Advertisement for orthosearch.org.uk
Results 881 - 900 of 1298
Results per page:
Bone & Joint 360
Vol. 5, Issue 3 | Pages 31 - 32
1 Jun 2016


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 990 - 996
1 Jul 2016
Fujiwara H Makino T Yonenobu K Honda H Kaito T

Aims

In this prospective observational study, we investigated the time-dependent changes and correlations of upper arm performance tests (ten-second test and Simple Test for Evaluating Hand Function (STEF), the Japanese Orthopaedic Association (JOA) score, and the JOA Cervical Myelopathy Evaluation Questionnaire (JOACMEQ) in 31 patients with cervical myelopathy who had undergone surgery.

Patients and Methods

We hypothesised that all the indices correlate with each other, but show slightly different recovery patterns, and that the newly described JOACMEQ is a sensitive outcome measure.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1349 - 1354
1 Oct 2014
Conway J Mansour J Kotze K Specht S Shabtai L

The treatment of infected nonunions is difficult. Antibiotic cement-coated (ACC) rods provide stability as well as delivering antibiotics. We conducted a review of 110 infected nonunions treated with ACC rods. Patients were divided into two groups: group A (67 patients) with an infected arthrodesis, and group B (43 patients) with an infected nonunion in a long bone. In group A, infected arthrodesis, the success rate after the first procedure was 38/67 (57%), 29/67 (43%) required further surgery for either control of infection or non-union. At last follow-up, five patients required amputation, representing a limb salvage rate of 62/67 (93%) overall. In all, 29/67 (43%) presented with a bone defect with a mean size of 6.78 cm (2 to 25). Of those with a bone defect, 13/29 (45%) required further surgery and had a mean size of defect of 7.2 cm (3.5 to 25). The cultures were negative in 17/67 (26%) and the most common organism cultured was methicillin-resistant staphylococcus aureus (MRSA) (23/67, (35%)). In group B, long bones nonunion, the success rate after the first procedure was 26/43 (60%), 17/43 (40%) required further surgery for either control of infection or nonunion. The limb salvage rate at last follow-up was 43/43 (100%). A total of 22/43 (51%) had bone defect with a mean size of 4.7 cm (1.5 to 11.5). Of those patients with a bone defect, 93% required further surgery with a mean size of defect of 5.4 cm (3 to 8.5). The cultures were negative in 10/43 (24%) and the most common organism cultured was MRSA, 15/43 (35%). ACC rods are an effective form of treatment for an infected nonunion, with an acceptable rate of complications.

Cite this article: Bone Joint J 2014; 96-B:1349–54


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 945 - 951
1 Jul 2016
Clement ND MacDonald D Dall GF Ahmed I Duckworth AD Shalaby HS McKinley J

Aims

To examine the mid-term outcome and cost utility of the BioPro metallic hemiarthroplasty for the treatment of hallux rigidius.

Patients and Methods

We reviewed 97 consecutive BioPro metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum follow-up of five years. There were 19 men and 61 women; their mean age was 55 years (22 to 74). No patient was lost to follow-up.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 17 - 19
1 Aug 2014

The August 2014 Foot & Ankle Roundup360 looks at: calcaneotibial nail in ankle fractures; reamer irrigator aspirator for ankle fusion; periprosthetic bone infection; infection in ankle fixation; cheap and cheerful OK in MTP fusion plates; sliding fibular graft for peroneal tendon pathology and fusion for failed ankle replacement.


Bone & Joint Research
Vol. 2, Issue 6 | Pages 102 - 111
1 Jun 2013
Patel RA Wilson RF Patel PA Palmer RM

Objectives

To review the systemic impact of smoking on bone healing as evidenced within the orthopaedic literature.

Methods

A protocol was established and studies were sourced from five electronic databases. Screening, data abstraction and quality assessment was conducted by two review authors. Prospective and retrospective clinical studies were included. The primary outcome measures were based on clinical and/or radiological indicators of bone healing. This review specifically focused on non-spinal orthopaedic studies.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 31 - 32
1 Jun 2015
York P Mauffrey C


Bone & Joint 360
Vol. 4, Issue 3 | Pages 35 - 36
1 Jun 2015
Clarke A


Bone & Joint 360
Vol. 5, Issue 2 | Pages 16 - 18
1 Apr 2016


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 229 - 234
1 Feb 2015
Choi W Lee HJ Kim D Lee C Lee BG Kim J Lee K

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (sd 0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (sd 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (sd 12.2) in group 1 and 10.5 (sd 13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (sd 14.04) in group 1 and 82.6 (sd 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson’s correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient –0.26, p = 0.02).

We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome.

Cite this article: Bone Joint J 2015;97-B:229–34.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 23 - 24
1 Jun 2015

The June 2015 Trauma Roundup360 looks at: HIV-related implant surgery in trauma; Major transfusion under the spotlight; Surgery and mortality in elderly acetabular fractures; Traction pin safety; Obesity and trauma; Salvage of acetabular fixation in the longer term


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 957 - 962
1 Jul 2015
Yamazaki H Uchiyama S Komatsu M Hashimoto S Kobayashi Y Sakurai T Kato H

There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures.

Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance.

