary joint replacement and to establish if they were able to return to sport after surgery. A postal survey was completed by 2085 patients between one and three years after operation. They had undergone one of five operations, namely total hip replacement, hip resurfacing, total knee replacement, unicompartmental knee replacement or patellar resurfacing. In the three years before operation 726 (34.8%) patients were participating in sport, the most common being swimming, walking and golf. A total of 446 (61.4%) had returned to their sporting activities by one to three years after operation and 192 (26.4%) were unable to do so because of their joint replacement, with the most common reason being pain. The largest decline was in high-impact sports including badminton, tennis and dancing. After controlling for the influence of age and gender, there was no significant difference in the rate of return to sport according to the type of operation


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 889 - 890
1 Aug 2019
Haddad FS Masri BA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1015 - 1018
1 Aug 2007
Wroblewski BM Siney PD Fleming PA

We studied survival to 38 years after Charnley low-friction arthroplasty of the hip. We used revision as an end-point, while adopting a policy of regular follow-up and early revision for radiological changes alone if indicated. Between November 1962 and June 2005, 22 066 primary low-friction arthroplasties (17 409 patients) had been performed at Wrightington Hospital by more than 330 surgeons. By June 2006, 1001 (4.5%) hips had been revised and 1490 patients (2662 hips, 12%) had died. At 31 years, where a minimum of 40 hips were still attending follow-up, survival with revision for infection as an endpoint was 95%, for dislocation 98%, for a fractured stem 88.6%, for a loose stem 72.5% and for a loose acetabular component 53.7%. Wear and loosening of the ultra-high-molecular-weight polyethylene acetabular component were the main long-term problems. We conclude that regular follow-up after hip replacement is essential and that all operative findings should be recorded at revision


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 1 | Pages 53 - 60
1 Feb 1949
Speed JS Trout PC

1. Arthroplasty of the knee joint should be performed only in carefully selected cases. Criteria for the operation are outlined. 2. In our experience, 70 per cent. of properly selected patients secure good or fair results. An additional 12 per cent., whose anatomical or functional results were classified as poor, preferred the movement which had been gained to ankylosis of the joint. 3. The major functional adaptation of the knee joint takes place during the first five years after arthroplasty. Several patients who had a poor range of movement after one or two years developed an excellent range by the end of five years. 4. Instability, when present, usually became apparent within the first five years. 5. Joints which were still stable at the end of five years usually remained so over a long period of time. Four patients have been traced for twenty to twenty-five years, and three have been traced for over twenty-five years. 6. Since the incidence of ankylosis of the knee joint from gonococcal and pyogenic infections has been reduced by the use of antibiotics, fewer patients are suitable subjects for arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 2 | Pages 199 - 208
1 May 1953
Adams JC

1. The unreliable results of the conventional cup arthroplasty are attributed to mechanical imperfections in the reconstructed joint. 2. If its reliability can be improved, there will remain a place for cup arthroplasty, which, in relatively young and active patients, offers advantages over prosthetic replacement arthroplasty. 3. A technique of concentric cup arthroplasty is described. The new joint is shaped with precision to exact dimensions and lined with a cup designed to ensure stability, concentric movement and a uniform clearance between the moving parts. 4. The results so far are encouraging and justify continued clinical trial


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 406 - 412
1 Mar 2010
Leonardsson O Sernbo I Carlsson Å åkesson K Rogmark C

In a series of 450 patients over 70 years of age with displaced fractures of the femoral neck sustained between 1995 and 1997 treatment was randomised either to internal fixation or replacement. Depending on age and level of activity the latter was either a total hip replacement or a hemiarthroplasty. Patients who were confused or bed-ridden were excluded, as were those with rheumatoid arthritis. At ten years there were 99 failures (45.6%) after internal fixation compared with 17 (8.8%) after replacement. The rate of mortality was high at 75% at ten years, and was the same in both groups at all times. Patient-reported pain and function were similar in both groups at five and ten years. Those with successfully healed fractures had more hip pain and reduction of mobility at four months compared with patients with an uncomplicated replacement, and they never attained a better outcome than the latter patients regarding pain or function. Primary replacement gave reliable long-term results in patients with a displaced fracture of the femoral neck


