Advertisement for orthosearch.org.uk
Results 61 - 80 of 125
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 318 - 323
1 May 1968
May JMB Chacha PB

1. The radiological appearances of the fragments in 100 trochanteric fractures have been analysed. 2. A simple practical classification enables the correct method of reduction to be chosen. 3. In Type I fractures the proximal fragment consists of the head and neck alone. In Type II fractures the head, neck and a major part of the great trochanter constitute the proximal fragment. 4. The key role of the greater trochanter in influencing the displacement of the fragments is discussed. 5. For reduction, Type I fractures require rotation of the distal fragment to a neutral position. Type II fractures reduce in some degree of lateral rotation


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 2 | Pages 204 - 219
1 May 1949
Murray RC Frew JFM

1. A series of one hundred consecutive cases of trochanteric fractures treated conservatively by the authors has been reviewed. 2. Analysis of the results obtained and a study of the relevant literature has led us to the firm conclusion that the routine treatment of this group of fractures should be conservative. 3. Internal fixation should be reserved for those exceptional cases where traction is found to be inadequate: this is specially likely in cases associated with an upper motor neuron lesion, where difficulty is experienced in maintaining reduction owing to muscle spasm. 4. The basal type of fracture offers a special problem because it merges imperceptibly into that of the true transcervical fracture. No difficulty has been experienced in this series in the conservative treatment of such fractures, but we recognise that they might well be regarded as a variety of transcervical fracture and treated by nailing in order to avoid the risk of non-union


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1017 - 1026
1 Dec 2021
Sadiq S Lipski C Hanif U Arshad F Chaudary M Chaudhry F

Aims

This study assessed the impact of COVID-19 on hip and distal femur fracture patient outcomes across three successive UK lockdown periods over one year.

Methods

A single-centre retrospective cohort study was performed at an acute NHS Trust. Hip and distal femur fracture patients admitted within the first month from each of the three starting dates of each national lockdown were included and compared to a control group in March 2019. Data were collected as per the best practice tariff outcomes including additional outcomes as required. Data collection included COVID-19 status, time to theatre, 30-day mortality, presence of acute kidney injury (AKI) and pneumonia, and do not attempt cardiopulmonary resuscitation (DNACPR) status. Data were analyzed using an independent-samples t-test or chi-squared test with Fisher’s exact test where applicable. A p-value of < 0.05 was considered statistically significant.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article: Bone Joint Res 2013;2:206–9


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 3 - 8
1 Jul 2021
Roberts HJ Barry J Nguyen K Vail T Kandemir U Rogers S Ward D

Aims

While interdisciplinary protocols and expedited surgical treatment improve the management of hip fractures in the elderly, the impact of such interventions on patients specifically undergoing arthroplasty for a femoral neck fracture is not clear. We sought to evaluate the efficacy of an interdisciplinary protocol for the management of patients with a femoral neck fracture who are treated with an arthroplasty.

Methods

In 2017, our institution introduced a standardized interdisciplinary hip fracture protocol. We retrospectively reviewed adult patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for femoral neck fracture between July 2012 and March 2020, and compared patient characteristics and outcomes between those treated before and after the introduction of the protocol.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims

Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods.

Methods

Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 43 - 47
1 Apr 2021


Bone & Joint 360
Vol. 9, Issue 6 | Pages 15 - 18
1 Dec 2020


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 57 - 61
1 Jul 2020
Woolson ST

Aims

To establish whether there was a consensus among the members of the Hip Society (HS) on the role of direct anterior approach (DAA) contemporary primary total hip arthroplasty (THA).

Methods

An online survey was sent to all 112 active and senior members of the HS, to which 71 members responded. The survey was constructed to determine whether they believed that evidence-based medicine proves, in modern clinical practice, that the DAA has significant benefits compared to risks when contrasted with other approaches. In addition, they were asked if they currently used the DAA.


