Advertisement for orthosearch.org.uk
Results 881 - 900 of 2593
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1232 - 1238
1 Sep 2013
Wiater BP Boone CR Koueiter DM Wiater JM

Some surgeons are reluctant to perform a reverse total shoulder arthroplasty (RTSA) on both shoulders because of concerns regarding difficulty with activities of daily living post-operatively as a result of limited rotation of the shoulders. Nevertheless, we hypothesised that outcomes and patient satisfaction following bilateral RTSA would be comparable to those following unilateral RTSA. A single-surgeon RTSA registry was reviewed for patients who underwent bilateral staged RTSA with a minimum follow-up of two years. A unilateral RTSA matched control was selected for each shoulder in those patients undergoing bilateral procedures. The Constant–Murley score (CMS), American Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Values (SSV), visual analogue scale (VAS) for pain, range of movement and strength were measured pre- and post-operatively. The mean CMS, ASES, SSV, VAS scores, strength and active forward elevation were significantly improved (all p < 0.01) following each operation in those undergoing bilateral procedures. The mean active external rotation (p = 0.63 and p = 0.19) and internal rotation (p = 0.77 and p = 0.24) were not significantly improved. The improvement in the mean ASES score after the first RTSA was greater than the improvement in its control group (p = 0.0039). The improvement in the mean CMS, ASES scores and active forward elevation was significantly less after the second RTSA than in its control group (p = 0.0244, p = 0.0183, and p = 0.0280, respectively). Pain relief and function significantly improved after each RTSA in those undergoing a bilateral procedure. Bilateral RTSA is thus a reasonable form of treatment for patients with severe bilateral rotator cuff deficiency, although inferior results may be seen after the second procedure compared with the first. Cite this article: Bone Joint J 2013;95-B:1232–8


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1176 - 1182
14 Sep 2020
Mathews JA Kalson NS Tarrant PM Toms AD

Aims

The James Lind Alliance aims to bring patients, carers, and clinicians together to identify uncertainties regarding care. A Priority Setting Partnership was established by the British Association for Surgery of the Knee in conjunction with the James Lind Alliance to identify research priorities related to the assessment, management, and rehabilitation of patients with persistent symptoms after knee arthroplasty.

Methods

The project was conducted using the James Lind Alliance protocol. A steering group was convened including patients, surgeons, anaesthetists, nurses, physiotherapists, and researchers. Partner organizations were recruited. A survey was conducted on a national scale through which patients, carers, and healthcare professionals submitted key unanswered questions relating to problematic knee arthroplasties. These were analyzed, aggregated, and synthesized into summary questions and the relevant evidence was checked. After confirming that these were not answered in the current literature, 32 questions were taken forward to an interim prioritization survey. Data from this survey informed a shortlist taken to a final consensus meeting.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 563 - 566
1 Jul 1992
Kumta S Spinner R Leung P

Biodegradable implants made from polyglycolic and polylactic acid co-polymers undergo degradation by hydrolysis which results in loss of their mechanical strength. The degradation of 1.5 mm polyglycolide rods (Biofix) was studied after intramedullary and subcutaneous implantation in rabbits. Two weeks after implantation there was a 73% reduction in strength of the intramedullary implants and a 64% reduction in the subcutaneous implants. Polyglycolide implants were compared with Kirschner wires for intramedullary fixation of extra-articular fractures in the hand. In one group of patients fractures were fixed with a 1.5 mm intramedullary rod and in a similar group a Kirschner wire was used. In both a wire loop was added for extra fixation. At six months there was no significant difference between the two groups. There were no allergic reactions to the polyglycolide implants


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 406 - 408
1 May 1992
Nordsletten L Holm I Steen H Folleras G Bjerkreim I

We performed bilateral femoral shortening operations on 15 skeletally mature patients (11 women and four men). Their mean height pre-operatively was 193.5 cm and they were shortened by 5 to 9 cm. We used a subtrochanteric Z-osteotomy with an AO condylar plate in 11 patients, and mid-diaphyseal osteotomy with an intramedullary locking nail in four. After an average follow-up of 8.1 years, isokinetic muscle testing showed that muscle strength was reduced bilaterally in five patients. The strength ratio between hamstrings and quadriceps muscles was normal in all those treated by subtrochanteric shortening; in those shortened at the mid-shaft the quadriceps was relatively weaker. The result was rated as excellent by 11 patients, very good by three, and good by one


