Advertisement for orthosearch.org.uk
Results 841 - 860 of 1999
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 688 - 692
1 Sep 1993
Barrack R Burke D Cook S Skinner H Harris W

We report complications from the use of modular components in 20 hip replacements in 18 patients. Fifteen complications (in 13 patients) were related to failure of a modular interface after operation. Femoral head detachment from its trunnion was seen in 6 hips from trauma (3), reduction of a dislocation (2), and normal activity (1). In one case the base of the trunnion fractured below an extra-long modular head. In seven other hips the modular polyethylene liner dislodged from its shell, causing severe damage to the shell in four cases with extensive metallosis. In one other hip an asymmetrical polyethylene liner rotated, resulting in impingement of the femoral component and recurrent dislocation. Operative errors were seen in five cases: implantation of a trial acetabular component in one; and mismatching between the size of the femoral head and the acetabular component in the others. Surgeons who use hip replacements with modular components should be aware of the potential for operative error and of the importance of early treatment for postoperative mechanical failure


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 483 - 487
1 May 1993
Suzuki S

Sixty-nine hips in 62 patients were treated by the Pavlik harness for congenital dislocation. Ultrasonography showed three degrees of residual head displacement when the harness was first applied. In type A, the femoral head showed contact with the inner posterior wall of the acetabulum. In type B, it contacted the posterior margin of the socket, with its centre at or anterior to the acetabular rim. In type C, the femoral head was displaced outside the socket, with its centre posterior to the acetabular rim. All 51 hips with type A displacement remained reduced. Of nine hips of type B, five were reduced, but the other four were not. None of the nine hips with type C dislocation became reduced with continued use of the harness. The Pavlik harness is indicated for type A and some type B dislocations, but the latter need daily ultrasound monitoring, with a change in method of treatment if type C displacement appears or if the hip is not reduced within one or two weeks. Treatment by Pavlik harness is not indicated in hips with type C dislocations


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 310 - 314
1 Mar 1998
Ismail AM Macnicol MF

We compared the prognostic value of the Catterall grouping, the Salter-Thompson grading, the arthrographic shape of the femoral head, and the Herring lateral pillar grouping during the fragmentation stage of Perthes’ disease in 73 patients with 81 affected hips. Radiographs were available for study from the onset of the disease until skeletal maturity. We used the Stulberg classification to assess outcome. The Herring grade and arthrographic sphericity proved to be the best predictors of final outcome. Combining these two values further increased the predictive value. All but one patient in Herring group A achieved an excellent outcome. In Herring group B, the age of the child and the sphericity of the femoral head influenced the end result. If the child was less than seven years old at the onset of symptoms the prognosis was invariably good and all spherical hips in group B had a good outcome with Stulberg grades 1 or 2. Moderately and severely deformed hips on arthrography resulted in Stulberg 3 and 4 hips. None of the hips in Herring group C had a normal appearance at maturity and the outcome was not significantly influenced by the age at onset or the arthrographic appearance


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 272 - 278
1 Aug 1976
Fredensborg N

The late results of early treatment of congenital dislocation of the hip in the von Rosen splint have been recorded in a follow-up study of 111 children with an average age of ten years (range eight to sixteen). The clinical diagnosis had been made within two days of birth and in most cases confirmed by radiological examination. Splintage was in all cases begun within the first few days and maintained for an average period of ten weeks. Two cases of failure of the initial treatment were encountered but had good final results. The follow-up study included a radiological examination in which were recorded the general configuration of the joint, the CE-angle described by Wiberg, the presence or absence of an os acetabuli and the roundness of the femoral head. The findings were compared with those in a control group of 222 normal children. All the treated hips developed normally except for a single case of minor dysplasia and a single case of slight enlargement of the femoral head and neck following appearances suggestive of avascular necrosis at the age of two years


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 167 - 174
1 May 1975
Trevor D Johns DL Fixsen JA

The results in 102 acetabuloplasties have been assessed in eighty-six patients, with a minimum follow-up of five years. Clinical and radiological assessment was carried out according to a score system very similar to that used in previous studies, and the results were expressed as excellent, good, fair and poor according to the score obtained. Any hip requiring further stabifising procedures was automatically grouped as a failure. Subtrochanteric femoral osteotomy was used when femoral anteversion was excessive. The results revealed that 73 per cent of the hips were satisfactory (excellent or good) overall, but that a steady deterioration was evident when the five-and fifteen-year groups were compared. Few of the hips were regarded as normal on radiological grounds. Homologous bone bank rib was found to be the most satisfactory graft material. Coxa magna was the most common abnormality that was consistent with a good or excellent result. Avascular necrosis of the femoral head was found in only six hips; it was more commonly present in patients subjected to previous operation. Concentric reduction of the femoral head is essential if acetabuloplasty is to maintain stability of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 631 - 635
1 Jul 1996
Suzuki S Kashiwagi N Kasahara Y Seto Y Futami T

