We report complications from the use of modular components in 20 hip replacements in 18 patients. Fifteen complications (in 13 patients) were related to failure of a modular interface after operation.
Sixty-nine hips in 62 patients were treated by the Pavlik harness for congenital dislocation. Ultrasonography showed three degrees of residual head displacement when the harness was first applied. In type A, the
We compared the prognostic value of the Catterall grouping, the Salter-Thompson grading, the arthrographic shape of the
The late results of early treatment of congenital dislocation of the hip in the von Rosen splint have been recorded in a follow-up study of 111 children with an average age of ten years (range eight to sixteen). The clinical diagnosis had been made within two days of birth and in most cases confirmed by radiological examination. Splintage was in all cases begun within the first few days and maintained for an average period of ten weeks. Two cases of failure of the initial treatment were encountered but had good final results. The follow-up study included a radiological examination in which were recorded the general configuration of the joint, the CE-angle described by Wiberg, the presence or absence of an os acetabuli and the roundness of the
The results in 102 acetabuloplasties have been assessed in eighty-six patients, with a minimum follow-up of five years. Clinical and radiological assessment was carried out according to a score system very similar to that used in previous studies, and the results were expressed as excellent, good, fair and poor according to the score obtained. Any hip requiring further stabifising procedures was automatically grouped as a failure. Subtrochanteric femoral osteotomy was used when femoral anteversion was excessive. The results revealed that 73 per cent of the hips were satisfactory (excellent or good) overall, but that a steady deterioration was evident when the five-and fifteen-year groups were compared. Few of the hips were regarded as normal on radiological grounds. Homologous bone bank rib was found to be the most satisfactory graft material. Coxa magna was the most common abnormality that was consistent with a good or excellent result. Avascular necrosis of the
We analysed the incidence of avascular necrosis in 101 hips of 90 infants with congenital dislocation treated with the Pavlik harness and followed up for more than one year. Using ultrasonography in the flexed-abducted position the hips were classified as type A when the
We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the
We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within . sd. 4 mm in 14 (25%) of those with THA and in 28 (57%) of the patients receiving SRA (p <
0.001). In the THA group, the leg was lengthened by a mean of 2.6 mm (−6.04 to +12.9), whereas it was shortened by a mean of 1.9 mm (−7.1 to +2.05) in the SRA group, compared with the contralateral side. Leg-length inequality was restored within . sd. 4 mm in 42 (86%) of the SRA and 33 (60%) of the THA patients. The radiological parameters of acetabular reconstruction were similar in both groups. Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter
Between 1986 and 1990, we carried out 55 rotational acetabular osteotomies in 54 patients with acetabular dysplasia. Five hips were lost to follow-up. Of the 50 remaining, the degenerative changes were classified according to the criteria of Tönnis as grade 0 in 23, grade 1 in 16 and grade 2 in 11. The mean age of the three men and 46 women at the time of operation was 31.8 years (13 to 53). The mean follow-up was 137 months (120 to 174). At the most recent follow-up, 48 patients had satisfactory relief from pain. There was a slight decrease in the range of movement, particularly of flexion, in 18 hips. Radiologically, all osteotomies had united satisfactorily. There was radiological evidence of improvement in degenerative changes in 13 hips (5 grade 1 and 8 grade 2). Ten deteriorated (5 grade 0, 3 grade 1, and 2 grade 2) and one required total hip arthroplasty ten years after osteotomy. The osteoarthritis in the two hips with an associated valgus osteotomy progressed. The changes in radiological indices such as the centre-edge angle, acetabular
Over the 10-year period 1969 to 1978, 271 consecutive cases of congenital dislocation of the hip were diagnosed at birth. Standard anteroposterior radiographs of the pelvis were obtained routinely and were analysed retrospectively. The medial gap, a measure of the separation between the proximal femur and the pelvic wall, was found to be significantly increased in cases with unilateral or bilateral dislocation when compared to normal. A medial greater than five millimetres is indicative of
We analysed the short-term outcome after varus osteotomy for Perthes’ disease in 48 older children from south-west India, comparing them with 30 historical controls. The children were between 7 and 12 years of age at the onset of the disease. All had stage-I or stage-II disease, with half or more of the epiphysis involved. The operated children had an open-wedge subtrochanteric varus osteotomy with derotation or extension and a trochanteric epiphyseodesis. Weight-bearing was avoided until late stage III. The non-operated children had been treated symptomatically by conservative methods. At the time of healing, 62.5% of the operated group had spherical
We reviewed the medical records of 115 patients with 130 hips with developmental dysplasia with complete dislocation in the absence of a neuromuscular disorder, spontaneous reduction with a Pavlik harness, and a minimum of 14 years’ follow-up. The mean age at the time of harness application was 4.8 months (1 to 12) and the mean time spent in the harness was 6.1 months (3 to 12). A total of 108 hips (83.1%) were treated with the harness alone and supplementary surgery for residual acetabular dysplasia, as defined by an acetabular index >
30°, was performed in 22 hips (16.9%). An overall satisfactory outcome (Severin grade I or II) was achieved in 119 hips (91.5%) at a mean follow-up of 16 years (14 to 32) with a follow-up rate of 75%. Avascular necrosis of the
Deep gluteal syndrome is an increasingly recognized disease entity, caused by compression of the sciatic or pudendal nerve due to non-discogenic pelvic lesions. It includes the piriformis syndrome, the gemelli-obturator internus syndrome, the ischiofemoral impingement syndrome, and the proximal hamstring syndrome. The concept of the deep gluteal syndrome extends our understanding of posterior hip pain due to nerve entrapment beyond the traditional model of the piriformis syndrome. Nevertheless, there has been terminological confusion and the deep gluteal syndrome has often been undiagnosed or mistaken for other conditions. Careful history-taking, a physical examination including provocation tests, an electrodiagnostic study, and imaging are necessary for an accurate diagnosis. After excluding spinal lesions, MRI scans of the pelvis are helpful in diagnosing deep gluteal syndrome and identifying pathological conditions entrapping the nerves. It can be conservatively treated with multidisciplinary treatment including rest, the avoidance of provoking activities, medication, injections, and physiotherapy. Endoscopic or open surgical decompression is recommended in patients with persistent or recurrent symptoms after conservative treatment or in those who may have masses compressing the sciatic nerve. Many physicians remain unfamiliar with this syndrome and there is a lack of relevant literature. This comprehensive review aims to provide the latest information about the epidemiology, aetiology, pathology, clinical features, diagnosis, and treatment. Cite this article:
1. Perthes' disease is an ischaemic lesion of the ossific nucleus of the head of the femur which may vary both in extent and degree. It is probably never quite complete. 2. When part of the ossific nucleus only is affected, as is usually the case, it is almost invariably the antero-lateral part. 3. The process of absorption of the damaged bone is complete radiologically before there is radiological evidence of reossification. 4. Reossification always occurs in Perthes' disease. 5. The aim of treatment must be to see that the mould in which the head is shaped is the right shape when ossification occurs. 6. The deformity of the head of the femur does not occur from pressure alone, but from pressure combined with subluxation. Full unrestricted weight-bearing can be allowed with safety on a
1. Thirty-seven specimens of the proximal third of the human femur were subjected to cyclically varying loads applied in a physiological direction to the
From 1982 to 1987, we randomised prospectively 413 patients requiring primary total hip replacements to receive either a Stanmore or Charnley prosthesis. They were reviewed by an independent observer in an attempt to correlate a number of factors including
The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check. Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).Aims
Materials and Methods
Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.Aims
Methods
We report the findings from independent prospective clinical and laboratory-based joint-simulator studies of the performance of ceramic