Advertisement for orthosearch.org.uk
Results 61 - 80 of 115
Results per page:
Bone & Joint 360
Vol. 5, Issue 4 | Pages 25 - 27
1 Aug 2016


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1165 - 1171
1 Sep 2013
Arastu MH Kokke MC Duffy PJ Korley REC Buckley RE

Coronal plane fractures of the posterior femoral condyle, also known as Hoffa fractures, are rare. Lateral fractures are three times more common than medial fractures, although the reason for this is not clear. The exact mechanism of injury is likely to be a vertical shear force on the posterior femoral condyle with varying degrees of knee flexion. These fractures are commonly associated with high-energy trauma and are a diagnostic and surgical challenge. Hoffa fractures are often associated with inter- or supracondylar distal femoral fractures and CT scans are useful in delineating the coronal shear component, which can easily be missed. There are few recommendations in the literature regarding the surgical approach and methods of fixation that may be used for this injury. Non-operative treatment has been associated with poor outcomes. The goals of treatment are anatomical reduction of the articular surface with rigid, stable fixation to allow early mobilisation in order to restore function. A surgical approach that allows access to the posterior aspect of the femoral condyle is described and the use of postero-anterior lag screws with or without an additional buttress plate for fixation of these difficult fractures.

Cite this article: Bone Joint J 2013;95-B:1165–71.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 812 - 817
1 Jun 2016
Verhage SM Boot F Schipper IB Hoogendoorn JM

Aims

Involvement of the posterior malleolus in fractures of the ankle probably adversely affects the functional outcome and may be associated with the development of post-traumatic osteoarthritis. Anatomical reduction is a predictor of a successful outcome.

The purpose of this study was to describe the technique and short-term outcome of patients with trimalleolar fractures, who were treated surgically using a posterolateral approach in our hospital between 2010 and 2014.

Patients and Methods

The study involved 52 patients. Their mean age was 49 years (22 to 79). There were 41 (79%) AO 44B-type and 11 (21%) 44C-type fractures. The mean size of the posterior fragment was 27% (10% to 52%) of the tibiotalar joint surface.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 767 - 771
1 Jun 2016
Konan S Duncan CP Masri BA Garbuz DS

Aims

Reconstruction of the acetabulum after failed total hip arthroplasty (THA) can be a surgical challenge in the presence of severe bone loss. We report the long-term survival of a porous tantalum revision acetabular component, its radiological appearance and quality of life outcomes.

Patients and Methods

We reviewed the results of 46 patients who had undergone revision of a failed acetabular component with a Paprosky II or III bone defect and reconstruction with a hemispherical, tantalum acetabular component, supplementary screws and a cemented polyethylene liner.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1106 - 1111
1 Aug 2016
Duckworth AD Jefferies JG Clement ND White TO

Aims

The aim of this study was to report the outcome following primary fixation or a staged protocol for type C fractures of the tibial plafond.

Patients and Methods

We studied all patients who sustained a complex intra-articular fracture (AO type C) of the distal tibia over an 11-year period. The primary short-term outcome was infection. The primary long-term outcome was the Foot and Ankle Outcome Score (FAOS).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1160 - 1169
1 Sep 2012
Bohm ER Tufescu TV Marsh JP

This review considers the surgical treatment of displaced fractures involving the knee in elderly, osteoporotic patients. The goals of treatment include pain control, early mobilisation, avoidance of complications and minimising the need for further surgery. Open reduction and internal fixation (ORIF) frequently results in loss of reduction, which can result in post-traumatic arthritis and the occasional conversion to total knee replacement (TKR). TKR after failed internal fixation is challenging, with modest functional outcomes and high complication rates. TKR undertaken as treatment of the initial fracture has better results to late TKR, but does not match the outcome of primary TKR without complications. Given the relatively infrequent need for late TKR following failed fixation, ORIF is the preferred management for most cases. Early TKR can be considered for those patients with pre-existing arthritis, bicondylar femoral fractures, those who would be unable to comply with weight-bearing restrictions, or where a single definitive procedure is required.


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 777 - 781
1 Jun 2013
Abolghasemian M Drexler M Abdelbary H Sayedi H Backstein D Kuzyk P Safir O Gross AE

In this retrospective study we evaluated the proficiency of shelf autograft in the restoration of bone stock as part of primary total hip replacement (THR) for hip dysplasia, and in the results of revision arthroplasty after failure of the primary arthroplasty. Of 146 dysplastic hips treated by THR and a shelf graft, 43 were revised at an average of 156 months, 34 of which were suitable for this study (seven hips were excluded because of insufficient bone-stock data and two hips were excluded because allograft was used in the primary THR). The acetabular bone stock of the hips was assessed during revision surgery. The mean implant–bone contact was 58% (50% to 70%) at primary THR and 78% (40% to 100%) at the time of the revision, which was a significant improvement (p < 0.001). At primary THR all hips had had a segmental acetabular defect > 30%, whereas only five (15%) had significant segmental bone defects requiring structural support at the time of revision. In 15 hips (44%) no bone graft or metal augments were used during revision.

