This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up.Aims
Patients and Methods
The aim of this study was to compare the outcomes of surgery
using growing rods in patients with severe A review of a multicentre EOS database identified 107 children
with severe EOS (major curve ≥ 90°) treated with growing rods before
the age of ten years with a minimum follow-up of two years and three
or more lengthening procedures. From the same database, 107 matched
controls with moderate EOS were identified.Aims
Patients and Methods
The aim of this study was to report the long-term outcome and
implant survival of the lateral resurfacing elbow (LRE) arthroplasty
in the treatment of elbow arthritis. We reviewed a consecutive series of 27 patients (30 elbows) who
underwent LRE arthroplasty between December 2005 and January 2008.
There were 15 women and 12 men, with a mean age of 61 years (25
to 82). The diagnosis was primary hypotrophic osteoarthritis (OA)
in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA)
in five (five elbows) and rheumatoid arthritis (RA) in ten patients
(11 elbows). The mean clinical outcome scores including the Mayo
Elbow Performance Score (MEPS), the American Shoulder and Elbow
Surgeons elbow score (ASES-e), the mean range of movement and the
radiological outcome were recorded at three, six and 12 months and
at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample Aim
Patients and Methods
The Corail stem has good long-term results. After four years
of using this stem, we have detected a small group of patients who
have presented with symptomatic metaphyseal debonding. The aim of
this study was to quantify the incidence of this complication, to
delineate the characteristics of patients presenting with this complication
and to compare these patients with asymptomatic controls to determine
any important predisposing factors. Of 855 Corail collarless cementless stems implanted for osteoarthritis,
18 presented with symptomatic metaphyseal debonding. A control group
of 74 randomly selected patients was assembled. Clinical and radiological
parameters were measured and a logistic regression model was created
to evaluate factors associated with metaphyseal debonding.Aims
Patients and Methods
The aim of this study was to investigate the impact of maturity status at the time of surgery on final spinal height in patients with an adolescent idiopathic scoliosis (AIS) using the spine-pelvic index (SPI). The SPI is a self-control ratio that is independent of age and maturity status. The study recruited 152 female patients with a Lenke 1 AIS. The additional inclusion criteria were a thoracic Cobb angle between 45° and 70°, Risser 0 to 1 or 3 to 4 at the time of surgery, and follow-up until 18 years of age or Risser stage 5. The patients were stratified into four groups: Risser 0 to 1 and selective fusion surgery (Group 1), Risser 0 to 1 and non-selective fusion (Group 2), Risser 3 to 4 and selective fusion surgery (Group 3), and Risser 3 to 4 and non-selective fusion (Group 4). The height of spine at follow-up (HOSf) and height of pelvis at follow-up (HOPf) were measured and the predicted HOS (pHOS) was calculated as 2.22 (SPI) × HOPf. One-way analysis of variance (ANOVA) was performed for statistical analysis.Aims
Patients and Methods
This retrospective study analyses the results of subtalar bone block distraction arthrodesis used in the treatment of late complications of calcaneal fractures, acute severely comminuted fractures, nonunion (and malunion) of attempted subtalar arthrodeses, avascular necrosis of the talus, and club-foot deformity. Of 39 patients (41 feet) who had this procedure, 35 (37 feet) returned for follow-up after a mean of 70 months (26 to 140). There were 24 men (25 feet) and 11 women (12 feet) with a mean age of 41 years (16 to 63). Each completed a standardised questionnaire, based on the hindfoot-scoring system of the American Orthopaedic Foot and Ankle Society and were reviewed both clinically and radiologically. Of the 37 operations, 32 (87%) achieved union. The mean hindfoot score (maximum of 94 points) increased from 21.1 points (8 to 46) preoperatively to 68.9 (14 to 82) at the final follow-up. The mean talocalcaneal and calcaneal pitch angles were 20.5° and 4.9° before operation, 25.9° and 8.3° immediately after, and 24.6° and 7.7° at the final follow-up, respectively. The mean talar declination angle improved from 6.5° (−10 to 22) before operation to 24.8° (14 to 32) at the final follow-up. The mean talocalcaneal height increased from 68.7 mm before operation to 74.5 mm immediately after and 73.5 mm at the final follow-up. Of the 37 arthrodeses available for review, 32 were successful; 29 patients (30 arthrodeses) were satisfied with the procedure. Minimal loss of hindfoot
The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI). Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society.Aims
Patients and Methods
The aim of this study was to evaluate the clinical and radiological
outcome of using an anatomical short-stem shoulder prosthesis to
treat primary osteoarthritis of the glenohumeral joint. A total of 66 patients (67 shoulders) with a mean age of 76 years
(63 to 92) were available for clinical and radiological follow-up
at two different timepoints (T1, mean 2.6 years, Aims
Patients and Methods
This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.Aims
Patients and Methods
The surgical treatment of tuberculosis (TB) of the spine consists
of debridement and reconstruction of the anterior column. Loss of
correction is the most significant challenge. Our aim was to report
the outcome of single-stage posterior surgery using bone allografts
in the management of this condition. The study involved 24 patients with thoracolumbar TB who underwent
single-stage posterior spinal surgery with a cortical bone allograft
for anterior column reconstruction and posterior instrumentation
between 2008 and 2015. A unilateral approach was used for 21 patients
with active TB, and a bilateral approach with decompression and closing-opening
wedge osteotomy was used for three patients with healed TB.Aims
Patients and Methods
The results and complications of 104 vascularised fibular grafts in 102 patients are presented. Bony union was ultimately achieved in 97 patients, with primary union in 84 (84%). The mean time to union was 15.5 weeks (8 to 40). In 13 patients, primary union was achieved at one end of the fibula and secondary union at the other end. In these patients, the mean time to union was 31.1 weeks (24 to 40). Five patients failed to achieve union, with a resultant pseudarthrosis (3 patients) or amputation (2 patients). There were various complications. Immediate thrombosis occurred in 14 cases. In two of 23 patients with osteomyelitis, infection recurred at two and six months after surgery, respectively. Both patients had active osteomyelitis less than one month before the operation. Bony infection occurred in a patient with a synovial sarcoma of the forearm one year after surgery. In 15 patients, 19 fractures of the fibular graft occurred after bony union, all except one within one year after union. In patients in whom an external fixator had been used, fracture occurred soon after its removal. Union was difficult to achieve in cases of congenital pseudarthrosis of the tibia. Appropriate
Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA. The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.Objectives
Methods
The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral locked plate and a six-pin monorail
fixator on its anteromedial surface. A corticotomy was performed
at the appropriate level. During the third stage, i.e. at the end
of the distraction phase, the transported fragment was aligned and
fixed to the plate with two to four screws. An iliac crest autograft
was added to the docking site and the fixator was removed. Functional
outcome was assessed using the Association for the Study and Application
of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes
were assessed using the Musculoskeletal Tumor Society (MSTS) score.Aims
Patients and Methods
The successful management of femoral neck fractures is obviously based upon many factors. The forces acting upon the proximal end of the femur are believed to be mainly compressive in nature, and the low-angle nail by stabilising the fully reduced fracture in the line of these forces is held to allow weight bearing to take place. Low-angle nailing is believed to offer many advantages over conventional methods of treatment but only in the presence of stability. Stable reduction is the essential preliminary to any form of treatment, and low-angle fixation with early weight bearing in the absence of stability is regarded as futile. It is suggested that those subcapital separations which follow trivial injury may originate as stress fractures accompanying the process of bone remodelling in the aged, and that many of these fractures may remain unrecognised and heal spontaneously. With rare exceptions, subcapital fractures are regarded as being of the same essential pattern, and their varying radiological appearance is considered to be due to the different degrees of displacement to which they have been subjected. A new classification based on this premise has been suggested. In a series of eighty subcapital fractures the incidence of avascular necrosis was not adversely affected by early weight bearing, but reduction in the extreme valgus position was invariably followed by this disaster. This is probably also true of any malposition in extreme rotation which must stretch and obliterate the vessels in the ligamentum teres. A rough
Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain. A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.Objectives
Methods