Bone & Joint Open
Vol. 1, Issue 11 | Pages 691 - 695
1 Nov 2020
Galloway AM Holton C Parnami V Wood M Craven J Green N Siddle HJ Richards S Comer C

Aims

Perthes’ disease is a condition which leads to necrosis of the femoral head. It is most commonly reported in children aged four to nine years, with recent statistics suggesting it affects around five per 100,000 children in the UK. Current treatment for the condition aims to maintain the best possible environment for the disease process to run its natural course. Management typically includes physiotherapy with or without surgical intervention. Physiotherapy intervention often will include strengthening/stretching programmes, exercise/activity advice, and, in some centres, will include intervention, such as hydrotherapy. There is significant variation in care with no consensus on which treatment option is best. The importance of work in this area has been demonstrated by the British Society for Children’s Orthopaedic Surgery through the James Lind Alliance’s prioritization of work to determine/identify surgical versus non-surgical management of Perthes’ disease. It was identified as the fourth-highest priority for paediatric lower limb surgery research in 2018.

Methods

Five UK NHS centres, including those from the NEWS (North, East, West and South Yorkshire) orthopaedic group, contributed to this case review, with each entre providing clinical data from a minimum of five children. Information regarding both orthopaedic and physiotherapeutic management over a two-year post-diagnosis period was reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 3 | Pages 474 - 491
1 Aug 1955
Salter N

1. The importance of accurate methods of measuring the strength of muscles and the amplitude of joint movements in man, both in clinical fields and as criteria of normal function, is discussed. 2. The advantages and disadvantages of subjective and objective methods are reviewed. 3. The main types of apparatus used for the assessment of muscle strength in both normal and clinical conditions are described. A dynamometer of the strain-gauge type is recommended. 4. Methods of measuring the amplitude of movements in man are also described. The protractor type arthrometer is thought to be the most suitable for routine clinical work, but for research purposes a radiographic method may be preferable. 5. The following factors, which must be considered if the measurements taken are to be of greatest use, are discussed: posture, test procedure, standards for comparison, nomenclature and normal variability


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 212 - 217
1 Mar 1999
Bonnard C Anastakis DJ van Melle G Narakas AO

We have assessed the final strength of the deltoid in 121 patients who had repair of isolated or combined lesions of the axillary (circumflex) nerve and were available for statistical analysis. Successful or useful results were achieved in 85% after grafting of isolated lesions. The strength was statistically better when patients had grafting of the axillary nerve within 5.3 months from the time of injury. The dramatic decrease in the rate of success seen with longer delays suggests that surgery should be undertaken within three months of injury. A statistically significant downward trend of the rate of success was noted with increasing age. The force and level of injury to the shoulder play an important role in the type, combination and level of nerve damage and the incidence of associated rotator-cuff, vascular and other injuries to the upper limb. Management of isolated and combined lesions of the axillary nerve after injury to the shoulder needs to be thorough and systematic


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 416 - 420
1 May 1993
Ogilvie-Harris D Demaziere A

We compared two treatments for tears of the rotator cuff of 1 to 4 cm in size. One group of 22 patients had an arthroscopic subacromial decompression and rotator-cuff debridement; the other comparable group of 23 patients had open repair and acromioplasty. Review was at 2 to 5 years postoperatively. Both groups had similar pain relief and range of active forward flexion, with significant improvement from the preoperative condition. The open repair group scored better for function, strength and overall score, but patient satisfaction was similar in the two groups. We recommend the use of arthroscopic subacromial decompression and debridement for low-demand patients who require mainly pain relief and range of movement. Open repair is necessary if strength and functional recovery are the prime objectives


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1355 - 1361
1 Oct 2011
Bollars P Luyckx J Innocenti B Labey L Victor J Bellemans J

High-flexion total knee replacement (TKR) designs have been introduced to improve flexion after TKR. Although the early results of such designs were promising, recent literature has raised concerns about the incidence of early loosening of the femoral component. We compared the minimum force required to cause femoral component loosening for six high-flexion and six conventional TKR designs in a laboratory experiment. Each TKR design was implanted in a femoral bone model and placed in a loading frame in 135° of flexion. Loosening of the femoral component was induced by moving the tibial component at a constant rate of displacement while maintaining the same angle of flexion. A stereophotogrammetric system registered the relative movement between the femoral component and the underlying bone until loosening occurred. Compared with high-flexion designs, conventional TKR designs required a significantly higher force before loosening occurred (p < 0.001). High-flexion designs with closed box geometry required significantly higher loosening forces than high-flexion designs with open box geometry (p = 0.0478). The presence of pegs further contributed to the fixation strength of components. We conclude that high-flexion designs have a greater risk for femoral component loosening than conventional TKR designs. We believe this is attributable to the absence of femoral load sharing between the prosthetic component and the condylar bone during flexion