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1513 - 1520
1 Nov 2009
Sewell MD Spiegelberg BGI Hanna SA Aston WJS Bartlett W Blunn GW David LA Cannon SR Briggs TWR

We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant bone tumour. In 22 patients this was performed as a primary procedure following total femoral resection for malignant disease. Revision to a total femoral replacement was required in 11 patients following failed segmental endoprosthetic or allograft reconstruction. There were 33 patients with primary malignant tumours, and three had metastatic lesions. The mean age of the patients was 31 years (5 to 68). The mean follow-up was 4.2 years (9 months to 16.4 years). At five years the survival of the implants was 100%, with removal as the endpoint and 56% where the endpoint was another surgical intervention. At five years the patient survival was 32%. Complications included dislocation of the hip in six patients (18%), local recurrence in three (9%), peri-prosthetic fracture in two and infection in one. One patient subsequently developed pulmonary metastases. There were no cases of aseptic loosening or amputation. Four patients required a change of bushings. The mean Musculoskeletal Tumour Society functional outcome score was 67%, the mean Harris Hip Score was 70, and the mean Oxford Knee Score was 34. Total femoral endoprosthetic replacement can provide good functional outcome without compromising patient survival, and in selected cases provides an effective alternative to amputation


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1050 - 1054
1 Sep 2001
Hicks JL Ribbans WJ Buzzard B Kelley SS Toft L Torri G Wiedel JD York J

Joint replacement in HIV-positive patients remains uncommon, with most experience gained in patients with haemophilia. We analysed retrospectively the outcome of 102 replacement arthroplasties in 73 HIV-positive patients from eight specialist haemophilia centres. Of these, 91 were primary procedures. The mean age of the patients at surgery was 39 years, and the median follow-up was for five years. The overall rate of deep sepsis was 18.7% for primary procedures and 36.3% for revisions. This is a much higher rate of infection than that seen in normal populations. A total of 44% of infections resolved fully after medical and/or surgical treatment. The benefits of arthroplasty in haemophilic patients are well established but the rates of complications are high. As this large study has demonstrated, high rates of infection occur, but survivorship analysis strongly suggests that most patients already diagnosed with HIV infection at the time of surgery should derive many years of symptomatic relief after a successful joint replacement. Careful counselling and education of both patients and healthcare workers before operation are therefore essential


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies. Cite this article: Bone Joint J 2016;98-B:892–900


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 120 - 124
1 Jan 2016
Sculco PK Abdel MP Hanssen AD Lewallen DG

The treatment of bone loss in revision total knee arthroplasty has evolved over the past decade. While the management of small to moderate sized defects has demonstrated good results with a variety of traditional techniques (cement and screws, small metal augments, impaction bone grafting or modular stems), the treatment of severe defects continues to be problematic. The use of a structural allograft has declined in recent years due to an increased failure rate with long-term follow-up and with the introduction of highly porous metal augments that emphasise biological metaphyseal fixation. Recently published mid-term results on the use of tantalum cones in patients with severe bone loss has reaffirmed the success of this treatment strategy. . Cite this article: Bone Joint J 2016;98-B(1 Suppl A):120–4


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 399 - 403
1 Mar 2011
Griffiths D Gikas PD Jowett C Bayliss L Aston W Skinner J Cannon S Blunn G Briggs TWR Pollock R

