Advertisement for orthosearch.org.uk
Results 901 - 920 of 2422
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1023 - 1028
1 Nov 1999
Williams PR Jones DA Bishay M

Between January 1987 and December 1988 there were 7575 births in the Swansea maternity unit. Of these 823 (10.9%) were considered to be at ‘high risk’ for developmental dysplasia of the hip (DDH). Static ultrasound examination was performed in each case and the results classified on the basis of the method of Graf. A total of 117 type III–IV hips in 83 infants was splinted using the Aberdeen splint. Radiographs of these hips were taken at six and 12 months. Hilgenreiner’s measurements of the acetabular angle were made in all cases and the development of the femoral capital epiphysis was assessed by measuring the epiphyseal area. The effect of splintage on the acetabular angle and the epiphyseal area between the normal and abnormal splinted hips was compared. Radiographs of 16 normal infants (32 normal unsplinted hips) were used as a control group. This cohort has now been followed up for a minimum of nine years. There have been no complications as a result of splintage. The failure rate was 1.7% or 0.25 per 1000 live births. No statistical difference was found when comparing the effect of splintage on the acetabular angle and epiphyseal area between normal and abnormal splinted hips and normal unsplinted hips. Our study has shown that while the Aberdeen splint had a definite but small failure rate, it was safe in that it did not produce avascular necrosis. The current conventional view that a low rate of splintage is always best is therefore brought into question if the Aberdeen splint is chosen for the management of neonatal DDH


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 4 | Pages 669 - 688
1 Nov 1960
Wilkinson J Carter C

1. The histories of 149 patients, coming to the Hospital for Sick Children within the first three years of life with congenital dislocation of the hip (191 dislocated hips), and treated by conservative methods, have been reviewed. 2. The patients with unilateral dislocations (107) have been divided into three groups, according to the angle of slope of the opposite acetabulum. This angle was measured on the first radiograph and related to the mean value for age and sex. 3. The opposite hip was classed as "normal" if the acetabular angle was below or within one standard deviation above the mean for sex and age; as "moderately shallow" if it was between one and two standard deviations above the mean; and as "shallow" if it was over two standard deviations above the mean. This grouping was found to have a direct bearing on the results of conservative treatment in unilateral cases. a) Those with "normal" opposite acetabula–accounting for most of the unilateral cases–responded well. b) Those with "moderately shallow" opposite acetabula responded variably. c) The group with "shallow" opposite acetabula usually failed to respond. 4. Most bilateral dislocations behaved as unilateral dislocations with shallow opposite hips. 5. Additional factors influencing the response to conservative treatment–sex, age at first attendance, family history, fragmentation of the femoral epiphysis and eccentric reduction–are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 726 - 730
1 Jul 2001
Kamegaya M Shinohara Y Kuniyoshi K Moriya H

We studied in vivo the talonavicular alignment of club foot in infants using MRI. We examined 26 patients (36 feet) with congenital club foot. The mean age at examination was 9.0 months (4 to 12). All analyses used MRI of the earliest cartilaginous development of the tarsal bones in the transverse plane, rather than the ossific nucleus. The difference in the mean talar neck angle (44.0 ± 8.1°) in club foot was statistically significant (p < 0.001) when compared with that of the normal foot (30.8 ± 5.5°). The difference between the mean angles in the group treated by operation (47.9 ± 6.7°) and those treated conservatively (40.1 ± 7.5°) was also statistically significant. The anatomical relationship between the head of the talus and the navicular was divided into two patterns, based on the position of the mid-point of the navicular related to the long axis of the head. In the operative group, 18 feet were classified as having a medial shift of the navicular and none had a lateral shift. In the conservative group, 12 showed a medial shift of the navicular and six a lateral shift. All nine unaffected normal feet in which satisfactory MRI measurements were made showed a lateral shift of the navicular. Club feet had a larger talar neck angle and a more medially deviated navicular when compared with normal feet. This was more marked in the surgical group than in the conservative group


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1247 - 1252
1 Sep 2011
Sinha A Edwin J Sreeharsha B Bhalaik V Brownson P

This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively. An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1388 - 1393
1 Oct 2009
Aird JJ Hogg A Rollinson P

In 1937 Blount described a series of 28 patients with ‘Tibia vara’. Since then, a number of deformities in the tibia and the femur have been described in association with this condition. We analysed 14 children with Blount’s disease who were entered into a cross-sectional study. Their mean age was 10 (2 to 18). They underwent a clinical assessment of the rotational profile of their legs and a CT assessment of the angle of anteversion of their hips (femoral version). We compared our results to previously published controls. A statistically significant increase in femoral anteversion was noted in the affected legs, with on average the femurs in patients with Blount’s disease being 26° more anteverted than those in previously published controls. We believe this to be a previously unrecognised component of Blount’s disease, and that the marked intoeing seen in the disease may be partly caused by internal femoral version, in addition to the well-recognised internal tibial version


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1348 - 1355
1 Nov 2019
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar M Turgeon T

Aims

A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA).

