header advert
Results 4701 - 4800 of over 10000
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation.

In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group.

Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation.

The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used.

Cite this article: Bone Joint J 2015;97-B:398–404.


Bone & Joint Research
Vol. 4, Issue 3 | Pages 45 - 49
1 Mar 2015
Thompson MJ Ross J Domson G Foster W

Objectives

The clinical utility of routine cross sectional imaging of the abdomen and pelvis in the screening and surveillance of patients with primary soft-tissue sarcoma of the extremities for metastatic disease is controversial, based on its questionable yield paired with concerns regarding the risks of radiation exposure, cost, and morbidity resulting from false positive findings.

Methods

Through retrospective review of 140 patients of all ages (mean 53 years; 2 to 88) diagnosed with soft-tissue sarcoma of the extremity with a mean follow-up of 33 months (0 to 291), we sought to determine the overall incidence of isolated abdominopelvic metastases, their temporal relationship to chest involvement, the rate of false positives, and to identify disparate rates of metastases based on sarcoma subtype.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 324 - 328
1 Mar 2015
Boddu CK Arif SK Hussain MM Sankaranarayanan S Hameed S Sujir PR

Graft-tunnel mismatch of the bone-patellar tendon-bone (BPTB) graft is a major concern during anatomical anterior cruciate ligament (ACL) reconstruction if the femoral tunnel is positioned using a far medial portal technique, as the femoral tunnel tends to be shorter compared with that positioned using a transtibial portal technique. This study describes an accurate method of calculating the ideal length of bone plugs of a BPTB graft required to avoid graft–tunnel mismatch during anatomical ACL reconstruction using a far medial portal technique of femoral tunnel positioning.

Based on data obtained intra-operatively from 60 anatomical ACL reconstruction procedures, we calculated the length of bone plugs required in the BPTB graft to avoid graft–tunnel mismatch. When this was prevented in all the 60 cases, we found that the mean length of femoral bone plug that remained in contact with the interference screw within the femoral tunnel was 14 mm (12 to 22) and the mean length of tibial bone plug that remained in contact with the interference screw within the tibial tunnel was 23 mm (18 to 28). These results were used to validate theoretical formulae developed to predict the required length of bone plugs in BPTB graft during anatomical ACL reconstruction using a far medial portal technique.

Cite this article: Bone Joint J 2015;97-B:324–8.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 420 - 426
1 Mar 2015
Martinkevich P Møller-Madsen B Gottliebsen M Kjeldgaard Pedersen L Rahbek O

We present the validation of a translation into Danish of the Oxford ankle foot questionnaire (OxAFQ). We followed the Isis Pros guidelines for translation and pilot-tested the questionnaire on ten children and their parents. Following modifications we tested the validity of the final questionnaire on 82 children (36 boys and 45 girls) with a mean age of 11.7 years (5.5 to 16.0) and their parents. We tested the reliability (repeatability (test–retest), child–parent agreement, internal consistency), feasibility (response rate, time to completion, floor and ceiling effects) and construct validity. The generic child health questionnaire was used for comparison. We found good internal consistency for the physical and the school and play domains, but lower internal consistency for the emotional domain. Overall, good repeatability was found within children and parents as well as agreement between children and parents. The OxAFQ was fast and easy to complete, but we observed a tendency towards ceiling effects in the school and play and emotional domains. To our knowledge this is the first independent validation of the OxAFQ in any language. We found it valid and feasible for use in the clinic to assess the impact on children’s lives of foot and/or ankle disorders. It is a valuable research tool.

Cite this article: Bone Joint J 2015;97-B:420–6.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 432 - 432
1 Mar 2015
Haddad FS

DF Hamilton, R Burnett, JT Patton, CR Howie, M Moran, AHRW Simpson, P Gaston. Implant design influences patient outcome after total knee arthroplasty. Bone Joint J 2015;97-B:64–70.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 289 - 290
1 Mar 2015
Haddad FS


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 329 - 336
1 Mar 2015
Tigchelaar S van Essen P Bénard M Koëter S Wymenga A

An increased tibial tubercle–trochlear groove (TT-TG) distance is related to patellar maltracking and instability. Tibial tubercle transfer is a common treatment option for these patients with good short-term results, although the results can deteriorate over time owing to the progression of osteoarthritis. We present a ten-year follow-up study of a self-centring tibial tubercle osteotomy in 60 knees, 30 with maltracking and 30 with patellar instability. Inclusion criteria were a TT-TG ≥ 15 mm and symptoms for > one year. One patient (one knee) was lost to follow-up and one required total knee arthroplasty because of progressive osteoarthritis. Further patellar dislocations occurred in three knees, all in the instability group, one of which required further surgery. The mean visual analogue scores for pain, and Lysholm and Kujala scores improved significantly and were maintained at the final follow-up (repeated measures, p = 0.000, intergroup differences p = 0.449). Signs of maltracking were found in only a minority of patients, with no difference between groups (p > 0.05). An increase in patellofemoral osteoarthritis was seen in 16 knees (31%) with a maximum of grade 2 on the Kellgren–Lawrence scale. The mean increase in grades was 0.31 (0 to 2) and 0.41 (0 to 2) in the maltracking and instability groups respectively (p = 0.2285)

This self-centring tibial tubercle osteotomy provides good results at ten years’ follow-up without inducing progressive osteoarthritis.

Cite this article: Bone Joint J 2015;97-B:329–36.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 383 - 390
1 Mar 2015
Mariconda M Costa GG Cerbasi S Recano P Aitanti E Gambacorta M Misasi M

Several studies have reported the rate of post-operative mortality after the surgical treatment of a fracture of the hip, but few data are available regarding the delayed morbidity. In this prospective study, we identified 568 patients who underwent surgery for a fracture of the hip and who were followed for one year. Multivariate analysis was carried out to identify possible predictors of mortality and morbidity. The 30-day, four-month and one-year rates of mortality were 4.3%, 11.4%, and 18.8%, respectively. General complications and pre-operative comorbidities represented the basic predictors of mortality at any time interval (p < 0.01). In-hospital, four-month and one-year general complications occurred in 29.4%, 18.6% and 6.7% of patients, respectively. After adjusting for confounding variables, comorbidities and poor cognitive status determined the likelihood of early and delayed general complications, respectively (p < 0.001). Operative delay was the main predictor of the length of hospital stay (p < 0.001) and was directly related to in-hospital (p = 0.017) and four-month complications (p = 0.008).

Cite this article: Bone Joint J 2015;97-B:383–90


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation.

Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures.

This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation.

Cite this article: Bone Joint J 2015;97-B:391–7.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 337 - 345
1 Mar 2015
Jaroma AVJ Soininvaara TA Kröger H

Total knee arthroplasty (TKA) is known to lead to a reduction in periprosthetic bone mineral density (BMD). In theory, this may lead to migration, instability and aseptic loosening of the prosthetic components. Bisphosphonates inhibit bone resorption and may reduce this loss in BMD. We hypothesised that treatment with bisphosphonates and calcium would lead to improved BMD and clinical outcomes compared with treatment with calcium supplementation alone following TKA. A total of 26 patients, (nine male and 17 female, mean age 67 years) were prospectively randomised into two study groups: alendronate and calcium (bisphosphonate group, n = 14) or calcium only (control group, n = 12). Dual energy X-ray absorptiometry (DEXA) measurements were performed post-operatively, and at three months, six months, one, two, four, and seven years post-operatively.

Mean femoral metaphyseal BMD was significantly higher in the bisphosphonate group compared with controls, up to four years following surgery in some areas of the femur (p = 0.045). BMD was observed to increase in the lateral tibial metaphysis in the bisphosphonate group until seven years (p = 0.002), and was significantly higher than that observed in the control group throughout (p = 0.024). There were no significant differences between the groups in the central femoral metaphyseal, tibial medial metaphyseal or diaphyseal regions of interest (ROI) of either the femur or tibia.

Bisphosphonate treatment after TKA may be of benefit for patients with poor bone quality. However, further studies with a larger number of patients are necessary to assess whether this is clinically beneficial.

Cite this article: Bone Joint J 2015;97-B:337–45.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 160 - 163
1 Feb 2015
Biemond JE Venkatesan S van Hellemondt GG

The long-term survival of the cementless Spotorno CLS femoral component in patients aged > 50 years at the time of arthroplasty was investigated. Survivorship analysis of a consecutive series of 85 patients (100 hips; under 50 years of age at a mean follow-up of 18.4 years (16.3 to 20.8)) was performed. The clinical and radiographic outcomes were satisfactory. The overall rate of survival of the femoral component was 93.5% (95% confidence interval (CI), 90.9 to 96.1) after 19 years. Survival with revision for aseptic loosening as the end point was 95.7% (95% CI 93.6 to 97.8%) at 19 years.

This study demonstrates an excellent long-term survival of the Spotorno CLS femoral component after 16 to 20 years in young patients undergoing total hip arthroplasty.

Cite this article: Bone Joint J 2015;97-B:160–3.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 240 - 245
1 Feb 2015
Ramaesh R Clement ND Rennie L Court-Brown C Gaston MS

Paediatric fractures are common and can cause significant morbidity. Socioeconomic deprivation is associated with an increased incidence of fractures in both adults and children, but little is known about the epidemiology of paediatric fractures. In this study we investigated the effect of social deprivation on the epidemiology of paediatric fractures.

We compiled a prospective database of all fractures in children aged < 16 years presenting to the study centre. Demographics, type of fracture, mode of injury and postcode were recorded. Socioeconomic status quintiles were assigned for each child using the Scottish Index for Multiple Deprivation (SIMD).

We found a correlation between increasing deprivation and the incidence of fractures (r = 1.00, p < 0.001). In the most deprived group the incidence was 2420/100 000/yr, which diminished to 1775/100 000/yr in the least deprived group.

The most deprived children were more likely to suffer a fracture as a result of a fall (odds ratio (OR) = 1.5, p < 0.0001), blunt trauma (OR = 1.5, p = 0.026) or a road traffic accident (OR = 2.7, p < 0.0001) than the least deprived.

These findings have important implications for public health and preventative measures.

Cite this article: Bone Joint J 2015;97-B:240–5.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 235 - 239
1 Feb 2015
Prime M Al-Obaidi B Safarfashandi Z Lok Y Mobasheri R Akmal M

This study examined spinal fractures in patients admitted to a Major Trauma Centre via two independent pathways, a major trauma (MT) pathway and a standard unscheduled non-major trauma (NMT) pathway. A total of 134 patients were admitted with a spinal fracture over a period of two years; 50% of patients were MT and the remainder NMT. MT patients were predominantly male, had a mean age of 48.8 years (13 to 95), commonly underwent surgery (62.7%), characteristically had fractures in the cervico-thoracic and thoracic regions and 50% had fractures of more than one vertebrae, which were radiologically unstable in 70%. By contrast, NMT patients showed an equal gender distribution, were older (mean 58.1 years; 12 to 94), required fewer operations (56.7%), characteristically had fractures in the lumbar region and had fewer multiple and unstable fractures. This level of complexity was reflected in the length of stay in hospital; MT patients receiving surgery were in hospital for a mean of three to four days longer than NMT patients. These results show that MT patients differ from their NMT counterparts and have an increasing complexity of spinal injury.