A total of 30 hips were eligible for the survival study. At a mean follow-up of 103 months (27 to 228), two aseptic and two septic failures had occurred. Kaplan-Meier survival analysis of the revision procedures demonstrated a ten-year survival rate of 93.3% (95% confidence interval (CI) 78 to 107) with clinical or radiological failure as the endpoint. The mean Oxford hip score was 38.7 (26 to 46) for non-revised cases at final follow-up.

Our results indicate that the use of shelf autografts during THR for dysplastic hips restores bone stock, contributing to the favourable survival of the revision arthroplasty should the primary procedure fail.

Cite this article: Bone Joint J 2013;95-B:777–81.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 230 - 238
1 Feb 2013
Giannoudis PV Kanakaris NK Delli Sante E Morell DJ Stengel D Prevezas N

Over a five-year period, adult patients with marginal impaction of acetabular fractures were identified from a registry of patients who underwent acetabular reconstruction in two tertiary referral centres. Fractures were classified according to the system of Judet and Letournel. A topographic classification to describe the extent of articular impaction was used, dividing the joint surface into superior, middle and inferior thirds. Demographic information, hospitalisation and surgery-related complications, functional (EuroQol 5-D) and radiological outcome according to Matta’s criteria were recorded and analysed. In all, 60 patients (57 men, three women) with a mean age of 41 years (18 to 72) were available at a mean follow-up of 48 months (24 to 206). The quality of the reduction was ‘anatomical’ in 44 hips (73.3%) and ‘imperfect’ in 16 (26.7%). The originally achieved anatomical reduction was lost in12 patients (25.8%). Radiologically, 33 hips (55%) were graded as ‘excellent’, 11 (18.3%) as ‘good’, one (1.7%) as ‘fair’ and 15 (25%) as ‘poor’. A total of 11 further operations were required in 11 cases, of which six were total hip replacements.

Univariate linear regression analysis of the functional outcome showed that factors associated with worse pain were increasing age and an inferior location of the impaction. Elevation of the articular impaction leads to joint preservation with satisfactory overall medium-term functional results, but secondary collapse is likely to occur in some patients.

Cite this article: Bone Joint J 2013;95-B:230–8.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation.

Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures.

This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation.

Cite this article: Bone Joint J 2015;97-B:391–7.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 16 - 18
1 Oct 2014

The October 2014 Foot & Ankle Roundup360 looks at: multilayer compression bandaging superior for post-traumatic ankle oedema; compression stockings for ankle fractures; weight bearing ok in Achilles tendon ruptures; MRI findings can predict ankle sprain symptoms; salvage for malreduced ankle fractures; locking fibular plates are more expensive; is fixation better early or late in pilon fractures?; and calcaneal fracture fixation not for subtalar arthropathy


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1525 - 1529
1 Nov 2014
Thangarajah T Alexander S Bayley I Lambert SM

We report our experience with glenohumeral arthrodesis as a salvage procedure for epilepsy-related recurrent shoulder instability. A total of six patients with epilepsy underwent shoulder fusion for recurrent instability and were followed up for a mean of 39 months (12 to 79). The mean age at the time of surgery was 31 years (22 to 38). Arthrodesis was performed after a mean of four previous stabilisation attempts (0 to 11) in all but one patient in whom the procedure was used as a primary treatment. All patients achieved bony union, with a mean time to fusion of 2.8 months (2 to 7). There were no cases of re-dislocation. One revision was undertaken for loosening of the metalwork, and then healed satisfactorily. An increase was noted in the mean subjective shoulder value, which improved from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively although it decreased in two patients. The mean Oxford shoulder instability score improved from 13 pre-operatively (7 to 21) to 24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis eliminated recurrent instability and improved functional outcome. Fusion surgery should therefore be considered in this patient population. However, since the majority of patients are young and active, they should be comprehensively counselled pre-operatively given the functional deficit that results from the procedure.

Cite this article: Bone Joint J 2014;96-B:1525–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation.

In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group.

Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation.

The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used.

Cite this article: Bone Joint J 2015;97-B:398–404.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1272 - 1278
1 Oct 2006
Giannoudis PV Schneider E

Despite advances in the prevention and treatment of osteoporotic fractures, their prevalence continues to increase. Their operative treatment remains a challenge for the surgeon, often with unpredictable outcomes. This review highlights the current aspects of management of these fractures and focuses on advances in implant design and surgical technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 34 - 38
1 Jan 2011
Charity JAF Tsiridis E Sheeraz A Howell JR Hubble MJW Timperley AJ Gie GA

