Advertisement for orthosearch.org.uk
Results 61 - 80 of 168
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 638 - 642
1 May 2008
Aderinto J Keating JF

We reviewed 27 diabetic patients who sustained a tibial fracture treated with a reamed intramedullary nail and compared them with a control group who did not have diabetes. There were 23 closed fractures and four were open. Union was delayed until after six months in 12 of the 23 (52%) diabetic patients with closed fractures and ten of the 23 (43%) control patients (p = 0.768). In two patients with diabetes (9%), closed tibial fractures failed to unite and required exchange nailing, whereas all closed fractures in the control group healed without further surgery (p = 0.489). In both the diabetic and control groups with closed fractures two patients (9%) developed superficial infections. There were two (9%) deep infections in diabetic patients with closed fractures, but none in the control group (p = 0.489). Overall, there was no significant difference in the rate of complications between the diabetic patients and the control group, but there was a tendency for more severe infections in patients with diabetes


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 248 - 249
1 May 1976
Stuart D

The localisation of acute haematogenous pyogenic osteomyelitis following a local injury is well known. Whilst there is often a history of trauma in patients developing bone and joint tuberculosis, its role is obscure. Two patients are reported who developed histologically proven tuberculosis in the vicinity of closed fractures during the healing process. These two patients make a total of four so far reported


Bone & Joint 360
Vol. 7, Issue 2 | Pages 30 - 33
1 Apr 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 722 - 723
1 Nov 1985
Garcia-Elias M Salo J

A patient with a fractured coracoid process in association with a dislocation of the shoulder is reported. The fracture was not recognised initially, and early mobilisation was encouraged; the widely separated fracture did not heal and a painful pseudarthrosis developed. We believe that this association may not be as rare as generally supposed, and emphasise the importance of careful clinical examination in patients with shoulder dislocation. If a coracoid fracture is suspected, lateral or oblique radiographs should be taken to confirm the diagnosis. A further radiograph after reduction is a useful precaution


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 822 - 829
1 Sep 1990
Mizuno K Mineo K Tachibana T Sumi M Matsubara T Hirohata K

We studied the precise role of the fracture haematoma in healing by the experimental transplantation of the haematoma at two days and four days after fracture of the rat femur to subperiosteal and intramuscular sites. We used bone marrow and peripheral blood haematomas for control experiments. The transplanted two-day fracture haematoma produced new bone by endochondral ossification at the subperiosteal site, but not at the intramuscular site. Four-day fracture haematoma produced new bone formation at both subperiosteal and intramuscular sites. These results suggest that fracture haematoma has an inherent osteogenetic potential


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 809 - 813
1 Jun 2005
Lemon M Somayaji HS Khaleel A Elliott DS

Fragility fractures of the ankle occur mainly in elderly osteoporotic women. They are inherently unstable and difficult to manage. There is a high incidence of complications with both non-operative and operative treatment. We treated 12 such fractures by closed reduction and stabilisation using a retrograde calcaneotalotibial expandable nail. The mean age of patients was 84 years (75 to 95). All were women and were able to walk fully weight-bearing after surgery. There were no wound complications. One patient died from a myocardial infarction 24 days after surgery. The 11 other patients were followed up for a mean of 67 weeks (39 to 104). All the fractures maintained satisfactory alignment and healed without delay. Six patients refused removal of the nail after union of the fracture. The functional rating using the scale of Olerud and Molander gave a mean score at follow-up of 61, compared with a pre-injury value of 70


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 722 - 725
1 Sep 1996
van der Schoot DKE Den Outer AJ Bode PJ Obermann WR van Vugt AB

We re-examined clinically and radiologically 88 patients with a fracture of the lower leg at a mean follow-up of 15 years. Forty-three fractures (49%) had healed with malalignment of at least 5°. More arthritis was found in the knee and ankle adjacent to the fracture than in the comparable joints of the uninjured leg. Malaligned fractures showed significantly more degenerative changes. Eighteen patients (20%) had symptoms in the fractured leg. There was a significant correlation between symptoms in the knee and arthritis but not between symptoms and ankle arthritis or malalignment. We conclude that fractures of the lower leg should be managed so that the possibility of angular deformity and thereby late arthritis is minimised


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 791 - 797
1 Sep 1998
Takahara M Sasaki I Kimura T Kato H Minami A Ogino T

Nine children sustained a second fracture of the distal humerus after union of an ipsilateral supracondylar fracture which had healed with cubitus varus. There were eight boys and one girl with a mean age of five years (1 to 8) at the time of the second fracture which occurred at a mean of 1.5 years after the first. In all patients, the second fracture was an epiphyseal injury of the distal humerus, either associated with a fracture of the lateral metaphysis below the site of the previous supracondylar fracture, or a fracture-separation of the entire distal humeral epiphysis. This suggests that the physis and epiphysis tend to be more subject to injury than the metaphysis of the distal humerus in children who have had a previous supracondylar fracture with varus malunion


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 536 - 541
1 May 2001
Stiefel D Meuli M Altermatt S