We analysed the incidence of avascular necrosis in 101 hips of 90 infants with congenital dislocation treated with the Pavlik harness and followed up for more than one year. Using ultrasonography in the flexed-abducted position the hips were classified as type A when the femoral head was displaced posteriorly, but within the socket and making contact with the posterior inner wall of the acetabulum; type B when it was in contact with the posterior margin of the acetabulum, with its centre at this level or anterior to it; and type C when it was displaced out of the socket, with its centre posterior to the posterior rim of the acetabulum. Eighty-seven hips were reduced by the harness (86%), and seven of these developed avascular necrosis (8%). All 69 hips with type-A dislocation were reduced, and only one (1.4%) showed slight avascular necrosis. Eighteen (78.3%) of 23 hips with type-B dislocation were reduced, and six developed avascular necrosis (33.3%). In one hip, the femoral head was severely damaged. None of the nine hips with type-C dislocation was reduced in the harness. We conclude that the Pavlik harness is indicated for type-A, but not for type-B or type-C dislocations


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 177 - 182
1 Mar 2001
Taylor AH Shannon M Whitehouse SL Lee MB Learmonth ID

We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 ± 14.7 to 94 ± 6.8. Radiologically, there was no evidence of acetabular migration. The rate of revision for the femoral component was 8.6%, three being undertaken for loosening and three to allow downsizing of the femoral head. The rate of revision for the acetabular component was 7.1% (five cups). At the time of revision none of the cups was clinically loose, and only required the liner to be changed. The rate of complications was low with no case of deep infection or dislocation, but nine of the 76 hips (11.8%) showed grade-III heterotopic ossification. Previous studies of patients undergoing cemented total hip arthroplasty for the treatment of advanced avascular necrosis have indicated a high incidence of loosening of the acetabular component. Our findings show good medium-term results using the Harris Galante Porous cup for acetabular reconstruction, together with a variety of cemented femoral components, for the treatment of this difficult problem


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 721 - 726
1 Jun 2006
Girard J Lavigne M Vendittoli P Roy AG

We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within . sd. 4 mm in 14 (25%) of those with THA and in 28 (57%) of the patients receiving SRA (p < 0.001). In the THA group, the leg was lengthened by a mean of 2.6 mm (−6.04 to +12.9), whereas it was shortened by a mean of 1.9 mm (−7.1 to +2.05) in the SRA group, compared with the contralateral side. Leg-length inequality was restored within . sd. 4 mm in 42 (86%) of the SRA and 33 (60%) of the THA patients. The radiological parameters of acetabular reconstruction were similar in both groups. Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter femoral head avoided over-lengthening of the limb or increased offset to improve soft-tissue tension as occurs sometimes in THA. In a subgroup of patients with significant pre-operative deformity, restoration of the normal hip anatomy with lower pre-operative femoral offset or significant shortening of the leg was still possible with SRA


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 59 - 65
1 Jan 2002
Nozawa M Shitoto K Matsuda K Maezawa K Kurosawa H

Between 1986 and 1990, we carried out 55 rotational acetabular osteotomies in 54 patients with acetabular dysplasia. Five hips were lost to follow-up. Of the 50 remaining, the degenerative changes were classified according to the criteria of Tönnis as grade 0 in 23, grade 1 in 16 and grade 2 in 11. The mean age of the three men and 46 women at the time of operation was 31.8 years (13 to 53). The mean follow-up was 137 months (120 to 174). At the most recent follow-up, 48 patients had satisfactory relief from pain. There was a slight decrease in the range of movement, particularly of flexion, in 18 hips. Radiologically, all osteotomies had united satisfactorily. There was radiological evidence of improvement in degenerative changes in 13 hips (5 grade 1 and 8 grade 2). Ten deteriorated (5 grade 0, 3 grade 1, and 2 grade 2) and one required total hip arthroplasty ten years after osteotomy. The osteoarthritis in the two hips with an associated valgus osteotomy progressed. The changes in radiological indices such as the centre-edge angle, acetabular femoral head index, acetabular root obliquity and horizontal or vertical displacement of the femoral head showed no statistical difference (unpaired Student’s t-test) between the patients with radiological progression and those with and without improvement


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 176 - 179
1 Apr 1982
Bertol P Macnicol M Mitchell G

