Advertisement for orthosearch.org.uk
Results 61 - 80 of 85
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1597 - 1601
1 Dec 2008
Thompson NW Kapoor A Thomas J Hayton MJ

We describe the use of a vascularised periosteal patch onlay graft based on the 1,2 intercompartmental supraretinacular artery in the management of 11 patients (ten men, one woman) with chronic nonunion involving the proximal third of the scaphoid. The mean age of the patients was 31 years (21 to 45) with the dominant hand affected in eight. Six of the patients were smokers and three had undergone previous surgery to the scaphoid. All of the proximal fragments were avascular. The presence of union was assessed using longitudinal axis CT.

Only three patients progressed to union of the scaphoid and four required a salvage operation for a symptomatic nonunion. The remaining four patients with a persistent nonunion are asymptomatic with low pain scores, good grip strength and a functional range of wrist movement.

Although this technique has potential technical advantages over vascularised pedicled bone grafting, the rate of union has been disappointing and we do not recommend it as a method of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1257 - 1262
1 Sep 2009
Sundar S Pendegrass CJ Oddy MJ Blunn GW

We used demineralised bone matrix (DBM) to augment re-attachment of tendon to a metal prosthesis in an in vivo ovine model of reconstruction of the extensor mechanism at the knee. We hypothesised that augmentation of the tendon-implant interface with DBM would enhance the functional and histological outcomes as compared with previously reported control reconstructions without DBM. Function was assessed at six and 12 weeks postoperatively, and histological examination was undertaken at 12 weeks.

A significant increase of 23.5% was observed in functional weight-bearing at six weeks in the DBM-augmented group compared with non-augmented controls (p = 0.004). By 12 weeks augmentation with DBM resulted in regeneration of a more direct-type enthesis, with regions of fibrocartilage, mineralised fibrocartilage and bone. In the controls the interface was predominantly indirect, with the tendon attached to the bone graft-hydroxyapatite base plate by perforating collagen fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 373 - 377
1 Mar 2012
Hu MW Liu ZL Zhou Y Shu Y L. Chen C Yuan X

Posterior lumbar interbody fusion (PLIF) is indicated for many patients with pain and/or instability of the lumbar spine. We performed 36 PLIF procedures using the patient’s lumbar spinous process and laminae, which were inserted as a bone graft between two vertebral bodies without using a cage. The mean lumbar lordosis and mean disc height to vertebral body ratio were restored and preserved after surgery. There were no serious complications.

These results suggest that this procedure is safe and effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 190 - 193
1 Feb 2012
Koh Y Moon H Kim Y Park Y Jo S Kwon S

We compared extrusion of the allograft after medial and lateral meniscal allograft transplantation and examined the correlation between the extent of extrusion and the clinical outcome. A total of 73 lateral and 26 medial meniscus allografts were evaluated by MRI at a mean of 32 months (24 to 59) in 99 patients (67 men, 32 women) with a mean age of 35 years (21 to 52). The absolute values and the proportional widths of extruded menisci as a percentage were measured in coronal images that showed maximum extrusion. Functional assessments were performed using Lysholm scores. The mean extrusion was 4.7 mm (1.8 to 7.7) for lateral menisci and 2.9 mm (1.2 to 6.5) for medial menisci (p < 0.001), and the mean percentage extrusions were 52.0% (23.8% to 81.8%) and 31.2% (11.6% to 63.4%), respectively (p < 0.001). Mean Lysholm scores increased significantly from 49.0 (10 to 83) pre-operatively to 86.6 (33 to 99) at final follow-up for lateral menisci (p = 0.001) and from 50.9 (15 to 88) to 88.3 (32 to 100) for medial menisci (p < 0.001). The final mean Lysholm scores were similar in the two groups (p = 0.312). Furthermore, Lysholm scores were not found to be correlated with degree of extrusion (p = 0.242).

