Advertisement for orthosearch.org.uk
Results 61 - 80 of 1194
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1049 - 1053
1 Aug 2011
Putzer D Mayr E Haid C Reinthaler A Nogler M

In revision total hip replacement, bone loss can be managed by impacting porous bone chips. In order to guarantee sufficient mechanical strength, the bone chips have to be compacted. The aim of this study was to determine in an in vitro simulation whether the use of a pneumatic hammer leads to higher primary stability than manual impaction. Bone mass characteristics were measured by force and distance variation of a penetrating punch, which was lowered into a plastic cup filled with bone chips. From these measurements bulk density, contact stiffness, impaction hardness and penetration resistance were calculated for different durations of impaction.

We found that the pneumatic method reached higher values of impaction hardness, contact stiffness and bulk density suggesting an increase in stability of the implant. No significant differences were found between the two different methods concerning the penetration resistance. The pneumatic method might reduce the risk of fracture in vivo, as force peaks are smaller and applied for a shorter period. Results from manual impaction showed higher variability and depend much on the experience of the surgeon. The pneumatic hammer is a suitable tool to standardise the impaction process.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 922 - 925
1 Nov 1994
Naito M Ogata K Shiota E Oyama M

We performed curettage and bone grafting of amyloid cysts of the femoral neck in five patients on long-term haemodialysis. All had had hip pain on weight-bearing. The duration of haemodialysis before the operation averaged 15 years and the average age of the patients was 53 years. All the large cystic lesions were located in the anterosuperior quadrant of the femoral neck. At operation, they were found to consist of fibrous tissue containing amyloid deposits. Postoperatively, all five patients had painless hips and the grafts had incorporated into the bone defects


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1052 - 1057
1 Nov 1999
Giesen EBW Lamerigts NMP Verdonschot N Buma P Schreurs BW Huiskes R

The use of impacted, morsellised bone grafts has become popular in revision total hip arthroplasty (THA). The initial stability of the reconstruction and the effectiveness of any subsequent process of revitalisation and incorporation will depend on the mechanical integrity of the graft. Our aim in this study was to document the time-dependent mechanical properties of the morsellised graft. This information is useful in clinical application of the graft, in studies of migration of the implant and in the design of the joint. We used 16 specimens of impacted, morsellised cancellous bone from the sternum of goats to assess the mechanical properties by confined compression creep tests. Consideration of the graft material as a porous, permeable solid, filled with fluid, allowed determination of the compressive modulus of the matrix, and its permeability to fluid flow. In all specimens the compression tests showed large, irreversible deformations, caused by flow-independent creep behaviour as a result of rolling and sliding of the bone chips. The mean permeability was 8.82 *10. −12. m. 4. /Ns (SD 43%), and the compressive modulus was 38.7 MPa (SD 34%). No correlation was found between the apparent density and the permeability or between the apparent density and the compressive modulus. The irreversible deformations in the graft could be captured by a creep law, for which the parameters were quantified. We conclude that in clinical use the graft is bound to be subject to permanent deformation after operation. The permeability of the material is relatively high compared with, for example, human cartilage. The confined compression modulus is relatively low compared with cancellous bone of the same apparent density. Designs of prostheses used in revision surgery must accommodate the viscoelastic and permanent deformations in the graft without causing loosening at the interface


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 229 - 233
1 Mar 1987
Hirst P Esser M Murphy J Hardinge K

Total hip replacement has been very successful in patients with painful, stiff hips associated with protrusio acetabuli, but the heat of polymerisation of methylmethacrylate cement may cause necrosis of the thin medial wall with consequent danger of migration of the cup. Since 1968 at Wrightington, thin slices of the head of the femur have been used as bone grafts to reinforce the acetabulum. We have reviewed 61 hips in 51 patients at an average of 4 years 3 months after operation. Grading for severity is discussed and the degree of physiological remodelling of the medial wall of the acetabulum after grafting assessed. There was an average of about 4 mm of remodelling, but this varied considerably; most took place within the first year. In no case was there relapse of the protrusio


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1633 - 1639
1 Dec 2018
Zhao Z Yan T Guo W Yang R Tang X Yang Y

Aims

We retrospectively report our experience of managing 30 patients with a primary malignant tumour of the distal tibia; 25 were treated by limb salvage surgery and five by amputation. We compared the clinical outcomes of following the use of different methods of reconstruction.

