Resection of malignant bony tumours of the pelvis
creates large bone and soft-tissue defects, and is frequently associated
with complications such as wound dehiscence and deep infection.
We present the results of six patients in whom a rectus abdominis
myocutaneous (RAM) flap was used following resection of a malignant
tumour of the pelvis. Bony reconstruction was performed using a
constrained hip tumour prosthesis in three patients, vascularised
fibular graft in two and frozen autograft in one. At a mean follow-up
of 63 months (16 to 115), no patients had a problem with the wound. Immediate reconstruction using a RAM flap may be used after resection
of a malignant tumour of the pelvis to provide an adequate volume
of tissue to eliminate the dead space, cover the exposed bone or
implants with well-vascularised soft tissue and to reduce the risk
of complications. Cite this article:
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.
The treatment of peri-prosthetic joint infection
(PJI) of the ankle is not standardised. It is not clear whether
an algorithm developed for hip and knee PJI can be used in the management
of PJI of the ankle. We evaluated the outcome, at two or more years
post-operatively, in 34 patients with PJI of the ankle, identified
from a cohort of 511 patients who had undergone total ankle replacement.
Their median age was 62.1 years (53.3 to 68.2), and 20 patients
were women. Infection was exogenous in 28 (82.4%) and haematogenous
in six (17.6%); 19 (55.9%) were acute infections and 15 (44.1%)
chronic. Staphylococci were the cause of 24 infections (70.6%).
Surgery with retention of one or both components was undertaken
in 21 patients (61.8%), both components were replaced in ten (29.4%),
and arthrodesis was undertaken in three (8.8%). An infection-free
outcome with satisfactory function of the ankle was obtained in
23 patients (67.6%). The best rate of cure followed the exchange
of both components (9/10, 90%). In the 21 patients in whom one or
both components were retained, four had a relapse of the same infecting organism
and three had an infection with another organism. Hence the rate
of cure was 66.7% (14 of 21). In these 21 patients, we compared
the treatment given to an algorithm developed for the treatment
of PJI of the knee and hip. In 17 (80.9%) patients, treatment was
not according to the algorithm. Most (11 of 17) had only one criterion against
retention of one or both components. In all, ten of 11 patients
with severe soft-tissue compromise as a single criterion had a relapse-free
survival. We propose that the treatment concept for PJI of the ankle
requires adaptation of the grading of quality of the soft tissues. Cite this article
Exsanguination is the second most common cause
of death in patients who suffer severe trauma. The management of
haemodynamically unstable high-energy pelvic injuries remains controversial,
as there are no universally accepted guidelines to direct surgeons
on the ideal use of pelvic packing or early angio-embolisation.
Additionally, the optimal resuscitation strategy, which prevents
or halts the progression of the trauma-induced coagulopathy, remains
unknown. Although early and aggressive use of blood products in
these patients appears to improve survival, over-enthusiastic resuscitative
measures may not be the safest strategy. This paper provides an overview of the classification of pelvic
injuries and the current evidence on best-practice management of
high-energy pelvic fractures, including resuscitation, transfusion
of blood components, monitoring of coagulopathy, and procedural
interventions including pre-peritoneal pelvic packing, external
fixation and angiographic embolisation. Cite this article:
The aim of this study was to evaluate the risk
factors for dislocation of the bearing after a mobile-bearing Oxford medial
unicompartmental knee replacement (UKR) and to test the hypothesis
that surgical factors, as measured from post-operative radiographs,
are associated with its dislocation From a total of 480 UKRs performed between 2001 and 2012, in
391 patients with a mean age of 66.5 years (45 to 82) (316 female,
75 male), we identified 17 UKRs where bearing dislocation occurred.
The post-operative radiological measurements of the 17 UKRs and
51 matched controls were analysed using conditional logistic regression analysis.
The post-operative radiological measurements included post-operative
change in limb alignment, the position of the femoral and tibial
components, the resection depth of the proximal tibia, and the femoral component-posterior
condyle classification. We concluded that a post-operative decrease in the posterior
tibial slope relative to the pre-operative value was the only significant
determinant of dislocation of the bearing after medial Oxford UKR
(odds ratio 1.881; 95% confidence interval 1.272 to 2.779). A post-operative
posterior tibial slope <
8.45° and a difference between the pre-operative
and post-operative posterior tibial slope of >
2.19° may increase
the risk of dislocation. Cite this article:
Between 2003 and 2007, 99 knees in 77 patients
underwent opening wedge high tibial osteotomy. We evaluated the effect
of initial stable fixation combined with an artificial bone substitute
on the mid- to long-term outcome after medial opening-wedge high
tibial osteotomy (HTO) for medial compartmental osteoarthritis or
spontaneous osteonecrosis of the knee in 78 knees in 64 patients
available for review at a minimum of five years (mean age 68 years;
49 to 82). The mean follow-up was 6.5 years (5 to 10). The mean
Knee Society knee score and function score improved from 49.6 ( Opening-wedge HTO using a stable plate fixation system combined
with a bone substitute is a reliable procedure that provides excellent
results. Although this treatment might seem challenging for older
patients, our results strongly suggest that the results are equally
good. Cite this article:
We report a case in which Ilizarov distraction osteogenesis was used to lengthen the portion of calcaneum that remained after a radical debridement for osteomyelitis. The patient was able to walk normally in unmodified shoes at the end of his treatment.
The purpose of this study was to assess whether
the use of a joint-sparing technique such as curettage and grafting was
successful in eradicating giant cell tumours of the proximal femur,
or whether an alternative strategy was more appropriate. Between 1974 and 2012, 24 patients with a giant cell tumour of
the proximal femur were treated primarily at our hospital. Treatment
was either joint sparing or joint replacing. Joint-sparing treatment
was undertaken in ten patients by curettage with or without adjunctive
bone graft. Joint replacement was by total hip replacement in nine patients
and endoprosthetic replacement in five. All 11 patients who presented
with a pathological fracture were treated by replacement. Local recurrence occurred in five patients (21%): two were treated
by hip replacement, three by curettage and none with an endoprosthesis.
Of the ten patients treated initially by curettage, six had a successful
outcome without local recurrence and required no further surgery.
Three eventually needed a hip replacement for local recurrence and
one an endoprosthetic replacement for mechanical failure. Thus 18
patients had the affected joint replaced and only six (25%) retained
their native joint. Overall, 60% of patients without a pathological
fracture who were treated with curettage had a successful outcome. Cite this article:
The peer review process for the evaluation of
manuscripts for publication needs to be better understood by the
orthopaedic community. Improving the degree of transparency surrounding
the review process and educating orthopaedic surgeons on how to
improve their manuscripts for submission will help improve both
the review procedure and resultant feedback, with an increase in
the quality of the subsequent publications. This article seeks to clarify
the peer review process and suggest simple ways in which the quality
of submissions can be improved to maximise publication success. Cite this article:
The April 2012 Children’s orthopaedics Roundup360 looks at osteonecrosis of the femoral head and surgery for dysplasia, femoral head blood flow during surgery, femoroacetabular impingement and sport in adolescence, the Drehmann sign, a predictive algorithm for septic arthritis, ACL reconstruction and arthrofibrosis in children, spinal cord monitoring for those less than four years old, arthroereisis for the flexible flat foot, fixing the displaced lateral humeral fracture, and mobile phones and inclinometer applications
There are few reports describing the technique
of managing acetabular protrusio in primary total hip replacement. Most
are small series with different methods of addressing the challenges
of significant medial and proximal migration of the joint centre,
deficient medial bone and reduced peripheral bony support to the
acetabular component. We describe our technique and the clinical
and radiological outcome of using impacted morsellised autograft
with a porous-coated cementless cup in 30 primary THRs with mild
(n = 8), moderate (n = 10) and severe (n = 12) grades of acetabular
protrusio. The mean Harris hip score had improved from 52 pre-operatively
to 85 at a mean follow-up of 4.2 years (2 to 10). At final follow-up,
27 hips (90%) had a good or excellent result, two (7%) had a fair
result and one (3%) had a poor result. All bone grafts had united
by the sixth post-operative month and none of the hips showed any
radiological evidence of recurrence of protrusio, osteolysis or
loosening. By using impacted morsellised autograft and cementless
acetabular components it was possible to achieve restoration of
hip mechanics, provide a biological solution to bone deficiency
and ensure long-term fixation without recurrence in arthritic hips
with protrusio undergoing THR. Cite this article:
This review considers the surgical treatment
of displaced fractures involving the knee in elderly, osteoporotic patients.
The goals of treatment include pain control, early mobilisation,
avoidance of complications and minimising the need for further surgery.
Open reduction and internal fixation (ORIF) frequently results in
loss of reduction, which can result in post-traumatic arthritis
and the occasional conversion to total knee replacement (TKR). TKR
after failed internal fixation is challenging, with modest functional
outcomes and high complication rates. TKR undertaken as treatment
of the initial fracture has better results to late TKR, but does
not match the outcome of primary TKR without complications. Given
the relatively infrequent need for late TKR following failed fixation,
ORIF is the preferred management for most cases. Early TKR can be
considered for those patients with pre-existing arthritis, bicondylar
femoral fractures, those who would be unable to comply with weight-bearing restrictions,
or where a single definitive procedure is required.
Pre-operative planning for total hip replacement
(THR) is challenging in hips with severe acetabular deformities, including
those with a hypoplastic acetabulum or severe defects and in the
presence of arthrodesis or ankylosis. We evaluated whether a Rapid
Prototype (RP) model, which is a life-sized reproduction based on
three-dimensional CT scans, can determine the feasibility of THR
and provide information about the size and position of the acetabular component
in severe acetabular deformities. THR was planned using an RP model
in 21 complex hips in five men (five hips) and 16 women (16 hips)
with a mean age of 47.7 years (24 to 70) at operation. An acetabular
component was implanted successfully and THR completed in all hips.
The acetabular component used was within 2 mm of the predicted size
in 17 hips (80.9%). All of the acetabular components and femoral
stems had radiological evidence of bone ingrowth and stability at
the final follow-up, without any detectable wear or peri-prosthetic
osteolysis. The RP model allowed a simulated procedure pre-operatively
and was helpful in determining the feasibility of THR pre-operatively,
and to decide on implant type, size and position in complex THRs. Cite this article:
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or re-displacement and five (4.5%) developed avascular
necrosis of the femoral head. Revision to an arthroplasty was required
for five patients (4.5%). A further six patients (5.4%) had elective
removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed
nonunion or re-displacement and 23 (11.1%) developed avascular necrosis.
A further four patients (1.9%) developed a secondary fracture around
the TFN. Revision to a hip replacement was required for 43 patients
(20.7%) patients and a further seven (3.3%) had elective removal
of the plate and screws. It is suggested that the stronger distal fixation combined with
rotational stability may lead to a reduced incidence of complications
related to the healing of the fracture when compared with other
contemporary fixation devices but this needs to be confirmed in
further studies. Cite this article:
We describe the results of 81 consecutive revision
total hip replacements with impaction grafting in 79 patients using
a collared polished chrome–cobalt stem, customised in length according
to the extent of distal bone loss. Our hypothesis was that the features
of this stem would reduce the rate of femoral fracture and subsidence
of the stem. The mean follow-up was 12 years (8 to 15). No intra-operative
fracture or significant subsidence occurred. Only one patient suffered
a post-operative diaphyseal fracture, which was associated with
a fall. All but one femur showed incorporation of the graft. No
revision for aseptic loosening was recorded. The rate of survival of the femoral component at 12 years, using
further femoral revision as the endpoint, was 100% (95% confidence
interval (CI) 95.9 to 100), and at nine years using re-operation
for any reason as the endpoint, was 94.6% (95% CI 92.0 to 97.2). These results suggest that a customised cemented polished stem
individually adapted to the extent of bone loss and with a collar
may reduce subsidence and the rate of fracture while maintaining
the durability of the fixation.
Endoprosthetic reconstruction following resection of 31 tumours of the proximal femur in 30 patients was performed using a Wagner SL femoral revision stem. The mean follow-up was 25.6 months (0.6 to 130.0). Of the 28 patients with a metastasis, 27 died within a mean follow-up period of 18.1 months (0.6 to 56.3) after the operation, and the remaining patient was excluded from the study 44.4 months post-operatively when the stem was removed. The two patients with primary bone tumours were still alive at the latest follow-up of 81.0 and 130.0 months, respectively. One stem only was removed for suspected low-grade infection 44.4 months post-operatively. The worst-case survival rate with removal of the stem for any cause and/or loss to follow-up was 80.0% (95% confidence interval 44.9 to 100) at 130.0 months. The mean Karnofsky index increased from 44.2% (20% to 70%) pre-operatively to 59.7% (0% to 100%) post-operatively, and the mean Merle d’Aubigné score improved from 4.5 (0 to 15) to 12.0 (0 to 18). The mean post-operative Musculoskeletal Tumour Society score was 62.4% (3.3% to 100%). The Wagner SL femoral revision stem offers an alternative to special tumour prostheses for the treatment of primary and secondary tumours of the proximal femur. The mid-term results are very promising, but long-term experience is necessary.
The current indications for functional restoration
of extension of the knee following quadriceps resection or loss require
reappraisal. The contribution of pedicled and free functional muscle
transfer is likely to be over-emphasised in many studies, with good
functional outcomes predominantly reported only in the context of
cases with residual quadriceps function. In cases with total quadriceps
resection or loss, all forms of reconstruction perform poorly. Furthermore,
in smaller resections with loss of two or fewer components of the
quadriceps, minimal impairment of function occurs in the absence
of functional reconstruction, suggesting that functional restoration
may not be warranted. Thus there is a paradox in the current approach
to quadriceps reconstruction, in that small resections are likely
to be over-treated and large resections remain under-treated. This review suggests a shift is required in the approach and
rationale for reconstructing functional extension of the knee after
quadriceps resection or loss. A classification based on current
evidence is suggested that emphasises more clearly the indications
and rationale for functional transfers.
Although gradual bone transport may permit the
restoration of large-diameter bones, complications are common owing
to the long duration of external fixation. In order to reduce such
complications, a new technique of bone transport involving the use
of an external fixator and a locking plate was devised for segmental
tibial bone defects. A total of ten patients (nine men, one woman) with a mean age
at operation of 40.4 years (16 to 64) underwent distraction osteogenesis
with a locking plate to treat previously infected post-traumatic
segmental tibial defects. The locking plate was fixed percutaneously
to bridge proximal and distal segments, and was followed by external fixation.
After docking, percutaneous screws were fixed at the transported
segment through plate holes. At the same time, bone grafting was
performed at the docking site with the external fixator removed. The mean defect size was 5.9 cm (3.8 to 9.3) and mean external
fixation index was
13.4 days/cm (11.8 to 19.5). In all cases, primary union of the
docking site and distraction callus was achieved, with an excellent
bony result. There was no recurrence of deep infection or osteomyelitis,
and with the exception of one patient with a pre-existing peroneal
nerve injury, all achieved an excellent or good functional result. With short external fixation times and low complication rates,
bone transport with a locking plate could be recommended for patients
with segmental tibial defects. Cite this article:
We have investigated the effectiveness of the transplantation of bone-marrow-derived mononuclear cells (BMMNCs) with interconnected porous calcium hydroxyapatite (IP-CHA) on early bone repair for osteonecrosis of the femoral head. We studied 22 patients (30 hips) who had osteonecrosis with a minimum follow-up of one year after implantation of BMMNCs. The mean age at surgery was 41 years (18 to 64) and the mean period of follow-up was 29 months (19 to 48). In a control group, cell-free IP-CHA was implanted into a further eight patients (9 hips) with osteonecrosis of the femoral head and the outcomes were compared. A reduction in the size of the osteonecrotic lesion was observed subsequent to hypertrophy of the bone in the transition zone in the BMMNC group. In three patients in the treatment group progression to extensive collapse was detected. In the control group subtle bone hypertrophy was observed, but severe collapse of the femoral head occurred in six of eight hips. In this limited study the implantation of BMMNCs and IP-CHA appears to confer benefit in the repair of osteonecrosis and in the prevention of collapse.