Patients and Methods

Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1203 - 1208
1 Sep 2010
Brunner A Hamers AT Fitze M Herzog RF

The β-angle is a radiological tool for measuring the distance between the pathological head-neck junction and the acetabular rim with the hip in 90° of flexion in patients with femoroacetabular impingement. Initially it was measured using an open-chamber MRI. We have developed a technique to measure this angle on plain radiographs. Correlation analysis was undertaken to determine the relationship between the range of movement and the β-angle in 50 patients with femoroacetabular impingement and 50 asymptomatic control subjects. Inter- and intra-observer reliability of the β-angle was also evaluated. Patients with femoroacetabular impingement had a significantly smaller (p < 0.001) mean β-angle (15.6°, 95% confidence interval (CI) 13.3 to 17.7) compared with the asymptomatic group (38.7°, 95% CI 36.5 to 41.0). Correlation between internal rotation and the β-angle was high in the impingement group and moderate in the asymptomatic group. The β-angle had excellent inter- and intra-observer reliability in both groups. Our findings suggest that the measurement of the β-angle on plain radiography may represent a valid, reproducible and cost-effective alternative to open MRI in the assessment of the pathological bony anatomy in patients with cam, pincer and mixed femoroacetabular impingement


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 907 - 913
1 Jul 2011
Ward TR Burns AW Gillespie MJ Scarvell JM Smith PN

Bicruciate-stabilised total knee replacement (TKR) aims to restore normal kinematics by replicating the function of both cruciate ligaments. We performed a prospective, randomised controlled trial in which bicruciate- and posterior-stabilised TKRs were implanted in 13 and 15 osteo-arthritic knees, respectively. The mean age of the bicruciate-stabilised group was 63.9 years (. sd. 10.00) and that of the posterior-stabilised group 63.2 years (. sd. 6.7). A control group comprised 14 normal subjects with a mean age of 67.9 years (. sd. 7.9). The patellar tendon angle (PTA) was measured one week pre-operatively and at seven weeks post-operatively during knee extension, flexion and step-up exercises. At near full extension during step-up, the bicruciate-stabilised TKR produced a higher mean PTA than the posterior-stabilised TKR, indicating that the bicruciate design at least partially restored the kinematic role of the anterior cruciate ligament. The bicruciate-stabilised TKR largely restored the pre-operative kinematics, whereas the posterior-stabilised TKR resulted in a consistently lower PTA at all activities. The PTA in the pre-operative knees was higher than in the control group during the step-up and at near full knee extension. Overall, both groups generated a more normal PTA than that seen in previous studies in high knee flexion. This suggested that both designs of TKR were more effective at replicating the kinematic role of the posterior cruciate ligament than those used in previous studies


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 954 - 962
1 Sep 2001
Rajasekaran S

The progression of post-tubercular kyphosis in 61 children who received ambulatory chemotherapy was studied prospectively. The angles of deformity and kyphosis were measured for each patient at diagnosis, 3, 6, 9, 12 and 18 months later and every year thereafter for 15 years. During the course of the disease signs of instability appeared on the radiographs of some of the children. These were dislocation of the facets, posterior retropulsion of the diseased fragments, lateral translation of the vertebrae in the anteroposterior view and toppling of the superior vertebra. Each sign was allocated one point to create a spinal instability score. The influence on the progression of the deformity of the level of the lesion, the vertebral body loss, the number of segments involved, the angle of deformity before treatment and the spinal instability score was analysed. The mean angle of deformity at the start of treatment was 35°. This increased to 41° at 15 years. Progression occurred during the active phase of the disease and again after cure when variations in progression were observed. Type-I progression showed an increase in deformity until growth had ceased. This could occur either continuously (type Ia) or after a lag period of three to five years (type Ib). Type-II progression showed decrease in deformity with growth. This could occur immediately after the active phase (type IIa) or after a lag period of three to five years (type IIb). Type-III progression showed minimal change during either the active or healed phases and was seen only in those with limited disease. Multiple regression analysis showed that a spinal instability score of more than 2 was a reliable predictor of patients with an increase of more than 30° in deformity and a final deformity of over 60°. Since signs of radiological instability appear early in the disease, they can be reliably used to identify children whose spine is at risk for late progressive collapse. Surgery is advised in these cases