We evaluated all cases involving the combined use of a subtrochanteric derotational femoral shortening osteotomy with a cemented Exeter stem performed at our institution. With severe developmental dysplasia of the hip an osteotomy is often necessary to achieve shortening and derotation of the proximal femur. Reduction can be maintained with a 3.5 mm compression plate while the implant is cemented into place. Such a plate was used to stabilise the osteotomy in all cases. Intramedullary autograft helps to prevent cement interposition at the osteotomy site and promotes healing. There were 15 female patients (18 hips) with a mean age of 51 years (33 to 75) who had a Crowe IV dysplasia of the hip and were followed up for a mean of 114 months (52 to 168). None was lost to follow-up. All clinical scores were collected prospectively. The Charnley modification of the Merle D’Aubigné-Postel scores for pain, function and range of movement showed a statistically significant improvement from a mean of 2.4 (1 to 4), 2.3 (1 to 4), 3.4 (1 to 6) to 5.2 (3 to 6), 4.4 (3 to 6), 5.2 (4 to 6), respectively. Three acetabular revisions were required for aseptic loosening; one required femoral revision for access. One osteotomy failed to unite at 14 months and was revised successfully. No other case required a femoral revision. No postoperative sciatic nerve palsy was observed.

Cemented Exeter femoral components perform well in the treatment of Crowe IV dysplasia with this procedure.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 25 - 28
1 Oct 2014

The October 2014 Trauma Roundup360 looks at: proximal humeral fractures in children; quadrilateral surface plates in transverse acetabular fractures; sleep deprivation and poor outcomes in trauma; bipolar hemiarthroplasty; skeletal traction; forefoot fractures; telemedicine in trauma; ketamine infusion for orthopaedic injuries; and improved functional outcomes seen with trauma networks.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined.

The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded.

The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (sd 4.0) and 4.6 mm (sd 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (sd 4.6) and 6.4 mm (sd 4.6), respectively.

Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset.

Cite this article: Bone Joint J 2014;96-B:1274–81.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 319 - 324
1 Mar 2014
Abolghasemian M Sadeghi Naini M Tangsataporn S Lee P Backstein D Safir O Kuzyk P Gross AE

We retrospectively reviewed 44 consecutive patients (50 hips) who underwent acetabular re-revision after a failed previous revision that had been performed using structural or morcellised allograft bone, with a cage or ring for uncontained defects. Of the 50 previous revisions, 41 cages and nine rings were used with allografts for 14 minor-column and 36 major-column defects. We routinely assessed the size of the acetabular bone defect at the time of revision and re-revision surgery. This allowed us to assess whether host bone stock was restored. We also assessed the outcome of re-revision surgery in these circumstances by means of radiological characteristics, rates of failure and modes of failure. We subsequently investigated the factors that may affect the potential for the restoration of bone stock and the durability of the re-revision reconstruction using multivariate analysis.

At the time of re-revision, there were ten host acetabula with no significant defects, 14 with contained defects, nine with minor-column, seven with major-column defects and ten with pelvic discontinuity. When bone defects at re-revision were compared with those at the previous revision, there was restoration of bone stock in 31 hips, deterioration of bone stock in nine and remained unchanged in ten. This was a significant improvement (p <  0.001). Morselised allografting at the index revision was not associated with the restoration of bone stock.

In 17 hips (34%), re-revision was possible using a simple acetabular component without allograft, augments, rings or cages. There were 47 patients with a mean follow-up of 70 months (6 to 146) available for survival analysis. Within this group, the successful cases had a minimum follow-up of two years after re-revision. There were 22 clinical or radiological failures (46.7%), 18 of which were due to aseptic loosening. The five and ten year Kaplan–Meier survival rate was 75% (95% CI, 60 to 86) and 56% (95% CI, 40 to 70) respectively with aseptic loosening as the endpoint. The rate of aseptic loosening was higher for hips with pelvic discontinuity (p = 0.049) and less when the allograft had been in place for longer periods (p = 0.040).

The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent re-revision surgery to a certain extent.

Cite this article: Bone Joint J 2014;96-B:319–24.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 37 - 40
1 Nov 2013
Mullaji AB Shetty GM

There are few reports describing the technique of managing acetabular protrusio in primary total hip replacement. Most are small series with different methods of addressing the challenges of significant medial and proximal migration of the joint centre, deficient medial bone and reduced peripheral bony support to the acetabular component. We describe our technique and the clinical and radiological outcome of using impacted morsellised autograft with a porous-coated cementless cup in 30 primary THRs with mild (n = 8), moderate (n = 10) and severe (n = 12) grades of acetabular protrusio. The mean Harris hip score had improved from 52 pre-operatively to 85 at a mean follow-up of 4.2 years (2 to 10). At final follow-up, 27 hips (90%) had a good or excellent result, two (7%) had a fair result and one (3%) had a poor result. All bone grafts had united by the sixth post-operative month and none of the hips showed any radiological evidence of recurrence of protrusio, osteolysis or loosening. By using impacted morsellised autograft and cementless acetabular components it was possible to achieve restoration of hip mechanics, provide a biological solution to bone deficiency and ensure long-term fixation without recurrence in arthritic hips with protrusio undergoing THR.

Cite this article: Bone Joint J 2013;95-B, Supple A:37–40.