Cite this article: Bone Joint J 2015;97-B:235–9.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 18 - 20
1 Feb 2015

The February 2015 Foot & Ankle Roundup360 looks at: Syndesmosis screw removal in randomised controlled trial; Diagnostic value of Hawkins sign; Chevron rules supreme?; Diabetes and ankle replacement; Fixed-bearing ankle replacement; Fusion for osteomyelitis of the ankle; ‘Reformed’ fallers.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 26 - 28
1 Feb 2015

The February 2015 Trauma Roundup360 looks at: Evaluating the syndesmosis in ankle fractures; Calcaneal fracture management an ongoing problem; Angular stable locking in low tibial fractures did not improve results; Open fractures: do the seconds really count?; Long-term outcomes of tibial fractures; Targeted performance improvements in pelvic fractures


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 173 - 176
1 Feb 2015
Omar M Ettinger M Reichling M Petri M Guenther D Gehrke T Krettek C Mommsen P

The aim of this study was to assess the role of synovial C-reactive protein (CRP) in the diagnosis of chronic periprosthetic hip infection. We prospectively collected synovial fluid from 89 patients undergoing revision hip arthroplasty and measured synovial CRP, serum CRP, erythrocyte sedimentation rate (ESR), synovial white blood cell (WBC) count and synovial percentages of polymorphonuclear neutrophils (PMN). Patients were classified as septic or aseptic by means of clinical, microbiological, serum and synovial fluid findings. The high viscosity of the synovial fluid precluded the analyses in nine patients permitting the results in 80 patients to be studied. There was a significant difference in synovial CRP levels between the septic (n = 21) and the aseptic (n = 59) cohort. According to the receiver operating characteristic curve, a synovial CRP threshold of 2.5 mg/l had a sensitivity of 95.5% and specificity of 93.3%. The area under the curve was 0.96. Compared with serum CRP and ESR, synovial CRP showed a high diagnostic value. According to these preliminary results, synovial CRP may be a useful parameter in diagnosing chronic periprosthetic hip infection.

Cite this article: Bone Joint J 2015; 97-B:173–6.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 164 - 172
1 Feb 2015
Grammatopoulos G Thomas GER Pandit H Beard DJ Gill HS Murray DW

We assessed the orientation of the acetabular component in 1070 primary total hip arthroplasties with hard-on-soft, small diameter bearings, aiming to determine the size and site of the target zone that optimises outcome. Outcome measures included complications, dislocations, revisions and ΔOHS (the difference between the Oxford Hip Scores pre-operatively and five years post-operatively). A wide scatter of orientation was observed (2sd 15°). Placing the component within Lewinnek’s zone was not associated withimproved outcome. Of the different zone sizes tested (± 5°, ± 10° and ± 15°), only ± 15° was associated with a decreased rate of dislocation. The dislocation rate with acetabular components inside an inclination/anteversion zone of 40°/15° ± 15° was four times lower than those outside. The only zone size associated with statistically significant and clinically important improvement in OHS was ± 5°. The best outcomes (ΔOHS > 26) were achieved with a 45°/25° ± 5° zone.

This study demonstrated that with traditional technology surgeons can only reliably achieve a target zone of ±15°. As the optimal zone to diminish the risk of dislocation is also ±15°, surgeons should be able to achieve this. This is the first study to demonstrate that optimal orientation of the acetabular component improves the functional outcome. However, the target zone is small (± 5°) and cannot, with current technology, be consistently achieved.

Cite this article: Bone Joint J 2015;97-B:164–72.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 2 - 5
1 Feb 2015
Wright GM Porteous MJ


Moderate to severe hallux valgus is conventionally treated by proximal metatarsal osteotomy. Several recent studies have shown that the indications for distal metatarsal osteotomy with a distal soft-tissue procedure could be extended to include moderate to severe hallux valgus.

The purpose of this prospective randomised controlled trial was to compare the outcome of proximal and distal Chevron osteotomy in patients undergoing simultaneous bilateral correction of moderate to severe hallux valgus.

The original study cohort consisted of 50 female patients (100 feet). Of these, four (8 feet) were excluded for lack of adequate follow-up, leaving 46 female patients (92 feet) in the study. The mean age of the patients was 53.8 years (30.1 to 62.1) and the mean duration of follow-up 40.2 months (24.1 to 80.5). After randomisation, patients underwent a proximal Chevron osteotomy on one foot and a distal Chevron osteotomy on the other.

At follow-up, the American Orthopedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal interphalangeal (MTP-IP) score, patient satisfaction, post-operative complications, hallux valgus angle, first-second intermetatarsal angle, and tibial sesamoid position were similar in each group. Both procedures gave similar good clinical and radiological outcomes.

This study suggests that distal Chevron osteotomy with a distal soft-tissue procedure is as effective and reliable a means of correcting moderate to severe hallux valgus as proximal Chevron osteotomy with a distal soft-tissue procedure.

Cite this article: Bone Joint J 2015;97-B:202–7.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 252 - 257
1 Feb 2015
Wafa H Grimer RJ Reddy K Jeys L Abudu A Carter SR Tillman RM

We conducted a case-control study to examine the merit of silver-coated tumour prostheses. We reviewed 85 patients with Agluna-treated (silver-coated) tumour implants treated between 2006 and 2011 and matched them with 85 control patients treated between 2001 and 2011 with identical, but uncoated, tumour prostheses.

In all, 106 men and 64 women with a mean age of 42.2 years (18.4 to 90.4) were included in the study. There were 50 primary reconstructions (29.4%); 79 one-stage revisions (46.5%) and 41 two-stage revisions for infection (24.1%).

The overall post-operative infection rate of the silver-coated group was 11.8% compared with 22.4% for the control group (p = 0.033, chi-square test). A total of seven of the ten infected prostheses in the silver-coated group were treated successfully with debridement, antibiotics, and implant retention compared with only six of the 19 patients (31.6%) in the control group (p = 0.048, chi-square test). Three patients in the silver-coated group (3.5%) and 13 controls (15.3%) had chronic periprosthetic infection (p = 0.009, chi-square test).

The overall success rates in controlling infection by two-stage revision in the silver-coated group was 85% (17/20) compared with 57.1% (12/21) in the control group (p = 0.05, chi-square test). The Agluna-treated endoprostheses were associated with a lower rate of early periprosthetic infection. These silver-treated implants were particularly useful in two-stage revisions for infection and in those patients with incidental positive cultures at the time of implantation of the prosthesis.

Debridement with antibiotic treatment and retention of the implant appeared to be more successful with silver-coated implants.

Cite this article: Bone Joint J 2015;97-B:252–7.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 1 - 1
1 Feb 2015
Ollivere B


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 277 - 282
1 Feb 2015
Shetty RP Mathew M Smith J Morse LP Mehta JA Currie BJ

Little information is available about several important aspects of the treatment of melioidosis osteomyelitis and septic arthritis.

We undertook a retrospective review of 50 patients with these conditions in an attempt to determine the effect of location of the disease, type of surgical intervention and duration of antibiotic treatment on outcome, particularly complications and relapse.

We found that there was a 27.5% risk of osteomyelitis of the adjacent bone in patients with septic arthritis in the lower limb. Patients with septic arthritis and osteomyelitis of an adjacent bone were in hospital significantly longer (p = 0.001), needed more operations (p = 0.031) and had a significantly higher rate of complications and re-presentation (p = 0.048).

More than half the patients (61%), most particularly those with multifocal bone and joint involvement, and those with septic arthritis and osteomyelitis of an adjacent bone who were treated operatively, needed more visits to theatre.

Cite this article: Bone Joint J 2015;97-B:277–82.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 32 - 33
1 Feb 2015

The February 2015 Research Roundup360 looks at: Markers of post-traumatic ankle arthritis; Mangoes, trees and Solomon Islanders; Corticosteroid injection and ulnar neuropathy; Moral decision-making: the secret skill?; Biomechanical studies under the spotlight; Anaesthetic risk and hip replacement


Bone & Joint 360
Vol. 4, Issue 1 | Pages 37 - 39
1 Feb 2015
Gwilym SE Stace RM


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 154 - 159
1 Feb 2015
Halai M Gupta S Gilmour A Bharadwaj R Khan A Holt G

We evaluated an operative technique, described by the Exeter Hip Unit, to assist accurate introduction of the femoral component. We assessed whether it led to a reduction in the rate of leg-length discrepancy after total hip arthroplasty (THA).

A total of 100 patients undergoing THA were studied retrospectively; 50 were undertaken using the test method and 50 using conventional methods as a control group. The groups were matched with respect to patient demographics and the grade of surgeon. Three observers measured the depth of placement of the femoral component on post-operative radiographs and measured the length of the legs.

There was a strong correlation between the depth of insertion of the femoral component and the templated depth in the test group (R = 0.92), suggesting accuracy of the technique. The mean leg-length discrepancy was 5.1 mm (0.6 to 21.4) pre-operatively and 1.3 mm (0.2 to 9.3) post-operatively. There was no difference between Consultants and Registrars as primary surgeons. Agreement between the templated and post-operative depth of insertion was associated with reduced post-operative leg-length discrepancy. The intra-class coefficient was R ≥ 0.88 for all measurements, indicating high observer agreement. The post-operative leg-length discrepancy was significantly lower in the test group (1.3 mm) compared with the control group (6.3 mm, p < 0.001).

The Exeter technique is reproducible and leads to a lower incidence of leg-length discrepancy after THA.

Cite this article: Bone Joint J 2015;97-B:154–9.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 265 - 269
1 Feb 2015
Mace J Paton RW

Over a 15-year prospective period, 201 infants with a clinically unstable hip at neonatal screening were subsequently reviewed in a ‘one stop’ clinic where they were assessed clinically and sonographically. Their mean age was 1.62 weeks (95% confidence interval (CI) 1.35 to 1.89). Clinical neonatal hip screening revealed a sensitivity of 62% (mean, 62.6 95%CI 50.9 to 74.3), specificity of 99.8% (mean, 99.8, 95% CI 99.7 to 99.8) and positive predictive value (PPV) of 24% (mean, 26.2, 95% CI 19.3 to 33.0). Static and dynamic sonography for Graf type IV dysplastic hips had a 15-year sensitivity of 77% (mean, 75.8 95% CI 66.9 to 84.6), specificity of 99.8% (mean, 99.8, 95% CI 99.8 to 99.8) and a PPV of 49% (mean, 55.1, 95% CI 41.6 to 68.5). There were 36 infants with an irreducible dislocation of the hip (0.57 per 1000 live births), including six that failed to resolve with neonatal splintage.

Most clinically unstable hips referred to a specialist clinic are female and stabilise spontaneously. Most irreducible dislocations are not identified from this neonatal instability group. There may be a small subgroup of females with instability of the hip which may be at risk of progression to irreducibility despite early treatment in a Pavlik harness.

A controlled study is required to assess the value of neonatal clinical screening programmes.

Cite this article: Bone Joint J 2015;97-B:265-9.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 221 - 228
1 Feb 2015
Zhang X Li Y Wen S Zhu H Shao X Yu Y

We report a new surgical technique of open carpal tunnel release with subneural reconstruction of the transverse carpal ligament and compare this with isolated open and endoscopic carpal tunnel release.

Between December 2007 and October 2011, 213 patients with carpal tunnel syndrome (70 male, 143 female; mean age 45.6 years; 29 to 67) were recruited from three different centres and were randomly allocated to three groups: group A, open carpal tunnel release with subneural reconstruction of the transverse carpal ligament (n = 68); group B, isolated open carpal tunnel release (n = 92); and group C, endoscopic carpal tunnel release (n = 53).

At a mean final follow-up of 24 months (22 to 26), we found no significant difference between the groups in terms of severity of symptoms or lateral grip strength. Compared with groups B and C, group A had significantly better functional status, cylindrical grip strength and pinch grip strength. There were significant differences in Michigan Hand Outcome scores between groups A and B, A and C, and B and C. Group A had the best functional status, cylindrical grip strength, pinch grip strength and Michigan Hand Outcome score.

Subneural reconstruction of the transverse carpal ligament during carpal tunnel decompression maximises hand strength by stabilising the transverse carpal arch.

Cite this article: Bone Joint J 2015;97-B:221–8


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 185 - 191
1 Feb 2015
Kendrick BJL Kaptein BL Valstar ER Gill HS Jackson WFM Dodd CAF Price AJ Murray DW

The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs.

A total of 43 patients were randomised to receive either a cemented or a cementless Oxford UKA and were followed for two years with radiostereometric analysis (RSA), radiographs aligned with the bone–implant interfaces and clinical scores.

The femoral components migrated significantly during the first year (mean 0.2 mm) but not during the second. There was no significant difference in the extent of migration between cemented and cementless femoral components in either the first or the second year. In the first year the cementless tibial components subsided significantly more than the cemented components (mean 0.28 mm (sd 0.17) vs. 0.09 mm (sd 0.19 mm)). In the second year, although there was a small amount of subsidence (mean 0.05 mm) there was no significant difference (p = 0.92) between cemented and cementless tibial components. There were no femoral radiolucencies. Tibial radiolucencies were narrow (< 1 mm) and were significantly (p = 0.02) less common with cementless (6 of 21) than cemented (13 of 21) components at two years. There were no complete radiolucencies with cementless components, whereas five of 21 (24%) cemented components had complete radiolucencies. The clinical scores at two years were not significantly different (p = 0.20).

As second-year migration is predictive of subsequent loosening, and as radiolucency is suggestive of reduced implant–bone contact, these data suggest that fixation of the cementless components is at least as good as, if not better than, that of cemented devices.

Cite this article: Bone Joint J 2015; 97-B:185–91.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 246 - 251
1 Feb 2015
Chatterton BD Moores TS Ahmad S Cattell A Roberts PJ

The aims of this study were to identify the early in-hospital mortality rate after hip fracture, identify factors associated with this mortality, and identify the cause of death in these patients. A retrospective cohort study was performed on 4426 patients admitted to our institution between the 1 January 2006 and 31 December 2013 with a hip fracture (1128 male (26%), mean age 82.0 years (60 to 105)).

Admissions increased annually, but despite this 30-day mortality decreased from 12.1% to 6.5%; 77% of these were in-hospital deaths. Male gender (odds ratio (OR) 2.0, 95% confidence interval (CI) 1.3 to 3.0), increasing age (age ≥ 91; OR 4.1, 95% CI 1.4 to 12.2) and comorbidity (American Society of Anesthesiologists grades 3 to 5; OR 4.2, 95% CI 2.0 to 8.7) were independently and significantly associated with increased odds of in-hospital mortality. From 220 post-mortem reports, the most common causes of death were respiratory infections (35%), ischaemic heart disease (21%), and cardiac failure (13%). A sub-group of hip fracture patients at highest risk of early death can be identified with these risk factors, and the knowledge of the causes of death can be used to inform service improvements and the development of a more didactic care pathway, so that multidisciplinary intervention can be focused for this sub-group in order to improve their outcome.

Cite this article: Bone Joint J 2015;97-B:246–51.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 14 - 16
1 Feb 2015

The February 2015 Hip & Pelvis Roundup360 looks at: Hip arthroplasty in Down syndrome; Bulk femoral autograft successful in acetabular reconstruction; Arthroplasty follow-up: is the internet the solution?; Total hip arthroplasty following acetabular fracture; Salvage arthroplasty following failed hip internal fixation; Bone banking sensible financially and clinically; Allogenic blood transfusion in arthroplasty.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 20 - 22
1 Feb 2015

The February 2015 Wrist & Hand Roundup360 looks at: Toes, feet, hands and transfers… FCR Tendonitis after Trapeziectomy and suspension, Motion sparing surgery for SLAC/SNAC wrists under the spotlight, Instability following distal radius fractures, Bilateral wrist arthrodesis a good idea?, Sodium Hyaluronate improves hand recovery following flexor tendon repair, Ultrasound treatments for de Quervain’s, Strategies for treating metacarpal neck fractures.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 270 - 276
1 Feb 2015
Koch A Jozwiak M Idzior M Molinska-Glura M Szulc A

We investigated the incidence and risk factors for the development of avascular necrosis (AVN) of the femoral head in the course of treatment of children with cerebral palsy (CP) and dislocation of the hip. All underwent open reduction, proximal femoral and Dega pelvic osteotomy. The inclusion criteria were: a predominantly spastic form of CP, dislocation of the hip (migration percentage, MP > 80%), Gross Motor Function Classification System, (GMFCS) grade IV to V, a primary surgical procedure and follow-up of > one year.

There were 81 consecutive children (40 girls and 41 boys) in the study. Their mean age was nine years (3.5 to 13.8) and mean follow-up was 5.5 years (1.6 to 15.1). Radiological evaluation included measurement of the MP, the acetabular index (AI), the epiphyseal shaft angle (ESA) and the pelvic femoral angle (PFA). The presence and grade of AVN were assessed radiologically according to the Kruczynski classification.

Signs of AVN (grades I to V) were seen in 79 hips (68.7%). A total of 23 hips (18%) were classified between grades III and V.

Although open reduction of the hip combined with femoral and Dega osteotomy is an effective form of treatment for children with CP and dislocation of the hip, there were signs of avascular necrosis in about two-thirds of the children. There was a strong correlation between post-operative pain and the severity of the grade of AVN.

Cite this article: Bone Joint J 2015;97-B:270–6.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 208 - 214
1 Feb 2015
Chong A Nazarian N Chandrananth J Tacey M Shepherd D Tran P

This study sought to determine the medium-term patient-reported and radiographic outcomes in patients undergoing surgery for hallux valgus. A total of 118 patients (162 feet) underwent surgery for hallux valgus between January 2008 and June 2009. The Manchester-Oxford Foot Questionnaire (MOXFQ), a validated tool for the assessment of outcome after surgery for hallux valgus, was used and patient satisfaction was sought. The medical records and radiographs were reviewed retrospectively. At a mean of 5.2 years (4.7 to 6.0) post-operatively, the median combined MOXFQ score was 7.8 (IQR:0 to 32.8). The median domain scores for pain, walking/standing, and social interaction were 10 (IQR: 0 to 45), 0 (IQR: 0 to 32.1) and 6.3 (IQR: 0 to 25) respectively. A total of 119 procedures (73.9%, in 90 patients) were reported as satisfactory but only 53 feet (32.7%, in 43 patients) were completely asymptomatic. The mean (SD) correction of hallux valgus, intermetatarsal, and distal metatarsal articular angles was 18.5° (8.8°), 5.7° (3.3°), and 16.6° (8.8°), respectively. Multivariable regression analysis identified that an American Association of Anesthesiologists grade of > 1 (Incident Rate Ratio (IRR) = 1.67, p-value = 0.011) and recurrent deformity (IRR = 1.77, p-value = 0.003) were associated with significantly worse MOXFQ scores. No correlation was found between the severity of deformity, the type, or degree of surgical correction and the outcome. When using a validated outcome score for the assessment of outcome after surgery for hallux valgus, the long-term results are worse than expected when compared with the short- and mid-term outcomes, with 25.9% of patients dissatisfied at a mean follow-up of 5.2 years.

Cite this article: Bone Joint J 2015;97-B:208–14.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 150 - 153
1 Feb 2015
Rogers BA Alolabi B Carrothers AD Kreder HJ Jenkinson RJ

In this study we evaluated whether pre-operative Western Ontario and McMaster Universities (WOMAC) osteoarthritis scores can predict satisfaction following total hip arthroplasty (THA). Prospective data for a cohort of patients undergoing THA from two large academic centres were collected, and pre-operative and one-year post-operative WOMAC scores and a 25-point satisfaction questionnaire were obtained for 446 patients. Satisfaction scores were dichotomised into either improvement or deterioration. Scatter plots and Spearman’s rank correlation coefficient were used to describe the association between pre-operative WOMAC and one-year post-operative WOMAC scores and patient satisfaction. Satisfaction was compared using receiver operating characteristic (ROC) analysis against pre-operative, post-operative and δ WOMAC scores.

We found no relationship between pre-operative WOMAC scores and one-year post-operative WOMAC or satisfaction scores, with Spearman’s rank correlation coefficients of 0.16 and –0.05, respectively. The ROC analysis showed areas under the curve (AUC) of 0.54 (pre-operative WOMAC), 0.67 (post-operative WOMAC) and 0.43 (δ WOMAC), respectively, for an improvement in satisfaction.

We conclude that the pre-operative WOMAC score does not predict the post-operative WOMAC score or patient satisfaction after THA, and that WOMAC scores can therefore not be used to prioritise patient care.

Cite this article: Bone Joint J 2015;97-B:150–3.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 28 - 29
1 Feb 2015

The February 2015 Oncology Roundup360 looks at: Achieving global collaboration; A new standard for limb salvage; Inoperable chondrosarcoma and chemotherapy; Soft-tissue sarcoma and adjuvant chemotherapy; Missed diagnoses and malpractice in sarcoma; Radiofrequency and cartilage tumours


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 283 - 288
1 Feb 2015
Gupta S Maclean M Anderson JG MacGregor SJ Meek RMD Grant MH

High-intensity narrow-spectrum (HINS) light is a novel violet-blue light inactivation technology which kills bacteria through a photodynamic process, and has been shown to have bactericidal activity against a wide range of species. Specimens from patients with infected hip and knee arthroplasties were collected over a one-year period (1 May 2009 to 30 April 2010). A range of these microbial isolates were tested for sensitivity to HINS-light. During testing, suspensions of the pathogens were exposed to increasing doses of HINS-light (of 123mW/cm2 irradiance). Non-light exposed control samples were also used. The samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration. Complete inactivation (greater than 4-log10 reduction) was achieved for all of the isolates. The typical inactivation curve showed a slow initial reaction followed by a rapid period of inactivation. The doses of HINS-light required ranged between 118 and 2214 J/cm2. Gram-positive bacteria were generally found to be more susceptible than Gram-negative.

As HINS-light uses visible wavelengths, it can be safely used in the presence of patients and staff. This unique feature could lead to its possible use in the prevention of infection during surgery and post-operative dressing changes.

Cite this article: Bone Joint J 2015;97-B:283–8.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 16 - 18
1 Feb 2015

The February 2015 Knee Roundup360 looks at: Intra-operative sensors for knee balance; Mobile bearing no advantage; Death and knee replacement: a falling phenomenon; The swings and roundabouts of unicompartmental arthroplasty; Regulation, implants and innovation; The weight of arthroplasty responsibility!; BMI in arthroplasty


Bone & Joint 360
Vol. 4, Issue 1 | Pages 6 - 11
1 Feb 2015
Manktelow A Bloch B

This review examines the future of total hip arthroplasty, aiming to avoid past mistakes


Bone & Joint 360
Vol. 4, Issue 1 | Pages 29 - 31
1 Feb 2015

The February 2015 Children’s orthopaedics Roundup360 looks at: Hip dislocation in children with CTEV: two decades of experience; Population-based prevention of DDH in cerebral palsy: 20 years’ experience; Shoulder derotation in congenital plexus palsy; Back pain in the paediatric population: could MRI be the answer?; Intercondylar fracture of the humerus in children; The Dunn osteotomy in SUFE; Radiocapitellar line a myth!; Do ‘flatfooted’ children suffer?


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 197 - 201
1 Feb 2015
Kallala RF Vanhegan IS Ibrahim MS Sarmah S Haddad FS

Revision total knee arthroplasty (TKA) is a complex procedure which carries both a greater risk for patients and greater cost for the treating hospital than does a primary TKA. As well as the increased cost of peri-operative investigations, blood transfusions, surgical instrumentation, implants and operating time, there is a well-documented increased length of stay which accounts for most of the actual costs associated with surgery.

We compared revision surgery for infection with revision for other causes (pain, instability, aseptic loosening and fracture). Complete clinical, demographic and economic data were obtained for 168 consecutive revision TKAs performed at a tertiary referral centre between 2005 and 2012.

Revision surgery for infection was associated with a mean length of stay more than double that of aseptic cases (21.5 vs 9.5 days, p < 0.0001). The mean cost of a revision for infection was more than three times that of an aseptic revision (£30 011 (sd 4514) vs £9655 (sd 599.7), p < 0.0001).

Current NHS tariffs do not fully reimburse the increased costs of providing a revision knee surgery service. Moreover, especially as greater costs are incurred for infected cases. These losses may adversely affect the provision of revision surgery in the NHS.

Cite this article: Bone Joint J 2015;97-B:197–201.


Bone & Joint Research
Vol. 4, Issue 2 | Pages 23 - 28
1 Feb 2015
Auston DA Werner FW Simpson RB

Objectives

This study tests the biomechanical properties of adjacent locked plate constructs in a femur model using Sawbones. Previous studies have described biomechanical behaviour related to inter-device distances. We hypothesise that a smaller lateral inter-plate distance will result in a biomechanically stronger construct, and that addition of an anterior plate will increase the overall strength of the construct.

Methods

Sawbones were plated laterally with two large-fragment locking compression plates with inter-plate distances of 10 mm or 1 mm. Small-fragment locking compression plates of 7-hole, 9-hole, and 11-hole sizes were placed anteriorly to span the inter-plate distance. Four-point bend loading was applied, and the moment required to displace the constructs by 10 mm was recorded.


Bone & Joint Research
Vol. 4, Issue 2 | Pages 11 - 16
1 Feb 2015
C. Wyatt M Wright T Locker J Stout K Chapple C Theis JC

Objectives

Effective analgesia after total knee arthroplasty (TKA) improves patient satisfaction, mobility and expedites discharge. This study assessed whether continuous femoral nerve infusion (CFNI) was superior to a single-shot femoral nerve block in primary TKA surgery completed under subarachnoid blockade including morphine.

Methods

We performed an adequately powered, prospective, randomised, placebo-controlled trial comparing CFNI of 0.125% bupivacaine versus normal saline following a single-shot femoral nerve block and subarachnoid anaesthesia with intrathecal morphine for primary TKA. Patients were randomised to either treatment (CFNI 0 ml to 10 ml/h 0.125% bupivacaine) or placebo (CFNI 0 ml to 10 ml/h normal saline). Both groups received a single-shot femoral nerve block (0.25% 20 ml bupivacaine) prior to placement of femoral nerve catheter and subarachnoid anaesthesia with intrathecal morphine. All patients had a standardised analgesic protocol. The primary end point was post-operative visual analogue scale (VAS) pain score over 72 hours post-surgery. Secondary outcomes were morphine equivalent dose, range of movement, side effects, and length of stay.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 192 - 196
1 Feb 2015
Bernhoff K Björck M

We have investigated iatrogenic popliteal artery injuries (PAI) during non arthroplasty knee surgery regarding mechanism of injury, treatment and outcomes, and to identify successful strategies when injury occurs.

In all, 21 iatrogenic popliteal artery injuries in 21 patients during knee surgery other than knee arthroplasty were identified from the Swedish Vascular Registry (Swedvasc) between 1987 and 2011. Prospective registry data were supplemented with case-records, including long-term follow-up. In total, 13 patients suffered PAI during elective surgery and eight during urgent surgery such as fracture fixation or tumour resection. Nine injuries were detected intra-operatively, five within 12 to 48 hours and seven > 48 hours post-operatively (two days to 23 years).

There were 19 open vascular and two endovascular surgical repairs. Two patients died within six months of surgery. One patient required amputation. Only six patients had a complete recovery of whom had the vascular injury detected at time of injury and repaired by a vascular surgeon. Patients sustaining vascular injury during elective procedures are more likely to litigate (p = 0.029).

We conclude that outcomes are poorer when there is a delay of diagnosis and treatment, and that orthopaedic surgeons should develop strategies to detect PAI early and ensure rapid access to vascular surgical support.

Cite this article: Bone Joint J 2015;97-B:192–6.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 145 - 146
1 Feb 2015
Haddad FS


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 258 - 264
1 Feb 2015
Young PS Bell SW Mahendra A

We report our experience of using a computer navigation system to aid resection of malignant musculoskeletal tumours of the pelvis and limbs and, where appropriate, their subsequent reconstruction. We also highlight circumstances in which navigation should be used with caution.

We resected a musculoskeletal tumour from 18 patients (15 male, three female, mean age of 30 years (13 to 75) using commercially available computer navigation software (Orthomap 3D) and assessed its impact on the accuracy of our surgery. Of nine pelvic tumours, three had a biological reconstruction with extracorporeal irradiation, four underwent endoprosthetic replacement (EPR) and two required no bony reconstruction. There were eight tumours of the bones of the limbs. Four diaphyseal tumours underwent biological reconstruction. Two patients with a sarcoma of the proximal femur and two with a sarcoma of the proximal humerus underwent extra-articular resection and, where appropriate, EPR. One soft-tissue sarcoma of the adductor compartment which involved the femur was resected and reconstructed using an EPR. Computer navigation was used to aid reconstruction in eight patients.

Histological examination of the resected specimens revealed tumour-free margins in all patients. Post-operative radiographs and CT showed that the resection and reconstruction had been carried out as planned in all patients where navigation was used. In two patients, computer navigation had to be abandoned and the operation was completed under CT and radiological control.

The use of computer navigation in musculoskeletal oncology allows accurate identification of the local anatomy and can define the extent of the tumour and proposed resection margins. Furthermore, it helps in reconstruction of limb length, rotation and overall alignment after resection of an appendicular tumour.

Cite this article: Bone Joint J 2015;97-B:258–64.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 229 - 234
1 Feb 2015
Choi W Lee HJ Kim D Lee C Lee BG Kim J Lee K

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (sd 0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (sd 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (sd 12.2) in group 1 and 10.5 (sd 13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (sd 14.04) in group 1 and 82.6 (sd 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson’s correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient –0.26, p = 0.02).

We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome.

Cite this article: Bone Joint J 2015;97-B:229–34.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 177 - 184
1 Feb 2015
Felden A Vaz G Kreps S Anract P Hamadouche M Biau DJ

Conventional cemented acetabular components are reported to have a high rate of failure when implanted into previously irradiated bone. We recommend the use of a cemented reconstruction with the addition of an acetabular reinforcement cross to improve fixation.

We reviewed a cohort of 45 patients (49 hips) who had undergone irradiation of the pelvis and a cemented total hip arthroplasty (THA) with an acetabular reinforcement cross. All hips had received a minimum dose of 30 Gray (Gy) to treat a primary nearby tumour or metastasis. The median dose of radiation was 50 Gy (Q1 to Q3: 45 to 60; mean: 49.57, 32 to 72).

The mean follow-up after THA was 51 months (17 to 137). The cumulative probability of revision of the acetabular component for a mechanical reason was 0% (0 to 0%) at 24 months, 2.9% (0.2 to 13.3%) at 60 months and 2.9% (0.2% to 13.3%) at 120 months, respectively. One hip was revised for mechanical failure and three for infection.

Cemented acetabular components with a reinforcement cross provide good medium-term fixation after pelvic irradiation. These patients are at a higher risk of developing infection of their THA.

Cite this article: Bone Joint J 2015;97-B:177–84.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 215 - 220
1 Feb 2015
Soons J Rakhorst HA Ruettermann M Luijsterburg AJM Bos PK Zöphel OT

A total of seven patients (six men and one woman) with a defect in the Achilles tendon and overlying soft tissue underwent reconstruction using either a composite radial forearm flap (n = 3) or an anterolateral thigh flap (n = 4). The Achilles tendons were reconstructed using chimeric palmaris longus (n = 2) or tensor fascia lata (n = 2) flaps or transfer of the flexor hallucis longus tendon (n = 3). Surgical parameters such as the rate of complications and the time between the initial repair and flap surgery were analysed. Function was measured objectively by recording the circumference of the calf, the isometric strength of the plantar flexors and the range of movement of the ankle. The Achilles tendon Total Rupture Score (ATRS) questionnaire was used as a patient-reported outcome measure. Most patients had undergone several previous operations to the Achilles tendon prior to flap surgery. The mean time to flap surgery was 14.3 months (2.1 to 40.7).

At a mean follow-up of 32.3 months (12.1 to 59.6) the circumference of the calf on the operated lower limb was reduced by a mean of 1.9 cm (sd 0.74) compared with the contralateral limb (p = 0.042). The mean strength of the plantar flexors on the operated lower limb was reduced to 88.9% of that of the contralateral limb (p = 0.043). There was no significant difference in the range of movement between the two sides (p = 0.317). The mean ATRS score was 72 points (sd 20.0). One patient who had an initial successful reconstruction developed a skin defect of the composite flap 12 months after free flap surgery and this resulted in recurrent infections, culminating in transtibial amputation 44 months after reconstruction.

These otherwise indicate that reconstruction of the Achilles tendon combined with flap cover results in a successful and functional reconstruction.

Cite this article: Bone Joint J 2015;97-B:215–20.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 22 - 24
1 Feb 2015

The February 2015 Shoulder & Elbow Roundup360 looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow


Bone & Joint 360
Vol. 4, Issue 1 | Pages 35 - 36
1 Feb 2015
Ross A


Bone & Joint 360
Vol. 4, Issue 1 | Pages 24 - 26
1 Feb 2015

The February 2015 Spine Roundup360 looks at: Paracetamol use for lower back pain; En-bloc resection of vertebra reported for the first time; Spinopelvic disassociation under the spotlight; Hope for back pain; Disc replacement and ACDF equivalent in randomised study; Interspinous process devices ineffective


Bone & Joint Research
Vol. 4, Issue 2 | Pages 17 - 22
1 Feb 2015
Vo A Beaule PE Sampaio ML Rotaru C Rakhra KS

Objectives

The purpose of this study was to investigate whether the femoral head–neck contour, characterised by the alpha angle, varies with the stage of physeal maturation using MRI evaluation of an asymptomatic paediatric population.

Methods

Paediatric volunteers with asymptomatic hips were recruited to undergo MRI of both hips. Femoral head physes were graded from 1 (completely open) to 6 (completely fused). The femoral head–neck contour was evaluated using the alpha angle, measured at the 3:00 (anterior) and 1:30 (anterosuperior) positions and correlated with physeal grade, with gender sub-analysis performed.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 147 - 149
1 Feb 2015
Morgan-Jones R Oussedik SIS Graichen H Haddad FS

Revision knee arthroplasty presents a number of challenges, not least of which is obtaining solid primary fixation of implants into host bone. Three anatomical zones exist within both femur and tibia which can be used to support revision implants. These consist of the joint surface or epiphysis, the metaphysis and the diaphysis. The methods by which fixation in each zone can be obtained are discussed. The authors suggest that solid fixation should be obtained in at least two of the three zones and emphasise the importance of pre-operative planning and implant selection.

Cite this article: Bone Joint J 2015;97-B:147–9.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 104 - 108
1 Jan 2015
Bretherton CP Parker MJ

There has been extensive discussion about the effect of delay to surgery on mortality in patients sustaining a fracture of the hip. Despite the low level of evidence provided by many studies, a consensus has been accepted that delay of > 48 hours is detrimental to survival. The aim of this prospective observational study was to determine if early surgery confers a survival benefit at 30 days.

Between 1989 and 2013, data were prospectively collected on patients sustaining a fracture of the hip at Peterborough City Hospital. They were divided into groups according to the time interval between admission and surgery. These thresholds ranged from <  6 hours to between 49 and 72 hours. The outcome which was assessed was the 30-day mortality. Adjustment for confounders was performed using multivariate binary logistic regression analysis. In all, 6638 patients aged > 60 years were included.

Worsening American Society of Anaesthesiologists grade (p < 0.001), increased age (p <  0.001) and extracapsular fracture (p < 0.019) increased the risk of 30-day mortality.

Increasing mobility score (p = 0.014), mini mental test score (p < 0.001) and female gender (p = 0.014) improved survival. After adjusting for these confounders, surgery before 12 hours improved survival compared with surgery after 12 hours (p = 0.013). Beyond this the increasing delay to surgery did not significantly affect the 30-day mortality.

Cite this article: Bone Joint J 2015;97-B:104–8.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 89 - 93
1 Jan 2015
Maier GS Seeger JB Horas K Roth KE Kurth AA Maus U

Hypovitaminosis D has been identified as a common risk factor for fragility fractures and poor fracture healing. Epidemiological data on vitamin D deficiency have been gathered in various populations, but the association between vertebral fragility fractures and hypovitaminosis D, especially in males, remains unclear. The purpose of this study was to evaluate serum levels of 25-hydroxyvitamin D (25-OH D) in patients presenting with vertebral fragility fractures and to determine whether patients with a vertebral fracture were at greater risk of hypovitaminosis D than a control population. Furthermore, we studied the seasonal variations in the serum vitamin D levels of tested patients in order to clarify the relationship between other known risk factors for osteoporosis and vitamin D levels. We measured the serum 25-OH D levels of 246 patients admitted with vertebral fractures (105 men, 141 female, mean age 69 years, sd 8.5), and in 392 orthopaedic patients with back pain and no fractures (219 men, 173 female, mean age 63 years, sd 11) to evaluate the prevalence of vitamin D insufficiency. Statistical analysis found a significant difference in vitamin D levels between patients with vertebral fragility fracture and the control group (p = 0.036). In addition, there was a significant main effect of the tested variables: obesity (p < 0.001), nicotine abuse (p = 0.002) and diabetes mellitus (p < 0.001). No statistical difference was found between vitamin D levels and gender (p = 0.34). Vitamin D insufficiency was shown to be a risk factor for vertebral fragility fractures in both men and women.

Cite this article: Bone Joint J 2015;97-B:89–93.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 76 - 82
1 Jan 2015
Siebachmeyer M Boddu K Bilal A Hester TW Hardwick T Fox TP Edmonds M Kavarthapu V

We report the outcomes of 20 patients (12 men, 8 women, 21 feet) with Charcot neuro-arthropathy who underwent correction of deformities of the ankle and hindfoot using retrograde intramedullary nail arthrodesis. The mean age of the patients was 62.6 years (46 to 83); their mean BMI was 32.7 (15 to 47) and their median American Society of Anaesthetists score was 3 (2 to 4). All presented with severe deformities and 15 had chronic ulceration. All were treated with reconstructive surgery and seven underwent simultaneous midfoot fusion using a bolt, locking plate or a combination of both. At a mean follow-up of 26 months (8 to 54), limb salvage was achieved in all patients and 12 patients (80%) with ulceration achieved healing and all but one patient regained independent mobilisation. There was failure of fixation with a broken nail requiring revision surgery in one patient. Migration of distal locking screws occurred only when standard screws had been used but not with hydroxyapatite-coated screws. The mean American Academy of Orthopaedic Surgeons Foot and Ankle (AAOS-FAO) score improved from 50.7 (17 to 88) to 65.2 (22 to 88), (p = 0.015). The mean Short Form (SF)-36 Health Survey Physical Component Score improved from 25.2 (16.4 to 42.8) to 29.8 (17.7 to 44.2), (p = 0.003) and the mean Euroqol EQ‑5D‑5L score improved from 0.63 (0.51 to 0.78) to 0.67 (0.57 to 0.84), (p = 0.012).

Single-stage correction of deformity using an intramedullary hindfoot arthrodesis nail is a good form of treatment for patients with severe Charcot hindfoot deformity, ulceration and instability provided a multidisciplinary care plan is delivered.

Cite this article: Bone Joint J 2015;97-B:76–82.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating.

This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK.

Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen.

There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively.

This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.

Cite this article: Bone Joint J 2015;97-B:94–9.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 141 - 144
1 Jan 2015
Hughes AW Clark D Carlino W Gosling O Spencer RF

Reported rates of dislocation in hip hemiarthroplasty (HA) for the treatment of intra-capsular fractures of the hip, range between 1% and 10%. HA is frequently performed through a direct lateral surgical approach. The aim of this study is to determine the contribution of the anterior capsule to the stability of a cemented HA through a direct lateral approach.

A total of five whole-body cadavers were thawed at room temperature, providing ten hip joints for investigation. A Thompson HA was cemented in place via a direct lateral approach. The cadavers were then positioned supine, both knee joints were disarticulated and a digital torque wrench was attached to the femur using a circular frame with three half pins. The wrench applied an external rotation force with the hip in extension to allow the hip to dislocate anteriorly. Each hip was dislocated twice; once with a capsular repair and once without repairing the capsule. Stratified sampling ensured the order in which this was performed was alternated for the paired hips on each cadaver.

Comparing peak torque force in hips with the capsule repaired and peak torque force in hips without repair of the capsule, revealed a significant difference between the ‘capsule repaired’ (mean 22.96 Nm, standard deviation (sd) 4.61) and the ‘capsule not repaired’ group (mean 5.6 Nm, sd 2.81) (p < 0.001). Capsular repair may help reduce the risk of hip dislocation following HA.

Cite this article: Bone Joint J 2015;97-B:141–4.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 1 - 2
1 Jan 2015
Haddad FS McCaskie AW

Trauma and Orthopaedic care has been through a rapid evolution over the past few decades. This Editorial discusses some of the advances.

Cite this article: Bone Joint J 2015;97-B:1–2.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 100 - 103
1 Jan 2015
Rushton PRP Reed MR Pratt RK

The Nottingham Hip Fracture Score (NHFS) was developed to assess the risk of death following a fracture of the hip, based on pre-operative patient characteristics. We performed an independent validation of the NHFS, assessed the degree of geographical variation that exists between different units within the United Kingdom and attempted to define a NHFS level that is associated with high risk of mortality.

The NHFS was calculated retrospectively for consecutive patients presenting with a fracture of the hip to two hospitals in England. The observed 30-day mortality for each NHFS cohort was compared with that predicted by the NHFS using the Hosmer–Lemeshow test. The distribution of NHFS in the observed group was compared with data from other hospitals in the United Kingdom. The proportion of patients identified as high risk and the mortality within the high risk group were assessed for groups defined using different thresholds for the NHFS.

In all 1079 hip fractures were included in the analysis, with a mean age of 83 years (60 to 105), 284 (26%) male. Overall 30-day mortality was 7.3%. The NHFS was a significant predictor of 30-day mortality. Statistically significant differences in the distribution of the NHFS were present between different units in England (p < 0.001). A NHFS ≥ 6 appears to be an appropriate cut-point to identify patients at high risk of mortality following a fracture of the hip.

Cite this article: Bone Joint J 2015;96-B:100–3.


Bone & Joint Research
Vol. 4, Issue 1 | Pages 6 - 10
1 Jan 2015
Goudie ST Deakin AH Deep K

Objectives

Acetabular component orientation in total hip arthroplasty (THA) influences results. Intra-operatively, the natural arthritic acetabulum is often used as a reference to position the acetabular component. Detailed information regarding its orientation is therefore essential. The aim of this study was to identify the acetabular inclination and anteversion in arthritic hips.

Methods

Acetabular inclination and anteversion in 65 symptomatic arthritic hips requiring THA were measured using a computer navigation system. All patients were Caucasian with primary osteoarthritis (29 men, 36 women). The mean age was 68 years (SD 8). Mean inclination was 50.5° (SD 7.8) in men and 52.1° (SD 6.7) in women. Mean anteversion was 8.3° (SD 8.7) in men and 14.4° (SD 11.6) in women.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 64 - 70
1 Jan 2015
Hamilton DF Burnett R Patton JT Howie CR Moran M Simpson AHRW Gaston P

Total knee arthroplasty (TKA) is an established and successful procedure. However, the design of prostheses continues to be modified in an attempt to optimise the functional outcome of the patient.

The aim of this study was to determine if patient outcome after TKA was influenced by the design of the prosthesis used.

A total of 212 patients (mean age 69; 43 to 92; 131 female (62%), 81 male (32%)) were enrolled in a single centre double-blind trial and randomised to receive either a Kinemax (group 1) or a Triathlon (group 2) TKA.

Patients were assessed pre-operatively, at six weeks, six months, one year and three years after surgery. The outcome assessments used were the Oxford Knee Score; range of movement; pain numerical rating scales; lower limb power output; timed functional assessment battery and a satisfaction survey. Data were assessed incorporating change over all assessment time points, using repeated measures analysis of variance longitudinal mixed models. Implant group 2 showed a significantly greater range of movement (p = 0.009), greater lower limb power output (p = 0.026) and reduced report of ‘worst daily pain’ (p = 0.003) over the three years of follow-up. Differences in Oxford Knee Score (p = 0.09), report of ‘average daily pain’ (p = 0.57) and timed functional performance tasks (p = 0.23) did not reach statistical significance. Satisfaction with outcome was significantly better in group 2 (p = 0.001).

These results suggest that patient outcome after TKA can be influenced by the prosthesis used.

Cite this article: Bone Joint J 2015;97-B:64–70.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 45 - 49
1 Jan 2015
Tokarski AT Novack TA Parvizi J

We hypothesised that the use of tantalum (Ta) acetabular components in revision total hip arthroplasty (THA) was protective against subsequent failure due to infection. We identified 966 patients (421 men, 545 women and 990 hips) who had undergone revision THA between 2000 and 2013. The mean follow up was 40.2 months (3 months to 13.1 years). The mean age of the men and women was 62.3 years (31 to 90) and 65.1 years (25 to 92), respectively.

Titanium (Ti) acetabular components were used in 536 hips while Ta components were used in 454 hips. In total, 73 (7.3%) hips experienced subsequent acetabular failure. The incidence of failure was lower in the Ta group at 4.4% (20/454) compared with 9.9% (53/536) in the Ti group (p < 0.001, odds ratio 2.38; 95% CI 1.37 to 4.27). Among the 144 hips (64 Ta, 80 Ti) for which revision had been performed because of infection, failure due to a subsequent infection was lower in the Ta group at 3.1% (2/64) compared with 17.5% (14/80) for the Ti group (p = 0.006).

Thus, the use of Ta acetabular components during revision THA was associated with a lower incidence of failure from all causes and Ta components were associated with a lower incidence of subsequent infection when used in patients with periprosthetic joint infection.

Cite this article: Bone Joint J 2015;97-B:45–9.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 134 - 140
1 Jan 2015
Kang S Kam M Miraj F Park S

A small proportion of children with Gartland type III supracondylar humeral fracture (SCHF) experience troubling limited or delayed recovery after operative treatment. We hypothesised that the fracture level relative to the isthmus of the humerus would affect the outcome.

We retrospectively reviewed 230 children who underwent closed reduction and percutaneous pinning (CRPP) for their Gartland type III SCHFs between March 2003 and December 2012. There were 144 boys and 86 girls, with the mean age of six years (1.1 to 15.2). The clinico-radiological characteristics and surgical outcomes (recovery of the elbow range of movement, post-operative angulation, and the final Flynn grade) were recorded. Multivariate analysis was employed to identify prognostic factors that influenced outcome, including fracture level. Multivariate analysis revealed that a fracture below the humeral isthmus was significantly associated with poor prognosis in terms of the range of elbow movement (p < 0.001), angulation (p = 0.001) and Flynn grade (p = 0.003). Age over ten years was also a poor prognostic factor for recovery of the range of elbow movement (p = 0.027).

This is the first study demonstrating a subclassification system of Gartland III fractures with prognostic significance. This will guide surgeons in peri-operative planning and counselling as well as directing future research aimed at improving outcomes.

Cite this article: Bone Joint J 2015;97-B:134–40.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 50 - 55
1 Jan 2015
Zuiderbaan HA Khamaisy S Thein R Nawabi DH Pearle AD

Progressive degenerative changes in the medial compartment of the knee following lateral unicompartmental arthroplasty (UKA) remains a leading indication for revision surgery. The purpose of this study is to evaluate changes in the congruence and joint space width (JSW) of the medial compartment following lateral UKA. The congruence of the medial compartment of 53 knees (24 men, 23 women, mean age 13.1 years; sd 62.1) following lateral UKA was evaluated pre-operatively and six weeks post-operatively, and compared with 41 normal knees (26 men, 15 women, mean age 33.7 years; sd 6.4), using an Interactive closest point algorithm which calculated the congruence index (CI) by performing a rigid transformation that best aligns the digitised tibial and femoral surfaces. Inner, middle and outer JSWs were measured by sub-dividing the medial compartment into four quarters on pre- and post-operative, weight bearing tunnel view radiographs. The mean CI of knees following lateral UKA significantly improved from 0.92 (sd 0.06) pre-operatively to 0.96 (sd 0.02) (p < 0.001) six weeks post-operatively. The mean CI of the healthy control group was 0.99 sd 0.01. Post-operatively, the mean inner JSW increased (p = 0.006) and the outer decreased (p = 0.002). The JSW was restored post-operatively as no significant differences were noted in all three locations compared with the control group (inner JSW p = 0.43; middle JSW p = 0.019, outer JSW p = 0.51).

Our data suggest that a well conducted lateral UKA may improve the congruence and normalise the JSW of the medial compartment, potentially preventing progression of degenerative change.

Cite this article: Bone Joint J 2015;97-B:50–5.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 10 - 18
1 Jan 2015
Sabah SA Henckel J Cook E Whittaker R Hothi H Pappas Y Blunn G Skinner JA Hart AJ

Arthroplasty registries are important for the surveillance of joint replacements and the evaluation of outcome. Independent validation of registry data ensures high quality. The ability for orthopaedic implant retrieval centres to validate registry data is not known. We analysed data from the National Joint Registry for England, Wales and Northern Ireland (NJR) for primary metal-on-metal hip arthroplasties performed between 2003 and 2013. Records were linked to the London Implant Retrieval Centre (RC) for validation. A total of 67 045 procedures on the NJR and 782 revised pairs of components from the RC were included. We were able to link 476 procedures (60.9%) recorded with the RC to the NJR successfully. However, 306 procedures (39.1%) could not be linked. The outcome recorded by the NJR (as either revised, unrevised or death) for a primary procedure was incorrect in 79 linked cases (16.6%). The rate of registry-retrieval linkage and correct assignment of outcome code improved over time. The rates of error for component reference numbers on the NJR were as follows: femoral head category number 14/229 (5.0%); femoral head batch number 13/232 (5.3%); acetabular component category number 2/293 (0.7%) and acetabular component batch number 24/347 (6.5%).

Registry-retrieval linkage provided a novel means for the validation of data, particularly for component fields. This study suggests that NJR reports may underestimate rates of revision for many types of metal-on-metal hip replacement. This is topical given the increasing scope for NJR data. We recommend a system for continuous independent evaluation of the quality and validity of NJR data.

Cite this article: Bone Joint J 2015;97-B:10–18.


Bone & Joint Research
Vol. 4, Issue 1 | Pages 1 - 5
1 Jan 2015
Vázquez-Portalatín N Breur GJ Panitch A Goergen CJ

Objective

Dunkin Hartley guinea pigs, a commonly used animal model of osteoarthritis, were used to determine if high frequency ultrasound can ensure intra-articular injections are accurately positioned in the knee joint.

Methods

A high-resolution small animal ultrasound system with a 40 MHz transducer was used for image-guided injections. A total of 36 guinea pigs were anaesthetised with isoflurane and placed on a heated stage. Sterile needles were inserted directly into the knee joint medially, while the transducer was placed on the lateral surface, allowing the femur, tibia and fat pad to be visualised in the images. B-mode cine loops were acquired during 100 µl. We assessed our ability to visualise 1) important anatomical landmarks, 2) the needle and 3) anatomical changes due to the injection.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 24 - 28
1 Jan 2015
Malviya A Dandachli W Beech Z Bankes MJ Witt JD

Stress fractures occurring in the pubis and ischium after peri-acetabular osteotomy (PAO) are not well recognised, with a reported incidence of 2% to 3%. The purpose of this study was to analyse the incidence of stress fracture after Bernese PAO under the care of two high-volume surgeons. The study included 359 patients (48 men, 311 women) operated on at a mean age of 31.1 years (15 to 56), with a mean follow-up of 26 months (6 to 64). Complete follow-up radiographs were available for 348 patients, 64 of whom (18.4%) developed a stress fracture of the inferior pubic ramus, which was noted at a mean of 9.1 weeks (5 to 55) after surgery. Most (58; 91%) healed. In 40 of the patients with a stress fracture (62.5%), pubic nonunion also occurred. Those with a stress fracture were significantly older (mean 33.9 years (16 to 50) vs 30.5 years (15 to 56), p = 0.002) and had significantly more mean pre-operative deformity: mean centre–edge angle (9.8° (-9.5 to 35) vs 12.4° (-33 to 28), p = 0.04) and mean Tönnis angle (22.8° (0 to 45) vs 18.7° (-2 to 38), p < 0.001). The pubic nonunion rate was significantly higher in those with a stress fracture (62.5% vs 7%, p < 0.001), with regression analysis revealing that these patients had 11.8 times higher risk than those without nonunion.

Cite this article: Bone Joint J 2015; 97-B:24–8.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 35 - 44
1 Jan 2015
Flivik G Kristiansson I Ryd L

We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (sd 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (sd 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement–bone interface in order to maximise acetabular component stability and longevity.

Cite this article: Bone Joint J 2015;97-B:35–44.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 121 - 128
1 Jan 2015
Kang S Han I Hong SH Cho HS Kim W Kim H

Cancellous allograft bone chips are commonly used in the reconstruction of defects in bone after removal of benign tumours. We investigated the MRI features of grafted bone chips and their change over time, and compared them with those with recurrent tumour. We retrospectively reviewed 66 post-operative MRIs from 34 patients who had undergone curettage and grafting with cancellous bone chips to fill the defect after excision of a tumour. All grafts showed consistent features at least six months after grafting: homogeneous intermediate or low signal intensities with or without scattered hyperintense foci (speckled hyperintensities) on T1 images; high signal intensities with scattered hypointense foci (speckled hypointensities) on T2 images, and peripheral rim enhancement with or without central heterogeneous enhancements on enhanced images. Incorporation of the graft occurred from the periphery to the centre, and was completed within three years. Recurrent lesions consistently showed the same signal intensities as those of pre-operative MRIs of the primary lesions. There were four misdiagnoses, three of which were chondroid tumours.

We identified typical MRI features and clarified the incorporation process of grafted cancellous allograft bone chips. The most important characteristics of recurrent tumours were that they showed the same signal intensities as the primary tumours. It might sometimes be difficult to differentiate grafted cancellous allograft bone chips from a recurrent chondroid tumour.

Cite this article: Bone Joint J 2015;97-B:121–8.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 109 - 114
1 Jan 2015
Haller JM Holt DC McFadden ML Higgins TF Kubiak EN

The aim of this study was to report the incidence of arthrofibrosis of the knee and identify risk factors for its development following a fracture of the tibial plateau. We carried out a retrospective review of 186 patients (114 male, 72 female) with a fracture of the tibial plateau who underwent open reduction and internal fixation. Their mean age was 46.4 years (19 to 83) and the mean follow-up was16.0 months (6 to 80).

A total of 27 patients (14.5%) developed arthrofibrosis requiring a further intervention. Using multivariate regression analysis, the use of a provisional external fixator (odds ratio (OR) 4.63, 95% confidence interval (CI) 1.26 to 17.7, p = 0.021) was significantly associated with the development of arthrofibrosis. Similarly, the use of a continuous passive movement (CPM) machine was associated with significantly less development of arthrofibrosis (OR = 0.32, 95% CI 0.11 to 0.83, p = 0.024). The effect of time in an external fixator was found to be significant, with each extra day of external fixation increasing the odds of requiring manipulation under anaesthesia (MUA) or quadricepsplasty by 10% (OR = 1.10, p = 0.030). High-energy fracture, surgical approach, infection and use of tobacco were not associated with the development of arthrofibrosis. Patients with a successful MUA had significantly less time to MUA (mean 2.9 months; sd 1.25) than those with an unsuccessful MUA (mean 4.86 months; sd 2.61, p = 0.014). For those with limited movement, therefore, performing an MUA within three months of the injury may result in a better range of movement.

Based our results, CPM following operative fixation for a fracture of the tibial plateau may reduce the risk of the development of arthrofibrosis, particularly in patients who also undergo prolonged provisional external fixation.

Cite this article: Bone Joint J 2015;97-B:109–14.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 115 - 120
1 Jan 2015
Reddy KIA Wafa H Gaston CL Grimer RJ Abudu AT Jeys LM Carter SR Tillman RM

A poor response to chemotherapy (≤ 90% necrosis) for osteosarcomas leads to poorer survival and an increased risk of local recurrence, particularly if there is a close margin of excision. We evaluated whether amputation confers any survival benefit over limb salvage surgery (LSS) with narrow margins in patients who respond poorly to chemotherapy.