Between 1997 and 2007, 68 consecutive patients underwent replacement of the proximal humerus for tumour using a fixed-fulcrum massive endoprosthesis. Their mean age was 46 years (7 to 87). Ten patients were lost to follow-up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumor Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) at a mean follow-up of five years and 11 months (one year to ten years and nine months). The mean MSTS score was 72.3% (53.3% to 100%) and the mean TESS was 77.2% (58.6% to 100%). Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This subgroup had a mean MSTS score of 77.7% and a mean TESS of 80.0%. The dislocation rate for the original prosthesis was 25.9; none of the patients with the new liner had a dislocation at a mean of 14.5 months (12 to 18). Endoprosthetic replacement for tumours of the proximal humerus using this prosthesis is a reliable operation yielding good results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with a new constrained humeral liner, which reduces the risk of dislocation


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 14 - 20
1 Jan 2016
Zywiel MG Cherian JJ Banerjee S Cheung AC Wong F Butany J Gilbert C Overgaard C Syed K Jacobs JJ Mont MA

As adverse events related to metal on metal hip arthroplasty have been better understood, there has been increased interest in toxicity related to the high circulating levels of cobalt ions. However, distinguishing true toxicity from benign elevations in cobalt levels can be challenging. The purpose of this review is to examine the use of cobalt alloys in total hip arthroplasty, to review the methods of measuring circulating cobalt levels, to define a level of cobalt which is considered pathological and to review the pathophysiology, risk factors and treatment of cobalt toxicity. To the best of our knowledge, there are 18 published cases where cobalt metal ion toxicity has been attributed to the use of cobalt-chromium alloys in hip arthroplasty. Of these cases, the great majority reported systemic toxic reactions at serum cobalt levels more than 100 μg/L. This review highlights some of the clinical features of cobalt toxicity, with the goal that early awareness may decrease the risk factors for the development of cobalt toxicity and/or reduce its severity. Take home message: Severe adverse events can arise from the release of cobalt from metal-on-metal arthroplasties, and as such, orthopaedic surgeons should not only be aware of the presenting problems, but also have the knowledge to treat appropriately. Cite this article: Bone Joint J 2016;98-B:14–20


Bone & Joint Research
Vol. 7, Issue 5 | Pages 351 - 356
1 May 2018
Yeoman TFM Clement ND Macdonald D Moran M

Objectives. The primary aim of this study was to assess the reproducibility of the recalled preoperative Oxford Hip Score (OHS) and Oxford Knee Score (OKS) one year following arthroplasty for a cohort of patients. The secondary aim was to assess the reliability of a patient’s recollection of their own preoperative OHS and OKS one year following surgery. Methods. A total of 335 patients (mean age 72.5; 22 to 92; 53.7% female) undergoing total hip arthroplasty (n = 178) and total knee arthroplasty (n = 157) were prospectively assessed. Patients undergoing hip and knee arthroplasty completed an OHS or OKS, respectively, preoperatively and were asked to recall their preoperative condition while completing the same score one year after surgery. Results. A mean difference of 0.04 points (95% confidence intervals (CI) -15.64 to 15.72, p = 0.97) between the actual and the recalled OHS was observed. The mean difference in the OKS was 1.59 points (95% CI -11.57 to 14.75, p = 0.10). There was excellent reliability for the ‘average measures’ intra-class correlation for both the OHS (r = 0.802) and the OKS (r = 0.772). However, this reliability was diminished for the individuals OHS (r = 0.670) and OKS (r = 0.629) using single measures intra-class correlation. Bland–Altman plots demonstrated wide variation in the individual patient’s ability to recall their preoperative score (95% CI ± 16 for OHS, 95% CI ± 13 for OKS). Conclusion. Prospective preoperative collection of OHS and OKS remains the benchmark. Using recalled scores one year following hip and knee arthroplasty is an alternative when used to assess a cohort of patients. However, the recall of an individual patient’s preoperative score should not be relied upon due to the diminished reliability and wide CI. Cite this article: T. F. M. Yeoman, N. D. Clement, D. Macdonald, M. Moran. Recall of preoperative Oxford Hip and Knee Scores one year after arthroplasty is an alternative and reliable technique when used for a cohort of patients. Bone Joint Res 2018;7:351–356. DOI: 10.1302/2046-3758.75.BJR-2017-0259.R1