Thus, transplanted lateral menisci extrude more significantly than transplanted medial menisci. However, the clinical outcome after meniscal transplantation was not found to be adversely affected by extrusion of the allograft.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1096 - 1101
1 Aug 2005
Maynou C Cassagnaud X Mestdagh H

We compared the long-term function of subscapularis after the Latarjet procedure using two surgical approaches. We treated 102 patients (106 shoulders) with a mean age of 26.8 years (15 to 51) with involuntary unidirectional recurrent instability. The operation was carried out through an L-shaped incision with trans-section of the upper two-thirds of the muscle in 69 cases and with a subscapularis split in 37. All clinical results were assessed by the Rowe and the Duplay scores and the function of subscapularis by evaluating the distance and strength at the lift-off position. Bilateral CT was performed in 77 patients for assessment of fatty degeneration. The mean follow-up was 7.5 years (2 to 15) and 18% of cases were lost to follow-up. The mean Duplay score was 82 of 100 for the L-shaped incision group and 90 of 100 for those with a subscapularis split (p = 0.02). The mean fatty degeneration score was 1.18 after an L-shaped incision compared with 0.12 after subscapularis split (p = 0.001). The subscapularis split approach is therefore recommended.


Bone & Joint Research
Vol. 1, Issue 4 | Pages 50 - 55
1 Apr 2012
O’Neill F Condon F McGloughlin T Lenehan B Coffey C Walsh M

Introduction

The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the synthetic material could produce results similar to those of the osteoporotic bone, it could reduce or eliminate the need for testing of implants on bone.

Methods

Pushout studies were performed with the dynamic hip screw (DHS) and the DHS Blade in both cadaveric femoral heads and artificial bone substitutes in the form of polyurethane foam blocks of different density. The pushout studies were performed as a means of comparing the force displacement curves produced by each implant within each material.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 222 - 226
1 Feb 2012
Rodrigues-Pinto R Freitas D Costa LD Sousa R Trigueiros M Lemos R Silva C Oliveira A

Radial osteotomy is currently advocated for patients with Lichtman’s stages II and IIIA of Kienböck’s disease; its place in the treatment of patients with stage IIIB disease remains controversial. The purpose of this study was to evaluate the medium-term results of this procedure and to compare the outcome in patients with stage IIIB disease and those with earlier stages (II and IIIA). A total of 18 patients (18 osteotomies) were evaluated both clinically and radiologically at a mean follow-up of 10.3 years (4 to 18). Range of movement, grip strength and pain improved significantly in all patients; the functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability (Disabilities of Arm, Shoulder and Hand questionnaire) was low at the final follow-up in all patients evaluated. Patients with stage IIIB disease, however, had a significantly lower grip strength, lower NSSK scores and higher disability than those in less advanced stages. Radiological progression of the disease was not noted in either group, despite the stage. Radial osteotomy seems effective in halting the progression of disease and improving symptoms in stages II, IIIA and IIIB. Patients with less advanced disease should be expected to have better clinical results.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1336 - 1340
1 Oct 2006
Aoki Y Yasuda K Mikami S Ohmoto H Majima T Minami A

We compared the results ten years after an inverted V-shaped high tibial osteotomy with those of a historical series of conventional closing-wedge osteotomies. The closing-wedge series consisted of 56 knees in 51 patients with a mean follow-up of 11 years (10 to 15). The inverted V-shaped osteotomy was evaluated in 48 knees in 43 patients at a mean follow-up of 14 years (10 to 19). All the patients were scored using the Japanese Orthopaedic Association rating scale for osteoarthritis of the knee and radiological assessment.

The pre-operative grade of osteoarthritis was similar in both groups. Post-operatively, the knee function score was graded as satisfactory in 63% (35) of the closing-wedge group but in 89% (43) of the inverted V-shaped osteotomy group. Post-operative radiological examination showed that delayed union and loss of correction occurred more often after a closing-wedge osteotomy than after an inverted V-shaped procedure.

Our study suggests that the inverted V-shaped osteotomy may offer more dependable long-term results than traditional closing-wedge osteotomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1245 - 1251
1 Sep 2006
Pendegrass CJ Oddy MJ Sundar S Cannon SR Goodship AE Blunn GW

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure.

Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 213 - 219
1 Feb 2006
Kambhampati SBS Birch R Cobiella C Chen L

We describe the results of surgical treatment in a prospective study of 183 consecutive cases of subluxation (101) and dislocation (82) of the shoulder secondary to obstetric brachial plexus palsy between 1995 and 2000. Neurological recovery was rated ‘good’ or ‘useful’ in all children, whose lesions fell into groups 1, 2 or 3 of the Narakas classification. The mean age at operation was 47 months (3 to 204). The mean follow-up was 40 months (24 to 124).

The mean gain in function was 3.6 levels (9.4 to 13) using the Mallet score and 2 (2.1 to 4.1) on the Gilbert score. The mean active global range of shoulder movement was increased by 73°; the mean range of active lateral rotation by 58° and that of supination of the forearm by 51°. Active medial rotation was decreased by a mean of 10°. There were 20 failures. The functional outcome is related to the severity of the neurological lesion, the duration of the dislocation and onset of deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 941 - 948
1 Jul 2010
Stone KR Adelson WS Pelsis JR Walgenbach AW Turek TJ

We describe 119 meniscal allograft transplantations performed concurrently with articular cartilage repair in 115 patients with severe articular cartilage damage. In all, 53 (46.1%) of the patients were over the age of 50 at the time of surgery. The mean follow-up was for 5.8 years (2 months to 12.3 years), with 25 procedures (20.1%) failing at a mean of 4.6 years (2 months to 10.4 years). Of these, 18 progressed to knee replacement at a mean of 5.1 years (1.3 to 10.4). The Kaplan-Meier estimated mean survival time for the whole series was 9.9 years (sd 0.4). Cox’s proportional hazards model was used to assess the effect of covariates on survival, with age at the time of surgery (p = 0.026) and number of previous operations (p = 0.006) found to be significant.

The survival of the transplant was not affected by gender, the severity of cartilage damage, axial alignment, the degree of narrowing of the joint space or medial versus lateral allograft transplantation. Patients experienced significant improvements at all periods of follow-up in subjective outcome measures of pain, activity and function (all p-values < 0.05), with the exception of the seven-year Tegner index score (p = 0.076).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 447 - 450
1 Apr 2009
Wroblewski BM Siney PD Fleming PA

Of the 11 054 Charnley low-frictional torque arthroplasties carried out at our hospital between 1962 and 1977, 110 (94 patients) had a minimum follow-up of 30 years with a mean of 32.3 years (30.0 to 40.5). The mean age of the patients at operation was 43.3 years (17.0 to 65.0) and 75.7 years (51.0 to 97.0) at follow-up. Overall, 90% of hips (99) were free from pain and activity was reported as normal in 58% of the patients.

A total of 13 hips (11.8%) were revised at a mean follow-up of 32.3 years (30.0 to 39.5), with wear and loosening of the acetabular component as the main indications.

The clinical results did not reflect the mechanical state of the implant. Follow-up with sequential radiographs of good quality is essential. Revision for radiological changes alone must be accepted if gross loss of bone stock is to be avoided.

Improvements in the design, materials and operative technique, based on the long-term outcome, are highlighted.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 304 - 309
1 Mar 2009
Kerboull L Hamadouche M Kerboull M

We describe 129 consecutive revision total hip replacements using a Charnley-Kerboull femoral component of standard length with impaction allografting. The mean follow-up was 8.2 years (2 to 16). Additionally, extramedullary reinforcement was performed using struts of cortical allograft in 49 hips and cerclage wires in 30.

There was one intra-operative fracture of the femur but none later. Two femoral components subsided by 5 mm and 8 mm respectively, and were considered to be radiological failures. No further revision of a femoral component was required. The rate of survival of the femoral component at nine years, using radiological failure as the endpoint, was 98%. Our study showed that impaction grafting in association with a Charnley-Kerboull femoral component has a low rate of subsidence. Reconstruction of deficiencies of distal bone with struts of cortical allograft appeared to be an efficient way of preventing postoperative femoral fracture for up to 16 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1382 - 1386
1 Oct 2007
Bajada S Harrison PE Ashton BA Cassar-Pullicino VN Ashammakhi N Richardson JB

Successful healing of a nine-year tibial nonunion resistant to six previous surgical procedures was achieved by tissue engineering. We used autologous bone marrow stromal cells (BMSCs) expanded to 5 × 106 cells after three weeks’ tissue culture. Calcium sulphate (CaSO4) in pellet form was combined with these cells at operation. The nonunion was clinically and radiologically healed two months after implantation.

