Advertisement for orthosearch.org.uk
Results 941 - 960 of 1331
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 536 - 543
1 Apr 2012
Brown KV Guthrie HC Ramasamy A Kendrew JM Clasper J

The types of explosive devices used in warfare and the pattern of war wounds have changed in recent years. There has, for instance, been a considerable increase in high amputation of the lower limb and unsalvageable leg injuries combined with pelvic trauma.

The conflicts in Iraq and Afghanistan prompted the Department of Military Surgery and Trauma in the United Kingdom to establish working groups to promote the development of best practice and act as a focus for research.

In this review, we present lessons learnt in the initial care of military personnel sustaining major orthopaedic trauma in the Middle East.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 751 - 759
1 Jun 2010
Tsirikos AI Garrido EG

A review of the current literature shows that there is a lack of consensus regarding the treatment of spondylolysis and spondylolisthesis in children and adolescents. Most of the views and recommendations provided in various reports are weakly supported by evidence. There is a limited amount of information about the natural history of the condition, making it difficult to compare the effectiveness of various conservative and operative treatments. This systematic review summarises the current knowledge on spondylolysis and spondylolisthesis and attempts to present a rational approach to the evaluation and management of this condition in children and adolescents.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 333 - 338
1 Mar 2013
Jack CM Molloy DO Walter WL Zicat BA Walter WK

The practice of removing a well-fixed cementless femoral component is associated with high morbidity. Ceramic bearing couples are low wearing and their use minimises the risk of subsequent further revision due to the production of wear debris. A total of 165 revision hip replacements were performed, in which a polyethylene-lined acetabular component was revised to a new acetabular component with a ceramic liner, while retaining the well-fixed femoral component. A titanium sleeve was placed over the used femoral trunnion, to which a ceramic head was added. There were 100 alumina and 65 Delta bearing couples inserted.

The mean Harris hip score improved significantly from 71.3 (9.0 to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow up of 4.8 years (2.1 to 12.5) (p < 0.001). No patients reported squeaking of the hip.

There were two fractures of the ceramic head, both in alumina bearings. No liners were seen to fracture. No fractures were observed in components made of Delta ceramic. At 8.3 years post-operatively the survival with any cause of failure as the endpoint was 96.6% (95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and 94.0% (95% CI 82.1 to 98.4) for the femoral component.

The technique of revising the acetabular component in the presence of a well-fixed femoral component with a ceramic head placed on a titanium sleeve over the used trunnion is a useful adjunct in revision hip practice. The use of Delta ceramic is recommended.

Cite this article: Bone Joint J 2013;95-B:333–8.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1098 - 1105
1 Aug 2014
Brown MT Gikas PD Bhamra JS Skinner JA Aston WJS Pollock RC Saifuddin A Briggs TWR

The pre-operative differentiation between enchondroma, low-grade chondrosarcoma and high-grade chondrosarcoma remains a diagnostic challenge. We reviewed the accuracy and safety of the radiological grading of cartilaginous tumours through the assessment of, first, pre-operative radiological and post-operative histological agreement, and second the rate of recurrence in lesions confirmed as high-grade on histology. We performed a retrospective review of major long bone cartilaginous tumours managed by curettage as low grade between 2001 and 2012. A total of 53 patients with a mean age of 47.6 years (8 to 71) were included. There were 23 men and 30 women. The tumours involved the femur (n = 20), humerus (n = 18), tibia (n = 9), fibula (n = 3), radius (n = 2) and ulna (n = 1). Pre-operative diagnoses resulted from multidisciplinary consensus following radiological review alone for 35 tumours, or with the addition of pre-operative image guided needle biopsy for 18. The histologically confirmed diagnosis was enchondroma for two (3.7%), low-grade chondrosarcoma for 49 (92.6%) and high-grade chondrosarcoma for two (3.7%). Three patients with a low-grade tumour developed a local recurrence at a mean of 15 months (12 to 17) post-operatively. A single high-grade recurrence (grade II) was treated with tibial diaphyseal replacement. The overall recurrence rate was 7.5% at a mean follow-up of 4.7 years (1.2 to 12.3). Cartilaginous tumours identified as low-grade on pre-operative imaging with or without additional image-guided needle biopsy can safely be managed as low-grade without pre-operative histological diagnosis. A few tumours may demonstrate high-grade features histologically, but the rates of recurrence are not affected.