Over the 10-year period 1969 to 1978, 271 consecutive cases of congenital dislocation of the hip were diagnosed at birth. Standard anteroposterior radiographs of the pelvis were obtained routinely and were analysed retrospectively. The medial gap, a measure of the separation between the proximal femur and the pelvic wall, was found to be significantly increased in cases with unilateral or bilateral dislocation when compared to normal. A medial greater than five millimetres is indicative of femoral head displacement and is of value where the clinical diagnosis is uncertain. The rate of missed dislocation at birth was 0.6 cases per thousand. Treatment with the Malmo splint was the normal routine. The Pavlik harness was applied if splintage was poorly tolerated by the infant, or in the rare instance of limited hip abduction. Failure to maintain reduction by splintage occurred in 3.3 per cent. The incidence of pressure deformities of the femoral head was 2.95 per cent and there was a residual deformity in later childhood of 1.1 per cent. It is presumed that this lesion can be attributed to the effect of splintage and it was notably avoided in the later period of the review when greater mobility of the abducted hips was encouraged


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 625 - 630
1 Jul 1996
Joseph B Srinivas G Thomas R

We analysed the short-term outcome after varus osteotomy for Perthes’ disease in 48 older children from south-west India, comparing them with 30 historical controls. The children were between 7 and 12 years of age at the onset of the disease. All had stage-I or stage-II disease, with half or more of the epiphysis involved. The operated children had an open-wedge subtrochanteric varus osteotomy with derotation or extension and a trochanteric epiphyseodesis. Weight-bearing was avoided until late stage III. The non-operated children had been treated symptomatically by conservative methods. At the time of healing, 62.5% of the operated group had spherical femoral heads compared with 20% of those treated non-operatively (p < 0.001). Of the operated children with Catterall group-IV involvement, 48% had good results as against 24% of the non-operated group (p < 0.05). The percentage increase in the radius of the affected femoral head compared with the normal side was significantly lower in children who had operations (14.68 v 25.65; p < 0.001). We have shown that the short-term results of early surgical containment in children over seven years of age are satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 230 - 235
1 Feb 2007
Nakamura J Kamegaya M Saisu T Someya M Koizumi W Moriya H

We reviewed the medical records of 115 patients with 130 hips with developmental dysplasia with complete dislocation in the absence of a neuromuscular disorder, spontaneous reduction with a Pavlik harness, and a minimum of 14 years’ follow-up. The mean age at the time of harness application was 4.8 months (1 to 12) and the mean time spent in the harness was 6.1 months (3 to 12). A total of 108 hips (83.1%) were treated with the harness alone and supplementary surgery for residual acetabular dysplasia, as defined by an acetabular index > 30°, was performed in 22 hips (16.9%). An overall satisfactory outcome (Severin grade I or II) was achieved in 119 hips (91.5%) at a mean follow-up of 16 years (14 to 32) with a follow-up rate of 75%. Avascular necrosis of the femoral head was noted in 16 hips (12.3%), seven of which (44%) underwent supplementary surgery and nine (56%) of which were classified as satisfactory. The acetabular index was the most reliable predictor of residual acetabular dysplasia


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 556 - 567
1 May 2020
Park JW Lee Y Lee YJ Shin S Kang Y Koo K

Deep gluteal syndrome is an increasingly recognized disease entity, caused by compression of the sciatic or pudendal nerve due to non-discogenic pelvic lesions. It includes the piriformis syndrome, the gemelli-obturator internus syndrome, the ischiofemoral impingement syndrome, and the proximal hamstring syndrome. The concept of the deep gluteal syndrome extends our understanding of posterior hip pain due to nerve entrapment beyond the traditional model of the piriformis syndrome. Nevertheless, there has been terminological confusion and the deep gluteal syndrome has often been undiagnosed or mistaken for other conditions. Careful history-taking, a physical examination including provocation tests, an electrodiagnostic study, and imaging are necessary for an accurate diagnosis.

After excluding spinal lesions, MRI scans of the pelvis are helpful in diagnosing deep gluteal syndrome and identifying pathological conditions entrapping the nerves. It can be conservatively treated with multidisciplinary treatment including rest, the avoidance of provoking activities, medication, injections, and physiotherapy.

Endoscopic or open surgical decompression is recommended in patients with persistent or recurrent symptoms after conservative treatment or in those who may have masses compressing the sciatic nerve.

Many physicians remain unfamiliar with this syndrome and there is a lack of relevant literature. This comprehensive review aims to provide the latest information about the epidemiology, aetiology, pathology, clinical features, diagnosis, and treatment.

Cite this article: Bone Joint J 2020;102-B(5):556–567.


