Advertisement for orthosearch.org.uk
Results 801 - 820 of 1872
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 497 - 503
1 May 2002
Hedström M åström K Sjöberg H Dalén N Sjöberg K Brosjö E

A total of 63 women who had an operation for a fracture of the hip was randomly allocated to one year of treatment either with anabolic steroids, vitamin D and calcium (anabolic group) or with calcium only (control group). The thigh muscle volume was measured by quantitative CT. The bone mineral density of the hip, femur and tibia was assessed by quantitative CT and dual-energy x-ray absorptiometry and of the heel by quantitative ultrasound. Quantitative CT showed that the anabolic group did not lose muscle volume during the first 12 months whereas the control group did (p< 0.01). There was less bone loss in the proximal tibia in the anabolic group than in the control group. The speed of gait and the Harris hip score were significantly better in the anabolic group after six and 12 months. Anabolic steroids, even in this moderate dose, given in combination with vitamin D and calcium had a beneficial effect on muscle volume, bone mineral density and clinical function in this group of elderly women


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 407 - 411
1 May 1995
Court-Brown C Keating J Christie J McQueen M

Exchange nailing for failure of union after primary intramedullary nailing of the tibia is widely used but the indications and effectiveness have not been reported in detail. We have reviewed 33 cases of uninfected nonunion of the tibia treated by exchange nailing. This technique was successful without open bone grafting in all closed fractures and in open fractures of Gustilo types I, II and IIIa. The requirement for open bone grafting was reduced in type-IIIb fractures, but exchange nailing failed in type-IIIb fractures with significant bone loss. For these we recommend early open bone grafting. The most common complication was wound infection, seen more often than after primary nailing. We discuss our protocol for the use and timing of exchange nailing of all grades and types of tibial fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 777 - 783
1 Nov 1988
Karrholm J Selvik G Elmqvist L Hansson L Jonsson H

Using roentgen stereophotogrammetry we have recorded the three-dimensional movements of the knee during an anteroposterior laxity test in 36 patients with torn anterior cruciate ligaments and in three cadaver knees. At 30 degrees of knee flexion and before loads were applied the tibia occupied a more laterally rotated position if the anterior cruciate ligament had been injured. When the tibia was pulled anteriorly knees with cruciate deficiency rotated more laterally and were more abducted than normal knees. Posterior traction induced lateral rotation in the injured knee and medial rotation in the intact one. Precise knowledge of the three-dimensional instability of the anterior cruciate deficient knee may be important when the laxity is evaluated only in relation to one of the three cardinal axes


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 960 - 963
1 Nov 1994
Guzzanti V Falciglia F Gigante A Fabbriciani C

We performed intra-articular reconstruction of the anterior cruciate ligament (ACL) with the semitendinosus tendon placed in 2 mm diameter tunnels in 21 skeletally immature rabbits. The operation caused 11% damage to the physis of the femur on the frontal plane and 3% of its cross-sectional area but no alteration of growth or axial deviation of the bone resulted. In the tibia, the operation caused 12% damage to the physis in the frontal plane and 4% of the cross-sectional area. Two tibiae developed valgus deformities and one was shortened. Histological examination showed no areas of epiphysiodesis. There was no abnormality of growth-plate thickness in the two cases of tibia valga. Osseous metaplasia in the grafted tendons did not occur. The results suggest the need for careful evaluation of the percentage of damage to the growth plate before using intra-articular methods for reconstruction of the anterior cruciate ligament in adolescents


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 500 - 506
1 Aug 1965
Makin M

1. A survey of 112 cases of residual poliomyelitis with leg shortening of 2·5 centimetres or more is reported. 2. In eighty-seven patients paralysed in early infancy the fibular shortening was greater than the tibial shortening. 3. The absence of the normal "to and fro" motion of the fibula causes delay in the appearance of the fibular epiphyses and retards fibular development. 4. The shortening of the fibula in infancy causes deformity at the ankle, in the tibia itself and at the knee. 5. At the ankle the poorly developed lateral malleolus causes wedging of the lower tibial epiphysis and valgus at the ankle, which is often unstable. 6. At the knee progressive genu valgum is produced and in the tibia lateral torsion occurs. 7. The clinical significance of these deformities in relation to reconstructive procedures is stressed


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 560 - 565
1 Aug 1989
Cooke T Pichora D Siu D Scudamore R Bryant J

Some arthritic knees with varus deformity show excessive valgus angulation of the femoral joint surface with proximal tibia vara. This causes a downward and medial inclination of the articular surfaces in the coronal plane. The patients we studied had a medial shift of the standing load-bearing axis, and arthritic changes mainly in the medial compartment. Some also had lateral tibial subluxation with twisting of the distal femur and proximal tibia in opposite directions. We assessed the articular geometry by precise radiographic analysis, and compared the results with those in normal volunteers and a group of osteoarthritic patients. The prevalence of this type of deformity in our osteoarthritic patients was 11.5%; its recognition allows the use of specific operative correction that may include double osteotomy or the precise orientation of prosthetic components


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 239 - 243
1 May 1981
Young A Kinsella P Boland P

Thirteen patients suffering from rheumatoid arthritis had 19 stress fractures of the tibia or fibula. These patients characteristically presented with sudden, severe, unexplained pain with localised tenderness just below the knee or above the ankle. In seven patients examination of the adjacent joint indicated a flare-up of disease activity or a pyogenic arthritis. In six patients the diagnosis was delayed by the late appearance of callus in minute fractures. All patients had rheumatoid deformities of the ipsilateral lower limb: valgus deformities of the knee and subtalar joints occurred most frequently. All patients had osteoporosis; all except two had received steroid treatment and five had abnormalities of calcium metabolism. We suggest that deformities of the knee and ankle predispose patients with rheumatoid arthritis and osteoporosis to stress fractures of the tibia and fibula


Bone & Joint 360
Vol. 9, Issue 1 | Pages 42 - 44
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 117 - 121
1 Feb 1976
King K

An experimental model was designed to find a theoretical solution to the clinical problem of congenital tibial pseudarthrosis in children. The osteogenic properties of periosteum having been accepted, paired pedicled flaps of periosteum were raised from the subcutaneous surface of the tibia, tubed and anastomosed in a series of young dogs. In the last twenty-four consecutive cases the rate of complete ossification in these tubes rose to one in three. In the later stages of the work, in addition to the construction of periosteal tube grafts, pseudarthroses were induced in the middle third of each canine tibia in order to see if hypertrophy would occur under the stress of weight-bearing. It was found that in each of twenty-four specimens some hypertrophy occurred in the ossified periosteal tube grafts, and in three of the specimens this hypertrophy was associated with complete ossification of the graft that by-passed the pseudarthrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 984 - 988
1 Jul 2007
Omi H Kusumi T Kijima H Toh S

We investigated the effect of locally administered bisphosphonate on distraction osteogenesis in a rabbit model and evaluated its systemic effect. An osteotomy on the right tibia followed by distraction for four weeks was performed on 47 immature rabbits. They were divided into seven equal groups, with each group receiving a different treatment regime. Saline and three types of dosage of alendronate (low, 0.75 μg/kg; mid, 7.5 μg/kg and high 75 μg/kg) were given by systemic injection in four groups, and saline and two dosages (low and mild) were delivered by local injection to the distraction gap in the remaining three groups. The injections were performed five times weekly during the period of distraction. After nine weeks the animals were killed and image analysis and mechanical testing were performed on the distracted right tibiae and the left tibiae which served as a control group. The local low-dose alendronate group showed a mean increase in bone mineral density of 124.3 mg/cm. 3. over the local saline group (analysis of variance, p < 0.05) without any adverse effect on the left control tibiae. The findings indicate that the administration of local low-dose alendronate could be an effective pharmacological means of improving bone formation in distraction osteogenesis


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1534 - 1538
1 Nov 2007
Hammer TO Wieling R Green JM Südkamp NP Schneider E Müller CA

This study investigated the quality and quantity of healing of a bone defect following intramedullary reaming undertaken by two fundamentally different systems; conventional, using non-irrigated, multiple passes; or suction/irrigation, using one pass. The result of a measured re-implantation of the product of reaming was examined in one additional group. We used 24 Swiss mountain sheep with a mean tibial medullary canal diameter between 8 mm and 9 mm. An 8 mm ‘napkin ring’ defect was created at the mid-diaphysis. The wound was either surgically closed or occluded. The medullary cavity was then reamed to 11 mm. The Reamer/Irrigator/Aspirator (RIA) System was used for the reaming procedure in groups A (RIA and autofilling) and B (RIA, collected reamings filled up), whereas reaming in group C (Synream and autofilling) was performed with the Synream System. The defect was allowed to auto-fill with reamings in groups A and C, but in group B, the defect was surgically filled with collected reamings. The tibia was then stabilised with a solid locking Unreamed Humerus Nail (UHN), 9.5 mm in diameter. The animals were killed after six weeks. After the implants were removed, measurements were taken to assess the stiffness, strength and callus formation at the site of the defect. There was no significant difference between healing after conventional reaming or suction/irrigation reaming. A significant improvement in the quality of the callus was demonstrated by surgically placing captured reamings into the defect using a graft harvesting system attached to the aspirator device. This was confirmed by biomechanical testing of stiffness and strength. This study suggests it could be beneficial to fill cortical defects with reaming particles in clinical practice, if feasible


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1539 - 1544
1 Nov 2007
Hibino N Hamada Y Sairyo K Yukata K Sano T Yasui N

This study was undertaken to elucidate the mechanism of biological repair at the tendon-bone junction in a rat model. The stump of the toe flexor tendon was sutured to a drilled hole in the tibia (tendon suture group, n = 23) to investigate healing of the tendon-bone junction both radiologically and histologically. Radiological and histological findings were compared with those observed in a sham control group where the bone alone was drilled (n = 19). The biomechanical strength of the repaired junction was confirmed by pull-out testing six weeks after surgery in four rats in the tendon suture group. Callus formation was observed at the site of repair in the tendon suture group, whereas in the sham group callus formation was minimal. During the pull-out test, the repaired tendon-bone junction did not fail because the musculotendinous junction always disrupted first. In order to understand the factors that influenced callus formation at the site of repair, four further groups were evaluated. The nature of the sutured tendon itself was investigated by analysing healing of a tendon stump after necrosis had been induced with liquid nitrogen in 16 cases. A proximal suture group (n = 16) and a partial tenotomy group (n = 16) were prepared to investigate the effects of biomechanical loading on the site of repair. Finally, a group where the periosteum had been excised at the site of repair (n = 16) was examined to study the role of the periosteum. These four groups showed less callus formation radiologically and histologically than did the tendon suture group. In conclusion, the sutured tendon-bone junction healed and achieved mechanical strength at six weeks after suturing, showing good local callus formation. The viability of the tendon stump, mechanical loading and intact periosteum were all found to be important factors for better callus formation at a repaired tendon-bone junction


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 595 - 600
1 May 2000
Brooks RA Sharpe JR Wimhurst JA Myer BJ Dawes EN Rushton N

We used a rat model in vivo to study the effects of the concentration of polyethylene particles on the bone-implant interface around stable implants in the proximal tibia. Intra-articular injections of 10. 4. , 10. 6. or 10. 8. high-density polyethylene (HDPE) particles per joint were given 8, 10 and 12 weeks after surgery. The animals were killed after 14 and 26 weeks and the response at the interface determined. Fibrous tissue was seen at the bone-implant interface when the head of the implant was flush with the top of the tibia but not when it was sunk below the tibial plateau. In the latter case the implant was completely surrounded by a shell of bone. The area of fibrous tissue and that of the gap between the implant and bone was related to the concentration of particles in the 14-week group (p < 0.05). Foreign-body granulomas containing HDPE particles were seen at the bone-implant interface in animals given 10. 8. particles. The pathology resembles that seen around prostheses with aseptic loosening and we suggest that this is a useful model by which to study this process


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 695 - 701
1 Jun 2019
Yang H Wang S Lee K

Aims

The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon.

