Advertisement for orthosearch.org.uk
Results 61 - 80 of 264
Results per page:
Bone & Joint Open
Vol. 2, Issue 5 | Pages 305 - 313
3 May 2021
Razii N Clutton JM Kakar R Morgan-Jones R

Aims. Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Two-stage revision has traditionally been considered the gold standard of treatment for established infection, but increasing evidence is emerging in support of one-stage exchange for selected patients. The objective of this study was to determine the outcomes of single-stage revision TKA for PJI, with mid-term follow-up. Methods. A total of 84 patients, with a mean age of 68 years (36 to 92), underwent single-stage revision TKA for confirmed PJI at a single institution between 2006 and 2016. In all, 37 patients (44%) were treated for an infected primary TKA, while the majority presented with infected revisions: 31 had undergone one previous revision (36.9%) and 16 had multiple prior revisions (19.1%). Contraindications to single-stage exchange included systemic sepsis, extensive bone or soft-tissue loss, extensor mechanism failure, or if primary wound closure was unlikely to be achievable. Patients were not excluded for culture-negative PJI or the presence of a sinus. Results. Overall, 76 patients (90.5%) were infection-free at a mean follow-up of seven years, with eight reinfections (9.5%). Culture-negative PJI was not associated with a higher reinfection rate (p = 0.343). However, there was a significantly higher rate of recurrence in patients with polymicrobial infections (p = 0.003). The mean Oxford Knee Score (OKS) improved from 18.7 (SD 8.7) preoperatively to 33.8 (SD 9.7) at six months postoperatively (p < 0.001). The Kaplan-Meier implant survival rate for all causes of reoperation, including reinfection and aseptic failure, was 95.2% at one year (95% confidence interval (CI) 87.7 to 98.2), 83.5% at five years (95% CI 73.2 to 90.3), and 78.9% at 12 years (95% CI 66.8 to 87.2). Conclusion. One-stage exchange, using a strict debridement protocol and multidisciplinary input, is an effective treatment option for the infected TKA. This is the largest single-surgeon series of consecutive cases reported to date, with broad inclusion criteria. Cite this article: Bone Jt Open 2021;2(5):305–313


Bone & Joint Open
Vol. 4, Issue 5 | Pages 393 - 398
25 May 2023
Roof MA Lygrisse K Shichman I Marwin SE Meftah M Schwarzkopf R

Aims. Revision total knee arthroplasty (rTKA) is a technically challenging and costly procedure. It is well-documented that primary TKA (pTKA) have better survivorship than rTKA; however, we were unable to identify any studies explicitly investigating previous rTKA as a risk factor for failure following rTKA. The purpose of this study is to compare the outcomes following rTKA between patients undergoing index rTKA and those who had been previously revised. Methods. This retrospective, observational study reviewed patients who underwent unilateral, aseptic rTKA at an academic orthopaedic speciality hospital between June 2011 and April 2020 with > one-year of follow-up. Patients were dichotomized based on whether this was their first revision procedure or not. Patient demographics, surgical factors, postoperative outcomes, and re-revision rates were compared between the groups. Results. A total of 663 cases were identified (486 index rTKAs and 177 multiply revised TKAs). There were no differences in demographics, rTKA type, or indication for revision. Multiply revised patients had significantly longer rTKA operative times (p < 0.001), and were more likely to be discharged to an acute rehabilitation centre (6.2% vs 4.5%) or skilled nursing facility (29.9% vs 17.5%; p = 0.003). Patients who had been multiply revised were also significantly more likely to have subsequent reoperation (18.1% vs 9.5%; p = 0.004) and re-revision (27.1% vs 18.1%; p = 0.013). The number of previous revisions did not correlate with the number of subsequent reoperations (r = 0.038; p = 0.670) or re-revisions (r = −0.102; p = 0.251). Conclusion. Multiply revised TKA had worse outcomes, with higher rates of facility discharge, longer operative times, and greater reoperation and re-revision rates compared to index rTKA. Cite this article: Bone Jt Open 2023;4(5):393–398


Bone & Joint 360
Vol. 12, Issue 6 | Pages 20 - 23
1 Dec 2023

The December 2023 Knee Roundup. 360. looks at: Obesity is associated with greater improvement in patient-reported outcomes following primary total knee arthroplasty; Does mild flexion of the femoral prosthesis in total knee arthroplasty result in better early postoperative outcomes?; Robotic or manual total knee arthroplasty: a randomized controlled trial; Patient-relevant outcomes following first revision total knee arthroplasty, by diagnosis: an analysis of implant survivorship, mortality, serious medical complications, and patient-reported outcome measures using the National Joint Registry data set; Sagittal alignment in total knee arthroplasty: are there any discrepancies between robotic-assisted and manual axis orientation?; Tourniquet use does not impact recovery trajectory in total knee arthroplasty; Impact of proximal tibial varus anatomy on survivorship after medial unicondylar knee arthroplasty; Bone cement directly to the implant in primary total knee arthroplasty?; Maintaining joint line obliquity optimizes outcomes in patients with constitutionally varus knees


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims. The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution. Methods. We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time. Results. The estimated survivorship free of all-cause revision was 98% (95% confidence interval (CI) 97% to 98%), 95% (95% CI 95% to 96%), and 86% (95% CI 83% to 88%) at two, five, and ten years, respectively. In 209/369 revisions there was a consistent constellation of findings with varying severity that included polyethylene wear and associated synovitis, osteolysis, and component loosening. This failure mode, which we refer to as aseptic mechanical failure, was the most common revision indication. The mean time from primary TKA to revision for aseptic mechanical failure was five years (5 months to 11 years). Conclusion. In this series of nearly 8,000 primary TKAs performed with a specific implant, we identified a lower-than-expected mid-term survivorship and a high number of revisions with a unique presentation. This study, along with the recent recall of the implant, confirms the need for frequent monitoring of patients with Optetrak TKAs given the incidence of polyethylene failure, osteolysis, and component loosening. Cite this article: Bone Joint J 2023;105-B(3):277–283


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims. The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery. Methods. A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series. Results. No patients in our series had evidence of radiolucent lines on their latest radiological assessment. Only eight patients out of 454 required revision arthroplasty, and none of these revisions were indicated for aseptic loosening of the tibial baseplate. When compared to data from the NJR annual report, Kaplan-Meier estimates from our series (2.94 (95% confidence interval (CI) 1.24 to 5.87)) show a significant reduction in cumulative estimates of revision compared to all cemented (4.82 (95% CI 4.69 to 4.96)) or cementless TKA (5.65 (95% CI 5.23 to 6.10)). Our data (2.94 (95% CI 1.24 to 5.87)) also show lower cumulative revision rates compared to the most popular implant (PFC Sigma Cemented Knee implant fixation, 4.03 (95% CI 3.75 to 4.33)). The prosthesis time revision rate (PTIR) estimates for our series (2.07 (95% CI 0.95 to 3.83)) were lower than those of cemented cases (4.53 (95% CI 4.49 to 4.57)) from NJR. Conclusion. The NexGen trabecular (tantalum) cementless implant has lower revision rates in our series compared to all cemented implants and other types of cementless implants, and its use in younger patients should be encouraged. Cite this article: Bone Jt Open 2024;5(4):277–285


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 641 - 648
1 Jun 2023
Bloch BV Matar HE Berber R Gray WK Briggs TWR James PJ Manktelow ARJ