Patients and Methods

There were 19 male and 11 female patients. The mean age of the patients was 19 years (6 to 59) and the mean follow-up was 5.1 years (1.25 to 12.58). Massive allograft was used in 11 patients, and autograft was used in 14 patients. The time to union, the survival time of the reconstruction, complication rate, and functional outcomes following the different surgical techniques were compared. The overall patient survival was also recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 436 - 444
1 Apr 2000
van Loon CJM de Waal Malefijt MC Buma P Stolk PWT Verdonschot N Tromp AM Huiskes R Barneveld A

The properties of impacted morsellised bone graft (MBG) in revision total knee arthroplasty (TKA) were studied in 12 horses. The left hind metatarsophalangeal joint was replaced by a human TKA. The horses were then randomly divided into graft and control groups. In the graft group, a unicondylar, lateral uncontained defect was created in the third metatarsal bone and reconstructed using autologous MBG before cementing the TKA. In the control group, a cemented TKA was implanted without the bone resection and grafting procedure. After four to eight months, the animals were killed and a biomechanical loading test was performed with a cyclic load equivalent to the horse’s body-weight to study mechanical stability. After removal of the prosthesis, the distal third metatarsal bone was studied radiologically, histologically and by quantitative and micro CT. Biomechanical testing showed that the differences in deformation between the graft and the control condyles were not significant for either elastic or time-dependent deformations. The differences in bone mineral density (BMD) between the graft and the control condyles were not significant. The BMD of the MBG was significantly lower than that in the other regions in the same limb. Micro CT showed a significant difference in the degree of anisotropy between the graft and host bone, even although the structure of the area of the MBG had trabecular orientation in the direction of the axial load. Histological analysis revealed that all the grafts were revascularised and completely incorporated into a new trabecular structure with few or no remnants of graft. Our study provides a basis for the clinical application of this technique with MBG in revision TKA


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 622 - 626
1 Jul 1994
Cobb T Linscheid R

We treated three patients with malunion after comminuted intercondylar fractures of the humerus by intra-articular derotational opening-wedge osteotomy and the insertion of a tricortical iliac bone graft. Two patients required additional operations, including interposition arthroplasty and hardware removal. A mean arc of increased motion of 65 degrees was achieved in flexion and extension in two patients and a more functional arc in the third. Although this is viewed as a salvage procedure in patients who are thought to be too young for elbow arthroplasty, none of the three patients has significant pain and none has required total elbow arthroplasty after an average follow-up of 7.6 years


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 268 - 273
1 May 1983
Baksi D

Twenty-nine patients with avascular necrosis of the femoral head after injury have been treated by operation. Multiple drilling of the femoral head was performed, necrotic bone removed and a muscle-pedicle bone graft implanted into the head and neck of the femur. In 17 of the patients the necrosis was associated with an un-united femoral neck fracture, in 11 it occurred after the fracture had united, and one case followed reduction of a dislocated hip. The hips became painless soon after operation. The patients were young (average age 35 years), and full weight-bearing was not allowed for several months. The follow-up period ranged from 22 to 64 months. The results were excellent in 20 patients, good in five, fair in three and poor in one


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 804 - 808
1 Nov 1985
Bell S Dooley B O'Brien B Bright N

A cortical bone graft on a muscle pedicle was taken from the ulna and transferred to bridge a complete defect of the radius in 16 dogs. In 14 control dogs a free graft was used, that is, one without a muscle pedicle. Union in the group with pedicle grafts was far superior to that in the group with free grafts, mainly because in those with pedicle grafts there was good subperiosteal new bone formation from active viable periosteum. In six of the pedicle grafts the viability of some osteocytes was retained over a 12-week period and in five the graft was almost completely replaced by new bone


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 441 - 445
1 Aug 1981
Gray J Elves M