Bone & Joint 360
Vol. 8, Issue 4 | Pages 39 - 42
1 Aug 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 612 - 615
1 May 2009
Knupp M Schuh R Stufkens SAS Bolliger L Hintermann B

We describe a retrospective review of the clinical and radiological parameters of 32 feet in 30 patients (10 men and 20 women) who underwent correction for malalignment of the hindfoot with a modified double arthrodesis through a medial approach. The mean follow-up was 21 months (13 to 37). Fusion was achieved in all feet at a mean of 13 weeks (6 to 30). Apart from the calcaneal pitch angle, all angular measurements improved significantly after surgery. Primary wound healing occurred without complications. The isolated medial approach to the subtalar and talonavicular joints allows good visualisation which facilitated the reduction and positioning of the joints. It was also associated with fewer problems with wound healing than the standard lateral approach


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 817 - 823
1 Jul 2019
Vigdorchik J Eftekhary N Elbuluk A Abdel MP Buckland AJ Schwarzkopf RS Jerabek SA Mayman DJ

Aims

While previously underappreciated, factors related to the spine contribute substantially to the risk of dislocation following total hip arthroplasty (THA). These factors must be taken into consideration during preoperative planning for revision THA due to recurrent instability. We developed a protocol to assess the functional position of the spine, the significance of these findings, and how to address different pathologies at the time of revision THA.

Patients and Methods

Prospectively collected data on 111 patients undergoing revision THA for recurrent instability from January 2014 to January 2017 at two institutions were included (protocol group) and matched 1:1 to 111 revisions specifically performed for instability not using this protocol (control group). Mean follow-up was 2.8 years. Protocol patients underwent standardized preoperative imaging including supine and standing anteroposterior (AP) pelvis and lateral radiographs. Each case was scored according to the Hip-Spine Classification in Revision THA.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 37 - 40
1 Jun 2019


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 5 - 10
1 Jan 2020
Cawley DT Rajamani V Cawley M Selvadurai S Gibson A Molloy S

Aims

Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery.

Methods

A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 489 - 494
1 Oct 2019
Klasan A Bäumlein M Dworschak P Bliemel C Neri T Schofer MD Heyse TJ

Objectives

Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies. The purpose of this study was a direct load-to-failure comparison of a double-wedged cementless stem and a short cementless stem in a cadaveric fracture model.

Methods

Eight hips from four human cadaveric specimens (age mean 76 years (60 to 89)) and eight fourth-generation composite femurs were used. None of the cadaveric specimens had compromised quality (mean T value 0.4 (-1.0 to 5.7)). Each specimen from a pair randomly received either a double-wedged stem or a short stem. A materials testing machine was used for lateral load-to-failure test of up to a maximal load of 5000 N.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 695 - 701
1 Jun 2019
Yang H Wang S Lee K

Aims

The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon.

Patients and Methods

We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1160 - 1167
1 Sep 2019
Wang WT Li YQ Guo YM Li M Mei HB Shao JF Xiong Z Li J Canavese F Chen SY

Aims

The aim of this study was to clarify the factors that predict the development of avascular necrosis (AVN) of the femoral head in children with a fracture of the femoral neck.

Patients and Methods

We retrospectively reviewed 239 children with a mean age of 10.0 years (sd 3.9) who underwent surgical treatment for a femoral neck fracture. Risk factors were recorded, including age, sex, laterality, mechanism of injury, initial displacement, the type of fracture, the time to reduction, and the method and quality of reduction. AVN of the femoral head was assessed on radiographs. Logistic regression analysis was used to evaluate the independent risk factors for AVN. Chi-squared tests and Student’s t-tests were used for subgroup analyses to determine the risk factors for AVN.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 24 - 27
1 Oct 2019


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives

Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated.

Methods

This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (sd 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 451 - 458
1 Oct 2019
Kuroda Y Tanaka T Miyagawa T Kawai T Goto K Tanaka S Matsuda S Akiyama H

Objectives

Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries.

Methods

We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years (sd 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints.