Radiostereometric analysis (RSA) allows an extremely accurate
measurement of early micromotion of components following arthroplasty. In this study, RSA was used to measure the migration of 11 partially
cemented fluted pegged glenoid components in patients with osteoarthritis
who underwent total shoulder arthroplasty using an improved surgical
technique (seven men, four women, mean age 68). Patients were evaluated
clinically using the American Shoulder and Elbow Surgeons (ASES)
and Constant-Murley scores and by CT scans two years post-operatively. Aims
Patients and Methods
Short uncemented humeral stems can preserve humeral
bone stock and facilitate revision surgery but may be prone to malalignment
or loosening, especially when used in reverse total shoulder replacement
(TSR). We undertook a retrospective review of 44 patients with a
mean age of 76 years (59 to 92) who underwent primary reverse TSR
with a short uncemented humeral stem. There were 29 females. The
indications for joint replacement included cuff tear associated
arthropathy (33), avascular necrosis (six), post-traumatic arthritis
(two), and inflammatory arthritis (three). At a mean follow-up of
27 months (24 to 40), pain was rated as mild or none in 43 shoulders
(97.7%). The mean active elevation improved from 54° Cite this article:
We assessed the clinical results, radiographic
outcomes and complications of patients undergoing total shoulder replacement
(TSR) for osteoarthritis with concurrent repair of a full-thickness
rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%)
undergoing TSR for osteoarthritis underwent rotator cuff repair.
The final study group comprised 33 patients with a mean follow-up
of 4.7 years (3 months to 13 years). Tears were classified into small
(10), medium (14), large (9) or massive (0). On a scale of 1 to
5, pain decreased from a mean of 4.7 to 1.7 (p = <
0.0001), the
mean forward elevation improved from 99° to 139° (p = <
0.0001),
and the mean external rotation improved from 20° (0° to 75°) to
49° (20° to 80°) (p = <
0.0001). The improvement in elevation
was greater in those with a small tear (p = 0.03). Radiographic
evidence of instability developed in six patients with medium or
large tears, indicating lack of rotator cuff healing. In all, six
glenoid components, including one with instability, were radiologically
at risk of loosening. Complications were noted in five patients,
all with medium or large tears; four of these had symptomatic instability
and one sustained a late peri-prosthetic fracture. Four patients
(12%) required further surgery, three with instability and one with
a peri-prosthetic humeral fracture. Consideration should be given to performing rotator cuff repair
for stable shoulders during anatomical TSR, but reverse replacement
should be considered for older, less active patients with larger
tears. Cite this article:
Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs. A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p <
0.001), as was resorption of the greater (p <
0.001) and lesser tuberosities (p = 0.009).
Unlinked, linked and convertible total elbow
arthroplasties (TEAs) are currently available. This study is the
first to report the clinical results of the convertible Latitude
TEA. This was a retrospective study of a consecutive cohort of 63
patients (69 primary TEAs) with a mean age of 60 years (23 to 87).
Between 2006 and 2008 a total of 19 men and 50 women underwent surgery.
The mean follow-up was 43 months (8 to 84). The range of movement,
function and pain all improved six months post-operatively and either
continued to improve slightly or reached a plateau thereafter. The
complication rate is similar to that reported for other TEA systems.
No loosening was seen. Remarkable is the disengagement of the radial
head component in 13 TEAs (31%) with a radial head component implanted. Implantation of both the linked and the unlinked versions of
the Latitude TEA results in improvement of function and decreased
pain, and shows high patient satisfaction at mid-term follow-up. Cite this article:
We have previously described the short-term outcome of the use of reverse shoulder arthroplasty in the treatment of acute complex proximal humeral fractures in the elderly. We now report the clinical and radiological outcome of 36 fractures at a mean of 6.6 years (1 to 16). Previously, at a mean follow-up of 6 years (1 to 12) the mean Constant score was 58.5; this was reduced to 53 points with the further follow-up. A total of 23 patients (63%) had radiological evidence of loosening of the glenoid component. Nevertheless, only one patient had aseptic loosening of the baseplate at 12 years’ follow-up. The reduction in the mean Constant score with longer follow-up and the further development of scapular notching is worrying. New developments in design, bearing surfaces and surgical technique, and further follow-up, will determine whether reverse shoulder arthroplasty has a place in the management of complex proximal humeral fractures in the elderly.