It has been shown in experimental animals that the living cells in a bone autograft can make an important contribution to osteogenesis. However, some common clinical techniques, such as the topical use of antibiotic powders on grafts or on the graft bed, are likely to damage or kill the cells. In this experimental study in rats, bone isografts dusted with chloramphenicol or methicillin powder or with Polybactrin spray before subcutaneous implantation produced little or no new bone over a period of two weeks whereas untreated, control grafts showed abundant osteogenesis, as did grafts pretreated with solutions of antibiotics. The effect of short-term storage of the grafts for 3 to 24 hours in air, saline or culture medium before implantation was also examined. Grafts stored in culture medium generally did as well as, or better than, fresh control grafts whereas immersion in saline inhibited osteogenesis. The importance of these results for clinical bone grafting is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1471 - 1474
1 Oct 2010
Chang Y Shih H Chen DW Lee MS Ueng SWN Hsieh P

We investigated the antibiotic concentration in fresh-frozen femoral head allografts harvested from two groups of living donors. Ten samples were collected from patients with osteoarthritis of the hip and ten from those with a fracture of the neck of the femur scheduled for primary arthroplasty. Cefazolin (1 g) was administered as a pre-operative prophylactic antibiotic. After storage at −80°C for two weeks the pattern of release of cefazolin from morsellised femoral heads was evaluated by an in vitro broth elution assay using high-performance liquid chromatography. The bioactivity of the bone was further determined with an agar disc diffusion and standardised tube dilution bioassay. The results indicated that the fresh-frozen femoral heads contained cefazolin. The morsellised bone released cefazolin for up to four days. The concentration of cefazolin was significantly higher in the heads from patients with osteoarthritis of the hip than in those with a fracture. Also, in bioassays the bone showed inhibitory effects against bacteria.

We concluded that allografts of morsellised bone from the femoral head harvested from patients undergoing arthroplasty of the hip contained cefazolin, which had been administered pre-operatively and they exhibited inhibitory effects against bacteria in vitro.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 798 - 801
1 Aug 2002
Murata Y Takahashi K Yamagata M Sameda H Moriya H

In patients who underwent autogenous iliac bone grafting we studied prospectively injury to the lateral femoral cutaneous nerve (LFCN) in relation to the size (length, depth, width) of the graft. We also examined the neurological deficit, by questioning them about numbness and/or pain in the lateral thigh. The risk of injury was significantly higher in those in whom the depth of the graft was more than 30 mm. With regard to the length of the graft the incidence of nerve injury was 20% when the graft was 45 mm long or more, 16% when it was between 30 mm and 45 mm long, and 8% when it was less than 30 mm long. We should inform patients of the possibility of such injury, and take size into consideration when harvesting grafts from the ilium


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 706 - 707
1 Sep 1991
Solomon L


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 667 - 674
1 May 2018
Lauthe O Soubeyrand M Babinet A Dumaine V Anract P Biau DJ

Aims

The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use.

Patients and Methods

We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74).


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 807 - 816
1 Jun 2014
Rajaee SS Kanim LEA Bae HW

Using the United States Nationwide Inpatient Sample, we identified national trends in revision spinal fusion along with a comprehensive comparison of comorbidities, inpatient complications and surgical factors of revision spinal fusion compared to primary spinal fusion.

In 2009, there were 410 158 primary spinal fusion discharges and 22 128 revision spinal fusion discharges. Between 2002 and 2009, primary fusion increased at a higher rate compared with revision fusion (56.4% vs 51.0%; p < 0.001). In 2009, the mean length of stay and hospital charges were higher for revision fusion discharges than for primary fusion discharges (4.2 days vs 3.8 days, p < 0.001; USD $91 909 vs. $87 161, p < 0.001). In 2009, recombinant human bone morphogenetic protein (BMP) was used more in revision fusion than in primary fusion (39.6% vs 27.6%, p < 0.001), whereas interbody devices were used less in revision fusion (41.8% vs 56.6%, p < 0.001).

In the multivariable logistic regression model for all spinal fusions, depression (odds ratio (OR) 1.53, p < 0.001), psychotic disorders (OR 1.49, p < 0.001), deficiency anaemias (OR 1.35, p < 0.001) and smoking (OR 1.10, p = 0.006) had a greater chance of occurrence in revision spinal fusion discharges than in primary fusion discharges, adjusting for other variables. In terms of complications, after adjusting for all significant comorbidities, this study found that dural tears (OR 1.41; p < 0.001) and surgical site infections (OR 3.40; p < 0.001) had a greater chance of occurrence in revision spinal fusion discharges than in primary fusion discharges (p < 0.001). A p-value < 0.01 was considered significant in all final analyses.

