Advertisement for orthosearch.org.uk
Results 61 - 80 of 3796
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 64 - 66
1 Jan 1987
Waterhouse N Beaumont A Murray K Staniforth P Stone M

We report a prospective study of the factors associated with acute urinary retention after total hip replacement in 103 consecutive male patients. Eleven patients (10.7%) developed retention after operation. Of the factors investigated before operation three had predictive value: inability to pass urine into a bottle whilst lying in bed, urinary peak-flow rates indicative of obstruction, and a history of previous bladder outflow problems. This study suggests that patients showing one or more of these factors should be assessed and if necessary treated by a urologist before arthroplasty, so as to avoid the need for catheterisation, and the consequent risk of deep infection


Bone & Joint Open
Vol. 1, Issue 6 | Pages 214 - 221
8 Jun 2020
Achten J Knight R Dutton SJ Costa ML Mason J Dritsaki M Appelbe D Messahel S Roland D Widnall J Perry DC

Aims

Torus fractures are the most common childhood fracture, accounting for 500,000 UK emergency attendances per year. UK treatment varies widely due to lack of scientific evidence. This is the protocol for a randomized controlled equivalence trial of ‘the offer of a soft bandage and immediate discharge’ versus ‘rigid immobilization and follow-up as per the protocol of the treating centre’ in the treatment of torus fractures .

Methods

Children aged four to 15-years-old inclusive who have sustained a torus/buckle fracture of the distal radius with/without an injury to the ulna are eligible to take part. Baseline pain as measured by the Wong Baker FACES pain scale, function using the Patient-Reported Outcomes Measurement Information System (PROMIS) upper limb, and quality of life (QoL) assessed with the EuroQol EQ-5D-Y will be collected. Each patient will be randomly allocated (1:1, stratified by centre and age group (four to seven years and ≥ eight years) to either a regimen of the offer of a soft bandage and immediate discharge or rigid immobilization and follow-up as per the protocol of the treating centre.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 566 - 569
1 Aug 1986
Roper B Tuke M O'Riordan S Bulstrode C

Sixty unconstrained elbow replacements of a new design have been followed prospectively for three to nine years. Review showed that 50% had excellent relief of pain and return of function, 27% had had major complications requiring removal or revision of the prosthesis and 23% had minor complications which marred the result. Further research in this field seems worthwhile


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 772 - 774
1 Sep 1990
Stanley D Stockley I Getty C

In a prospective study of 100 knee arthroplasties in patients with rheumatoid arthritis, simultaneous bilateral surgery was compared with staged bilateral replacements. All patients had improved function following their operations but those who had staged surgery only achieved maximum benefit after the second knee had been replaced. The complication rate was no greater for simultaneous surgery and we therefore advocate the method for those patients who require bilateral replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 625 - 628
1 Aug 1986
Newman R Muirhead A

An unusually wide pneumatic tourniquet has recently become available; we provide a simple formula for its use with a low but effective inflation pressure. A prospective, randomised and controlled trial in 600 lower limb and 150 upper limb operations is reported. The wide tourniquet (12.5 cm) was as effective at low pressure as was a conventional tourniquet (9 cm) inflated to significantly higher pressures. Fewer patients suffered from painful paraesthesiae after operation using the broad, low-pressure tourniquet


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims

In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia.

Patients and Methods

Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 366 - 369
1 May 1990
Vainionpaa S Laasonen E Silvennoinen T Vasenius J Rokkanen P

We report a prospective study of 55 patients with acute primary patellar dislocation, all treated by operation and followed up for at least two years. Diagnosis was based on the history of a lateral displacement, with medial tenderness and a positive apprehension test; redislocations were excluded. Before operation, the difference in lateral shift on skyline views of the injured and control patellae was highly significant. At operation, rupture of the medial retinaculum of the patella was seen in all but one case. There were medial marginal fractures of the patella in 23 cases. Subjective results of the operation were excellent or good in 44 of the 55 at two years with a redislocation rate of only 9%. Most patients were able to return to the same level of sporting activity as before the injury


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 635 - 638
1 Aug 1987
Villar R Marsh D Rushton N Greatorex R

A prospective study was made over a three-year period of 900 consecutive unilateral Colles' fractures. The radiographic features at the time of fracture, after reduction and one week later were measured and correlated with grip strength and range of movement at three years. The most significant radiographic feature to influence the outcome was the presence of shortening of the radius one week after reduction of the fracture. Persistent dorsal tilt, radiocarpal joint involvement and ulnar styloid fracture were each associated with reduced range of movement, but had no effect on grip strength. Extension of the fracture into the distal radio-ulnar joint was associated with reduced grip strength but had no effect on range of movement. Radial tilt of the radial fragment did not correlate with any aspect of the result after three years


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 246 - 254
1 Mar 1986
Behrens F Searls K