We only analysed patients with an osteosarcoma of the limb, a poor response to chemotherapy and close margins on LSS (marginal/intralesional) or primary amputation: 360 patients (36 LSS (intralesional margins), 197 LSS (marginal margins) and 127 amputations) were included. Local recurrence developed in 13 (36%) following LSS with intralesional margins, and 39 (20%) following LSS with marginal margins. There was no local recurrence in patients who underwent amputation. The five-year survival for all patients was 41% (95% confidence interval (CI) 35 to 46), but for those treated by LSS with marginal margins was 46.2% (95% CI 38 to 53), 36.3% (95% CI 27 to 45) for those treated by amputation, and 28% (95 CI 14 to 44) for those treated by LSS with intralesional margins. Patients who had LSS and then developed local recurrence as a first event had the same survival as those who had primary amputation without local recurrence. Prophylactic adjuvant radiotherapy was used in 40 patients but had no discernible effect in preventing local recurrence.

Although amputation offered better local control, it conferred no clear survival benefit over LSS with marginal margins in these patients with a poor overall prognosis.

Cite this article: Bone Joint J 2015;97-B:115–20.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 19 - 23
1 Jan 2015
den Hartog YM Mathijssen NMC Hannink G Vehmeijer SBW

After implementation of a ‘fast-track’ rehabilitation protocol in our hospital, mean length of hospital stay for primary total hip arthroplasty decreased from 4.6 to 2.9 nights for unselected patients. However, despite this reduction there was still a wide range across the patients’ hospital duration. The purpose of this study was to identify which specific patient characteristics influence length of stay after successful implementation of a ‘fast-track’ rehabilitation protocol. A total of 477 patients (317 female and 160 male, mean age 71.0 years; 39.3 to 92.6, mean BMI 27.0 kg/m2;18.8 to 45.2) who underwent primary total hip arthroplasty between 1 February 2011 and 31 January 2013, were included in this retrospective cohort study. A length of stay greater than the median was considered as an increased duration. Logistic regression analyses were performed to identify potential factors associated with increased durations. Median length of stay was two nights (interquartile range 1), and the mean length of stay 2.9 nights (1 to 75). In all, 266 patients had a length of stay ≤ two nights. Age (odds ratio (OR) 2.46; 95% confidence intervals (CI) 1.72 to 3.51; p <  0.001), living situation (alone vs living together with cohabitants, OR 2.09; 95% CI 1.33 to 3.30; p = 0.002) and approach (anterior approach vs lateral, OR 0.29; 95% CI 0.19 to 0.46; p <  0.001) (posterolateral approach vs lateral, OR 0.24; 95% CI 0.10 to 0.55; p < 0.001) were factors that were significantly associated with increased length of stay in the multivariable logistic regression model.

Cite this article: Bone Joint J 2015;97-B:19–23.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 83 - 88
1 Jan 2015
Kocsis G McCulloch TA Thyagarajan D Wallace WA

The LockDown device (previously called Surgilig) is a braided polyester mesh which is mostly used to reconstruct the dislocated acromioclavicular joint. More than 11 000 have been implanted worldwide. Little is known about the tissue reaction to the device nor to its wear products when implanted in an extra-articular site in humans. This is of importance as an adverse immunological reaction could result in osteolysis or damage to the local tissues, thereby affecting the longevity of the implant.

We analysed the histology of five LockDown implants retrieved from five patients over the last seven years by one of the senior authors. Routine analysis was carried out in all five cases and immunohistochemistry in one.

The LockDown device acts as a scaffold for connective tissue which forms an investing fibrous pseudoligament. The immunological response at the histological level seems favourable with a limited histiocytic and giant cell response to micron-sized wear particles. The connective tissue envelope around the implant is less organised than a native ligament.

Cite this article: Bone Joint J 2015;97-B:83–8.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 56 - 63
1 Jan 2015
Abane L Anract P Boisgard S Descamps S Courpied JP Hamadouche M

In this study we randomised 140 patients who were due to undergo primary total knee arthroplasty (TKA) to have the procedure performed using either patient-specific cutting guides (PSCG) or conventional instrumentation (CI).

The primary outcome measure was the mechanical axis, as measured at three months on a standing long-leg radiograph by the hip–knee–ankle (HKA) angle. This was undertaken by an independent observer who was blinded to the instrumentation. Secondary outcome measures were component positioning, operating time, Knee Society and Oxford knee scores, blood loss and length of hospital stay.

A total of 126 patients (67 in the CI group and 59 in the PSCG group) had complete clinical and radiological data. There were 88 females and 52 males with a mean age of 69.3 years (47 to 84) and a mean BMI of 28.6 kg/m2 (20.2 to 40.8). The mean HKA angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4 to 183.4) in the PSCG group (p = 0.34). Outliers were identified in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%) in the PSCG group (p = 0.99). There was no significant difference in the clinical results (p = 0.95 and 0.59, respectively). Operating time, blood loss and length of hospital stay were not significantly reduced (p = 0.09, 0.58 and 0.50, respectively) when using PSCG.

The use of PSCG in primary TKA did not reduce the proportion of outliers as measured by post-operative coronal alignment.

Cite this article: Bone Joint J 2015;97-B:56–63.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 71 - 75
1 Jan 2015
Hoell S Borgers L Gosheger G Dieckmann R Schulz D Gerss J Hardes J

The purpose of this study was to evaluate whether the serum level of interleukin 6 (IL-6) could be used to identify the persistence of infection after the first stage of a two-stage revision for periprosthetic joint infection.

Between 2010 and 2011, we prospectively studied 55 patients (23 men, 32 women; mean age 69.5 years; 36 to 86) with a periprosthetic joint infection. Bacteria were identified in two intra-operative tissue samples during re-implantation in 16 patients. These cases were classified as representing persistent infection.

To calculate a precise cut-off value which could be used in everyday clinical practice, a 3 x 2 contingency table was constructed and manually defined.

We found that a serum IL-6 ≥ 13 pg/mL can be regarded as indicating infection: its positive-predictive value is 90.9%. A serum IL-6 ≤ 8 pg/mL can be regarded as indicating an absence of infection: its negative predictive value is 92.1%.

The serum IL-6 level seems to be a reasonable marker for identifying persistent infection after the first stage of a revision joint arthroplasty and before attempting re-implantation.

Cite this article: Bone Joint J 2015;97-B:71–5.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 29 - 34
1 Jan 2015
Novais EN Potter GD Clohisy JC Millis MB Kim YJ Trousdale RT Carry PM Sierra RJ

Obesity is a risk factor for complications following many orthopaedic procedures. The purpose of this study was to investigate whether obesity was an independent risk factor increasing the rate of complications following periacetabular osteotomy (PAO) and to determine whether radiographic correction after PAO was affected by obesity.

We retrospectively collected demographic, clinical and radiographic data on 280 patients (231 women; 82.5% and 49 men; 17.5%) who were followed for a mean of 48 months (12 to 60) after PAO. A total of 65 patients (23.2%) were obese (body mass index (BMI) > 30 kg/m2). Univariate and multivariate analysis demonstrated that BMI was an independent risk factor associated with the severity of the complications. The average probability of a patient developing a major complication was 22% (95% confidence interval (CI) 11.78 to 38.21) for an obese patient compared with 3% (95% CI 1.39 to 6.58) for a non-obese patient The odds of a patient developing a major complication were 11 times higher (95% CI 4.71 to 17.60, p <  0.0001) for an obese compared with a non-obese patient.

Following PAO surgery, there was no difference in radiographic correction between obese and non-obese patients. PAO procedures in obese patients correct the deformity effectively but are associated with an increased rate of complications.

Cite this article: Bone Joint J 2015;97-B:29–34.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 3 - 9
1 Jan 2015
Hossain FS Konan S Patel S Rodriguez-Merchan EC Haddad FS

The routine use of patient reported outcome measures (PROMs) in evaluating the outcome after arthroplasty by healthcare organisations reflects a growing recognition of the importance of patients’ perspectives in improving treatment. Although widely embraced in the NHS, there are concerns that PROMs are being used beyond their means due to a poor understanding of their limitations.

This paper reviews some of the current challenges in using PROMs to evaluate total knee arthroplasty. It highlights alternative methods that have been used to improve the assessment of outcome.

Cite this article: Bone Joint J 2015;97-B:3–9.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 129 - 133
1 Jan 2015
Niedzielski KR Malecki K Flont P Fabis J

In 11 paediatric patients (seven girls and four boys, from 12 to 15 years old) with unilateral obligatory patellar dislocation and ligamentous laxity vastus medialis advancement, lateral release, partial patellar ligament transposition and Galeazzi semitendinosus tenodesis was undertaken to stabilise the patella. The diagnostic criterion for ligamentous laxity was based on the Beighton scale. Outcomes were evaluated radiologically and functionally by measurement of the range of knee movement and isokinetic testing. The evaluation also included the Lysholm knee scale. Follow-up studies took place at a mean of 8.1 years (5 to 15) post-operatively.

Normal patellar tracking without any recurrence of dislocation was obtained in ten out of 11 patients. Pain related to vigorous activity was reported by nine patients. Compared with the opposite normal side, the isokinetic tests revealed a statistically significant decrease in the maximal torque values for the affected quadriceps muscle (p = 0.003 and p = 0.004), but no difference between the knee flexors (for angular velocities of 60°/s and 180°/s) (p = 0.858 and p = 0.79).

The applied surgical technique generally prevents the recurrence of the disorder in children with habitual patellar dislocation and ligamentous laxity. Quadriceps muscle weakness can be expected to occur post-operatively,

Cite this article: Bone Joint J 2015;96-B:129–33.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1657 - 1662
1 Dec 2014
Stambough JB Clohisy JC Barrack RL Nunley RM Keeney JA

The aims of this retrospective study were to compare the mid-term outcomes following revision total knee replacement (TKR) in 76 patients (81 knees) < 55 years of age with those of a matched group of primary TKRs based on age, BMI, gender and comorbid conditions. We report the activity levels, functional scores, rates of revision and complications. Compared with patients undergoing primary TKR, those undergoing revision TKR had less improvement in the mean Knee Society function scores (8.14 (–55 to +60) vs 23.3 points (–40 to +80), p < 0.001), a similar improvement in UCLA activity level (p = 0.52), and similar minor complication rates (16% vs 13%, p = 0.83) at a mean follow-up of 4.6 years (2 to 13.4). Further revision surgery was more common among revised TKRs (17% vs 5%, p = 0.02), with deep infection and instability being the most common reasons for failure. As many as one-third of patients aged < 55 years in the revision group had a complication or failure requiring further surgery.

Young patients undergoing revision TKR should be counselled that they can expect somewhat less improvement and a higher risk of complications than occur after primary TKR.

Cite this article: Bone Joint J 2014; 96-B:1657–62


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1706 - 1712
1 Dec 2014
Bus MPA Boerhout EJ Bramer JAM Dijkstra PDS

Peri-acetabular tumour resections and their subsequent reconstruction are among the most challenging procedures in orthopaedic oncology. Despite the fact that a number of different pelvic endoprostheses have been introduced, rates of complication remain high and long-term results are mostly lacking.

In this retrospective study, we aimed to evaluate the outcome of reconstructing a peri-acetabular defect with a pedestal cup endoprosthesis after a type 2 or type 2/3 internal hemipelvectomy.

