header advert
Results 61 - 80 of 1861
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1232 - 1239
1 Sep 2011
Stufkens SA van Bergen CJ Blankevoort L van Dijk CN Hintermann B Knupp M

It has been suggested that a supramalleolar osteotomy can return the load distribution in the ankle joint to normal. However, due to the lack of biomechanical data, this supposition remains empirical. The purpose of this biomechanical study was to determine the effect of simulated supramalleolar varus and valgus alignment on the tibiotalar joint pressure, in order to investigate its relationship to the development of osteoarthritis. We also wished to establish the rationale behind corrective osteotomy of the distal tibia. We studied 17 cadaveric lower legs and quantified the changes in pressure and force transfer across the tibiotalar joint for various degrees of varus and valgus deformity in the supramalleolar area. We assumed that a supramalleolar osteotomy which created a varus deformity of the ankle would result in medial overload of the tibiotalar joint. Similarly, we thought that creating a supramalleolar valgus deformity would cause a shift in contact towards the lateral side of the tibiotalar joint. The opposite was observed. The restricting role of the fibula was revealed by carrying out an osteotomy directly above the syndesmosis. In end-stage ankle osteoarthritis with either a valgus or varus deformity, the role of the fibula should be appreciated and its effect addressed where appropriate


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 388 - 389
1 Mar 2007
Kanakaraddi SV Nagaraj G Ravinath TM

Adamantinoma is a rare tumour of long bones that occurs most commonly in the tibia. Its pathogenesis is unknown. It is locally aggressive and recurrences are common after resection. Metastases have been reported in 10% to 20% of cases, most commonly in the lungs and rarely in the lymph nodes. We report a patient who developed a skeletal metastasis four years after resection of the primary tumour. There was no evidence of recurrence at the primary site or of secondary deposits in the lungs


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 426 - 432
1 Mar 2005
Mueller CA Eingartner C Schreitmueller E Rupp S Goldhahn J Schuler F Weise K Pfister U Suedkamp NP

The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 972 - 974
1 Nov 1997
Milner SA

Accurate measurement of the alignment of the tibia is important both clinically and in research. The conventional method of measuring the angle of malunion after a fracture of the shaft of the tibia is potentially inaccurate because the mechanical axis of the normal bone may not pass down the centre of the medullary canal. An alternative method is described in which a radiograph of the opposite tibia is used as a template. A sample of 56 sets of standard radiographs of healed fractures of the shaft of the tibia was evaluated. The 95% limits of agreement between this and the conventional method were wide, being −6.2° to +5.5° for coronal angulation and −6.7° to +8.1° for sagittal angulation. These results suggest that the conventional method is inaccurate. The new method has good inter- and intraobserver reliability


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 624 - 633
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML

Aim. The aim of this study was to compare the cost-effectiveness of intramedullary nail fixation and ‘locking’ plate fixation in the treatment of extra-articular fractures of the distal tibia. Patients and Methods. An economic evaluation was conducted from the perspective of the United Kingdom National Health Service (NHS) and personal social services (PSS), based on evidence from the Fixation of Distal Tibia Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients were available for analysis. Costs were collected prospectively over the 12-month follow-up period using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality adjusted life year (QALY) gained, and net monetary benefit. Sensitivity analyses were conducted to test the robustness of cost-effectiveness estimates. Results. Mean NHS and PSS costs were significantly lower for patients treated with an intramedullary nail than for those treated with a locking plate (-£970, 95% confidence interval (CI) -1685 to -256; p = 0.05). There was a small increase in QALYs gained in the nail fixation group (0.01, 95% CI -0.03 to 0.06; p = 0.52). The probability of cost-effectiveness for nail fixation exceeded 90% at cost-effectiveness thresholds as low as £15 000 per additional QALY. The cost-effectiveness results remained robust to several sensitivity analyses. Conclusion. This trial-based economic evaluation suggests that nail fixation is a cost-effective alternative to locking plate fixation. Cite this article: Bone Joint J 2018;100-B:624–33


