The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
The orientation of the acetabular component can
influence both the short- and long-term outcomes of total hip replacement
(THR). We performed a prospective, randomised, controlled trial
of two groups, comprising of 40 patients each, in order to compare
freehand introduction of the component with introduction using the transverse
acetabular ligament (TAL) as a reference for anteversion. Anteversion
and inclination were measured on pelvic radiographs. With respect to anteversion, in the freehand group 22.5% of the
components were outside the safe zone With respect to inclination, in the freehand group 37.5% of the
components were outside the safe zone The transverse acetabular ligament may be used to obtain the
appropriate anteversion when introducing the acetabular component
during THR, but not acetabular component inclination. Cite this article:
In order to ensure safety of the cell-based therapy for bone
regeneration, we examined BM cells obtained from a total of 13 Sprague-Dawley (SD) green
fluorescent protein transgenic (GFP-Tg) rats were culture-expanded
in an osteogenic differentiation medium for three weeks. Osteoblast-like
cells were then locally transplanted with collagen scaffolds to
the rat model of segmental bone defect. Donor cells were also intravenously infused
to the normal Sprague-Dawley (SD) rats for systemic biodistribution.
The flow cytometric and histological analyses were performed for
cellular tracking after transplantation.Objectives
Methods
We examined patient and surgical factors associated
with deep surgical site infection (SSI) following total hip replacement
(THR) in a large integrated healthcare system. A retrospective review
of a cohort of primary THRs performed between 2001 and 2009 was
conducted. Patient characteristics, surgical details, surgeon and
hospital volumes, and SSIs were identified using the Kaiser Permanente
Total Joint Replacement Registry (TJRR). Proportional-hazard regression
models were used to assess risk factors for SSI. The study cohort
consisted of 30 491 THRs, of which 17 474 (57%) were performed on
women. The mean age of the patients in the whole series was 65.5
years (13 to 97; A comprehensive infection surveillance system, combined with
a TJRR, identified patient and surgical factors associated with
SSI. Obesity and chronic medical conditions should be addressed
prior to THR. The finding of increased SSI risk with bilateral THR
requires further investigation.
We compared thromboembolic events, major haemorrhage
and death after knee replacement in patients receiving either aspirin
or low-molecular-weight heparin (LMWH). Data from the National Joint
Registry for England and Wales were linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 156 798 patients between April 2003 and September 2008
were included and followed for 90 days. Multivariable risk modelling
was used to estimate odds ratios adjusted for baseline risk factors
(AOR). An AOR <
1 indicates that risk rates are lower with LMWH
than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin
and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically
significant differences between the aspirin and LMWH groups in the
rate of pulmonary embolism (0.49% These results should be considered when the existing guidelines
for thromboprophylaxis after knee replacement are reviewed.
Osteochondral injuries, if not treated adequately, often lead
to severe osteoarthritis. Possible treatment options include refixation
of the fragment or replacement therapies such as Pridie drilling,
microfracture or osteochondral grafts, all of which have certain
disadvantages. Only refixation of the fragment can produce a smooth
and resilient joint surface. The aim of this study was the evaluation
of an ultrasound-activated bioresorbable pin for the refixation of
osteochondral fragments under physiological conditions. In 16 Merino sheep, specific osteochondral fragments of the medial
femoral condyle were produced and refixed with one of conventional
bioresorbable pins, titanium screws or ultrasound-activated pins.
Macro- and microscopic scoring was undertaken after three months. Objectives
Methods
The February 2014 Hip &
Pelvis Roundup360 looks at: length of stay; cementless metaphyseal fixation; mortality trends in over 400,000 total hip replacements; antibiotics in hip fracture surgery; blood supply to the femoral head after dislocation; resurfacing and THR in metal-on-metal replacement; diabetes and hip replacement; bone remodelling over two decades following hip replacement; and whether bisphosphonates affect acetabular fixation.
