Advertisement for orthosearch.org.uk
Results 941 - 960 of 1186
Results per page:
Bone & Joint Research
Vol. 2, Issue 5 | Pages 79 - 83
1 May 2013
Goffin JM Pankaj P Simpson AHRW Seil R Gerich TG

Objectives

Because of the contradictory body of evidence related to the potential benefits of helical blades in trochanteric fracture fixation, we studied the effect of bone compaction resulting from the insertion of a proximal femoral nail anti-rotation (PFNA).

Methods

We developed a subject-specific computational model of a trochanteric fracture (31-A2 in the AO classification) with lack of medial support and varied the bone density to account for variability in bone properties among hip fracture patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 966 - 971
1 Jul 2013
Pumberger M Froemel D Aichmair A Hughes AP Sama AA Cammisa FP Girardi FP

The purpose of this study was to investigate the clinical predictors of surgical outcome in patients with cervical spondylotic myelopathy (CSM). We reviewed a consecutive series of 248 patients (71 women and 177 men) with CSM who had undergone surgery at our institution between January 2000 and October 2010. Their mean age was 59.0 years (16 to 86). Medical records, office notes, and operative reports were reviewed for data collection. Special attention was focused on pre-operative duration and severity as well as post-operative persistence of myelopathic symptoms. Disease severity was graded according to the Nurick classification.

Our multivariate logistic regression model indicated that Nurick grade 2 CSM patients have the highest chance of complete symptom resolution (p < 0.001) and improvement to normal gait (p = 0.004) following surgery. Patients who did not improve after surgery had longer duration of myelopathic symptoms than those who did improve post-operatively (17.85 months (1 to 101) vs 11.21 months (1 to 69); p = 0.002). More advanced Nurick grades were not associated with a longer duration of symptoms (p = 0.906).

Our data suggest that patients with Nurick grade 2 CSM are most likely to improve from surgery. The duration of myelopathic symptoms does not have an association with disease severity but is an independent prognostic indicator of surgical outcome.

Cite this article: Bone Joint J 2013;95-B:966–71.


Bone & Joint 360
Vol. 2, Issue 2 | Pages 25 - 28
1 Apr 2013

The April 2013 Trauma Roundup360 looks at: ankle sprains; paediatric knee haemarthroses; evidence to support a belief; ‘Moonboot’ saves the day; pamphlets and outcomes; poor gait in pilons; lactate and surgical timing; and marginal results with marginal impaction.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 301 - 304
1 Mar 2013
Brennan SA Devitt BM O’Neill CJ Nicholson P

Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed.

Cite this article: Bone Joint J 2013;95-B:301–4.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1673 - 1680
1 Dec 2013
Papakostidis C Bhandari M Giannoudis PV

We carried out a systematic review of the literature to evaluate the evidence regarding the clinical results of the Ilizarov method in the treatment of long bone defects of the lower limbs.

Only 37 reports (three non-randomised comparative studies, one prospective study and 33 case-series) met our inclusion criteria. Although several studies were unsatisfactory in terms of statistical heterogeneity, our analysis appears to show that the Ilizarov method of distraction osteogenesis significantly reduced the risk of deep infection in infected osseous lesions (risk ratio 0.14 (95% confidence interval (CI) 0.10 to 0.20), p < 0.001). However, there was a rate of re-fracture of 5% (95% CI 3 to 7), with a rate of neurovascular complications of 2.2% (95% CI 0.3 to 4) and an amputation rate of 2.9% (95% CI 1.4 to 4.4).The data was generally not statistically heterogeneous. Where tibial defects were > 8 cm, the risk of re-fracture increased (odds ratio 3.7 (95% CI 1.1 to 12.5), p = 0.036).

The technique is demanding for patients, illustrated by the voluntary amputation rate of 1.6% (95% CI 0 to 3.1), which underlines the need for careful patient selection.

Cite this article: Bone Joint J 2013;95-B:1673–80.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 801 - 805
1 Jun 2011
Quah C Boulton C Moran C

This is the first study to use the English Indices of Multiple Deprivation 2007, the Government’s official measure of multiple deprivation, to analyse the effect of socioeconomic status on the incidence of fractures of the hip and their outcome and mortality. Our sample consisted of all patients admitted to hospital with a fracture of the hip (n = 7511) in Nottingham between 1999 and 2009.

The incidence was 1.3 times higher (p = 0.038) in the most deprived populations than in the least deprived; the most deprived suffered a fracture, on average, 1.1 years earlier (82.0 years versus 83.1 years, p < 0.001). The mortality rate proved to be significantly higher in the most deprived population (log-rank test, p = 0.033), who also had a higher number of comorbidities (p = 0.001).

This study has shown an increase in the incidence of fracture of the hip in the most deprived population, but no association between socioeconomic status and mortality at 30 days. Preventative programmes aimed at reducing the risk of hip fracture should be targeted towards the more deprived if they are to make a substantial impact.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 401 - 406
1 Mar 2013
Rebolledo BJ Gladnick BP Unnanuntana A Nguyen JT Kepler CK Lane JM

This is a prospective randomised study comparing the clinical and radiological outcomes of uni- and bipedicular balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. A total of 44 patients were randomised to undergo either uni- or bipedicular balloon kyphoplasty. Self-reported clinical assessment using the Oswestry Disability Index, the Roland-Morris Disability questionnaire and a visual analogue score for pain was undertaken pre-operatively, and at three and twelve months post-operatively. The vertebral height and kyphotic angle were measured from pre- and post-operative radiographs. Total operating time and the incidence of cement leakage was recorded for each group.

Both uni- and bipedicular kyphoplasty groups showed significant within-group improvements in all clinical outcomes at three months and twelve months after surgery. However, there were no significant differences between the groups in all clinical and radiological outcomes. Operating time was longer in the bipedicular group (p < 0.001). The incidence of cement leakage was not significantly different in the two groups (p = 0.09).

A unipedicular technique yielded similar clinical and radiological outcomes as bipedicular balloon kyphoplasty, while reducing the length of the operation. We therefore encourage the use of a unipedicular approach as the preferred surgical technique for the treatment of osteoporotic vertebral compression fractures.

Cite this article: Bone Joint J 2013;95-B:401–6.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 25 - 27
1 Feb 2013

The February 2013 Shoulder & Elbow Roundup360 looks at: whether we should replace fractured shoulders; the limited evidence for shoulder fractures; cuffs and early physio; matrix proteins and cuff tears; long-term SLAP tear outcomes; suture anchors; recurrent Bankart repairs; and acromial morphology and calcific tendonitis.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 343 - 347
1 Mar 2013
Odak S Ivory J

Deficiency of the abductor mechanism is a well-recognised cause of pain and limping after total hip replacement (THR). This can be found incidentally at the time of surgery, or it may arise as a result of damage to the superior gluteal nerve intra-operatively, or after surgery owing to mechanical failure of the abductor muscle repair or its detachment from the greater trochanter. The incidence of abductor failure has been reported as high as 20% in some studies. The management of this condition remains a dilemma for the treating surgeon. We review the current state of knowledge concerning post-THR abductor deficiency, including the aetiology, diagnosis and management, and the outcomes of surgery for this condition.

Cite this article: Bone Joint J 2013;95-B:343–7.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 27 - 30
1 Feb 2013

The February 2013 Spine Roundup360 looks at: complications with anterior decompression and fusion; lumbar claudication and peripheral vascular disease; increasing cervical instability in rheumatoids; kyphoplasty; cervical stenosis; exercise or fusion for chronic lower back pain; lumbar disc arthroplasty and adjacent level changes; and obese disc prolapses.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 530 - 532
1 Apr 2009
Sen D Alsousou J Fraser J

We describe a technique to salvage a painful hemiarthroplasty due to erosion of the acetabular cartilage in the absence of loosening of the femoral component. A press-fit metallic acetabular component which matched the femoral component was used as a metal-on-metal articulation. The procedure offered a shorter operation time with less blood loss and no risk of femoral fracture as might have occurred during conventional revision to a total hip replacement. The patient made an unremarkable recovery with a good outcome at follow-up of 15 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 110 - 115
1 Jan 2010
Bosma E de Jongh MAC Verhofstad MHJ

This retrospective cohort study was conducted to investigate whether operative treatment of patients with a pertrochanteric femoral fracture outside working hours is associated with an increased risk of complications and higher mortality. During the study period 165 patients were operated on outside working hours and 123 were operated on during working hours (08.00 to 17.00). There was no difference in the rate of early complications (outside working hours 33% versus working hours 33%, p = 0.91) or total complications during follow-up (outside working hours 40% versus working hours 41%, p = 0.91). Both in-hospital mortality (outside working hours 12% versus working hours 11%, p = 0.97) and mortality after one year (outside working hours 29% versus working hours 27%, p = 0.67) were comparable. Adjustment for possible confounders by multivariate logistic regression analysis revealed no increased risk of complications when patients were operated on outside working hours.