External fixation of fractures of the leg may give uneven results and a high rate of complications. We postulate that three basic principles can govern the optimal use of these devices. The external fixation frame should avoid damage to vital anatomical structures, it should allow access to the injured area and it should meet the mechanical demands of the patient and the injury. From 1978 to 1981 these principles were evaluated prospectively in 75 consecutive cases of complex tibial injury treated with an external frame. Most were open fractures. The study confirmed that the principles were safe and effective; they have general application and do not depend on the use of a particular frame or device. By following them we have eliminated the majority of complications seen after traditional methods of external fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 80 - 83
1 Jan 1987
Jorgensen U Sonne-Holm S Lauridsen F Rosenklint A

We report the results of a prospective longitudinal study of 147 athletes who had had a meniscectomy for an isolated meniscus injury. The patients were reviewed in detail after median periods of 4.5 years and 14.5 years and the results analysed. The frequency of complaints related to the operation increased from 53% at 4.5 years to 67% at 14.5 years, while demonstrable knee instability increased from 10% to 36%. The incidence of radiographic changes of degeneration rose from 40% to 89% and at late review 8% of patients had definite osteoarthritis by the criteria of Ahlback (1968). In consequence 46% had given up or reduced their sporting activity, and 6.5% had changed their occupation. Radiographic deterioration started after the 4.5-year review in 49% of the patients and was more frequent after lateral than medial meniscectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 971 - 975
1 Nov 1998
McCaskie AW Deehan DJ Green TP Lock KR Thompson JR Harper WM Gregg PJ

Early implants for total knee replacement were fixed to bone with cement. No firm scientific reason has been given for the introduction of cementless knee replacement and the long-term survivorship of such implants has not shown any advantage over cemented forms. In a randomised, prospective study we have compared cemented and uncemented total knee replacement and report the results of 139 prostheses at five years. Outcome was assessed both clinically by independent examination using the Nottingham knee score and radiologically using the Knee Society scoring system. Independent statistical analysis of the data showed no significant difference between cemented and cementless fixation for pain, mobility or movement. There was no difference in the radiological alignment at five years, but there was a notable disparity in the radiolucent line score. With cemented fixation there was a significantly greater number of radiolucent lines on anteroposterior radiographs of the tibia and lateral radiographs of the femur. At five years, our clinical results would not support the use of the more expensive cementless fixation whereas the radiological results are of unknown significance. Longer follow-up will determine any changes in the results and conclusions


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 502 - 505
1 Nov 1980
Rooker G Wilkinson J

A prospective study of allergic contact dermatitis after metal-on-plastic total hip replacement was undertaken in 69 patients, of whom 54 were available for review after operation. Before operation six patients were metal sensitive, but only one remained so afterwards; this patient had given a clear history of metal sensitivity and a titanium prosthesis had therefore been used. In all six patients the result of the operation was good and no case of loosening occurred. Sixty-three patients had negative patch tests before operation; in none of these was metal sensitivity detected after operation. Cutaneous sensitivity to various metals is well documented after the insertion of metal-on-metal prostheses and in failed prostheses. We have not found any such increased sensitivity after metal-on-plastic hip replacement. There is little evidence of a direct causal relationship between metal sensitivity and subsequent loosening. The cutaneous sensitivity may be the consequence of loosening rather than its cause. Our results suggest that, providing metal-on-plastic prostheses are used, routine patch testing before hip replacement is no longer required


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 153 - 156
1 Nov 2012
Su EP Perna M Boettner F Mayman DJ Gerlinger T Barsoum W Randolph J Lee G

Pain, swelling and inflammation are expected during the recovery from total knee arthroplasty (TKA) surgery. The severity of these factors and how a patient copes with them may determine the ultimate outcome of a TKA. Cryotherapy and compression are frequently used modalities to mitigate these commonly experienced sequelae. However, their effect on range of motion, functional testing, and narcotic consumption has not been well-studied. A prospective, multi-center, randomised trial was conducted to evaluate the effect of a cryopneumatic device on post-operative TKA recovery. Patients were randomised to treatment with a cryopneumatic device or ice with static compression. A total of 280 patients were enrolled at 11 international sites. Both treatments were initiated within three hours post-operation and used at least four times per day for two weeks. The cryopneumatic device was titrated for cooling and pressure by the patient to their comfort level. Patients were evaluated by physical therapists blinded to the treatment arm. Range of motion (ROM), knee girth, six minute walk test (6MWT) and timed up and go test (TUG) were measured pre-operatively, two- and six-weeks post-operatively. A visual analog pain score and narcotic consumption was also measured post-operatively. At two weeks post-operatively, both the treatment and control groups had diminished ROM and function compared to pre-operatively. Both groups had increased knee girth compared to pre- operatively. There was no significant difference in ROM, 6MWT, TUG, or knee girth between the 2 groups. We did find a significantly lower amount of narcotic consumption (509 mg morphine equivalents) in the treatment group compared with the control group (680 mg morphine equivalents) at up to two weeks postop, when the cryopneumatic device was being used (p < 0.05). Between two and six weeks, there was no difference in the total amount of narcotics consumed between the two groups. At six weeks, there was a trend toward a greater distance walked in the 6MWT in the treatment group (29.4 meters versus 7.9 meters, p = 0.13). There was a significant difference in the satisfaction scores of patients with their cooling regimen, with greater satisfaction in the treatment group (p < 0.0001). There was no difference in ROM, TUG, VAS, or knee girth at six weeks. There was no difference in adverse events or compliance between the two groups. A cryopneumatic device used after TKA appeared to decrease the need for narcotic medication from hospital discharge to 2 weeks post-operatively. There was also a trend toward a greater distance walked in the 6MWT. Patient satisfaction with the cryopneumatic cooling regimen was significantly higher than with the control treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 825 - 829
1 Sep 1993
Klosok J Pring D Jessop J Maffulli N

We compared the chevron and the Wilson metatarsal osteotomy for hallux valgus in a prospective randomised trial on 87 feet in 51 patients, reviewed at averages of 5.5 and 38 months after operation. The patients in the chevron group returned to work earlier and mobilised faster, but, at the later review, those in the Wilson group had better functional results and were more satisfied with the appearance of the foot. Correction of the hallux valgus angle was better maintained in patients in the Wilson group and they had a better range of motion at the metatarsophalangeal joint; fewer complained of metatarsalgia


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 848 - 850
1 Nov 1989
Bannister G Wallace W Stableforth P Hutson M

In a prospective study, 60 patients with acute acromioclavicular dislocation were randomly allocated to treatment with a broad arm sling or to reduction and fixation with a coracoclavicular screw. Of these 54 were followed for four years. Conservatively-treated patients regained movement significantly more quickly and fully, returned to work and sport earlier and had fewer unsatisfactory results than those having early operation. For severe dislocations, with acromioclavicular displacement of 2 cm or more, early surgery produced better results. Conservative management is best for most acute dislocations, but younger patients with severe displacement may benefit from early reduction and stabilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 740 - 743
1 Nov 1988
Hadlow V

A prospective neonatal screening programme for congenital dislocation of the hip is reported. This covered over 20,000 live births including all the babies born in one area, with a virtually complete follow-up. All babies were examined within the first seven days of life and all hips which were dislocated or unstable after four days (1.6%) were splinted. Only two screened cases were "missed" and subsequently detected at 15 and 18 months. No later cases were discovered, and patients between 10 and 20 years of age had apparently remained asymptomatic. The detailed results show that neonatal screening is effective in detecting and preventing a crippling disorder in otherwise normal people. The examination, though brief, is difficult to perform well; it is considered that failure of the method lies with the examiner and not with the tests


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 894 - 897
1 Nov 1993
Jonsson B Stromqvist B

In a prospective, consecutive study 93 patients who had had previous lumbar spinal surgery underwent repeat decompression for persistent or recurrent back and leg pain. The previous operations had been discectomies in 65 patients and decompression for spinal stenosis in 28; two of the latter group had also had posterolateral fusion. At the repeat operation, disc herniation was found in 19 patients, lateral spinal stenosis in 19, central spinal stenosis in 20 and periradicular fibrosis in 35. Ninety-one patients were followed up for two years after surgery; the effect of the operation was recorded using a four-scale grading system. The results were significantly related to the diagnosis. Nerve-root compression due to recurrent disc herniation or to bony compression responded well to repeat decompression. In patients with a single nerve-root compression the results were similar to those obtained in primary operations. Sciatica due to nerve-root scarring was seldom improved by the repeat operation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 49 - 53
1 Jan 2006
Tsumara N Yoshiya S Chin T Shiba R Kohso K Doita M

We undertook a prospective, randomised study in order to evaluate the efficacy of clamping the drains after intra-articular injection of saline with 1:500 000 adrenaline compared with post-operative blood salvage in reducing blood loss in 212 total knee arthroplasties. The mean post-operative drained blood volume after drain clamping was 352.1 ml compared to 662.3 ml after blood salvage (p < 0.0001). Allogenic blood transfusion was needed in one patient in the drain group and for three in the blood salvage group. Drain clamping with intra-articular injection of saline with adrenaline is more effective than post-operative autologous blood transfusion in reducing blood loss during total knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 945 - 949
1 Nov 1993
Maffulli N Binfield P King J Good C

We made a prospective arthroscopic study of 106 skeletally mature male sportsmen with an average age of 28.35 years (16.8 to 44) who presented with an acute haemarthrosis of the knee due to sporting activities. We excluded those with patellar dislocations, radiographic bone injuries, extra-articular ligamentous lesions or a previous injury to the same joint. The anterior cruciate ligament (ACL) was intact in 35 patients, partially disrupted in 28 and completely ruptured in 43. In the patients with an ACL lesion, associated injuries included meniscal tears (17 patients), cartilaginous loose bodies (6), and minimal osteochondral fractures of the patella (2), the tibial plateau (3) or the femoral condyle (9). We found no age-related trend in the pattern of ACL injuries. Isolated injuries included one small osteochondral fracture of the patella, and one partial and one total disruption of the posterior cruciate ligament. Three patients had cartilaginous loose bodies, and no injury was detected in five. Acute traumatic haemarthrosis indicates a serious ligament injury until proved otherwise, and arthroscopy is needed to complement careful history and clinical examination. All cases with a tense effusion developing within 12 hours of injury should have an aspiration. If haemarthrosis is confirmed, urgent admission and arthroscopy are indicated