Most posterior hindfoot procedures have been
described with the patient positioned prone. This affords excellent access
to posterior hindfoot structures but has several disadvantages for
the management of the airway, the requirement for an endotracheal
tube in all patients, difficulty with ventilation and an increased
risk of pressure injuries, especially with regard to reduced ocular
perfusion. We describe use of the ‘recovery position’, which affords equivalent
access to the posterior aspect of the ankle and hindfoot without
the morbidity associated with the prone position. A laryngeal mask
rather than endotracheal tube may be used in most patients. In this
annotation we describe this technique, which offers a safe and simple alternative
method of positioning patients for posterior hindfoot and ankle
surgery. Cite this article:
Since the introduction of the National Institute
for Health and Care Excellence (NICE) guidelines on thromboprophylaxis
and the use of extended thromboprophylaxis with new oral agents,
there have been reports of complications arising as a result of
their use. We have looked at the incidence of wound complications
after the introduction of dabigatran for thromboprophylaxis in our
unit. We investigated the rate of venous thromboembolism and wound
leakage in 1728 patients undergoing primary joint replacement, both
before and after the introduction of dabigatran, and following its
subsequent withdrawal from our unit. We found that the use of dabigatran led to a significant increase
in post-operative wound leakage (20% with dabigatran, 5% with a
multimodal regimen; p <
0.001), which also resulted in an increased
duration of hospital stay. The rate of thromboembolism in patients
receiving dabigatran was higher (1.3%) than in those receiving the multimodal
thromboprophylaxis regimen, including low molecular weight heparin
as an inpatient and the extended use of aspirin (0.3%, p = 0.047).
We have ceased the use of dabigatran for thromboprophylaxis in these
patients. Cite this article:
Mobile-bearing unicompartmental knee replacements
(UKRs) with a flat tibial plateau have not performed well in the
lateral compartment, owing to a high dislocation rate. This led
to the development of the Domed Lateral Oxford UKR (Domed OUKR)
with a biconcave bearing. The aim of this study was to assess the
survival and clinical outcomes of the Domed OUKR in a large patient
cohort in the medium term. We prospectively evaluated 265 consecutive knees with isolated
disease of the lateral compartment and a mean age at surgery of
64 years (32 to 90). At a mean follow-up of four years ( The Domed Lateral OUKR gives good clinical outcomes, low re-operation
and revision rates and a low dislocation rate in patients with isolated
lateral compartmental disease, in the hands of the designer surgeons. Cite this article:
Venous thromboembolism (VTE) remains an immediate
threat to patients following total hip and knee replacement. While
there is a strong consensus that steps should be taken to minimise
the risk to patients by utilising some forms of prophylaxis for
the vast majority of patients, the methods utilised have been extremely
variable. Clinical practice guidelines (CPGs) have been published
by various professional organisations for over 25 years to provide recommendations
to standardise VTE prophylaxis. Historically, these recommendations
have varied widely depending in underlying assumptions, goals, and
methodology of the various groups. This effort has previously been
exemplified by the American College of Chest Physicians (ACCP) and
the American Academy of Orthopaedic Surgeons (AAOS). The former
group of medical specialists targeted minimising venographically
proven deep vein thrombosis (DVT) (the vast majority of which are
asymptomatic) as their primary goal prior to 2012. The latter group of
surgeons targeted minimising symptomatic VTE. As a result prior
to 2012, the recommendations of the two groups were widely divergent.
In the past year, both groups have reassessed the current literature
with the principal goals of minimising symptomatic VTE events and
bleeding complications. As a result, for the first time the CPGs
of these two major subspecialty organisations are in close agreement.
Total hip replacement (THR) is a very common
procedure undertaken in up to 285 000 Americans each year. Patient
satisfaction with THR is very high, with improvements in general
health, quality of life, and function while at the same time very
cost effective. Although the majority of patients have a high degree
of satisfaction with their THR, 27% experience some discomfort,
and up to 6% experience severe chronic pain. Although it can be
difficult to diagnose the cause of the pain in these patients, this
clinical issue should be approached systematically and thoroughly.