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 2 | Pages 314 - 319
1 May 1971
Wellwood JM Bulmer JH Graff DJC

The case histories of two brothers with congenital defects of the tibia and neurofibromatosis are presented. This report of congenital pseudarthrosis of the tibia in siblings is believed to be the first in the English literature


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 990 - 991
1 Jul 2011
Mirzatolooei F

We report a variant of tibial hemimelia in a six-year-old boy that did not comply with recognised classification systems. The femur and knee were normal, but the fibula was displaced proximally and there was severe diastasis of the proximal and distal tibiofibular joints to the extent that a grossly deformed foot articulated with the fibula and there was separate soft-tissue cover for the distal tibia and fibula. Although it would have been preferable to create a one-bone leg, amputate the foot and use the fibula as the stump for a below-knee prosthesis, local circumstances resulted in the choice of a disarticulation through the knee. This was undertaken without complications, and six months post-operatively the child was walking comfortably with a prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 326 - 329
1 Mar 1987
Giladi M Milgrom C Simkin A Stein M Kashtan H Margulies J Rand N Chisin R Steinberg R Aharonson Z et A

A prospective study of 295 infantry recruits has shown that the mediolateral width of the tibia measured radiographically at each of three different levels in the bone had a statistically significant correlation with the total incidence of stress fractures as well as with those in the tibia alone or the femur alone. A narrow tibial width was shown to be a risk factor, but cortical thickness was not found to be significant


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 263 - 268
1 Mar 2002
Shinohara Y Kamegaya M Kuniyoshi K Moriya H

We have observed the natural history without treatment of 46 limbs in 29 patients with infantile tibia vara and a metaphyseal-diaphyseal angle (MDA) of more than 11°. The femorotibial angle (FTA) and MDA were measured, and Langenskiöld’s classification of radiological changes in the proximal medial metaphysis of the tibia was used. In 22 limbs which were not in Langenskiöld stages II to III the condition resolved spontaneously without treatment. Of the remaining 24 which were in stages II to III, in 18 it resolved spontaneously by the age of six years, but six showed little or no improvement at the latest follow-up. It was impossible to differentiate by measuring the FTA or MDA whether spontaneous resolution could be expected before the age of four years. There was no difference in the rate of resolution of the deformity between those patients who had been treated by a brace and those who had received no treatment. We advise no initial treatment but review at six-monthly intervals until the age of four years, even in patients with Langenskiöld stage-II to stage-III deformity. When a deformity persisted or progressed we carried out a corrective osteotomy after the age of four years


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1653 - 1659
1 Dec 2011
Bordei P

Platelet-derived growth factor (PDGF) is known to stimulate osteoblast or osteoprogenitor cell activity. We investigated the effect of locally applied PDGF from poly-. d. ,l-lactide (PDLLA)-coated implants on fracture healing in a rat model. A closed fracture of the right tibia of four-month-old Sprague-Dawley rats (n = 40) was stabilised with implants coated with a biodegradable PDLLA versus implants coated with PDLLA and PDGF. Radiographs were taken throughout the study, and a marker of DNA activity, bromodeoxyuridine (BrdU), was injected before the rats were killed at three, seven and ten days. The radiographs showed consolidation of the callus in the PDGF-treated group compared with the control group at all three time points. In the PDGF-treated group, immunohistochemical staining of BrdU showed that the distribution of proliferating cells in all cellular events was higher after ten days compared with that at three and seven days. These results indicate that local application of PDGF from biodegradable PDLLA-coated implants significantly accelerates fracture healing in experimental animals. Further development may help fracture healing in the clinical situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1627 - 1630
1 Dec 2008
Shiha AE Khalifa ARH Assaghir YM Kenawey MO

We present two children with massive defects of the tibia and an associated active infection who were treated by medial transport of the fibula using the Ilizarov device. The first child had chronic discharging osteomyelitis which affected the whole tibial shaft. The second had sustained bilateral grade-IIIB open tibial fractures in a motor-car accident. The first child was followed up for three years and the second for two years. Both achieved solid union between the proximal and distal stumps of the tibia and the fibula, with hypertrophy of the fibula. The first child had a normal range of movement at the knee, ankle and foot but there was shortening of 1.5 cm. The second had persistent anterior angulation at the proximal tibiofibular junction and the ankle was stiff in equinus


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1220 - 1225
1 Sep 2015
Chen LB Wang H Tie K Mohammed A Qi YJ

A total of 22 patients with a tibial avulsion fracture involving the insertion of the posterior cruciate ligament (PCL) with grade II or III posterior laxity were reduced and fixed arthroscopically using routine anterior and double posteromedial portals. A double-strand Ethibond suture was inserted into the joint and wrapped around the PCL from anterior to posterior to secure the ligament above the avulsed bony fragment. Two tibial bone tunnels were created using the PCL reconstruction guide, aiming at the medial and lateral borders of the tibial bed. The ends of the suture were pulled out through the bone tunnels and tied over the tibial cortex between the openings of the tunnels to reduce and secure the bony fragment. Satisfactory reduction of the fracture was checked arthroscopically and radiographically. The patients were followed-up for a mean of 24.5 months (19 to 28). Bone union occurred six weeks post-operatively. At final follow-up, all patients had a negative posterior drawer test and a full range of movement. KT-1000 arthrometer examination showed that the mean post-operative side-to-side difference improved from 10.9 mm (standard deviation (. sd. ) 0.7) pre-operatively to 1.5 mm (. sd. 0.6) (p = 0.001). The mean Tegner and the International Knee Documentation Committee scores improved significantly (p = 0.001). The mean Lysholm score at final follow-up was 92.0 (85 to 96). We conclude that this technique is convenient, reliable and minimally invasive and successfully restores the stability and function of the knee. Cite this article: Bone Joint J 2015;97-B:1220–5


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 1 | Pages 138 - 144
1 Feb 1966
Donner R Dikland R

1. A case of adamantinoma of the tibia was followed radiographically for seventeen years before a biopsy was performed. During this time there was an increase in size of the tumour and a gradual transformation of radio-opaque into polycystic areas. 2. Biopsy revealed a peculiar osteoid-like differentiation of the epithelial tissue


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 832 - 833
1 Aug 2001
Gödde S Rupp S Dienst M Seil R Kohn D

The Fulkerson osteotomy has proved to be a reliable treatment for subluxation of the patella due to malalignment. Aggressive rehabilitation in the early postoperative period is unwise since the proximal tibia is weakened by the oblique osteotomy. Early weight-bearing and unrestricted activity have caused fractures in a few patients. Even late in the postoperative period the osteotomy may adversely influence the biomechanical properties of the proximal tibia. We describe two athletes who sustained a fracture of the proximal tibia, during recreational activities, six months after a Fulkerson osteotomy. Both had been bearing full weight for about ten weeks without complaint. Bony healing of the osteotomy had been demonstrated on plain radiographs at ten and at 12 weeks. After a Fulkerson osteotomy, jogging and activities which impose considerable impact force should be discouraged for at least nine to 12 months


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 4 | Pages 735 - 738
1 Nov 1974
Braidwood AS McDougall A

Two cases of adamantinoma of the tibia are reported. The first patient has survived twenty years after above-knee amputation and shows no sign of recurrence. The second patient shows no evidence of recurrence two and a half years after amputation through the knee. The clinical picture of the tumour is described and the theories of histogenesis are outlined


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1065 - 1069
1 Nov 1990
de Bari A Krajbich J Langer F Hamilton E Hubbard S

Above-knee amputation has been the traditional treatment for osteosarcoma of the proximal tibia. Recent advances in chemotherapy have encouraged the development of limb-salvage techniques. Van Nes rotationplasty for malignant lesions of the distal femur has increased in popularity as a reconstructive technique, but no similar procedure has been described for lesions of the proximal tibia. We have developed a modified rotationplasty for this lesion and have performed it in four children. The surgical technique, postoperative management and results of the procedure are described. Two patients had delayed wound healing. No other complications have developed and our patients were disease-free at follow-up, while the appearance of the leg was well accepted by the patients and their parents. This procedure is a useful addition to the armamentarium of the tumour surgeon for the treatment of malignant lesions of the proximal tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 488 - 493
1 Apr 2008
Cho T Choi IH Lee SM Chung CY Yoo WJ Lee DY Lee JW

We investigated patterns of refracture and their risk factors in patients with congenital pseudarthrosis of the tibia after Ilizarov osteosynthesis. We studied 43 cases in 23 patients. Temporal and spatial patterns of refracture and refracture-free survival were analysed in each case. The refracture-free rate of cumulative survival was 47% at five years and did not change thereafter. Refracture occurred at the previous pseudarthrosis in 16 of 19 cases of refracture. The risk of refracture was significantly higher when osteosynthesis was performed below the age of four years, when the tibial cross-sectional area was narrow, and when associated with persistent fibular pseudarthrosis. Refracture occurs frequently after successful osteosynthesis in these patients. Delaying osteosynthesis, maximising the tibial cross-sectional area and stabilising the fibula may reduce the risk of refracture


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 71 - 76
1 Jan 1999
Gaston P Will E Elton RA McQueen MM Court-Brown CM

We have carried out a prospective study to determine whether the basic descriptive criteria and classifications of diaphyseal fractures of the tibia determine prognosis, as is widely believed. A number of systems which are readily available were used, with outcome being determined by standard measurements including fracture union, the need for secondary surgery and the incidence of infection. Many validated functional outcomes were also used. The Tscherne classification of closed fractures proved to be slightly more predictive of outcome than the others, but our findings indicate that such systems have little predictive value


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 2 | Pages 324 - 342
1 May 1955
Owen M Jowsey J Vaughan J

1. The detailed anatomy and calcification of the upper half of the tibia in rabbits varying in age from six weeks to twelve months has been studied. 2. The structure of the bone varies at different levels, but a section taken from the same level in the tibia from animals of the same age presents a reasonably constant picture. 3. It has been shown that this variation in structure at different levels is directly related to a difference between the axis of growth and the bone axis. This difference is a result of the unique shape of the tibia. 4. Autoradiographic studies confirm the localised concentration of radioactive strontium in areas of active bone formation where uptake is rapid. 5. The long retention of radioactive strontium in the skeleton (that is, the slow turnover) is a result of the slowness of resorption of bone (endosteal, periosteal or Haversian) in the cortex. Not only is the process slow but it is extremely localised. 6. The significance of these anatomical and physiological characteristics in relation to radiation injury is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 211 - 215
1 Mar 1991
Simonis R Shirali H Mayou B

We describe 11 patients with congenital pseudarthrosis of the tibia treated by a free vascularised fibular graft (FVFG) and followed up from 10 to 64 months (mean 38). Bony union was achieved in nine of the 11 cases: two failures required amputation. The mean time for union in the successful cases was five months. Nine of the 11 patients had had an average of four surgical procedures before the FVFG, so the graft was a salvage procedure for which the only alternative was amputation. FVFG is recommended as a primary procedure for the treatment of congenital pseudarthrosis of the tibia if there is a large tibial defect (over 3 cm) or shortening of more than 5 cm. The primary use of this operation is not advised for cases in which standard orthopaedic procedures are expected to succeed. For a small defect with a favourable prognosis (Boyd and Sage 1958), we recommend conventional bone grafting, intramedullary nailing and electrical stimulation