The treatment of fractures of the neck of the radius in children is difficult, particularly if the angulation of the fracture exceeds 60°. Since 1994 we have used closed reduction and stabilisation with an intramedullary Kirschner wire in patients with grade-IV fractures according to the classification of Judet et al. In a retrospective analysis of a two-year period (1994 to 1996), 324 children with fractures of the elbow were treated in our department. Of these, 29 (9%) had a fracture of the neck of the radius; six were grade-IV injuries (1.9%). Five of the latter had an excellent postoperative result with normal movement of the elbow and forearm. One patient with a poor result had a concomitant dislocation of the elbow. Our results suggest that closed reduction and intramedullary pinning of grade-IV fractures allows adequate stabilisation while healing occurs


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 654 - 659
1 Jul 1991
Kenwright J Richardson J Cunningham J White S Goodship A Adams M Magnussen P Newman J

Diaphyseal fractures of the tibia in 80 patients were treated by external skeletal fixation using a unilateral frame, either in a fixed mode or in a mode which allowed the application of a small amount of predominantly axial micromovement. Patients were allocated to each regime by random selection. Fracture healing was assessed clinically, radiologically and by measurement of the mechanical stiffness of the fracture. Both clinical and mechanical healing were enhanced in the group subjected to micromovement, compared to those treated with frames in a fixed mode possessing an overall stiffness similar to that of others in common clinical use. The differences in healing time were statistically significant and independently related to the treatment method. There was no difference in complication rates between treatment groups


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 137 - 140
1 Jan 1990
Lidor C Dekel S Meyer M Blaugrund E Hallel T Edelstein S

In vitamin D-fed chicks 1,25-dihydroxyvitamin D3 and 24,25-dihydroxyvitamin D3 were implanted into experimentally-produced fractures of the mid-tibia. The mechanical and biochemical properties of the tibia were evaluated for two weeks, including torsion tests, measurement of alkaline phosphatase activity, 45Ca incorporation, and Ca2+ content. Both dihydroxylated metabolites of vitamin D3 had a direct effect on endochondral bone formation. 24,25(OH)2D3 strengthened the callus, and raised alkaline phosphate activity in the first seven days after fracture. 1,25(OH)2D3 decreased the strength of the callus concomitant with a reduction in 45Ca incorporation. It is suggested that local application of 24,25(OH)2D3 into fractures may accelerate healing and prevent non-union


Bone & Joint 360
Vol. 7, Issue 5 | Pages 28 - 30
1 Oct 2018


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1385 - 1391
1 Oct 2018
Qvist AH Væsel MT Jensen CM Jensen SL

Aims

Recent studies of nonoperatively treated displaced midshaft clavicular fractures have shown a high incidence of nonunion and unsatisfactory functional outcome. Some studies have shown superior functional results and higher rates of healing following operative treatment. The aim of this study was to compare the outcome in these patients after nonoperative management with those treated with fixation.

Patients and Methods

In a multicentre, parallel randomized controlled trial, 146 adult patients with an acute displaced fracture of the midthird of the clavicle were randomized to either nonoperative treatment with a sling (71, 55 men and 16 women with a mean age of 39 years, 18 to 60) or fixation with a pre-contoured plate and locking screws (75, 64 men and 11 women with a mean age of 40 years, 18 to 60). Outcome was assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) Score, the Constant Score, and radiographical evidence of union. Patients were followed for one year.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 114 - 123
1 Jan 1984
Herbert T Fisher W

A new and simple operative technique has been developed to provide rigid internal fixation for all types of fractures of the scaphoid. This involves the use of a double-threaded bone screw which provides such good fixation that, after operation, a plaster cast is rarely required and most patients are able to return to work within a few weeks. A classification of scaphoid fractures is proposed. The indications for operation included not only acute unstable fractures, but also fractures with delayed healing and those with established non-union; screw fixation was combined with bone grafting to treat non-union. In a prospective trial, 158 operations using this technique were carried out between 1977 and 1981. The rate of union was 100 per cent for acute fractures and 83 per cent overall. This method of treatment appears to offer significant advantages over conventional techniques in the management of the fractured scaphoid


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 535 - 541
1 Apr 2018
Stevenson JD Doxey R Abudu A Parry M Evans S Peart F Jeys L

Aims

Preserving growth following limb-salvage surgery of the upper limb in children remains a challenge. Vascularized autografts may provide rapid biological incorporation with the potential for growth and longevity. In this study, we aimed to describe the outcomes following proximal humeral reconstruction with a vascularized fibular epiphyseal transfer in children with a primary sarcoma of bone. We also aimed to quantify the hypertrophy of the graft and the annual growth, and to determine the functional outcomes of the neoglenofibular joint.

Patients and Methods

We retrospectively analyzed 11 patients who underwent this procedure for a primary bone tumour of the proximal humerus between 2004 and 2015. Six had Ewing’s sarcoma and five had osteosarcoma. Their mean age at the time of surgery was five years (two to eight). The mean follow-up was 5.2 years (1 to 12.2).