A total of 19 patients (11M:8F) with a mean age of 48 years (14 to 72) were included, most of whom had been treated for a primary bone tumour (n = 16) between 2003 and 2009. After a mean follow-up of 39 months (28 days to 8.7 years) seven patients had died. After a mean follow-up of 7.9 years (4.3 to 10.5), 12 patients were alive, of whom 11 were disease-free. Complications occurred in 15 patients. Three had recurrent dislocations and three experienced aseptic loosening. There were no mechanical failures. Infection occurred in nine patients, six of whom required removal of the prosthesis. Two patients underwent hindquarter amputation for local recurrence.

The implant survival rate at five years was 50% for all reasons, and 61% for non-oncological reasons. The mean Musculoskeletal Tumor Society score at final follow-up was 49% (13 to 87).

Based on these poor results, we advise caution if using the pedestal cup for reconstruction of a peri-acetabular tumour resection.

Cite this article: Bone Joint J 2014;96-B:1706–12.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1623 - 1630
1 Dec 2014
Monk AP Choji K O’Connor JJ Goodfellow† JW Murray DW

We scanned 25 left knees in healthy human subjects using MRI. Multiplanar reconstruction software was used to take measurements of the inferior and posterior facets of the femoral condyles and the trochlea.

A ‘basic circle’ can be defined which, in the sagittal plane, fits the posterior and inferior facets of the lateral condyle, the posterior facet of the medial condyle and the floor of the groove of the trochlea. It also approximately fits both condyles in the coronal plane (inferior facets) and the axial plane (posterior facets). The circle fitting the inferior facet of the medial condyle in the sagittal plane was consistently 35% larger than the other circles and was termed the ‘medial inferior circle’. There were strong correlations between the radii of the circles, the relative positions of the centres of the condyles, the width of the condyles, the total knee width and skeletal measurements including height. There was poor correlation between the radii of the circles and the position of the trochlea relative to the condyles.

In summary, the condyles are approximately spherical except for the inferior facet medially, which has a larger radius in the sagittal plane. The size and position of the condyles are consistent and change with the size of the person. However, the position of the trochlea is variable even though its radius is similar to that of the condyles. This information has implications for understanding anterior knee pain and for the design of knee replacements.

Cite this article: Bone Joint J 2014;96-B:1623–30.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1586 - 1593
1 Dec 2014
Li H Wang Y Oni JK Qu X Li T Zeng Y Liu F Zhu Z

There have been several studies examining the association between the morphological characteristics seen in acetabular dysplasia and the incidence of the osteoarthritis (OA).

However, most studies focus mainly on acetabular morphological analysis, and few studies have scrutinised the effect of femoral morphology. In this study we enrolled 36 patients with bilateral acetabular dysplasia and early or mid-stage OA in one hip and no OA in the contralateral hip. CT scans were performed from the iliac crest to 2 cm inferior to the tibial tuberosity, and the morphological characteristics of both acetabulum and femur were studied.

In addition, 200 hips in 100 healthy volunteer Chinese adults formed a control group. The results showed that the dysplastic group with OA had a significantly larger femoral neck anteversion and a significantly shorter abductor lever arm than both the dysplastic group without OA and the controls. Femoral neck anteversion had a significant negative correlation with the length of the abductor lever arm and we conclude that it may contribute to the development of OA in dysplastic hips.

Cite this article: Bone Joint J 2014; 96-B:1586–93.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 1 - 1
1 Dec 2014
Ollivere B


Bone & Joint 360
Vol. 3, Issue 6 | Pages 37 - 39
1 Dec 2014
Foy MA


Bone & Joint 360
Vol. 3, Issue 6 | Pages 12 - 16
1 Dec 2014

The December 2014 Knee Roundup360 looks at: national guidance on arthroplasty thromboprophylaxis is effective; unicompartmental knee replacement has the edge in terms of short-term complications; stiff knees, timing and manipulation; neuropathic pain and total knee replacement; synovial fluid α-defensin and CRP: a new gold standard in joint infection diagnosis?; how to assess anterior knee pain?; where is the evidence? Five new implants under the spotlight; and a fresh look at ACL reconstruction


Bone & Joint Research
Vol. 3, Issue 12 | Pages 328 - 334
1 Dec 2014
Harada Y Kokubu T Mifune Y Inui A Sakata R Muto T Takase F Kurosaka M

Objectives

To investigate the appropriate dose and interval for the administration of triamcinolone acetonide (TA) in treating tendinopathy to avoid adverse effects such as tendon degeneration and rupture.

Methods

Human rotator cuff-derived cells were cultured using three media: regular medium (control), regular medium with 0.1 mg/mL of TA (low TA group), and with 1.0 mg/mL of TA (high TA group). The cell morphology, apoptosis, and viability were assessed at designated time points.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1693 - 1698
1 Dec 2014
Kato S Murakami H Demura S Yoshioka K Kawahara N Tomita K Tsuchiya H

Total en bloc spondylectomy (TES) is the total resection of a vertebra containing a tumour. Many authors have investigated patient-reported outcomes after routine spinal surgery and surgery for tumours in general. However, this is the first report of patient-reported outcomes, including health-related quality of life (HRQoL) and satisfaction, after en bloc vertebral resection for a spinal tumour.

Of the 54 patients who underwent TES for a primary tumour between 1993 and 2010, 19 died and four were lost to follow-up. In January 2012, a questionnaire was sent to the 31 surviving patients. This included the short form-36 to assess HRQoL and questions about the current condition of their disease, activities of daily living (ADL) and surgery. The response rate was high at 83.9% (26/31 patients). We found that most patients were satisfied and maintained good performance of their ADLs.

The mental health status and social roles of the HRQoL scores were nearly equivalent to those of healthy individuals, regardless of the time since surgery. There was significant impairment of physical health in the early post-operative years, but this usually returned to normal approximately three years after surgery.

Cite this article: Bone Joint J 2014;96-B:1693–8.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1713 - 1713
1 Dec 2014
Jones D Hill R


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1715 - 1716
1 Dec 2014
Khanduja V

The FRCS (Tr & Orth) examination has three components: MCQs, Vivas and Clinical Examination. The Vivas are further divided into four sections comprising Basic Science, Adult Pathology, Hands and Children’s Orthopaedics and Trauma. The Clinical Examination section is divided into Upper and Lower limb cases. The aim of this section in the Journal is to focus specifically on the trainees preparing for the exam and to cater to all the sections of the exam. The vision is to complete the cycle of all relevant exam topics (as per the syllabus) in four years.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 19 - 21
1 Dec 2014

The December 2014 Shoulder & Elbow Roundup360 looks at: cuff tears and plexus injury;

corticosteroids and physiotherapy in SAI; diabetes and elbow arthroplasty; distal biceps tendon repairs; shockwave therapy in frozen shoulder; hydrodilation and steroids for adhesive capsulitis; just what do our patients read?; and what happens to that stable radial head fracture?


Bone & Joint 360
Vol. 3, Issue 6 | Pages 10 - 12
1 Dec 2014

The December 2014 Hip & Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection


Bone & Joint 360
Vol. 3, Issue 6 | Pages 29 - 31
1 Dec 2014

The December 2014 Children’s orthopaedics Roundup360 looks at: predicting drift in supracondylar fractures; do normal hips dislocate?; the burden of trampoline fractures; muscle eversion activity is strongly predictive of outcome in CTEV; the modified Dunn osteotomy; plaster and moulded casts; and psychology and fractures.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 39 - 40
1 Dec 2014
Foy MA


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1714 - 1714
1 Dec 2014
Haddad FS

Amin A, Watson A, Mangwani J, Nawabi DH, Ahluwalia R, Loeffler M. A prospective randomised controlled trial of autologous retransfusion in total knee replacement. Bone Joint J 2008;90-B:451–454.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1594 - 1599
1 Dec 2014
Hwang KT Kim YH Kim YS Ryu JA

We investigated the incidence of soft-tissue lesions after small head metal-on-metal total hip replacement (MoM THR). Between December 1993 and May 1999, 149 patients (195 hips) underwent primary cementless MoM THR.

During the follow-up period, three patients (five THRs) died and eight patients (14 THRs) were lost to follow-up. We requested that all patients undergo CT evaluation. After exclusion of five patients (six THRs) who had undergone a revision procedure, and 22 (28 THRs) who were unwilling to take part in this study, 111 patients (142 THRs) were evaluated. There were 63 men (88 THRs) and 48 women (54 THRs) with a mean age of 45.7 years (37 to 56) at the time of surgery. The mean follow-up was 15.4 years (13 to 19). A soft-tissue lesion was defined as an abnormal peri-prosthetic collection of fluid, solid lesion or asymmetrical soft-tissue mass.

At final follow-up, soft-tissue lesions were found in relation to 28 THRs (19.7%), including 25 solid and three cystic lesions. They were found in 20 men and eight women; 26 lesions were asymptomatic and two were symptomatic. The mean maximal diameter of the soft-tissue lesion was 42.3 mm (17 to 135). The relatively high rate of soft-tissue lesions observed with small head MoM THR remains a concern.

Cite this article: Bone Joint J 2014;96-B:1594–9.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1669 - 1673
1 Dec 2014
Van der Merwe JM Haddad FS Duncan CP

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella.

We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction (‘experts’) and ten residents of orthopaedic surgery in the last two years of training (‘pre-experts’). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order.

The reliability was assessed using the Kappa and weighted Kappa values.

The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively.

The UCS has substantial inter-observer reliability and ‘near perfect’ intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users.

Cite this article: Bone Joint J 2014;96-B:1669–73.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1681 - 1687
1 Dec 2014
Foruria AM Lawrence TM Augustin S Morrey BF Sanchez-Sotelo J

We retrospectively reviewed 89 consecutive patients (45 men and 44 women) with a mean age at the time of injury of 58 years (18 to 97) who had undergone external fixation after sustaining a unilateral fracture of the distal humerus. Our objectives were to determine the incidence of heterotopic ossification (HO); identify risk factors associated with the development of HO; and characterise the location, severity and resultant functional impairment attributable to the presence of HO.

HO was identified in 37 elbows (42%), mostly around the humerus and along the course of the medial collateral ligament. HO was hazy immature in five elbows (13.5%), mature discrete in 20 (54%), extensive mature in 10 (27%), and complete bone bridges were present in two elbows (5.5%). Mild functional impairment occurred in eight patients, moderate in 27 and severe in two. HO was associated with less extension (p = 0.032) and less overall flexion-to-extension movement (p = 0.022); the flexion-to-extension arc was < 100º in 21 elbows (57%) with HO compared with 18 elbows (35%) without HO (p = 0.03). HO was removed surgically in seven elbows.

The development of HO was significantly associated with sustaining a head injury (p = 0.015), delayed internal fixation (p = 0.027), the method of fracture fixation (p = 0.039) and the use of bone graft or substitute (p = 0.02).HO continues to be a substantial complication after internal fixation for distal humerus fractures.

Cite this article: Bone Joint J 2014;96-B:1681–7.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 21 - 23
1 Dec 2014

The December 2014 Spine Roundup360 looks at: surgeon outcomes;

complications and scoliosis surgery; is sequestrectomy enough in lumbar disc prolapse?; predicting outcomes in lumbar disc herniation; sympathectomy has a direct effect on the dorsal root ganglion; and distal extensions of fusion in adolescent idiopathic scoliosis.