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 4 | Pages 639 - 649
1 Nov 1971
Somerville EW

1. Perthes' disease is an ischaemic lesion of the ossific nucleus of the head of the femur which may vary both in extent and degree. It is probably never quite complete. 2. When part of the ossific nucleus only is affected, as is usually the case, it is almost invariably the antero-lateral part. 3. The process of absorption of the damaged bone is complete radiologically before there is radiological evidence of reossification. 4. Reossification always occurs in Perthes' disease. 5. The aim of treatment must be to see that the mould in which the head is shaped is the right shape when ossification occurs. 6. The deformity of the head of the femur does not occur from pressure alone, but from pressure combined with subluxation. Full unrestricted weight-bearing can be allowed with safety on a femoral head in which there are ischaemic changes provided the femoral head is well contained. 7. The time of treatment can be very greatly reduced by using operation to correct the subluxation instead of relying on external splintage. This can be achieved by subtrochanteric osteotomy with rotation, or rotation combined with varus angulation. 8. Perthes' disease and avascular necrosis of the head of the femur are different conditions with different characteristics. 9. Suggestions are made as to the nature of the disease in relation to absorption, continued growth and reossification


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 1 | Pages 136 - 143
1 Feb 1971
Griffiths WEG Swanson SAV Freeman MAR

1. Thirty-seven specimens of the proximal third of the human femur were subjected to cyclically varying loads applied in a physiological direction to the femoral head, having maximum values of from four to thirteen times body weight. 2. Ten of these specimens sustained subcapital fractures of the femoral neck after numbers of cycles of loading varying from 123 to 8,193. 3. The maximum value of cyclic load needed to give fatigue fracture after 10,000 or fewer cycles was found to vary from about twelve times the body weight at ages twenty to fifty to about five times the body weight at age seventy or more. 4. In youth and in middle age the load levels mentioned above are greater than those encountered in normal living, but are comparable to those which may be applied to the femoral head during activities known to produce "fatigue" fractures clinically in young adults. 5. In the elderly the load levels mentioned above are within the range that can be applied in normal living. It is inferred that some femoral neck fractures in the elderly may be fatigue fractures caused by the cyclic loading of normal walking


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 178 - 184
1 Mar 1996
Marston RA Cobb AG Bentley G

From 1982 to 1987, we randomised prospectively 413 patients requiring primary total hip replacements to receive either a Stanmore or Charnley prosthesis. They were reviewed by an independent observer in an attempt to correlate a number of factors including femoral head size with longevity. There were 213 Stanmore hips and 200 Charnley prostheses. At five to ten years (mean 6.5) 76 patients had died and 16 arthroplasties had required revision. Seven were radiologically loose in asymptomatic patients. There was only one case of deep infection. We found no difference statistically in the clinical outcome or in the revision rate of 4% in the two types of prosthesis. The revision rate was greater for trainees than for senior operating surgeons, and there were recognisable technical errors in seven of the nine Stanmore, and four of the seven Charnley replacements which required revision. Retrospective radiological analysis of a random subset of 51 Charnley and 57 Stanmore femoral components showed no difference in femoral subsidence, but in 14 patients who had had bilateral replacements with one femoral component of each type, there was greater early subsidence of the Stanmore prosthesis. Our results confirm that conventional cemented total hip replacements give acceptable results in a general teaching unit, and we found no evidence of any effect of the size of the femoral head on wear or loosening at five to ten years


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 960 - 969
1 Aug 2019
Odgaard A Laursen MB Gromov K Troelsen A Kristensen PW Schrøder H Madsen F Overgaard S

Aims

The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check.

Materials and Methods

Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


Bone & Joint 360
Vol. 8, Issue 6 | Pages 39 - 41
1 Dec 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 280 - 285
1 Mar 1996
Wroblewski BM Siney PD Dowson D Collins SN

We report the findings from independent prospective clinical and laboratory-based joint-simulator studies of the performance of ceramic femoral heads of 22.225 mm diameter in cross-linked polyethylene (XLP) acetabular cups. We found remarkable qualitative and quantitative agreement between the clinical and simulator results for the wear characteristics with time, and confirmed that ceramic femoral heads penetrate the XLP cups at only about half the rate of otherwise comparable metal heads. In the clinical study, 19 hips in 17 patients were followed for an average of 77 months. In the hip-joint simulator a similar prosthesis was tested for 7.3 million cycles. Both clinical and simulator results showed relatively high rates of penetration over the first 18 months or 1.5 million cycles, followed by a very much lower wear thereafter. Once an initial bedding-in of 0.2 mm to 0.4 mm had taken place the subsequent rates of penetration were very small. The initial clinical wear during bedding-in averaged 0.29 mm/year; subsequent progression was an order of magnitude lower at about 0.022 mm/year, lower than the 0.07 mm/year in metal-to-UHMWP Charnley LFAs. Our results show the excellent tribological features of alumina-ceramic-to-XLP implants, and also confirm the value of well-designed joint simulators for the evaluation of total joint replacements