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 538 - 545
1 Aug 1984
De Bastiani G Aldegheri R Renzi Brivio L

The results obtained with a lightweight dynamic axial fixator in the treatment of fractures are reported. The apparatus comprises a single bar with articulating ends which clamp self-tapping screws and can be locked at an angle appropriate for axial alignment. A telescopic facility allows ready conversion from rigid to dynamic fixation once periosteal callus formation has commenced. Reduction and controlled distraction or compression are achieved by means of a detachable compressor unit. We treated 288 patients with fresh fractures and 50 with ununited fractures. The success rate for fresh fractures was 94%, with average healing times ranging from 3.4 to 6.5 months. In ununited fractures also, the success rate was 94% with average healing times ranging from 4.7 to 6.5 months. Complications were minimal. The device is versatile and can be applied in an average of 15 minutes. It permits ambulatory fracture care without sacrificing a sound anatomical result


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 12 - 23
1 Feb 1981
Meggitt B Juett D Smith J

A study was made of the mechanics of blood-bearing in a series of patients treated with a cast-brace for fracture of the distal femur. Knee hinges incorporating strain-gauges, a simple force-plate on the floor and a standardised weight-bearing test were used to record axial loads through the cast-brace itself and through the fracture during the phases of healing. The cast-brace carried loads of only 10 to 20 per cent of body weight and functioned mainly as an antibuckling hinged tube. Patterns of weight-bearing recovery showed that the fracture itself limited loads to safe levels. A measure of the recovery of strength at the fracture was determined and termed the "fracture load index". Graphs obtained in this way demonstrated four biomechanical phases of bony union which correlated well with the stages of clinical healing. The clinical application of these results have led to improvements in the design of braces and the use of a cylinder cast-brace for fractures of the distal half of the femoral shaft and of a new type of brace with a hinge at the hip attached to the thigh cast for fractures of the proximal shaft. A simple clinical test is described by which it is possible to monitor the healing of fractures in cast-braces


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 369 - 376
1 May 1996
Weiler A Helling H Kirch U Zirbes TK Rehm KE

Foreign-body reaction to polyglycolide (PGA) implants has been described in man. Many animal experiments have verified the mechanical properties of fixation devices made from PGA, but a significant foreign-body reaction has not been described. We studied the effect of PGA rods in 12 sheep with standardized osteochondral fractures of the medial femoral condyle fixed with uncoloured, self-reinforced PGA rods (Biofix). Radiographs were taken at intervals ranging from two weeks to two years, and the sheep were killed at intervals ranging from six to 24 months. All knees were examined histologically. Eleven of the 12 fractures healed radiologically and histologically. Moderate to severe osteolysis was seen at four to six weeks with maximum changes at 12 weeks in ten animals. Six knees showed fistula-like connections between the implant site and the joint space. Three developed synovitis, one with inflammatory changes involving the whole cartilage and one with destruction of the medial condyle. Although in our study osteochondral fractures fixed with PGA rods healed reliably, there were frequent, significant foreign-body reactions. Caution is needed when considering the use of PGA fixation devices in vulnerable regions such as the knee


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 295 - 302
1 Mar 2017
Koh A Guerado E Giannoudis PV

Aims

Treatment guidelines for atypical femoral fractures associated with bisphosphonates have not been established. We conducted a systematic review of the treatment of atypical femoral fractures first, to evaluate the outcomes of surgical fixation of complete atypical fractures and secondly, to assess whether prophylactic surgery is necessary for incomplete atypical fractures.

Materials and Methods

Case reports and series were identified from the PubMed database and were included if they described the treatment of atypical femoral fractures. In total, 77 publications met our inclusion criteria and 733 patients with 834 atypical complete or incomplete femoral fractures were identified.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 15 - 18
1 Jan 2002
Whelan DB Bhandari M McKee MD Guyatt GH Kreder HJ Stephen D Schemitsch EH

The reliability of the radiological assessment of the healing of tibial fractures remains undetermined. We examined the inter- and intraobserver agreement of the healing of such fractures among four orthopaedic trauma surgeons who, on two separate occasions eight weeks apart, independently assessed the radiographs of 30 patients with fractures of the tibial shaft which had been treated by intramedullary fixation. The radiographs were selected from a database to represent fractures at various stages of healing. For each radiograph, the surgeon scored the degree of union, quantified the number of cortices bridged by callus or with a visible fracture line, described the extent and quality of the callus, and provided an overall rating of healing. The interobserver chance-corrected agreement using a quadratically weighted kappa (κ) statistic in which values of 0.61 to 0.80 represented substantial agreement were as follows: radiological union scale (κ = 0.60); number of cortices bridged by callus (κ = 0.75); number of cortices with a visible fracture line (κ = 0.70); the extent of the callus (κ = 0.57); and general impression of fracture healing (κ = 0.67). The intraobserver agreement of the overall impression of healing (κ = 0.89) and the number of cortices bridged by callus (κ = 0.82) or with a visible fracture line (κ = 0.83) was almost perfect. There are no validated scales which allow surgeons to grade fracture healing radiologically. Among those examined, the number of cortices bridged by bone appears to be a reliable, and easily measured radiological variable to assess the healing of fractures after intramedullary fixation