Between 1965 and 1973 a total of 808 McKee-Farrar metal-on-metal cemented total hip arthroplasties were performed in the Norfolk and Norwich Hospital. Of these, 230 surviving arthroplasties have been reviewed at average follow-up of 13.9 years. There were good or excellent results in 49% of the arthroplasties as judged by the Harris hip score with 78% of these having little or no pain. A comprehensive
Computerised tomography is useful in the diagnosis of abnormalities of the hip in children, particularly in assessing the size and shape of the acetabulum, the position and congruity of the femoral head relative to the acetabulum, and the degree of femoral anteversion or retroversion. It is most useful when limited hip movement and previous operations preclude adequate clinical examination and assessment by routine
We describe six knees in five patients, referred to us after accidental irrigation with chlorhexidine 1% in aqueous solution during arthroscopy. All six knees developed persisting pain, swelling and crepitus with loss of range of movement.
1. The authors have found epiphysial stapling a satisfactory and helpful procedure for correction of limb length discrepancy and recommend its use as described. 2. The use of a spring caliper for absolute
1. The true deformity of kyphoscoliosis has received little attention. Twenty-one deformities of congenital origin, ten idiopathic, and two secondary to neurofibromatosis, are discussed. The diagnosis is established and usually first suspected by
The early diagnosis of aseptic loosening of a total hip replacement by plain
We have reviewed the results of treating 75 fractures of the proximal femoral shaft in the presence of a cemented femoral prosthesis. A simple
Of 693 elderly patients admitted with suspected hip fractures, 43 had normal radiographs and were investigated by isotope bone scan. The 30 patients (70%) with normal scans were mobilised and none developed a fracture. All 13 of the patients with specific bone scan abnormalities were subsequently proved to have fractures, five of which became displaced. Clearly conventional
Unstable degenerative spondylolisthesis of the cervical spine is very rare. Slip usually occurs at the C3 on C4 or C4 on C5 levels, immediately above a stiff lower cervical spine. There are two clinical patterns: that with neurological involvement causing cervicobrachial pain or myelopathy and that with neck pain alone. The diagnosis can be made by flexion/extension
Congenital vertical talus was diagnosed in 15 feet of 10 children, and was treated by operative reduction. Forefoot deformity was corrected first, using anterolateral soft-tissue release on 11 feet, and manipulation alone in four feet. After prolonged immobilisation in plaster the affected feet had posterior release at the ankle and elongation of the calcaneal tendon. Clinical and
Following the resection of an extensive amount of bone in the
treatment of a tumour, the residual segment may be insufficient
to accept a standard length intramedullary cemented stem. Short-stemmed
endoprostheses conceivably have an increased risk of aseptic loosening.
Extra-cortical plates have been added to minimise this risk by supplementing
fixation. The aim of this study was to investigate the survivorship
of short-stemmed endoprostheses and extra-cortical plates. The study involved 37 patients who underwent limb salvage surgery
for a primary neoplasm of bone between 1998 and 2013. Endoprosthetic
replacement involved the proximal humerus in nine, the proximal
femur in nine, the distal femur in 13 and the proximal tibia in
six patients. There were 12 primary (32%) and 25 revision procedures (68%).
Implant survivorship was compared with matched controls. The amount
of bone that was resected was >
70% of its length and statistically
greater than the standard control group at each anatomical site.Aims
Patients and Methods
1. Sixteen patients with articular cartilage erosions after slight injury have been described, as have the results of their treatment. 2. The clinical features of this rarely diagnosed condition are discussed. Attention is drawn to "articular crepitus" and "synovial crepitus" as useful physical signs in establishing the diagnosis. 3. A
1. A child with so-called ischio-pubic osteochondritis is reported from whom the affected ramus was resected. The features observed in the resected specimen were those of a normal closing epiphysis. 2. The literature is reviewed with emphasis on other children who had biopsies and on large scale
1. In a survey of 107 cases of Erb's paralysis, twenty-seven instances of incipient or actual posterior dislocation of the upper end of the radius were discovered. 2. The type of case in which the dislocation occurs is defined and the early clinical and
We describe a method of closed, unlocked nailing for femoral fractures using ultrasound instead of an image intensifier.
Sixteen consecutive patients with tibial plateau fractures were investigated by standard
The familiar picture of spinal tuberculosis is one of destruction of adjacent vertebral bodies and of the intervening disc. There are, however, other patients without these
Five vertebrae with unilateral spondylolysis are presented. The associated asymmetry of the posterior elements supports the concept of a localised form of growth deficiency. The defect is difficult to demonstrate radiologically, and is perhaps present more frequently than is recognised. It should be suspected clinically from asymmetry of the neural arch and from unilateral wedging of the vertebral body, and may be demonstrated by further
Anterior subluxation of the cervical spine from flexion-rotational violence is often overlooked. Either
1. The