Cite this article: Bone Joint J 2014; 96-B:1098–105.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1207 - 1213
1 Sep 2014
te Stroet MAJ Bronsema E Rijnen WHC Gardeniers JWM Schreurs BW

In this retrospective study, we investigated the results of revision total hip replacement (THR) using a cemented long-stemmed Exeter femoral component, with a minimum length of 205 mm in patients with extensive femoral bone defects. The study included 37 consecutive patients with a mean age of 76 years (39 to 93) and a mean follow-up of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative Endo-Klinik score of 3 or 4. Impaction bone grafting was used in 24 patients (65%). At the time of evaluation, 22 patients (59%) were still alive and were evaluated clinically and radiologically. A total of 14 patients died during follow-up and their data were included until the time of their death. One reconstruction failed after five years and five months owing to recurrent dislocation: the hip was converted to an excision arthroplasty. Intra-operative fractures or fissures were encountered in nine patients (24%), but none occurred during impaction of the bone graft. Post-operative peri-prosthetic fractures occurred in two patients (5%); both were treated with plate fixation. At nine years, survival with the endpoint of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%). There were no re-revisions for aseptic loosening.

The survival of long stem cemented femoral components following revision THR is satisfactory in a fragile population with extensive femoral defects.

Cite this article: Bone Joint J 2014; 96-B:1207–13.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 604 - 608
1 May 2014
von Schewelov T Carlsson Å Sanzén L Besjakov J

In 2005, we demonstrated that the polished triple-tapered C-stem at two years had migrated distally and rotated internally. From that series, 33 patients have now been followed radiologically, clinically and by radiostereometric analysis (RSA) for up to ten years. The distal migration within the cement mantle had continued and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation, also within the cement mantle, was a mean 3.8° (external 1.6° to internal 6.6°) The cement mantle did not show any sign of migration or loosening in relation to the femoral bone. There were no clinical or radiological signs indicating that the migration or rotation within the cement mantle had had any adverse effects for the patients.

Cite this article: Bone Joint J 2014;96-B:604–8.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1244 - 1251
1 Sep 2014
Khoshbin A Vivas L Law PW Stephens D Davis AM Howard A Jarvis JG Wright JG

The purpose of this study was to evaluate the long-term outcome of adults with spina bifida cystica (SBC) who had been treated either operatively or non-operatively for scoliosis during childhood.

We reviewed 45 patients with a SBC scoliosis (Cobb angle ≥ 50º) who had been treated at one of two children’s hospitals between 1991 and 2007. Of these, 34 (75.6%) had been treated operatively and 11 (24.4%) non-operatively. After a mean follow-up of 14.1 years (standard deviation (sd) 4.3) clinical, radiological and health-related quality of life (HRQOL) outcomes were evaluated using the Spina Bifida Spine Questionnaire (SBSQ) and the 36-Item Short Form Health Survey (SF-36).

Although patients in the two groups were demographically similar, those who had undergone surgery had a larger mean Cobb angle (88.0º (sd 20.5; 50.0 to 122.0); versus 65.7º (sd 22.0; 51.0 to 115.0); p < 0.01) and a larger mean clavicle–rib intersection difference (12.3 mm; (sd 8.5; 1 to 37); versus 4.1 mm, (sd 5.9; 0 to 16); p = 0.01) than those treated non-operatively. Both groups were statistically similar at follow-up with respect to walking capacity, neurological motor level, sitting balance and health-related quality of life (HRQOL) outcomes.

Spinal fusion in SBC scoliosis corrects coronal deformity and stops progression of the curve but has no clear effect on HRQOL.

Cite this article: Bone Joint J 2014; 96-B:1244–51


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1494 - 1498
1 Nov 2012
Philippon MJ Pennock A Gaskill TR

Femoroacetabular impingement causes groin pain and decreased athletic performance in active adults. This bony conflict may result in femoroacetabular subluxation if of sufficient magnitude.

The ligamentum teres has recently been reported to be capable of withstanding tensile loads similar to that of the anterior cruciate ligament, and patents with early subluxation of the hip may become dependent on the secondary restraint that is potentially provided by the ligamentum teres. Rupture of the ligamentum may thus cause symptomatic hip instability during athletic activities.

An arthroscopic reconstruction of the ligamentum teres using iliotibial band autograft was performed in an attempt to restore this static stabiliser in a series of four such patients. Early clinical results have been promising. The indications, technique and early outcomes of this procedure are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 549 - 555
1 Apr 2012
Lefaivre KA Slobogean GP Valeriote J O’Brien PJ Macadam SA

We performed a systematic review of the literature to evaluate the use and interpretation of generic and disease-specific functional outcome instruments in the reporting of outcome after the surgical treatment of disruptions of the pelvic ring. A total of 28 papers met our inclusion criteria, with eight reporting only generic outcome instruments, 13 reporting only pelvis-specific outcome instruments, and six reporting both. The Short-Form 36 (SF-36) was by far the most commonly used generic outcome instrument, used in 12 papers, with widely variable reporting of scores. The pelvis-specific outcome instruments were used in 19 studies; the Majeed score in ten, Iowa pelvic score in six, Hannover pelvic score in two and the Orlando pelvic score in one. Four sets of authors, all testing construct validity based on correlation with the SF-36, performed psychometric testing of three pelvis-specific instruments (Majeed, IPS and Orlando scores). No testing of responsiveness, content validity, criterion validity, internal consistency or reproducibility was performed.

The existing literature in this area is inadequate to inform surgeons or patients in a meaningful way about the functional outcomes of these fractures after fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1209 - 1214
1 Sep 2010
Hill JC Gibson DP Pagoti R Beverland DE

The angle of inclination of the acetabular component in total hip replacement is a recognised contributing factor in dislocation and early wear. During non-navigated surgery, insertion of the acetabular component has traditionally been performed at an angle of 45° relative to the sagittal plane as judged by the surgeon’s eye, the operative inclination. Typically, the method used to assess inclination is the measurement made on the postoperative anteroposterior radiograph, the radiological inclination.

The aim of this study was to measure the intra-operative angle of inclination of the acetabular component on 60 consecutive patients in the lateral decubitus position when using a posterior approach during total hip replacement. This was achieved by taking intra-operative photographs of the acetabular inserter, representing the acetabular axis, and a horizontal reference. The results were compared with the post-operative radiological inclination.

The mean post-operative radiological inclination was 13° greater than the photographed operative inclination, which was unexpectedly high. It appears that in the lateral decubitus position with a posterior approach, the uppermost hemipelvis adducts, thus reducing the apparent operative inclination. Surgeons using the posterior approach in lateral decubitus need to aim for a lower operative inclination than when operating with the patient supine in order to achieve an acceptable radiological inclination.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 9 - 12
1 Apr 2014

The April 2014 Knee Roundup360 looks at: mobile compression as good as chemical thromboprophylaxis; patellar injury with MIS knee surgery; tibial plateau fracture results not as good as we thought; back and knee pain; metaphyseal sleeves may be the answer in revision knee replacement; oral tranexamic acid; gentamycin alone in antibiotic spacers; and whether the jury is still out on unloader braces.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 994 - 997
1 Jul 2012
Cross MB Nam D van der Meulen MCH Bostrom MPG

An 81-year-old woman presented with a fracture in the left femur. She had well-fixed bilateral hip replacements and had received long-term bisphosphonate treatment. Prolonged bisphosphonate use has been recently linked with atypical subtrochanteric and diaphyseal femoral fractures. While the current definition of an atypical fracture of the femur excludes peri-prosthetic fractures, this case suggests that they do occur and should be considered in patients with severe osteopenia. Union of the fracture followed cessation of bisphosphonates and treatment with teriparatide. Thus, this case calls into question whether prophylactic intramedullary nailing is sufficient alone to treat early or completed atypical femoral fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1031 - 1036
1 Aug 2009
Dandachli W Islam SU Liu M Richards R Hall-Craggs M Witt J