There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation (sd) 0.7) and 0.7 mm (sd 0.7) and 0.6 mm (sd 0.6) and 0.4 mm (sd 0.5), respectively; p = 0.18 and p = 0.35).

Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate.

Cite this article: Bone Joint J 2015; 97-B:957–62.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 654 - 659
1 May 2016
Garala K Taub NA Dias JJ

Aims

This study explores the epidemiology of patients with a fracture of the scaphoid presenting to a regional teaching hospital.

Patients and Methods

All patients with a confirmed fracture of the scaphoid over a retrospective period between January 2010 and May 2013 were included. Their demographics, deprivation status and when the fracture occurred was noted and assessed. There were 415 fractures in 365 males and 50 females.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 178 - 184
1 May 2016
Dean BJF Jones LD Palmer AJR Macnair RD Brewer PE Jayadev C Wheelton AN Ball DEJ Nandra RS Aujla RS Sykes AE Carr AJ

Objectives

The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics and the nature of the surgical treatment.

Methods

A total of ten consecutive patients undergoing surgery for the treatment of a proximal humeral fracture from each of 11 United Kingdom hospitals were retrospectively identified over a 15 month period between January 2014 and March 2015. Data gathered for the 110 patients included patient demographics, injury characteristics, mode of surgical fixation, the grade of operating surgeon and the cost of the surgical implants.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 16 - 18
1 Feb 2016


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1436 - 1440
1 Nov 2014
Henderson ER O’Connor MI Ruggieri P Windhager R Funovics PT Gibbons CL Guo W Hornicek FJ Temple HT Letson GD

Previous classification systems of failure of limb salvage focused primarily on endoprosthetic failures and lacked sufficient depth for the effective study of the causes of failure. In order to address these inadequacies, the International Society of Limb Salvage (ISOLS) formed a committee to recommend revisions of the previous systems. The purpose of this study was to report on their recommendations. The modifications were prepared using an earlier, evidence-based model with subclassification based on the existing medical literature. Subclassification for all five primary types of failure of limb salvage following endoprosthetic reconstruction were formulated and a complementary system was derived for the failure of biological reconstruction. An additional classification of failure in paediatric patients was also described.

Limb salvage surgery presents a complex array of potential mechanisms of failure, and a complete and precise classification of types of failure is required. Earlier classification systems lacked specificity, and the evidence-based system outlined here is designed to correct these weaknesses and to provide a means of reporting failures of limb salvage in order to allow the interpretation of outcome following reconstructive surgery.

Cite this article: Bone Joint J 2014;96-B:1436–40.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 145 - 152
1 Apr 2016
Bodalia PN Balaji V Kaila R Wilson L

Objectives

We performed a systematic review of the literature to determine the safety and efficacy of bone morphogenetic protein (BMP) compared with bone graft when used specifically for revision spinal fusion surgery secondary to pseudarthrosis.

Methods

The MEDLINE, EMBASE and Cochrane Library databases were searched using defined search terms. The primary outcome measure was spinal fusion, assessed as success or failure in accordance with radiograph, MRI or CT scan review at 24-month follow-up. The secondary outcome measure was time to fusion.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 37 - 40
1 Feb 2016
Ribbans W


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 668 - 674
1 May 2015
Röhm J Zwicky L Horn Lang T Salentiny Y Hintermann B Knupp M

Talonavicular and subtalar joint fusion through a medial incision (modified triple arthrodesis) has become an increasingly popular technique for treating symptomatic flatfoot deformity caused by posterior tibial tendon dysfunction.

The purpose of this study was to look at its clinical and radiological mid- to long-term outcomes, including the rates of recurrent flatfoot deformity, nonunion and avascular necrosis of the dome of the talus.

A total of 84 patients (96 feet) with a symptomatic rigid flatfoot deformity caused by posterior tibial tendon dysfunction were treated using a modified triple arthrodesis. The mean age of the patients was 66 years (35 to 85) and the mean follow-up was 4.7 years (1 to 8.3). Both clinical and radiological outcomes were analysed retrospectively.

In 86 of the 95 feet (90.5%) for which radiographs were available, there was no loss of correction at final follow-up. In all, 14 feet (14.7%) needed secondary surgery, six for nonunion, two for avascular necrosis, five for progression of the flatfoot deformity and tibiotalar arthritis and one because of symptomatic overcorrection. The mean American Orthopaedic Foot and Ankle Society Hindfoot score (AOFAS score) at final follow-up was 67 (between 16 and 100) and the mean visual analogue score for pain 2.4 points (between 0 and 10).

In conclusion, modified triple arthrodesis provides reliable correction of deformity and a good clinical outcome at mid- to long-term follow-up, with nonunion as the most frequent complication. Avascular necrosis of the talus is a rare but serious complication of this technique.

Cite this article: Bone Joint J 2015; 97-B:668–74.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 50 - 53
1 Jan 2016
Konan S Garbuz DS Masri BA Duncan CP

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that reason, and while awaiting intermediate-term results of more recently introduced designs of this junction, non-modularity has attracted attention, at least for straightforward revision cases.

We review the risks and causes of fracture of tapered titanium modular revision stems and present an argument in favour of the more selective use of modular designs.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):50–3.