Advertisement for orthosearch.org.uk
Results 801 - 820 of 1437
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims

The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint.

Patients and Methods

We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93)


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 73 - 80
1 Jan 2018
Sanjuan-Cerveró R Carrera-Hueso FJ Vazquez-Ferreiro P Ramon-Barrios MA

Aims

The aim of this meta-analysis was to assess the safety and efficacy of collagenase clostridium histolyticum compared with fasciectomy and percutaneous needle fasciotomy (PNF) for Dupuytren’s disease.

Materials and Methods

We systematically searched PubMed, EMBASE, LILACS, Web of Science, Cochrane, Teseo and the ClinicalTrials.gov registry for clinical trials and cohort or case-control studies which compared the clinical outcomes and adverse effects of collagenase with those of fasciectomy or PNF.

Of 1345 articles retrieved, ten were selected. They described the outcomes of 425 patients treated with collagenase and 418 treated by fasciectomy or PNF. Complications were assessed using inverse-variance weighted odds ratios (ORs). Clinical efficacy was assessed by differences between the means for movement of the joint before and after treatment. Dose adjustment was applied in all cases.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 489 - 498
1 Aug 2017
Mifuji K Ishikawa M Kamei N Tanaka R Arita K Mizuno H Asahara T Adachi N Ochi M

Objectives

The objective of this study was to investigate the therapeutic effect of peripheral blood mononuclear cells (PBMNCs) treated with quality and quantity control culture (QQ-culture) to expand and fortify angiogenic cells on the acceleration of fracture healing.

Methods

Human PBMNCs were cultured for seven days with the QQ-culture method using a serum-free medium containing five specific cytokines and growth factors. The QQ-cultured PBMNCs (QQMNCs) obtained were counted and characterised by flow cytometry and real-time polymerase chain reaction (RT-PCR). Angiogenic and osteo-inductive potentials were evaluated using tube formation assays and co-culture with mesenchymal stem cells with osteo-inductive medium in vitro. In order to evaluate the therapeutic potential of QQMNCs, cells were transplanted into an immunodeficient rat femur nonunion model. The rats were randomised into three groups: control; PBMNCs; and QQMNCs. The fracture healing was evaluated radiographically and histologically.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 85 - 93
1 Jan 2018
Saleh A George J Faour M Klika AK Higuera CA

Objectives

The diagnosis of periprosthetic joint infection (PJI) is difficult and requires a battery of tests and clinical findings. The purpose of this review is to summarize all current evidence for common and new serum biomarkers utilized in the diagnosis of PJI.

Methods

We searched two literature databases, using terms that encompass all hip and knee arthroplasty procedures, as well as PJI and statistical terms reflecting diagnostic parameters. The findings are summarized as a narrative review.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1496 - 1501
1 Nov 2017
Bali N Aktselis I Ramasamy A Mitchell S Fenton P

Aims

There has been an evolution recently in the management of unstable fractures of the ankle with a trend towards direct fixation of a posterior malleolar fragment. Within these fractures, Haraguchi type 2 fractures extend medially and often cannot be fixed using a standard posterolateral approach. Our aim was to describe the posteromedial approach to address these fractures and to assess its efficacy and safety.

Patients and Methods

We performed a review of 15 patients with a Haraguchi type 2 posterior malleolar fracture which was fixed using a posteromedial approach. Five patients underwent initial temporary spanning external fixation. The outcome was assessed at a median follow-up of 29 months (interquartile range (IQR) 17 to 36) using the Olerud and Molander score and radiographs were assessed for the quality of the reduction.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1629 - 1636
1 Dec 2017
Sheth U Wasserstein D Jenkinson R Moineddin R Kreder H Jaglal S

Aims

To determine whether the findings from a landmark Canadian trial assessing the optimal management of acute rupture of the Achilles tendon influenced the practice patterns of orthopaedic surgeons in Ontario, Canada.

Materials and Methods

Health administrative databases were used to identify Ontario residents ≥ 18 years of age with an Achilles tendon rupture from April 2002 to March 2014. The rate of surgical repair (per 100 cases) was calculated for each calendar quarter. A time-series analysis was used to determine whether changes in the rate were chronologically related to the dissemination of results from a landmark trial published in February 2009. Non-linear spline regression was then used independently to identify critical time-points of change in the surgical repair rate to confirm the findings.


Bone & Joint Research
Vol. 6, Issue 7 | Pages 414 - 422
1 Jul 2017
Phetfong J Tawonsawatruk T Seenprachawong K Srisarin A Isarankura-Na-Ayudhya C Supokawej A

Objectives

Adipose-derived mesenchymal stem cells (ADMSCs) are a promising strategy for orthopaedic applications, particularly in bone repair. Ex vivo expansion of ADMSCs is required to obtain sufficient cell numbers. Xenogenic supplements should be avoided in order to minimise the risk of infections and immunological reactions. Human platelet lysate and human plasma may be an excellent material source for ADMSC expansion. In the present study, use of blood products after their recommended transfusion date to prepare human platelet lysate (HPL) and human plasma (Hplasma) was evaluated for in vitro culture expansion and osteogenesis of ADMSCs.

Methods

Human ADMSCs were cultured in medium supplemented with HPL, Hplasma and a combination of HPL and Hplasma (HPL+Hplasma). Characteristics of these ADMSCs, including osteogenesis, were evaluated in comparison with those cultured in fetal bovine serum (FBS).


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1571 - 1576
1 Dec 2017
Jacofsky DJ

‘Big data’ is a term for data sets that are so large or complex that traditional data processing applications are inadequate. Billions of dollars have been spent on attempts to build predictive tools from large sets of poorly controlled healthcare metadata. Companies often sell reports at a physician or facility level based on various flawed data sources, and comparative websites of ‘publicly reported data’ purport to educate the public. Physicians should be aware of concerns and pitfalls seen in such data definitions, data clarity, data relevance, data sources and data cleaning when evaluating analytic reports from metadata in health care.

Cite this article: Bone Joint J 2017;99-B:1571–6.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1561 - 1570
1 Dec 2017
Laumonerie P Reina N Kerezoudis P Declaux S Tibbo ME Bonnevialle N Mansat P

Aims

The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation.

Materials and Methods

Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 147 - 150
1 Feb 2017
Costa ML Tutton E Achten J Grant R Slowther AM

Traditionally, informed consent for clinical research involves the patient reading an approved Participant Information Sheet, considering the information presented and having as much time as they need to discuss the study information with their friends and relatives, their clinical care and the research teams. This system works well in the ‘planned’ or ‘elective’ setting. But what happens if the patient requires urgent treatment for an injury or emergency?

This article reviews the legal framework which governs informed consent in the emergency setting, discusses how the approach taken may vary according to the details of the emergency and the treatment required, and reports on the patients’ view of providing consent following a serious injury. We then provide some practical tips for managing the process of informed consent in the context of injuries and emergencies.

Cite this article: Bone Joint J 2017;99-B:147–150.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 46 - 57
1 Jan 2018
Zhou J Zhou XG Wang JW Zhou H Dong J

Objective

In the present study, we aimed to assess whether gelatin/β-tricalcium phosphate (β-TCP) composite porous scaffolds could be used as a local controlled release system for vancomycin. We also investigated the efficiency of the scaffolds in eliminating infections and repairing osteomyelitis defects in rabbits.

Methods

The gelatin scaffolds containing differing amounts of of β-TCP (0%, 10%, 30% and 50%) were prepared for controlled release of vancomycin and were labelled G-TCP0, G-TCP1, G-TCP3 and G-TCP5, respectively. The Kirby-Bauer method was used to examine the release profile. Chronic osteomyelitis models of rabbits were established. After thorough debridement, the osteomyelitis defects were implanted with the scaffolds. Radiographs and histological examinations were carried out to investigate the efficiency of eliminating infections and repairing bone defects.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 194 - 195
1 Apr 2017
Simpson AHRW Howie CR Norrie J


Bone & Joint 360
Vol. 6, Issue 5 | Pages 16 - 18
1 Oct 2017


Aims

The aim of this study was to examine the efficacy and safety of multiple boluses of intravenous (IV) tranexamic acid (TXA) on the hidden blood loss (HBL) and inflammatory response following primary total hip arthroplasty (THA).

Patients and Methods

A total of 150 patients were allocated randomly to receive a single bolus of 20 mg/kg IV TXA before the incision (group A), a single bolus followed by a second bolus of 1 g IV-TXA three hours later (group B) or a single bolus followed by two boluses of 1 g IV-TXA three and six hours later (group C). All patients were treated using a standard peri-operative enhanced recovery protocol. Primary outcomes were HBL and the level of haemoglobin (Hb) as well as the levels of C-reactive protein (CRP) and interleukin-6 (IL-6) as markers of inflammation. Secondary outcomes included the length of stay in hospital and the incidence of venous thromboembolism (VTE).


Bone & Joint Research
Vol. 6, Issue 4 | Pages 253 - 258
1 Apr 2017
Hsu C Lin C Jou I Wang P Lee J

Objectives

Osteoarthritis (OA) is the most common form of arthritis, affecting approximately 15% of the human population. Recently, increased concentration of nitric oxide in serum and synovial fluid in patients with OA has been observed. However, the exact role of nitric oxide in the initiation of OA has not been elucidated. The aim of the present study was to investigate the role of nitric oxide in innate immune regulation during OA initiation in rats.

Methods

Rat OA was induced by performing meniscectomy surgery while cartilage samples were collected 0, 7, and 14 days after surgery. Cartilage cytokine levels were determined by using enzyme-linked immunosorbent assay, while other proteins were assessed by using Western blot


Bone & Joint Research
Vol. 6, Issue 10 | Pages 602 - 609
1 Oct 2017
Jin A Cobb J Hansen U Bhattacharya R Reinhard C Vo N Atwood R Li J Karunaratne A Wiles C Abel R

Objectives

Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the mechanical strength of bone treated with BP (oral alendronate), and correlate data with the microarchitecture and density of microcracks in comparison with untreated controls.

Methods

Trabecular bone from hip fracture patients treated with BP (n = 10) was compared with naïve fractured (n = 14) and non-fractured controls (n = 6). Trabecular cores were synchrotron scanned and micro-CT scanned for microstructural analysis, including quantification of bone volume fraction, microarchitecture and microcracks. The specimens were then mechanically tested in compression.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1298 - 1303
1 Oct 2017
Schouten R Malone AA Frampton CM Tiffen C Hooper G

Aims

The primary aim of this independent prospective randomised trial was to compare serum metal ion levels for ceramic-on-metal (CoM) and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty (THA). Our one-year results demonstrated elevation in metal ion levels above baseline with no significant difference between the CoM and MoM groups. This paper reviews the five-year data.

Patients and Methods

The implants used in each patient differed only in respect to the type of femoral head (ceramic or metal). At five-year follow-up of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available for comparison.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1366 - 1372
1 Oct 2017
Rickert M Fleege C Tarhan T Schreiner S Makowski MR Rauschmann M Arabmotlagh M

Aims

We compared the clinical and radiological outcomes of using a polyetheretherketone cage with (TiPEEK) and without a titanium coating (PEEK) for instrumented transforaminal lumbar interbody fusion (TLIF).

Materials and Methods

We conducted a randomised clinical pilot trial of 40 patients who were scheduled to undergo a TLIF procedure at one or two levels between L2 and L5. The Oswestry disability index (ODI), EuroQoL-5D, and back and leg pain were determined pre-operatively, and at three, six, and 12 months post-operatively. Fusion rates were assessed by thin slice CT at three months and by functional radiography at 12 months.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1290 - 1297
1 Oct 2017
Devane PA Horne JG Foley G Stanley J

Aims

This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient’s bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA).

Materials and Methods

Models of the patient’s acetabular and femoral component obtained from the manufacturer and models of the patient’s pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1210 - 1215
1 Sep 2017
Parker MJ Cawley S

Aims

To compare the outcomes for trochanteric fractures treated with a sliding hip screw (SHS) or a cephalomedullary nail.

Patients and Methods

A total of 400 patients with a trochanteric hip fracture were randomised to receive a SHS or a cephalomedullary nail (Targon PFT). All surviving patients were followed up to one year from injury. Functional outcome was assessed by a research nurse blinded to the implant used.