This study examined the relationship between the cross-over sign and the true three-dimensional anatomical version of the acetabulum. We also investigated whether in true retroversion there is excessive femoral head cover anteriorly. Radiographs of 64 hips in patients being investigated for symptoms of femoro-acetabular impingement were analysed and the presence of a cross-over sign was documented. CT scans of the same hips were analysed to determine anatomical version and femoral head cover in relation to the anterior pelvic plane after correcting for pelvic tilt. The sensitivity and specificity of the cross-over sign were 92% and 55%, respectively for identifying true acetabular retroversion. There was no significant difference in total cover between normal and retroverted cases. Anterior and posterior cover were, however, significantly different (p < 0.001 and 0.002). The cross-over sign was found to be sensitive but not specific. The results for femoral head cover suggest that retroversion is characterised by posterior deficiency but increased cover anteriorly.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 20 - 22
1 Apr 2014

The April 2014 Trauma Roundup360 looks at: is it safe to primarily close dog bite wounds?; conservative transfusion evidence based in hip fracture surgery; tibial nonunion is devastating to quality of life; sexual dysfunction after traumatic pelvic fracture; hemiarthroplasty versus fixation in displaced femoral neck fractures; silver VAC dressings “Gold Standard” in massive wounds; dual plating for talar neck fracture; syndesmosis and fibular length easiest errors in ankle fracture surgery; and dual mobility: stable as a rock in fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1428 - 1434
1 Nov 2008
Dandachli W Kannan V Richards R Shah Z Hall-Craggs M Witt J

We present a new CT-based method which measures cover of the femoral head in both normal and dysplastic hips and allows assessment of acetabular inclination and anteversion. A clear topographical image of the head with its covered area is generated.

We studied 36 normal and 39 dysplastic hips. In the normal hips the mean cover was 73% (66% to 81%), whereas in the dysplastic group it was 51% (38% to 64%). The significant advantage of this technique is that it allows the measurements to be standardised with reference to a specific anatomical plane. When this is applied to assessing cover in surgery for dysplasia of the hip it gives a clearer understanding of where the corrected hip stands in relation to normal and allows accurate assessment of inclination and anteversion.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 658 - 664
1 May 2014
Teo BJX Koh JSB Goh SK Png MA Chua DTC Howe TS

Management of bisphosphonate-associated subtrochanteric fractures remains opinion- or consensus-based. There are limited data regarding the outcomes of this fracture.

We retrospectively reviewed 33 consecutive female patients with a mean age of 67.5 years (47 to 91) who were treated surgically between May 2004 and October 2009. The mean follow-up was 21.7 months (0 to 53). Medical records and radiographs were reviewed to determine the post-operative ambulatory status, time to clinical and radiological union and post-fixation complications such as implant failure and need for second surgery.

The predominant fixation method was with an extramedullary device in 23 patients. 25 (75%) patients were placed on wheelchair mobilisation or no weight-bearing initially. The mean time to full weight-bearing was 7.1 months (2.2 to 29.7). The mean time for fracture site pain to cease was 6.2 months (1.2 to 17.1). The mean time to radiological union was 10.0 months (2.2 to 27.5). Implant failure was seen in seven patients (23%, 95 confidence interval (CI) 11.8 to 40.9). Revision surgery was required in ten patients (33%, 95 CI 19.2 to 51.2).

A large proportion of the patients required revision surgery and suffered implant failure. This fracture is associated with slow healing and prolonged post-operative immobility.

Cite this article: Bone Joint J 2014;96-B:658–64.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 426 - 430
1 Mar 2014
Ferguson JY Sutherland M Pandit HG McNally M

Recent recommendations by the National Institute for Health and Care Excellence (NICE) suggest that all patients undergoing elective orthopaedic surgery should be assessed for the risk of venous thromboembolism (VTE).