The purpose of the present study was to evaluate the impact of
intravenous tranexamic acid on the reduction of blood loss, transfusion
rate, and early post-operative clinical outcome in total shoulder
arthroplasty. A randomised, placebo-controlled trial which included 54 patients
undergoing unilateral primary stemless anatomical or stemmed reverse
total shoulder arthroplasty was undertaken. Patients received either
100 ml saline (placebo, n = 27), or 100 ml saline together with
1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to
skin incision and during wound closure. Peri-operative blood loss
via an intra-articular drain was recorded and total blood loss was
calculated. The post-operative transfusion rate was documented.
Assessment of early clinical parameters included the visual analogue
scale for pain (VAS), documentation of haematoma formation and adverse events.Aims
Patients and Methods
We present the medium-term clinical results of a reverse total
shoulder arthroplasty with a trabecular metal glenoid base plate. We reviewed 125 consecutive primary reverse total shoulder arthroplasties
(RTSA) implanted in 124 patients for rotator cuff arthropathy. There
were 100 women and 24 men in the study group with a mean age of
76 years (58 to 89). The mean follow-up was 32 months (24 to 60).
No patient was lost to follow-up.Aim
Patients and Methods
Patients with pain and loss of shoulder function
due to nonunion of a fracture of the proximal third of the humerus may
benefit from reverse total shoulder replacement. This paper reports
a prospective, multicentre study, involving three hospitals and
three surgeons, of 35 patients (28 women, seven men) with a mean
age of 69 years (46 to 83) who underwent a reverse total shoulder
replacement for the treatment of nonunion of a fracture of the proximal humerus.
Using Checchia’s classification, nine nonunions were type I, eight
as type II, 12 as type III and six as type IV. The mean follow-up
was 51 months (24 to 99). Post-operatively, the patients had a significant
decrease in pain (p <
0.001), and a significant improvement in
flexion, abduction, external rotation and Constant score (p <
0.001), but not in internal rotation. A total of nine complications
were recorded in seven patients: six dislocations, one glenoid loosening
in a patient who had previously suffered dislocation, one transitory
paresis of the axillary nerve and one infection. Reverse total shoulder replacement may lead to a significant
reduction in pain, improvement in function and a high degree of
satisfaction. However, the rate of complications, particularly dislocation,
was high. Cite this article:
The eccentric glenosphere was principally introduced into reverse
shoulder arthroplasty to reduce the incidence of scapular notching.
There is only limited information about the influence of its design
on deltoid power and joint reaction forces. The aim of our study was to investigate how the diameter and
eccentricity of the glenosphere affect the biomechanics of the deltoid
and the resultant joint reaction forces. Different sizes of glenosphere and eccentricity were serially
tested in ten cadaveric shoulders using a custom shoulder movement
simulator.Aims
Methods
Between 1997 and 2007, 68 consecutive patients underwent replacement of the proximal humerus for tumour using a fixed-fulcrum massive endoprosthesis. Their mean age was 46 years (7 to 87). Ten patients were lost to follow-up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumor Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) at a mean follow-up of five years and 11 months (one year to ten years and nine months). The mean MSTS score was 72.3% (53.3% to 100%) and the mean TESS was 77.2% (58.6% to 100%). Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This subgroup had a mean MSTS score of 77.7% and a mean TESS of 80.0%. The dislocation rate for the original prosthesis was 25.9; none of the patients with the new liner had a dislocation at a mean of 14.5 months (12 to 18). Endoprosthetic replacement for tumours of the proximal humerus using this prosthesis is a reliable operation yielding good results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with a new constrained humeral liner, which reduces the risk of dislocation.
There are theoretical and practical advantages to modular rather than monoblock designs of prostheses for shoulder arthroplasty, but there are no reported studies which specifically compare the clinical and radiological results of their use. We have compared the results of unconstrained total shoulder arthroplasty for osteoarthritis using both types of implant. The monoblock design was used between 1992 and 1995 and the modular design after 1995. Both had cemented all-polyethylene glenoids, the monoblock with matched and the modular with mismatched radii of curvature. There were 34 consecutive shoulders in each group with a mean follow-up of 6.1 years in the first and 5.2 years in the second. There were no significant differences in improvement of pain scores, active elevation, external rotation, internal rotation, patient satisfaction, or the Neer ratings between the two groups. Two of 28 glenoid components in the first group and six of 30 in the second met the criteria for being radiologically at risk for loosening (p = 0.25). There were no significant differences in clinical outcome or radiological changes between the first- and second-generation designs of implant for shoulder arthroplasty.
Our aim in this prospective study was to evaluate the outcome of total shoulder replacement in the treatment of young and middle-aged active patients with primary glenohumeral osteoarthritis. We reviewed 21 patients (21 shoulders) with a mean age of 55 years (37 to 60). The mean follow-up was seven years (5 to 9). The same anatomical, third-generation, cemented implant had been used in all patients. All the patients were evaluated radiologically and clinically using the Constant and Murley score. No patients required revision. In one a tear of the supraspinatus tendon occurred. Overall, 20 patients (95%) were either very satisfied (n = 18) or satisfied (n = 2) with the outcome. Significant differences (p <
0.0001) were found for all categories of the Constant and Murley score pre- and post-operatively. The mean Constant and Murley score increased from 24.1 points (10 to 45) to 64.5 points (39 to 93), and the relative score from 30.4% (11% to 50%) to 83% (54% to 116%). No clinical or radiological signs of loosening of the implant were seen. For young and middle-aged patients with osteoarthritis, third-generation total shoulder replacement is a viable method of treatment with a low rate of complications and excellent results in the mid-term.
We report the effectiveness of revision of total
elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows
in 52 patients were treated with re-cementing of a total elbow replacement
into part or all of the existing cement mantle or into the debrided
host-bone interface, without the use of structural bone augmentation
or a custom prosthesis. The original implant revision was still
If a modular convertible total shoulder system
is used as a primary implant for an anatomical total shoulder arthroplasty,
failure of the prosthesis or the rotator cuff can be addressed by
converting it to a reverse shoulder arthroplasty (RSA), with retention
of the humeral stem and glenoid baseplate. This has the potential
to reduce morbidity and improve the results. In a retrospective study of 14 patients (15 shoulders) with a
mean age of 70 years (47 to 83) we reviewed the clinical and radiological
outcome of converting an anatomical shoulder arthroplasty (ASA)
to a RSA using a convertible prosthetic system (SMR system, Lima,
San Daniele, Italy). The mean operating time was 64 minutes (45 to 75). All humeral
stems and glenoid baseplates were found to be well-fixed and could
be retained. There were no intra-operative or early post-operative
complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the
mean visual analogue scale for pain had decreased from 8 pre-operatively
to 1, the mean American Shoulder and Elbow Surgeons Score from 12
to 76, the mean Oxford shoulder score from 3 to 39, the mean Western
Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and
the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the
humeral stem, two had stress shielding. There were no fatigue fractures
of the acromion but four cases of grade 1 scapular notching. The use of a convertible prosthetic system to revise a failed
ASA reduces morbidity and minimises the rate of complications. The
mid-term clinical and radiological results of this technique are
promising. Cite this article:
Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components.
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0° to 150° of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90° of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.
We assessed the long-term results of 58 Souter-Strathclyde total elbow replacements in 49 patients with rheumatoid arthritis. The mean length of follow-up was 9.5 years (0.7 to 16.7). The mean pre-operative Mayo Elbow Performance Score was 30 (15 to 80) and at final follow-up was 82 (60 to 95). A total of 13 elbows (22.4%) were revised, ten (17.2%) for aseptic loosening, one (1.7%) for instability, one (1.7%) for secondary loosening after fracture, and one elbow (1.7%) was removed because of deep infection. The Kaplan-Meier survival rate was 70% and 53% at ten and 16 years, respectively. Failure of the ulnar component was found to be the main problem in relation to the loosening. Anterior transposition of the ulnar nerve had no influence on ulnar nerve paresthaesiae in these patients.
To date, there is insufficient evidence available to compare
the outcome of cemented and uncemented fixation of the humeral stem
in reverse shoulder arthroplasty (RSA). A systemic review comprising 41 clinical studies was performed
to compare the functional outcome and rate of complications of cemented
and uncemented stems in RSA. These included 1455 cemented and 329
uncemented shoulders. The clinical characteristics of the two groups
were similar. Variables were compared using pooled frequency-weighted means
and relative risk ratios (RR).Aims
Methods