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1642 - 1647
1 Dec 2016
Badge R Kailash K Dickson DR Mahalingam S Raza A Birch A Nuttall D Murali SR Hayton MJ Talwalkar S Watts AC Trail IA

Aims. The aims of this study were to evaluate the clinical and radiological outcomes of the Universal-2 total wrist arthroplasty (TWA) in patients with rheumatoid arthritis. Patients and Methods. This was a retrospective review of all 95 Universal-2 TWAs which were performed in our institution between 2003 to 2012 in patients with rheumatoid arthritis. A total of six patients were lost to follow-up and two died of unrelated causes. A total of ten patients had bilateral procedures. Accordingly, 75 patients (85 TWAs) were included in the study. There were 59 women and 16 men with a mean age of 59 years (26 to 86). The mean follow-up was 53 months (24 to 120). Clinical assessment involved recording pain on a visual analogue score, range of movement, grip strength, the Quick Disabilities of the Arm, Shoulder and Hand (DASH) and Wrightington wrist scores. Any adverse effects were documented with particular emphasis on residual pain, limitation of movement, infection, dislocation and the need for revision surgery. Radiographic assessment was performed pre-operatively and at three, six and 12 months post-operatively, and annually thereafter. Arthroplasties were assessed for distal row intercarpal fusion and loosening. Radiolucent zones around the components were documented according to a system developed at our institution. Results. The mean worst pain was 8.1 (3 to 10) pre-operatively and 5.4 (0 to 10) at latest follow-up (p <  0.001). Movements were preserved with mean dorsiflexion of 29. o . (0. o. to 70. o. ) and palmar flexion of 21. o. (0. o. to 50. o. ). The mean grip strength was 4.8 kg (1.7 to 11.5) pre-operatively and 10 kg (0 to 28) at final follow-up (p < 0.001). The mean QuickDASH and Wrightington wrist scores improved from 61 (16 to 91) to 46 (0 to 89) and 7.9 (1.8 to 10) to 5.7 (0 to 7.8) (p <  0.001). A total of six patients (7%) had major complications; three required revision arthroplasty and three an arthrodesis. The Kaplan-Meier probability of survival using removal of the components as the endpoint was 91% at 7.8 years (95% confidence interval 84 to 91). Conclusion. The Universal-2 TWA is recommended for use in patients with rheumatoid arthritis. Cite this article: Bone Joint J 2016;98-B:1642–7


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 867 - 874
1 Jul 2018
Makarewich CA Anderson MB Gililland JM Pelt CE Peters CL

Aims. For this retrospective cohort study, patients aged ≤ 30 years (very young) who underwent total hip arthroplasty (THA) were compared with patients aged ≥ 60 years (elderly) to evaluate the rate of revision arthroplasty, implant survival, the indications for revision, the complications, and the patient-reported outcomes. Patients and Methods. We retrospectively reviewed all patients who underwent primary THA between January 2000 and May 2015 from our institutional database. A total of 145 very young and 1359 elderly patients were reviewed. The mean follow-up was 5.3 years (1 to 18). Logistic generalized estimating equations were used to compare characteristics and the revision rate. Survival was evaluated using Kaplan–Meier curves and hazard rates were created using Cox regression. Results. The overall revision rate was 11% (16/145) in the very young and 3.83% (52/1359) in the elderly groups (odds ratio (OR) 2.58, 95% confidence interval (CI) 1.43 to 4.63). After adjusting for the American Society of Anesthesiologists (ASA) score, gender, and a history of previous surgery in a time-to-event model, the risk of revision remained greater in the very young (adjusted hazard ratio (HR) 2.48, 95% CI 1.34 to 4.58). Survival at ten years was 82% (95% CI, 71 to 89) in the very young and 96% (95% CI, 94 to 97) in the elderly group (p < 0.001). The very young had a higher rate of revision for complications related to metal-on-metal (MoM) bearing surfaces (p < 0.001). At last follow-up, the very young group had higher levels of physical function (p = 0.002), lower levels of mental health (p = 0.001), and similar levels of pain (p = 0.670) compared with their elderly counterparts. Conclusion. The overall revision rate was greater in very young THA patients. This was largely explained by the use of MoM bearings. Young patients with non-MoM bearings had high survivorship with similar complication profiles to patients aged ≥ 60 years. Cite this article: Bone Joint J 2018;100-B:867–74


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 1 | Pages 72 - 77
1 Feb 1975
Devas M Shah V

Link arthroplasty is a system of joint replacement in which the joint is left almost intact with no great removal of bone. It is based on a two-piece self-locking hinge slotted into the metacarpal head and phalangeal shaft. The operation is simple and no special instruments are needed. The preliminary follow-up of fifty-four metacarpo-phalangeal joint replacements showed thirty-five good and sixteen fair results


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 614 - 622
1 Nov 1957
Denham RA Alexander WL

1. Two hundred and eleven cases of arthroplasty of the hip have been studied in an attempt to establish the causes of success and failure by comparing the excellent, good and bad results. 2. The findings suggest that the result of an arthroplasty depends largely upon four factors: the surgical approach to the hip joint, the acetabular roof, the interposition substance, and the early post-operative complications. 3. Some important points in the technique of operation and in the post-operative management are described


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 741 - 744
1 May 2005
Beaulé PE Krismer M Mayrhofer P Wanner S Le Duff M Mattesich M Stoeckl B Amstutz HC Biedermann R

Studies on the migration of an implant may be the only way of monitoring the early performance of metal-on-metal prostheses. The Ein Bild Roentgen Analyse - femoral component analysis (EBRA-FCA) method was adapted to measure migration of the femoral component in a metal-on-metal surface arthroplasty of the hip using standard antero-posterior radiographs. In order to determine the accuracy and precision of this method a prosthesis was implanted into cadaver bones. Eleven series of radiographs were used to perform a zero-migration study. After adjustment of the femoral component to simulate migration of 3 mm the radiographs were repeated. All were measured independently by three different observers. The accuracy of the method was found to be ± 1.6 mm for the x-direction and ± 2 mm for the y-direction (95% percentile). The method was validated using 28 hips with a minimum follow-up of 3.5 years after arthroplasty. Seventeen were sound, but 11 had failed because of loosening of the femoral component. The normal (control) group had a different pattern of migration compared with that of the loose group. At 29.2 months, the control group showed a mean migration of 1.62 mm and 1.05 mm compared with 4.39 mm and 4.05 mm in the failed group, for the centre of the head and the tip of the stem, respectively (p = 0.001). In the failed group, the mean time to migration greater than 2 mm was earlier than the onset of clinical symptoms or radiological evidence of failure, 19.1 versus 32.2 months (p = 0.001) and 24.8 months (p = 0.012), respectively. EBRA-FCA is a reliable and valid tool for measuring migration of the femoral component after surface arthroplasty and can be used to predict early failure of the implant. It may be of value in determining the long-term performance of surface arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 401 - 404
1 Mar 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Jeys LM

We undertook a cemental unipolar proximal femoral endoprosthetic replacement in 131 patients with a mean age of 50 years (2 to 84). Primary malignant tumours were present in 54 patients and 67 had metastatic disease. In addition, eight patients had either lymphoma or myeloma and two had non-oncological disorders. The mean follow-up was 27 months (0 to 180). An acetabular revision was required later in 14 patients, 12 of whom had been under the age of 21 years at the time of insertion of their original prosthesis. The risk of acetabular revision in patients over 21 years of age was 8% at five years compared with 36% in those aged under 21 years. All the unipolar hips in this younger age group required revision within 11 years of the initial operation. We conclude that unipolar replacement should not be used in younger patients and should be avoided in patients with a life expectancy of more than five years