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 580 - 581
1 Jul 1991
Ritter M Eizember L Keating E Faris P

We used the stainless steel cable grip system described by Dall and Miles in 1983 to fix trochanters in 40 hips after total arthroplasty with trochanteric osteotomy. The cable broke in 32.5% of the hips; the trochanter failed to unite in 37.5%. Significantly more cables broke when placed inside the femoral canal than when the cable was placed round the femoral shaft (58% as against 9.5%, difference p less than 0.01). The high incidence of breakage may have resulted from contact between the stainless steel cable and the titanium prosthesis, from the acute angulation, or because of the lower fatigue strength of stainless steel. Better results have been obtained using cables with a higher fatigue strength, passed outside the proximal femur


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 17 - 22
1 Jan 1988
Geesink R de Groot K Klein C

Implants of solid sintered hydroxyapatite form very tight bonds with living bone, but are susceptible to fatigue failure. This problem can be overcome by using plasma-sprayed apatite coatings on titanium implants. A very strong bond is formed between bone and this composite material; this was studied in canine bone with plug implants, avoiding any mechanical retention. Mechanical testing showed an interface shear strength at six weeks of 49 MPa with a maximum of 64 MPa after six months. There was histological evidence of direct bonding between the apatite coating and living bone while uncoated control plugs were easily extracted. The results indicate that apatite-coated implants can form a chemical fixation with a strength comparable to that of cortical bone itself. This fixation is far stronger than that provided by current cemented or uncemented fixation techniques


Bone & Joint 360
Vol. 9, Issue 3 | Pages 40 - 42
1 Jun 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 375 - 379
1 Apr 2002
Ferdinand RD MacLean JGB

The advantages and disadvantages of endoscopic compared with open carpal tunnelreleasearecontroversial. We have performed a prospective, randomised, blinded assessment in a district general hospital in order to determine if there was any demonstrable advantage in undertaking either technique. Twenty-five patients with confirmed bilateral idiopathic carpal tunnel syndrome were randomised to undergo endoscopic release by the single portal Agee technique to one hand and open release to the other. Independent preoperative and postoperative assessment was undertaken by a hand therapist who was blinded to the type of treatment. Follow-up was for 12 months. The operating time was two minutes shorter for the open technique (p < 0.005). At all stages of postoperative assessment, the endoscopic technique had no significant advantages in terms of return of muscle strength and assessment of hand function, grip strength, manual dexterity or sensation. In comparison with open release, single-portal endoscopic carpal tunnel release has a similar incidence of complications and a similar return of hand function, but is a slightly slower technique to undertake


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1582 - 1586
1 Nov 2020
Håberg Ø Foss OA Lian ØB Holen KJ

Aims

To assess if congenital foot deformity is a risk factor for developmental dysplasia of the hip (DDH).

Methods

Between 1996 and 2012, 60,844 children were born in Sør-Trøndelag county in Norway. In this cohort study, children with risk factors for DDH were examined using ultrasound. The risk factors evaluated were clinical hip instability, breech delivery, a family history of DDH, a foot deformity, and some syndromes. As the aim of the study was to examine the risk for DDH and foot deformity in the general population, children with syndromes were excluded. The information has been prospectively registered and retrospectively analyzed.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1527 - 1534
3 Nov 2020
Orita K Minoda Y Sugama R Ohta Y Ueyama H Takemura S Nakamura H

Aims

Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An in vitro wear simulator study showed that E1 reduced polyethylene wear. However there is no published information regarding in vivo wear. Previous reports suggest that newly introduced materials which reduce in vitro polyethylene wear do not necessarily reduce in vivo polyethylene wear. To assist in the evaluation of the newly introduced material before widespread use, we established an in vivo polyethylene wear particle analysis for TKA. The aim of this study was to compare in vivo polyethylene wear particle generation between E1 and conventional polyethylene (ArCom) in TKA.