Patients and Methods

We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated.


Bone & Joint Research
Vol. 8, Issue 11 | Pages 509 - 517
1 Nov 2019
Kang K Koh Y Park K Choi C Jung M Shin J Kim S

Objectives

The aim of this study was to investigate the biomechanical effect of the anterolateral ligament (ALL), anterior cruciate ligament (ACL), or both ALL and ACL on kinematics under dynamic loading conditions using dynamic simulation subject-specific knee models.

Methods

Five subject-specific musculoskeletal models were validated with computationally predicted muscle activation, electromyography data, and previous experimental data to analyze effects of the ALL and ACL on knee kinematics under gait and squat loading conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 495 - 497
1 May 1993
Fraser R Menelaus M

We reviewed 20 patients with spina bifida who had had surgical management of tibial torsion. Eight had had bilateral procedures and 12 a unilateral procedure, giving a total of 28 limbs for analysis. We performed closed osteoclasis on seven limbs and tibial osteotomy on 21. In the closed osteoclasis group six limbs (85%) had a good result after an average follow-up of nine years (2 to 22). All limbs developed postoperative anteromedial bowing of the tibia which later remodelled. In the tibial osteotomy group 19 (90%) had a good result. The average follow-up was nine years (2 to 28). Complications occurred in seven limbs (33%). We recommend closed osteoclasis of the tibia for the young patient with spina bifida in whom walking is impeded by excessive internal tibial torsion, and supramalleolar tibial osteotomy in the older patient with excessive external tibial torsion and a planovalgus foot


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 400 - 404
1 Mar 2008
Johansson HR Skripitz R Aspenberg P

We have examined the deterioration of implant fixation after withdrawal of parathyroid hormone (PTH) in rats. First, the pull-out force for stainless-steel screws in the proximal tibia was measured at different times after withdrawal. The stimulatory effect of PTH on fixation was lost after 16 days. We then studied whether bisphosphonates could block this withdrawal effect. Mechanical and histomorphometric measurements were conducted for five weeks after implantation. Subcutaneous injections were given daily. Specimens treated with either PTH or saline during the first two weeks showed no difference in the mechanical or histological results (pull-out force 76 N vs 81 N; bone volume density 19% vs 20%). Treatment with PTH for two weeks followed by pamidronate almost doubled the pull-out force (152 N; p < 0.001) and the bone volume density (37%; ANOVA, p < 0.001). Pamidronate alone did not have this effect (89 N and 25%, respectively). Thus, the deterioration can be blocked by bisphosphonates. The clinical implications are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 3 | Pages 490 - 505
1 Aug 1948
Allan FG

1. Two inches of lengthening may be gained in the femur, and three inches in the tibia and fibula, without complication. 2. More than this may be secured at the risk of temporary external popliteal paresis. 3. Lengthening of the tibia and fibula is more certain and more easy to control than lengthening of the femur. 4. Traction, and counter-traction through the bone, with complete lateral rigidity, are essential to success. 5. In applying this technique to the femur there is a danger of knee stiffness. The farther from the knee the skeletal traction pins are inserted, the less is the risk. The operation should therefore be planned as high as possible in the shaft of the femur. 6. The most delicate structure, and the one least tolerant of stretching, is the external popliteal nerve. 7. An oblique osteotomy, started by closely spaced drill-holes, is the best. 8. Certain vascular complications experienced by other surgeons are attributable to subperiosteal bone exposure, and to dividing the periosteum and fascial structures transversely


Bone & Joint Research
Vol. 8, Issue 7 | Pages 304 - 312
1 Jul 2019
Nicholson JA Tsang STJ MacGillivray TJ Perks F Simpson AHRW

Objectives

The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management.

Methods

A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”.