Aims. Revision total knee arthroplasty (rTKA) and revision total hip arthroplasty (rTHA) are complex procedures with higher rates of re-revision, complications, and mortality compared to primary TKA and THA. We report the effects of the establishment of a revision arthroplasty network (the East Midlands Specialist Orthopaedic Network; EMSON) on outcomes of rTKA and rTHA. Methods. The revision arthroplasty network was established in January 2015 and covered five hospitals in the Nottinghamshire and Lincolnshire areas of the East Midlands of England. This comprises a collaborative weekly multidisciplinary meeting where upcoming rTKA and rTHA procedures are discussed, and a plan agreed. Using the Hospital Episode Statistics database, revision procedures carried out between April 2011 and March 2018 (allowing two-year follow-up) from the five network hospitals were compared to all other hospitals in England. Age, sex, and mean Hospital Frailty Risk scores were used as covariates. The primary outcome was re-revision surgery within one year of the index revision. Secondary outcomes were re-revision surgery within two years, any complication within one and two years, and median length of hospital stay. Results. A total of 57,621 rTHA and 33,828 rTKA procedures were performed across England, of which 1,485 (2.6%) and 1,028 (3.0%), respectively, were conducted within the network. Re-revision rates within one year for rTHA were 7.3% and 6.0%, and for rTKA were 11.6% and 7.4% pre- and postintervention, respectively, within the network. This compares to a pre-to-post change from 7.4% to 6.8% for rTHA and from 11.7% to 9.7% for rTKA for the rest of England. In comparative interrupted time-series analysis for rTKA there was a significant immediate improvement in one-year re-revision rates for the revision network compared to the rest of England (p = 0.024), but no significant change for rTHA (p = 0.504). For the secondary outcomes studied, there was a significant improvement in trend for one- and two-year complication rates for rTHA for the revision network compared to the rest of England. Conclusion. Re-revision rates for rTKA and complication rates for rTHA improved significantly at one and two years with the introduction of a revision arthroplasty network, when compared to the rest of England. Most of the outcomes studied improved to a greater extent in the network hospitals compared to the rest of England when comparing the pre- and postintervention periods. Cite this article: Bone Joint J 2023;105-B(6):641–648


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 675 - 681
1 Jun 2019
Gabor JA Padilla JA Feng JE Anoushiravani AA Slover J Schwarzkopf R

Aims. Revision total knee arthroplasty (rTKA) accounts for approximately 5% to 10% of all TKAs. Although the complexity of these procedures is well recognized, few investigators have evaluated the cost and value-added with the implementation of a dedicated revision arthroplasty service. The aim of the present study is to compare and contrast surgeon productivity in several differing models of activity. Materials and Methods. All patients that underwent primary or revision TKA from January 2016 to June 2018 were included as the primary source of data. All rTKA patients were categorized by the number of components revised (e.g. liner exchange, two or more components). Three models were used to assess the potential surgical productivity of a dedicated rTKA service : 1) work relative value unit (RVU) versus mean surgical time; 2) primary TKA with a single operating theatre (OT) versus rTKA with a single OT; and 3) primary TKA with two OTs versus rTKA with a single OT. Results. In total, 4570 procedures were performed: 4128 primary TKAs, 51 TKA liner exchanges, and 391 full rTKAs. Surgical time was significantly different between the primary TKA, liner exchange, and rTKA cohorts (100.6, 97.1, and 141.7 minutes, respectively; p < 0.001). Primary TKA yielded a mean of 7.1% more RVU/min per procedure than rTKA. Our one-OT model demonstrated that primary TKA (n = 4) had a 1.9% RVU/day advantage over rTKA (n = 3). If two OTs are used for primary TKA (n = 6), the outcome strongly favours primary TKA by an added 34.6% RVUs/day. Conclusion. Our results suggest that a dedicated rTKA service would lead to lower surgeon remuneration based on the current RVU paradigm. Revision arthroplasty specialists may need additional or alternative incentives to promote the development of a dedicated revision service. Through such an approach, healthcare organizations could enhance the quality of care provided, but surgeon productivity measures would need to be adjusted to reflect the burden of these cases. Cite this article: Bone Joint J 2019;101-B:675–681