On the basis of these data, there is no medical reason to postpone operative reduction and fixation in patients with a proximal femoral fracture until working hours.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 137 - 140
1 Nov 2012
Jones RE Russell RD Huo MH

Most problems encountered in complex revision total knee arthroplasty can be managed with the wide range of implant systems currently available. Modular metaphyseal sleeves, metallic augments and cones provide stability even with significant bone loss. Hinged designs substitute for significant ligamentous deficiencies. Catastrophic failure that precludes successful reconstruction can be encountered. The alternatives to arthroplasty in such drastic situations include knee arthrodesis, resection arthroplasty and amputation. The relative indications for the selection of these alternatives are recurrent deep infection, immunocompromised host, and extensive non-reconstructible bone or soft-tissue defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 842 - 852
1 Jun 2010
Tannast M Krüger A Mack PW Powell JN Hosalkar HS Siebenrock KA

Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9).

Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports.

Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.


Bone & Joint Research
Vol. 2, Issue 3 | Pages 58 - 65
1 Mar 2013
Johnson R Jameson SS Sanders RD Sargant NJ Muller SD Meek RMD Reed MR

Objectives

To review the current best surgical practice and detail a multi-disciplinary approach that could further reduce joint replacement infection.

Methods

Review of relevant literature indexed in PubMed.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 166 - 172
1 Feb 2013
Abolghasemian M Tangsataporn S Sternheim A Backstein D Safir O Gross AE

Trabecular metal (TM) augments are a relatively new option for reconstructing segmental bone loss during acetabular revision. We studied 34 failed hip replacements in 34 patients that were revised between October 2003 and March 2010 using a TM acetabular shell and one or two augments. The mean age of the patients at the time of surgery was 69.3 years (46 to 86) and the mean follow-up was 64.5 months (27 to 107). In all, 18 patients had a minor column defect, 14 had a major column defect, and two were associated with pelvic discontinuity. The hip centre of rotation was restored in 27 patients (79.4%). The Oxford hip score increased from a mean of 15.4 points (6 to 25) before revision to a mean of 37.7 (29 to 47) at the final follow-up. There were three aseptic loosenings of the construct, two of them in the patients with pelvic discontinuity. One septic loosening also occurred in a patient who had previously had an infected hip replacement. The augments remained stable in two of the failed hips. Whenever there was a loose acetabular component in contact with a stable augment, progressive metal debris shedding was evident on the serial radiographs. Complications included another deep infection treated without revision surgery. Good clinical and radiological results can be expected for bone-deficient acetabula treated by a TM cup and augment, but for pelvic discontinuities this might not be a reliable option.

Cite this article: Bone Joint J 2013;95-B:166–72.


Severe hallux valgus deformity is conventionally treated with proximal metatarsal osteotomy. Distal metatarsal osteotomy with an associated soft-tissue procedure can also be used in moderate to severe deformity. We compared the clinical and radiological outcomes of proximal and distal chevron osteotomy in severe hallux valgus deformity with a soft-tissue release in both. A total of 110 consecutive female patients (110 feet) were included in a prospective randomised controlled study. A total of 56 patients underwent a proximal procedure and 54 a distal operation. The mean follow-up was 39 months (24 to 54) in the proximal group and 38 months (24 to 52) in the distal group. At follow-up the hallux valgus angle, intermetatarsal angle, distal metatarsal articular angle, tibial sesamoid position, American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal score, patient satisfaction level, and complications were similar in each group. Both methods showed significant post-operative improvement and high levels of patient satisfaction. Our results suggest that the distal chevron osteotomy with an associated distal soft-tissue procedure provides a satisfactory method for correcting severe hallux valgus deformity.

Cite this article: Bone Joint J 2013;95-B:510–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1424 - 1430
1 Nov 2009
Corten K Vanrykel F Bellemans J Frederix PR Simon J Broos PLO

The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored.

Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed.

Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 865 - 869
1 Jul 2009
Shah NN Edge AJ Clark DW

In 2004 we described the ten-year prospective results of 38 total hip replacements using the Furlong hydroxyapatite-ceramic-coated femoral component in 35 patients < 50 years old. We have now reviewed the surviving 35 arthroplasties in 33 patients at a mean of 16 years (10.3 to 19.9). The mean age of the surviving patients at the time of operation was 41.3 years (26.0 to 49.0). Of these, eight have undergone revision of their acetabular component for aseptic loosening. None of the femoral components has had revision for aseptic loosening giving a survival rate of 100% at 16 years (95% confidence interval 89% to 100%).

The Furlong hydroxyapatite-ceramic-coated femoral component gives excellent long-term survival in young and active patients.