A detailed history and clinical examination can often provide the
correct diagnosis and guide the appropriate selection of investigations, which
will then serve to confirm the clinical diagnosis made. Cite this article:
Surface hip replacement (SHR) is generally used
in younger, active patients as an alternative conventional total
hip replacement in part because of the ability to preserve femoral
bone. This major benefit of surface replacement will only hold true
if revision procedures of SHRs are found to provide good clinical
results. A retrospective review of SHR revisions between 2007 and 2012
was presented, and the type of revision and aetiologies were recorded.
There were 55 SHR revisions, of which 27 were in women. At a mean
follow-up of 2.3 years (0.72 to 6.4), the mean post-operative Harris
hip score (HHS) was 94.8 (66 to 100). Overall 23 were revised for mechanical
reasons, nine for impingement, 13 for metallosis, nine for unexplained
pain and one for sepsis. Of the type of revision surgery performed,
14 were femoral-only revisions; four were acetabular-only revisions,
and 37 were complete revisions. We did not find that clinical scores were significantly different
between gender or different types of revisions. However, the mean
post-operative HHS was significantly lower in patients revised for
unexplained pain compared with patients revised for mechanical reasons
(86.9 (66 to 100) Based on the overall clinical results, we believe that revision
of SHR can have good or excellent results and warrants a continued
use of the procedure in selected patients. Close monitoring of these
patients facilitates early intervention, as we believe that tissue
damage may be related to the duration of an ongoing problem. There
should be a low threshold to revise a surface replacement if there
is component malposition, rising metal ion levels, or evidence of
soft-tissue abnormalities. Cite this article:
Frozen shoulder is commonly encountered in general
orthopaedic practice. It may arise spontaneously without an obvious
predisposing cause, or be associated with a variety of local or
systemic disorders. Diagnosis is based upon the recognition of the
characteristic features of the pain, and selective limitation of
passive external rotation. The macroscopic and histological features
of the capsular contracture are well-defined, but the underlying
pathological processes remain poorly understood. It may cause protracted
disability, and imposes a considerable burden on health service
resources. Most patients are still managed by physiotherapy in primary
care, and only the more refractory cases are referred for specialist
intervention. Targeted therapy is not possible and treatment remains predominantly
symptomatic. However, over the last ten years, more active interventions
that may shorten the clinical course, such as capsular distension
arthrography and arthroscopic capsular release, have become more popular. This review describes the clinical and pathological features
of frozen shoulder. We also outline the current treatment options,
review the published results and present our own treatment algorithm.
Wrong-level surgery is a unique pitfall in spinal
surgery and is part of the wider field of wrong-site surgery. Wrong-site
surgery affects both patients and surgeons and has received much
media attention. We performed this systematic review to determine
the incidence and prevalence of wrong-level procedures in spinal
surgery and to identify effective prevention strategies. We retrieved
12 studies reporting the incidence or prevalence of wrong-site surgery
and that provided information about prevention strategies. Of these,
ten studies were performed on patients undergoing lumbar spine surgery
and two on patients undergoing lumbar, thoracic or cervical spine procedures.
A higher frequency of wrong-level surgery in lumbar procedures than
in cervical procedures was found. Only one study assessed preventative
strategies for wrong-site surgery, demonstrating that current site-verification protocols
did not prevent about one-third of the cases. The current literature
does not provide a definitive estimate of the occurrence of wrong-site
spinal surgery, and there is no published evidence to support the
effectiveness of site-verification protocols. Further prevention
strategies need to be developed to reduce the risk of wrong-site surgery.
Bicondylar tibial plateau fractures result from
high-energy injuries. Fractures of the tibial plateau can involve
the tibial tubercle, which represents a disruption to the extensor
mechanism and logically must be stabilised. The purpose of this
study was to identify the incidence of an independent tibial tubercle
fracture in bicondylar tibial plateau fractures, and to report management
strategies and potential complications. We retrospectively reviewed
a prospectively collected orthopaedic trauma database for the period
January 2003 to December 2008, and identified 392 bicondylar fractures
of the tibial plateau, in which 85 tibial tubercle fractures (21.6%)
were identified in 84 patients. There were 60 men and 24 women in
our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures
open reduction and internal fixation was undertaken, either with
screws alone (23 patients) or with a plate and screws (61 patients).