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 667 - 674
1 Jun 2019
Schwarzkopf R Novikov D Anoushiravani AA Feng JE Vigdorchik J Schurko B Dwyer MK Bedair HS

Aims. With an ageing population of patients who are infected with hepatitis C virus (HCV), the demand for total knee arthroplasty (TKA) in this high-risk group continues to grow. It has previously been shown that HCV infection predisposes to poor outcomes following TKA. However, there is little information about the outcome of TKA in patients with HCV who have been treated successfully. The purpose of this study was to compare the outcomes of TKA in untreated HCV patients and those with HCV who have been successfully treated and have a serologically confirmed remission. Patients and Methods. A retrospective review of all patients diagnosed with HCV who underwent primary TKA between November 2011 and April 2018 was conducted. HCV patients were divided into two groups: 1) those whose HCV was cured (HCV-C); and 2) those in whom it was untreated (HCV-UT). All variables including demographics, HCV infection characteristics, surgical details, and postoperative medical and surgical outcomes were evaluated. There were 64 patients (70 TKAs) in the HCV-C group and 63 patients (71 TKAs) in the HCV-UT cohort. The mean age at the time of surgery was 63.0 years (. sd. 7.5; 44 to 79) in the HCV-C group and 61.7 years (. sd. 6.9; 47 to 88) in the HCV-UT group. Results. HCV-UT patients had a significantly longer mean hospital stay (3.4 days vs 2.9 days; p = 0.04), were more likely to be transferred to the intensive care unit (14.1% vs 4.3%; p = 0.04), and were significantly more often discharged to a post-acute care facility (39.4% vs 14.3%; p < 0.01). HCV-UT patients had significantly more postoperative infections (15.5% vs 4.3%; p = 0.03), surgical complications (21.1% vs 7.1%; p = 0.02), and revision TKA (12.7% vs 1.4%; p < 0.01) than HCV-C patients. Conclusion. The preoperative treatment of HCV can reduce the risk of complications, including prosthetic joint infection and revision TKA. We recommend that HCV treatment regimens should be integrated into the preoperative optimization protocol for this high-risk group of patients. Cite this article: Bone Joint J 2019;101-B:667–674


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims. Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up. Methods. Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk. Results. Fewer TKA patients with ‘poor’ outcomes (≤ 25) subsequently underwent revision compared with UKA at six months (5.1% vs 19.6%; p < 0.001), five years (4.3% vs 12.5%; p < 0.001), and ten years (6.4% vs 15.0%; p = 0.024). Compared with TKA, the relative risk for UKA was 2.5-times higher for ‘unknown’ reasons, bearing dislocations, and disease progression. Conclusion. Compared with TKA, more UKA patients with poor outcomes underwent revision from early to long-term follow-up, and were more likely to undergo revision for ‘unknown’ reasons, which suggest a lower clinical threshold for UKA. For UKA, revision risk was higher for bearing dislocations and disease progression. There is supporting evidence that the higher revision UKA rates are associated with lower clinical thresholds for revision and additional modes of failure. Cite this article: Bone Joint J 2023;105-B(3):269–276


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1043 - 1053
1 Aug 2018
Scott CEH Turnbull GS Powell-Bowns MFR MacDonald DJ Breusch SJ

Aims. The aim of this study was to identify predictors of return to work (RTW) after revision lower limb arthroplasty in patients of working age in the United Kingdom. Patients and Methods. We assessed 55 patients aged ≤ 65 years after revision total hip arthroplasty (THA). There were 43 women and 12 men with a mean age of 54 years (23 to 65). We also reviewed 30 patients after revision total knee arthroplasty (TKA). There were 14 women and 16 men with a mean age of 58 years (48 to 64). Preoperatively, age, gender, body mass index, social deprivation, mode of failure, length of primary implant survival, work status and nature, activity level (University of California, Los Angeles (UCLA) score), and Oxford Hip and Knee Scores were recorded. Postoperatively, RTW status, Oxford Hip and Knee Scores, EuroQol-5D (EQ-5D), UCLA score, and Work, Osteoarthritis and Joint-Replacement Questionnaire (WORQ) scores were obtained. Univariate and multivariate analysis was performed. Results. Overall, 95% (52/55) of patients were working before their revision THA. Afterwards, 33% (17/52) RTW by one year, 48% (25/52) had retired, and 19% (10/52) were receiving welfare benefit. RTW was associated with age, postoperative Oxford Hip Score, early THA failure (less than two years), mode of failure dislocation, and contralateral revision (p < 0.05). No patient returned to work after revision for dislocation. Only age remained a significant factor on multivariate analysis (p = 0.003), with 79% (11/14) of those less than 50 years of age returning to work, compared with 16% (6/38) of those aged fifty years or over. Before revision TKA, 93% (28/30) of patients were working. Postoperatively only 7% (2/28) returned to work by one year, 71% (20/28) had retired, and 21% (6/28) were receiving welfare benefits. UCLA scores improved after 43% of revision THAs and 44% of revision TKAs. Conclusion. After revision THA, age is the most significant predictor of RTW: only 16% of those over 50 years old return to work. Fewer patients return to work after early revision THA and none after revision for dislocation. After revision TKA, patients rarely return to work: none return to heavy or moderate manual work. Cite this article: Bone Joint J 2018;100-B:1043–53


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 122 - 128
1 Jul 2021
Tibbo ME Limberg AK Gausden EB Huang P Perry KI Yuan BJ Berry DJ Abdel MP

Aims. The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies, implant survivorship, and IPFF clinical outcomes. Methods. A total of 76 patients treated for an IPFF from February 1985 to April 2018 were reviewed. Prior to fracture, at the hip/knee sites respectively, 46 femora had primary/primary, 21 had revision/primary, three had primary/revision, and six had revision/revision components. Mean age and BMI were 74 years (33 to 99) and 30 kg/m. 2. (21 to 46), respectively. Mean follow-up after fracture treatment was seven years (2 to 24). Results. Overall, 59 fractures were classified as Vancouver C (Unified Classification System (UCS) D), 17 were Vancouver B (UCS B). In total, 57 patients (75%) were treated with open reduction and internal fixation (ORIF); three developed nonunion, three developed periprosthetic joint infection, and two developed aseptic loosening. In all, 18 patients (24%) underwent revision arthroplasty including 13 revision THAs, four distal femoral arthroplasties (DFAs), and one revision TKA: of these, one patient developed aseptic loosening and two developed nonunion. Survivorship free from any reoperation was 82% (95% confidence interval (CI) 66.9% to 90.6%) and 77% (95% CI 49.4% to 90.7%) in the ORIF and revision groups at two years, respectively. ORIF patients who went on to union tended to have stemmed knee components and greater mean interprosthetic distance (IPD = 189 mm (SD 73.6) vs 163 mm (SD 36.7); p = 0.546) than nonunited fractures. Patients who went on to nonunion in the revision arthroplasty group had higher medullary diameter: cortical width ratio (2.5 (SD 1.7) vs 1.3 (SD 0.3); p = 0.008) and lower IPD (36 mm (SD 30.6) vs 214 mm (SD 32.1); p < 0.001). At latest follow-up, 95% of patients (n = 72) were ambulatory. Conclusion. Interprosthetic femur fractures are technically and biologically challenging cases. Individualized approaches to internal fixation versus revision arthroplasty led to an 81% (95% CI 68.3% to 88.6%) survivorship free from reoperation at two years with 95% of patients ambulatory. Continued improvements in management are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):122–128


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 138 - 144
1 Jun 2020
Heckmann ND Nahhas CR Yang J Della Valle CJ Yi PH Culvern CN Gerlinger TL Nam D

Aims. In patients with a “dry” aspiration during the investigation of prosthetic joint infection (PJI), saline lavage is commonly used to obtain a sample for analysis. The aim of this study was to investigate prospectively the impact of saline lavage on synovial fluid analysis in revision arthroplasty. Methods. Patients undergoing revision hip (THA) or knee arthroplasty (TKA) for any septic or aseptic indication were enrolled. Intraoperatively, prior to arthrotomy, the maximum amount of fluid possible was aspirated to simulate a dry tap (pre-lavage) followed by the injection with 20 ml of normal saline and re-aspiration (post-lavage). Pre- and post-lavage synovial white blood cell (WBC) count, percent polymorphonuclear cells (%PMN), and cultures were compared. Results. A total of 78 patients had data available for analysis; 17 underwent revision THA and 61 underwent revision TKA. A total of 16 patients met modified Musculoskeletal Infection Society (MSIS) criteria for PJI. Pre- and post-lavage %PMNs were similar in septic patients (87% vs 85%) and aseptic patients (35% vs 39%). Pre- and post-lavage synovial fluid WBC count were far more disparate in septic (53,553 vs 8,275 WBCs) and aseptic (1,103 vs 268 WBCs) cohorts. At a cutoff of 80% PMN, the post-lavage aspirate had a sensitivity of 75% and specificity of 95%. At a cutoff of 3,000 WBCs, the post-lavage aspirate had a sensitivity of 63% and specificity of 98%. As the post-lavage synovial WBC count increased, the difference between pre- and post-lavage %PMN decreased (mean difference of 5% PMN in WBC < 3,000 vs mean difference 2% PMN in WBC > 3,000, p = 0.013). Of ten positive pre-lavage fluid cultures, only six remained positive post-lavage. Conclusion. While saline lavage aspiration significantly lowered the synovial WBC count, the %PMN remained similar, particularly at WBC counts of > 3,000. These findings suggest that in patients with a dry-tap, the %PMN of a saline lavage aspiration has reasonable sensitivity (75%) for the detection of PJI. Cite this article: Bone Joint J 2020;102-B(6 Supple A):138–144


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1477 - 1481
1 Nov 2017
Hernandez NM Taunton MJ Perry KI Mara KC Hanssen AD Abdel MP

Aims. Patients with flexion instability after total knee arthroplasty (TKA) often present with a recurrent effusion, which may be a haemarthrosis. While the radiographic factors contributing to flexion instability have been elucidated, the clinical diagnosis remains challenging. Our aim, in this study, was to determine the mean white cell count and differential profile in pre-operative aspirations of synovial fluid in a consecutive series of patients undergoing revision TKA for flexion instability. Patients and Methods. Between 2000 and 2010, 60 patients undergoing aseptic revision TKA for flexion instability were identified. The results of the pre-operative aspiration of synovial fluid were available for 53 patients (88%). These patients were 1:2 matched to 106 patients who underwent aseptic TKA for indications other than flexion instability. The mean age of the patients at revision TKA was 65 years (44 to 82) and 55% were women. The mean follow-up was 4.3 years (2 to 10.2). Results. In the flexion instability group, the median total cell count was 312 cells/µL (interquartile range (IQR) 104 to 624), with a mean distribution of 45% macrophages (2% to 90%), 30% lymphocytes (1% to 69%), 18% neutrophils (0% to 80%), 0.5% eosinophils (0% to 6%) and 7% other cells (0% to 42%; mainly synovial cells). There was no significant difference in the median total cell count (p = 0.14) or mean distribution of macrophages (p = 0.42), lymphocytes (p = 0.38), neutrophils (p = 0.19) and eosinophils (p = 0.89) between the flexion instability and control groups. There was a significant difference in the percentage of bloody serosanguineous aspirations which was 58% in the flexion instability group and 18% in the control group (odds ratio = 6.5; p = 0.0001). Conclusions. In the group of patients who underwent revision TKA for flexion instability, most had a mean cell count and differential similar to those who underwent revision for other aseptic indications. However, bloody serosanguineous aspirations were 6.5 times more common in those with flexion instability confirming that many of the recurrent effusions seen in this condition are haemarthroses. Cite this article: Bone Joint J 2017;99-B:1477–81


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 101 - 106
1 Jun 2020
Shah RF Bini SA Martinez AM Pedoia V Vail TP

Aims. The aim of this study was to evaluate the ability of a machine-learning algorithm to diagnose prosthetic loosening from preoperative radiographs and to investigate the inputs that might improve its performance. Methods. A group of 697 patients underwent a first-time revision of a total hip (THA) or total knee arthroplasty (TKA) at our institution between 2012 and 2018. Preoperative anteroposterior (AP) and lateral radiographs, and historical and comorbidity information were collected from their electronic records. Each patient was defined as having loose or fixed components based on the operation notes. We trained a series of convolutional neural network (CNN) models to predict a diagnosis of loosening at the time of surgery from the preoperative radiographs. We then added historical data about the patients to the best performing model to create a final model and tested it on an independent dataset. Results. The convolutional neural network we built performed well when detecting loosening from radiographs alone. The first model built de novo with only the radiological image as input had an accuracy of 70%. The final model, which was built by fine-tuning a publicly available model named DenseNet, combining the AP and lateral radiographs, and incorporating information from the patient’s history, had an accuracy, sensitivity, and specificity of 88.3%, 70.2%, and 95.6% on the independent test dataset. It performed better for cases of revision THA with an accuracy of 90.1%, than for cases of revision TKA with an accuracy of 85.8%. Conclusion. This study showed that machine learning can detect prosthetic loosening from radiographs. Its accuracy is enhanced when using highly trained public algorithms, and when adding clinical data to the algorithm. While this algorithm may not be sufficient in its present state of development as a standalone metric of loosening, it is currently a useful augment for clinical decision making. Cite this article: Bone Joint J 2020;102-B(6 Supple A):101–106


Bone & Joint Research
Vol. 7, Issue 10 | Pages 570 - 579
1 Oct 2018
Kallala R Harris WE Ibrahim M Dipane M McPherson E

Aims. Calcium sulphate has traditionally been used as a filler of dead space arising during surgery. Various complications have been described following the use of Stimulan bio-absorbable calcium sulphate beads. This study is a prospective observational study to assess the safety profile of these beads when used in revision arthroplasty, comparing the complication rates with those reported in the literature. Methods. A total of 755 patients who underwent 456 revision total knee arthroplasties (TKA) and 299 revision total hip arthroplasties (THA), with a mean follow-up of 35 months (0 to 78) were included in the study. Results. A total of 32 patients (4.2%) had wound drainage, and this was higher with higher bead volumes and in McPherson grade C patients. There was also a significantly higher bead volume in the 41 patients who developed hypercalcaemia, two of which were symptomatic (p < 0.0001). A total of 13 patients (1.7%) had heterotopic ossification (HO). There was no statistically significant relationship between the development of HO and bead volume (p > 0.05). Conclusion. The strength of this study lies in the large number of patients and the detailed data collection, making it the most comprehensive report available in the literature on the use of calcium sulphate-based bone substitutes. Cite this article: R. Kallala, W. Edwin Harris, M. Ibrahim, M. Dipane, E. McPherson. Use of Stimulan absorbable calcium sulphate beads in revision lower limb arthroplasty: Safety profile and complication rates. Bone Joint Res 2018;7:570–579. DOI: 10.1302/2046-3758.710.BJR-2017-0319.R1


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1084 - 1092
1 Oct 2024
Hammat AS Nelson R Davis JS Manning L Campbell D Solomon LB Gnanamanickam ES Callary SA

Aims

Our aim was to estimate the total costs of all hospitalizations for treating periprosthetic joint infection (PJI) by main management strategy within 24 months post-diagnosis using activity-based costing. Additionally, we investigated the influence of individual PJI treatment pathways on hospital costs within the first 24 months.

Methods

Using admission and procedure data from a prospective observational cohort in Australia and New Zealand, Australian Refined Diagnosis Related Groups were assigned to each admitted patient episode of care for activity-based costing estimates of 273 hip PJI patients and 377 knee PJI patients. Costs were aggregated at 24 months post-diagnosis, and are presented in Australian dollars.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 649 - 656
1 Jun 2023
Dagneaux L Amundson AW Larson DR Pagnano MW Berry DJ Abdel MP

Aims

Nonagenarians (aged 90 to 99 years) have experienced the fastest percent decile population growth in the USA recently, with a consequent increase in the prevalence of nonagenarians living with joint arthroplasties. As such, the number of revision total hip arthroplasties (THAs) and total knee arthroplasties (TKAs) in nonagenarians is expected to increase. We aimed to determine the mortality rate, implant survivorship, and complications of nonagenarians undergoing aseptic revision THAs and revision TKAs.

Methods

Our institutional total joint registry was used to identify 96 nonagenarians who underwent 97 aseptic revisions (78 hips and 19 knees) between 1997 and 2018. The most common indications were aseptic loosening and periprosthetic fracture for both revision THAs and revision TKAs. Mean age at revision was 92 years (90 to 98), mean BMI was 27 kg/m2 (16 to 47), and 67% (n = 65) were female. Mean time between primary and revision was 18 years (SD 9). Kaplan-Meier survival was used for patient mortality, and compared to age- and sex-matched control populations. Reoperation risk was assessed using cumulative incidence with death as a competing risk. Mean follow-up was five years.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 47 - 55
1 Jan 2023
Clement ND Avery P Mason J Baker PN Deehan DJ

Aims

The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision.

Methods

Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021).


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1330 - 1335
1 Oct 2018
Ponzio DY Weitzler L deMeireles A Esposito CI Wright TM Padgett DE

Aims. The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts. Materials and Methods. A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces. Results. A-XLPE inserts had higher rates of burnishing and lower rates of pitting and scratching compared with XLPE. There were no differences in the density of crosslinking at loaded and unloaded regions. A-XLPE showed higher oxidation indices in the unloaded surface region compared with XLPE. There were no differences in the levels of oxidation in the loaded regions. Conclusion. Retrieval analysis of A-XLPE did not reflect a clinically relevant difference in surface damage, density of crosslinking, or oxidation compared with XLPE tibial inserts at short-term evaluation. Cite this article: Bone Joint J 2018;100-B:1330–5


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 65 - 69
1 Jan 2017
Thienpont E

Objectives. Unicompartmental knee arthroplasty (UKA) is a potential treatment for isolated bone on bone osteoarthritis when limited to a single compartment. The risk for revision of UKA is three times higher than for total knee arthroplasty (TKA). The aim of this review was to discuss the different revision options after UKA failure. Materials and Methods. A search was performed for English language articles published between 2006 and 2016. After reviewing titles and abstracts, 105 papers were selected for further analysis. Of these, 39 papers were deemed to contain clinically relevant data to be included in this review. Results. The most common reasons for failure are liner dislocation, aseptic loosening, disease progression of another compartment and unexplained pain. . UKA can be revised to or with another UKA if the failure mode allows reconstruction of the joint with UKA components. In case of disease progression another UKA can be added, either at the patellofemoral joint or at the remaining tibiofemoral joint. Often the accompanying damage to the knee joint doesn’t allow these two former techniques resulting in a primary TKA. In a third of cases, revision TKA components are necessary. This is usually on the tibial side where augments and stems might be required. Conclusions. In case of failure of UKA, several less invasive revision techniques remain available to obtain primary results. Revision in a late stage of failure or because of surgical mistakes might ask for the use of revision components limiting the clinical outcome for the patients. Cite this article: Bone Joint J 2017;99-B(1 Supple A):65–9