This is the description of on healing of a long-standing tibial nonunion by tissue engineering. The successful combination of BMSCs and CaSO4 has not to our knowledge been reported in a clinical setting.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 143 - 150
1 Feb 2009
Toms AD Mandalia V Haigh R Hopwood B

The management of patients with a painful total knee replacement requires careful assessment and a stepwise approach in order to diagnose the underlying pathology accurately. The management should include a multidisciplinary approach to the patient’s pain as well as addressing the underlying aetiology. Pain should be treated with appropriate analgesia, according to the analgesic ladder of the World Health Organisation. Special measures should be taken to identify and to treat any neuropathic pain. There are a number of intrinsic and extrinsic causes of a painful knee replacement which should be identified and treated early. Patients with unexplained pain and without any recognised pathology should be treated conservatively since they may improve over a period of time and rarely do so after a revision operation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1164 - 1171
1 Sep 2008
Ochs BG Schmid U Rieth J Ateschrang A Weise K Ochs U

Deficiencies of acetabular bone stock at revision hip replacement were reconstructed with two different types of allograft using impaction bone grafting and a Burch-Schneider reinforcement ring. We compared a standard frozen non-irradiated bone bank allograft (group A) with a freeze-dried irradiated bone allograft, vitalised with autologous marrow (group B). We studied 78 patients (79 hips), of whom 87% (69 hips) had type III acetabular defects according to the American Academy of Orthopaedic Surgeons classification at a mean of 31.4 months (14 to 51) after surgery. At the latest follow-up, the mean Harris hip score was 69.9 points (13.5 to 97.1) in group A and 71.0 points (11.5 to 96.5) in group B. Each hip showed evidence of trabeculation and incorporation of the allograft with no acetabular loosening.

These results suggest that the use of an acetabular reinforcement ring and a living composite of sterile allograft and autologous marrow appears to be a method of reconstructing acetabular deficiencies which gives comparable results to current forms of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 715 - 723
1 Jun 2008
McMinn DJW Daniel J Ziaee H Pradhan C

The dysplasia cup, which was devised as an adjunct to the Birmingham Hip Resurfacing system, has a hydroxyapatite-coated porous surface and two supplementary neutralisation screws to provide stable primary fixation, permit early weight-bearing, and allow incorporation of morcellised autograft without the need for structural bone grafting.

A total of 110 consecutive dysplasia resurfacing arthroplasties in 103 patients (55 men and 48 women) performed between 1997 and 2000 was reviewed with a minimum follow-up of six years. The mean age at operation was 47.2 years (21 to 62) and 104 hips (94%) were Crowe grade II or III.

During the mean follow-up of 7.8 years (6 to 9.6), three hips (2.7%) were converted to a total hip replacement at a mean of 3.9 years (2 months to 8.1 years), giving a cumulative survival of 95.2% at nine years (95% confidence interval 89 to 100). The revisions were due to a fracture of the femoral neck, a collapse of the femoral head and a deep infection. There was no aseptic loosening or osteolysis of the acetabular component associated with either of the revisions performed for failure of the femoral component. No patient is awaiting a revision.

The median Oxford hip score in 98 patients with surviving hips at the final review was 13 and the 10th and the 90th percentiles were 12 and 23, respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1032 - 1038
1 Aug 2006
Hopgood P Kumar R Wood PLR

Between 1999 and 2005, 23 failed total ankle replacements were converted to arthrodeses. Three surgical techniques were used: tibiotalar arthrodesis with screw fixation, tibiotalocalcaneal arthrodesis with screw fixation, and tibiotalocalcaneal arthrodesis with an intramedullary nail. As experience was gained, the benefits and problems became apparent. Successful bony union was seen in 17 of the 23 ankles. The complication rate was higher in ankles where the loosening had caused extensive destruction of the body of the talus, usually in rheumatoid arthritis. In this situation we recommend tibiotalocalcaneal arthrodesis with an intramedullary nail. This technique can also be used when there is severe arthritic change in the subtalar joint. Arthrodesis of the tibiotalar joint alone using compression screws was generally possible in osteoarthritis because the destruction of the body of the talus was less extensive. Tibiotalocalcaneal arthrodesis fusion with compression screws has not been successful in our experience.