Bone & Joint 360
Vol. 9, Issue 3 | Pages 31 - 34
1 Jun 2020


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 191 - 197
1 Feb 2020
Gabor JA Padilla JA Feng JE Schnaser E Lutes WB Park KJ Incavo S Vigdorchik J Schwarzkopf R

Aims

Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications.

Methods

A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year).


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 11 - 16
1 Jan 2020
Parker MJ Cawley S

Aims

Debate continues about whether it is better to use a cemented or uncemented hemiarthroplasty to treat a displaced intracapsular fracture of the hip. The aim of this study was to attempt to resolve this issue for contemporary prostheses.

Methods

A total of 400 patients with a displaced intracapsular fracture of the hip were randomized to receive either a cemented polished tapered stem hemiarthroplasty or an uncemented Furlong hydroxyapatite-coated hemiarthroplasty. Follow-up was conducted by a nurse blinded to the implant at set intervals for up to one year from surgery.


Bone & Joint 360
Vol. 8, Issue 6 | Pages 12 - 15
1 Dec 2019


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 82 - 89
1 Jan 2020
Coenders MJ Mathijssen NMC Vehmeijer SBW

Aims

The aim of this study was to report our experience at 3.5 years with outpatient total hip arthroplasty (THA).

Methods

In this prospective cohort study, we included all patients who were planned to receive primary THA through the anterior approach between 1 April 2014 and 1 October 2017. Patient-related data and surgical information were recorded. Patient reported outcome measures (PROMs) related to the hip and an anchor question were taken preoperatively, at six weeks, three months, and one year after surgery. All complications, readmissions, and reoperations were registered.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1292 - 1299
1 Oct 2019
Masters J Metcalfe D Parsons NR Achten J Griffin XL Costa ML

Aims

This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review.

Patients and Methods

At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1093 - 1099
1 Sep 2019
Bradley KE Ryan SP Penrose CT Grant SA Wellman SS Attarian DE Green CL Risoli T Bolognesi MP

Aims

Antifibrinolytic agents, including tranexamic acid (TXA) and epsilon-aminocaproic acid (EACA), have been shown to be safe and effective for decreasing perioperative blood loss and transfusion following total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, there are few prospective studies that directly compare these agents. The purpose of this study was to compare the benefits of intraoperative intravenous TXA with EACA.

Patients and Methods

A total of 235 patients (90 THA and 145 TKA) were enrolled in this prospective, randomized controlled trial at a single tertiary-care referral centre. In the THA cohort, 53.3% of the patients were female with a median age of 59.8 years (interquartile range (IQR) 53.3 to 68.1). In the TKA cohort, 63.4% of the patients were female with a median age of 65.1 years (IQR 59.4 to 69.5). Patients received either TXA (n = 119) or EACA (n = 116) in two doses intraoperatively. The primary outcome measures included change in haemoglobin level and blood volume, postoperative drainage, and rate of transfusion. Secondary outcome measures included postoperative complications, cost, and length of stay (LOS).


Bone & Joint 360
Vol. 7, Issue 3 | Pages 10 - 12
1 Jun 2018


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Law GW Wong YR Yew AK Choh ACT Koh JSB Howe TS

Objectives

The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.

Methods

A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 793 - 799
1 Jul 2019
Ugland TO Haugeberg G Svenningsen S Ugland SH Berg ØH Pripp AH Nordsletten L

Aims

The aim of this randomized trial was to compare the functional outcome of two different surgical approaches to the hip in patients with a femoral neck fracture treated with a hemiarthroplasty.

Patients and Methods

A total of 150 patients who were treated between February 2014 and July 2017 were included. Patients were allocated to undergo hemiarthroplasty using either an anterolateral or a direct lateral approach, and were followed for 12 months. The mean age of the patients was 81 years (69 to 90), and 109 were women (73%). Functional outcome measures, assessed by a physiotherapist blinded to allocation, and patient-reported outcome measures (PROMs) were collected postoperatively at three and 12 months.