Cite this article: Bone Joint J 2014;96-B:807–16.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1242 - 1249
1 Sep 2015
Hintermann B Wagener J Knupp M Schweizer C J. Schaefer D

Large osteochondral lesions (OCLs) of the shoulder of the talus cannot always be treated by traditional osteochondral autograft techniques because of their size, articular geometry and loss of an articular buttress. We hypothesised that they could be treated by transplantation of a vascularised corticoperiosteal graft from the ipsilateral medial femoral condyle.

Between 2004 and 2011, we carried out a prospective study of a consecutive series of 14 patients (five women, nine men; mean age 34.8 years, 20 to 54) who were treated for an OCL with a vascularised bone graft. Clinical outcome was assessed using a visual analogue scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score. Radiological follow-up used plain radiographs and CT scans to assess graft incorporation and joint deterioration.

At a mean follow-up of 4.1 years (2 to 7), the mean VAS for pain had decreased from 5.8 (5 to 8) to 1.8 (0 to 4) (p = 0.001) and the mean AOFAS hindfoot score had increased from 65 (41 to 70) to 81 (54 to 92) (p = 0.003). Radiologically, the talar contour had been successfully reconstructed with stable incorporation of the vascularised corticoperiosteal graft in all patients. Joint degeneration was only seen in one ankle.

Treatment of a large OCL of the shoulder of the talus with a vascularised corticoperiosteal graft taken from the medial condyle of the femur was found to be a safe, reliable method of restoring the contour of the talus in the early to mid-term.

Cite this article: Bone Joint J 2015;97-B:1242–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 869 - 870
1 Sep 1991


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 615 - 618
1 May 2012
ten Have BLEF Brouwer MD RW van Biezen FC Verhaar JAN

The purpose of this prospective study was to evaluate the long-term clinical and radiological outcomes of revision of the femoral component of a total hip replacement using impaction bone grafting. Femoral revision with an impacted allograft was performed on 29 patients (31 hips). In all, 21 hips (68%) had grade III or IV femoral defects according to the Endo-Klinik classification. A total of 11 patients (12 hips) died before the ten-year follow-up period. Of the remaining patients, 18 patients (19 hips) were followed for 10 to 15 years; three further patients died during this time. None of the 31 stems underwent further revision of their stem. However, four stems showed extensive subsidence (> 15 mm). One of these patients had a femoral fracture that required fixation. Three other patients had a femoral fracture, two of which required fixation and the other was treated conservatively. Patients with a femoral fracture and/or severe subsidence had significantly more grade IV defects (six of seven hips; p = 0.004). One patient needed a closed reduction for dislocation.

Impaction allografting in revision hip surgery gives good long-term results for femora with grades I, II and III Endo-Klinik-classified defects. Extensive subsidence and femoral fractures were seen mainly in patients with grade IV damaged femora.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 586 - 591
1 May 2006
Wang J Fong C Su Y Yu H

Failure of total hip arthroplasty with acetabular deficiency occurred in 55 patients (60 hips) and was treated with acetabular revision using morsellised allograft and a cemented metal-backed component. A total of 50 patients (55 hips) were available for clinical and radiological evaluation at a mean follow-up of 5.8 years (3 to 9.5). No hip required further revision of the acetabular component because of aseptic loosening.

All the hips except one had complete incorporation of the allograft demonstrated on the radiographs. A complete radiolucent line of > 1 mm was noted in two hips post-operatively. A good to excellent result occurred in 50 hips (91%). With radiological evidence of aseptic loosening of the acetabular component as the end-point, the survivorship at a mean of 5.8 years after surgery was 96.4%.

The use of impacted allograft chips in combination with a cemented metal-backed acetabular component and screw fixation can achieve good medium-term results in patients with acetabular bone deficiency.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)).

At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed.

No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks.

This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation.

Cite this article: Bone Joint J 2013;95-B:1514–20.