Little is known about the incidence of symptomatic VTE after elective external fixation. We studied a consecutive series of adult patients who had undergone elective Ilizarov surgery without routine pharmacological prophylaxis to establish the incidence of symptomatic VTE.

A review of a prospectively maintained database of consecutive patients who were treated between October 1998 and February 2011 identified 457 frames in 442 adults whose mean age was 42.6 years (16.0 to 84.6). There were 425 lower limb and 32 upper limb frames. The mean duration of treatment was 25.7 weeks (1.6 to 85.3).

According to NICE guidelines all the patients had at least one risk factor for VTE, 246 had two, 172 had three and 31 had four or more.

One patient (0.23%) developed a pulmonary embolus after surgery and was later found to have an inherited thrombophilia. There were 27 deaths, all unrelated to VTE.

The cost of providing VTE prophylaxis according to NICE guidelines in this group of patients would be £89 493.40 (£195.80 per patient) even if the cheapest recommended medication was used.

The rate of symptomatic VTE after Ilizarov surgery was low despite using no pharmacological prophylaxis. This study leads us to question whether NICE guidelines are applicable to these patients.

Cite this article: Bone Joint J 2014;96-B:426–30.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 32 - 34
1 Feb 2014

The February 2014 Oncology Roundup360 looks at: suspicious lesions; limb salvage in pelvic sarcomas; does infection affect oncological survival?; cancer patient pathways; radiological arthritis with cement augmentation in GCT; and post-chemotherapy increase in tumour volume as a predictor of poor prognosis.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 829 - 836
1 Jun 2014
Ferguson JY Dudareva M Riley ND Stubbs D Atkins BL McNally MA

We report our experience using a biodegradable calcium sulphate antibiotic carrier containing tobramycin in the surgical management of patients with chronic osteomyelitis. The patients were reviewed to determine the rate of recurrent infection, the filling of bony defects, and any problems with wound healing. A total of 193 patients (195 cases) with a mean age of 46.1 years (16.1 to 82.0) underwent surgery. According to the Cierny–Mader classification of osteomyelitis there were 12 type I, 1 type II, 144 type III and 38 type IV cases. The mean follow-up was 3.7 years (1.3 to 7.1) with recurrent infection occurring in 18 cases (9.2%) at a mean of 10.3 months post-operatively (1 to 25.0). After further treatment the infection resolved in 191 cases (97.9%). Prolonged wound ooze (longer than two weeks post-operatively) occurred in 30 cases (15.4%) in which there were no recurrent infection. Radiographic assessment at final follow-up showed no filling of the defect with bone in 67 (36.6%), partial filling in 108 (59.0%) and complete filling in eight (4.4%). A fracture occurred in nine (4.6%) of the treated osteomyelitic segments at a mean of 1.9 years (0.4 to 4.9) after operation.

We conclude that Osteoset T is helpful in the management of patients with chronic osteomyelitis, but the filling of the defect in bone is variable. Prolonged wound ooze is usually self-limiting and not associated with recurrent infection.

Cite this article: Bone Joint J 2014; 96-B:829–36


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 215 - 221
1 Feb 2007
Krieg AH Hefti F

We evaluated 31 patients who were treated with a non-vascularised fibular graft after resection of primary musculoskeletal tumours, with a median follow-up of 5.6 years (3 to 26.7 years). Primary union was achieved in 89% (41 of 46) of the grafts in a median period of 24 weeks. All 25 grafts in 18 patients without additional chemotheraphy and/or radiotherapy achieved primary union, compared with 16 of the 21 grafts (76%; 13 patients) with additional therapy (p = 0.017). Radiographs showed an increase in diameter in 70% (59) of the grafts. There were seven fatigue fractures in six patients, but only two needed treatment.

Non-vascularised fibular transfer is a simpler, less expensive and a shorter procedure than the use of vascularised grafts and allows remodelling of the fibula at the donor site. It is a biological reconstruction with good long-term results, and a relatively low donor site complication rate of 16%.