Methods

A total of 34 knees undergoing TKA (17 each with ArCom or E1) were investigated. Except for the polyethylene insert material, the prostheses used for both groups were identical. Synovial fluid was obtained at a mean of 3.4 years (SD 1.3) postoperatively. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined by scanning electron microscopy.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1723 - 1734
1 Dec 2020
Fung B Hoit G Schemitsch E Godbout C Nauth A

Aims

The purpose of this study was to: review the efficacy of the induced membrane technique (IMT), also known as the Masquelet technique; and investigate the relationship between patient factors and technique variations on the outcomes of the IMT.

Methods

A systematic search was performed in CINAHL, The Cochrane Library, Embase, Ovid MEDLINE, and PubMed. We included articles from 1 January 1980 to 30 September 2019. Studies with a minimum sample size of five cases, where the IMT was performed primarily in adult patients (≥ 18 years old), in a long bone were included. Multivariate regression models were performed on patient-level data to determine variables associated with nonunion, postoperative infection, and the need for additional procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 235 - 240
1 Mar 2001
Dias JJ Bhowal B Wildin CJ Thompson JR

The different attributes of the Patient Evaluation Measure (PEM) questionnaire were investigated in 80 patients with a fracture of the scaphoid. Assessments were made at 2, 8, 12, 26 and 52 weeks. Reliability was assessed by measurement of the internal consistency of the different questions in 275 completed PEM forms. Cronbach’s alpha, which needs to lie between 0.7 and 0.9, was 0.9 for the PEM. Pain, tenderness, swelling, wrist movement and grip strength correlated with the PEM score confirming the validity of the assessment. Changes in the different variables between visits correlated significantly with changes in the PEM score; its effect size and standardised response mean were comparable to those of grip strength and movement, confirming the responsiveness of this questionnaire. Gender, dominance and the side injured did not influence the scores. Older patients had a poorer outcome as assessed by the score which appeared to be a true effect and not age bias. Our study confirmed that the PEM is a reliable, valid and responsive instrument in assessing outcomes of disorders of the hand


Bone & Joint Open
Vol. 1, Issue 11 | Pages 683 - 690
1 Nov 2020
Khan SA Asokan A Handford C Logan P Moores T

Background

Due to the overwhelming demand for trauma services, resulting from increasing emergency department attendances over the past decade, virtual fracture clinics (VFCs) have become the fashion to keep up with the demand and help comply with the BOA Standards for Trauma and Orthopaedics (BOAST) guidelines. In this article, we perform a systematic review asking, “How useful are VFCs?”, and what injuries and conditions can be treated safely and effectively, to help decrease patient face to face consultations. Our primary outcomes were patient satisfaction, clinical efficiency and cost analysis, and clinical outcomes.

Methods

We performed a systematic literature search of all papers pertaining to VFCs, using the search engines PubMed, MEDLINE, and the Cochrane Database, according to the Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) checklist. Searches were carried out and screened by two authors, with final study eligibility confirmed by the senior author.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1549 - 1554
1 Nov 2020
Schwartz AM Farley KX Boden SH Wilson JM Daly CA Gottschalk MB Wagner ER

Aims

The impact of tobacco use on readmission and medical and surgical complications has been documented in hip and knee arthroplasty. However, there remains little information about the effect of smoking on the outcome after total shoulder arthroplasty (TSA). We hypothesized that active smokers are at an increased risk of poor medical and surgial outcomes after TSA.

Methods

Data for patients who underwent arthroplasty of the shoulder in the USA between January 2011 and December 2015 were obtained from the National Readmission Database, and 90-day readmissions and complications were documented using validated coding methods. Multivariate regression analysis was performed to quantify the risk of smoking on the outcome after TSA, while controlling for patient demographics, comorbidities, and hospital-level confounding factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 881 - 883
1 Sep 1990
Magnussen P Harvey F Tonkin M

We reviewed 21 patients with 22 ruptures of the extensor pollicis longus at a mean of 5.3 years after transfer of the extensor indicis proprius tendon. Of these, 19 with 21 transfers described the result as good, and two as fair. The mean deficit of extension between the operated and unoperated thumbs was 1.4 cm, and the mean flexion deficit 0.6 cm. Pressure gauge measurements showed that the strength of the transfer was 51% of that of the uninjured extensor. The two fair results had an extensor lag of over 1.5 cm. Independent extension of the index was maintained in all patients, none having a discernible lag, but the strength of index extension was reduced to 49% of that of the normal finger. There was no evidence of functional loss. Extensor indicis proprius transfer for rupture of the extensor pollicis longus tendon is a simple and reliable procedure with few complications. It gives satisfactory long-term extension of the thumb