The remaining patient was treated non-operatively. In all, 52 fractures
were available for clinical and radiological assessment at a mean
follow-up of 58.5 weeks (24 to 94). All fractures of the tibial
tubercle united, but 24 of 54 fractures (46%) required a secondary
procedure for their tibial plateau fracture. Four patients reported
pain arising from prominent tubercle plates and screws, which in
one patient required removal. Tibial tubercle fractures occurred
in over one-fifth of the bicondylar tibial plateau fractures in
our series. Fixation is necessary and can be reliably performed
with screws alone or with a screw and plate, which restores the
extensor mechanism and facilitates early knee flexion. Cite this article:
Bilateral simultaneous total knee replacement (TKR) has been considered by some to be associated with increased morbidity and mortality. Our study analysed the outcome of 150 consecutive, but selected, bilateral simultaneous TKRs and compared them with that of 271 unilateral TKRs in a standardised fast-track setting. The procedures were performed between 2003 and 2009. Apart from staying longer in hospital (mean 4.7 days (2 to 16)
We compared thromboembolic events, major haemorrhage
and death after total hip replacement in patients receiving either
aspirin or low-molecular-weight heparin (LMWH). We analysed data from
the National Joint Registry for England and Wales linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 108 584 patients operated on between April 2003 and September 2008
were included and followed up for 90 days. Multivariable risk modelling
and propensity score matching were used to estimate odds ratios
(OR) adjusted for baseline risk factors. An OR <
1 indicates
that rates are lower with LMWH than with aspirin. In all, 21.1%
of patients were prescribed aspirin and 78.9% LMWH. Without adjustment, we
found no statistically significant differences. The rate of pulmonary
embolism was 0.68% in both groups and 90-day mortality was 0.65%
with aspirin and 0.61% with LMWH (OR 0.93; 95% CI 0.77 to 1.11).
With risk adjustment, the difference in mortality increased (OR
0.84; 95% CI 0.69 to 1.01). With propensity score matching the mortality difference
increased even further to 0.65% with aspirin and 0.51% with LMWH
(OR 0.77; 95% CI 0.61 to 0.98). These results should be considered
when the conflicting recommendations of existing guidelines for
thromboprophylaxis after hip replacement are being addressed.
By and large, physicians and surgeons trust what they read, even if they take authors’ conclusions with a pinch of salt. There is a world of difference between being cautious about the implications of what you read and being defrauded by dishonest researchers. Fraud and scientific research are incompatible bedfellows and yet are an unhappy part of our research existence. All subspecialties are to blame and orthopaedics is no exception.
Blood loss during total knee replacement (TKR)
remains a significant concern. In this study, 114 patients underwent TKR,
and were divided into two groups based on whether they received
a new generation fibrin sealant intra-operatively, or a local infiltration
containing adrenaline. Groups were then compared for mean calculated
total blood volume (TBV) loss, transfusion rates, and knee range
of movement. Mean TBV loss was similar between groups: fibrin sealant
mean was 705 ml (281 to 1744), local adrenaline mean was 712 ml
(261 to 2308) (p = 0.929). Overall, significantly fewer units of
blood were transfused in the fibrin sealant group (seven units)
compared with the local adrenaline group (15 units) (p = 0.0479).
Per patient transfused, significantly fewer units of blood were transfused
in the fibrin sealant group (1.0 units) compared with the local
adrenaline group (1.67 units) (p = 0.027), suggesting that the fibrin
sealant may reduce the need for multiple unit transfusions. Knee
range of movement was similar between groups. From our results,
it appears that application of this newer fibrin sealant results
in blood loss and transfusion rates that are low and similar to
previously applied fibrin sealants. Cite this article: